Delta ERD139 User manual

USER MANUAL
MODELS: ERD139 • ERD140
p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
DELTA UNDERCOUNTER GLASS DOOR CHILLERS
DELTA UNDERCOUNTER CHILLERS

p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
2
Introduction.............................................................................................................................3
Safety Instructions...........................................................................................................3
Package Contents ...........................................................................................................4
Installation.................................................................................................................................4
Operation...................................................................................................................................5
Cleaning, Care & Maintenance.........................................................................6
Trouble Shooting...............................................................................................................6
TABLE OF CONTENTS

p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
3
• Position on a flat, stable surface.
• A service agent/qualified technician should carry out installation and any
repairs if required. Do not remove any components or service panels on this
product.
• Consult Local and National Standards to comply with the following:
• Health and Safety at Work Legislation
• BS EN Codes of Practice
• Fire Precautions
• IEE Wiring Regulations
• Building Regulations
• DO NOT immerse in water, or use steam/jet washers to clean the unit.
• DO NOT cover the appliance when it is operating.
• DO NOT store food in the appliance.
• DO NOT use electrical appliances inside the appliance.
• Always carry, store and handle the appliance in a vertical position.
• Never tilt the appliance more than 45° from the vertical.
• Not suitable for outdoor use.
• Keep all packaging away from children. Dispose of the packaging in accordance
with the regulations of local authorities.
• If the power cord is damaged, it must be replaced by a agent or a recommended
qualified technician in order to avoid a hazard.
• This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience or
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Not for Foodstus
Please take a few moments to carefully read through this manual. Correct maintenance
and operation of this machine will provide the best possible performance from your
product.
INTRODUCTION
SAFETY INSTRUCTIONS

p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
4
1. Remove the appliance from the packaging and the protective film from all surfaces.
2. Avoid positioning the appliance in direct sunlight or damp areas.
3. When positioning the appliance, maintain a distance of 20cm (7 inches) between
the appliance and walls or other objects for ventilation. Increase this distance if the
obstacle is a heat source.
4. Insert the slide-out shelf/shelves at the desired levels and place the smaller shelf/
shelves on the floor of the appliance.
5. If necessary, adjust the screw feet of the appliance to make it level.
All Models
The following is included:
• Back Bar Chiller
• Key
• Instruction manual
Prides itself on quality and service, ensuring that at the time of packaging the contents
are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your dealer
immediately.
PACKAGE CONTENT
INSTALLATION
Note: Before using the appliance for the first time, clean the shelves
and interior with soapy water.
!
Note: If the unit has not been stored or moved in an upright position, let
it stand upright for approximately 12 hours before operation. If in doubt
allow to stand.
!
1 DOOR MODELS
• 2 adjustable shelves
2 DOOR MODELS
• 4 adjustable shelves
3 DOOR MODELS
• 6 adjustable shelves

p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
5
OPERATION
Turn On
1. Close the door of the appliance.
2. Connect the appliance to a mains power supply.
3. Turn the light switches On [I] or O [O] as desired.
Set the Operating Temperature
1. Press the SET button. The display will flash.
2. Press the or AUX buttons to display the
required temperature.
3. Press the SET button to store the temperature.
Manual Defrost
Back Bar Chillers feature an automatic defrost. However, should the appliance require
an additional defrost period press and hold the button for 6 seconds.
Automatic defrost cycles are every 6 hours and last 20 minutes (factory defaults).
To stop the Defrost press and hold the button for 6 seconds.
Control Panel
The control panel is located below the doors on the front of the appliance.
Note: The Cooling Light is illuminated when the appliance is chilling
the interior cabinet.
!
Note: If a manual defrost is started this resets the automatic defrost
timer. During defrost periods the Defrost light is illuminated.
!
SET AUX

p: 0800 503 335 | w: www.southernhospitality.co.nz
e: weborders@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
6
• Switch o and disconnect from the power supply before cleaning.
• Clean the interior of the appliance as often as possible.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• Always wipe dry after cleaning.
• A POLAR agent or qualified technician must carry out repairs if required.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance.
If your appliance develops a fault, please check the following table before making a
call to the Helpline.
Fault Probable Cause Action
The appliance is not
working
The unit is not switched on Check the unit is plugged in correctly and
switched on
Plug and lead are damaged Call POLAR agent or qualified Technician
Fuse in the plug has blown Replace the fuse
Power supply Check power supply
Internal wiring fault Call agent or qualified Technician
The appliance turns on,
but the temperature is
too high/low
Condenser blocked with dust Clean Condenser
Doors/ drawers are not shut
properly
Check doors / drawers are shut and seals
are not damaged
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Move the appliance to a more suitable
location
Ambient temperature is too high Increase ventilation or move appliance to
a cooler position
Insucient airflow to the fans Remove any blockages to the fans
Appliance is overloaded Reduce the amount stored in the
appliance
Factory default parameters
adjusted Call agent or qualified Technician
The appliance is
unusually loud
The appliance is touching a
neighbouring object
Check installation position and change if
necessary
The appliance has not been
installed in a level or stable
position
Check installation position and change if
necessary
CLEANING, CARE & MAINTENANCE
TROUBLE SHOOTING
Note: Use a soft brush or vacuum cleaner to clean the fins of the
condenser, taking care not to damage the fins.
!
This manual suits for next models
1
Table of contents
Other Delta Chiller manuals
Popular Chiller manuals by other brands

S&A
S&A CWFL-6000 user manual

Pfannenberg
Pfannenberg EB 210 Series Operating and maintenance instructions

Carrier
Carrier AQUAFORCE 30XA080-500 Product data

Mueller
Mueller PMC 40/50 Instructions for installation and operation

koppel
koppel KFM - 36CHW Operation manual

Carrier
Carrier 30GTN Service and troubleshooting guide