1. Safety Instructions
• MustselectcorrectACinputvoltagerangethroughselectableswitchbeforeturningon(Referto
Fig.1,⑥).
• To ensure sufcient convection cooling, always maintain a safety distance of ≥ 20mm from all
ventilatedsurfaceswhilethedeviceisinoperation.
• Thedevice isnot recommendedto beplaced onlow thermalconductive surface,for example,
plastics.
• Notethattheenclosureofthedevicecanbecomeveryhotdependingontheambienttemperature
andloadofthepowersupply.Donottouchthedevicewhileitisinoperationorimmediatelyafter
poweristurnedOFF.Riskofburning!
• Donottouchtheterminalswhilepowerisbeingsupplied.Riskofelectricshock.
• Preventanyforeignmetal,particlesorconductorstoenterthedevicethroughtheopeningsduring
installation.Itcancause:Electricshock;SafetyHazard;Fire;Productfailure
• Batteryneedtobeprotectedfromshortcircuitwhileinstallation&servicing.Dangerofexplosion.
• SignalcableshouldnotinteractwithACInput.
• Warning:Whenconnectingthedevice,secureEarthconnectionbeforeconnectingLandN.When
disconnectingthedevice,removeLandNconnectionsbeforeremovingtheEarthconnection.
2. Device Descriptions
RefertoFig.1.:
䐟Input&Outputterminalblockconnector
䐠DCvoltageadjustmentpotentiometer(12V-14V)
䐡Green LED ON = DC OK (Normal operation through mains supply or through battery when
operatinginbufferingmode)
մRedLEDON=Batteryreversepolarity
յBatterychargingcurrentadjustmentpotentiometer(FactorySetting:1A)
Max charging current shall not exceed 1.5A (Refer to Fig. 1,
⑤
).
նACselectableswitch
䷻Signalconnector-JST:XHP-4(forPMU-13V155WCCAonly)
3. Installation of the Device
RefertoFig.2.:
䑵Mountingholesforthepowersupplyassemblyontothemountingsurface.Thepowersupplyshall
bemountedonminimum2mountingholesusingM3screwminimum5mmlength.
䑶Thissurfacebelongstocustomer’sendsystemorpanelwherethedeviceismounted.
䑷Connector
• Useexiblecable(strandedorsolid),AWGNo.16-14.
• ThetorqueattheConnectorshallnotexceed13Kgf.cm.Theinsulationstrippinglengthshouldnot
exceed0.275”or7mm(RefertoFig.3).
4. Battery Information
Battery Capacity 3.2AH-15AH
Battery Cut-off Voltage 10V±1V
Battery Low (Deep Discharge) Detection* 7V±1V
*Ifthebatteryisdeepdischarged,thepowersupplywillnotrecognizethebattery.
5. Installation of Mounting Accessories
RefertoFig.4.:
• OnlyuseM3screw≤2.5mmthroughthebasemountingholes.Thisistokeepasafetydistance
betweenthescrewandinternalcomponents.
• Recommendedmountingtighteningtorque:4~8Kgf.cm.
www.DeltaPSU.comREV.01
Fig. 1. Device Descriptions
Fig. 3. Wire Type Fig. 4. Mounting Screw
Lug Stripped wire
Mounting
accessories
Mounting
screw
Chassis of
the device
2.5mm
max.
7 mm
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
A
B
A
B
A
C
C
C
B
A
B
A
B
A
C
C
C
B
A
B
A
B
A
C
C
C
B
Fig. 2. Mounting Orientation
Base surface
Top surface
Ventilated surface
Side surface
12
3
5
4
6
PMU-13V155WCBA (no signal connector) PMU-13V155WCCA (with signal connector)
Base surface
Top surface
Ventilated surface
Side surface
12
5
6
7
3
4
Pin No.
1
2
3
4
DCOK
LowBattery
GND
ACOK
Description
7Signalconnector
JST:XHP-4
400mm.(Ref.)
Instruction Manual PMU-13V155WL□A
1. Safety Instructions
• MustselectcorrectACinputvoltage rangethroughselectable switchbeforeturning on(Referto
Fig.1,⑥).
• To ensure sufcient convection cooling, always maintain a safety distance of ≥ 20mm from all
ventilatedsurfaceswhilethedeviceisinoperation.
• Forsafetyreasons,pleaseensurethemounteddeviceiskeptat≥7mmsafetydistanceatthetop
andleftsidefromothercomponentsandequipments(RefertoFig.2).
• The device is not recommended to be placed on low thermal conductive surface, for example,
plastics.
• Notethattheenclosureofthedevicecanbecomeveryhotdependingontheambienttemperature
andloadofthepowersupply.Donottouchthedevicewhileitisinoperationorimmediatelyafter
poweristurnedOFF.Riskofburning!
• Donottouchtheterminalswhilepowerisbeingsupplied.Riskofelectricshock.
• Preventanyforeignmetal,particlesorconductorstoenterthedevicethroughtheopeningsduring
installation.Itcancause:Electricshock;SafetyHazard;Fire;Productfailure
• Batteryneedtobeprotectedfromshortcircuitwhileinstallation&servicing.Dangerofexplosion.
• SignalcableshouldnotinteractwithACInput.
• Warning:Whenconnectingthedevice,secureEarthconnectionbeforeconnectingLandN.When
disconnectingthedevice,removeLandNconnectionsbeforeremovingtheEarthconnection.
2. Device Descriptions
RefertoFig.1.:
䐟Input&Outputterminalblockconnector
䐠DCvoltageadjustmentpotentiometer(12V-14V)
䐡Green LED ON = DC OK (Normal operation through mains supply or through battery when
operatinginbufferingmode)
մRedLEDON=Batteryreversepolarity
յBatterychargingcurrentadjustmentpotentiometer(FactorySetting:1A)
Max charging current shall not exceed 1.5A (Refer to Fig. 1,
⑤
).
նACselectableswitch
䷻Signalconnector-JST:XHP-4(forPMU-13V155WLCAonly)
3. Installation of the Device
RefertoFig.3.:
䑵Mountingholesforthepowersupplyassemblyontothemountingsurface.Thepowersupplyshall
bemountedonminimum2mountingholesusingM3screwminimum5mmlength.
䑶Thissurfacebelongstocustomer’sendsystemorpanelwherethedeviceismounted.
䑷Connector
• Useexiblecable(strandedorsolid),AWGNo.16-14.
• ThetorqueattheConnectorshallnotexceed13Kgf.cm.Theinsulationstrippinglengthshouldnot
exceed0.275”or7mm(RefertoFig.4).
4. Battery Information
Battery Capacity 3.2AH-15AH
Battery Cut-off Voltage 10V±1V
Battery Low (Deep Discharge) Detection* 7V±1V
*Ifthebatteryisdeepdischarged,thepowersupplywillnotrecognizethebattery.
5. Installation of Mounting Accessories
RefertoFig.5.:
• OnlyuseM3screw≤2.5mmthroughthebasemountingholes.Thisistokeepasafetydistance
betweenthescrewandinternalcomponents.
• Recommendedmountingtighteningtorque:4~8Kgf.cm.
www.DeltaPSU.comREV.00
Fig. 1. Device Descriptions
Fig. 4. Wire Type Fig. 5. Mounting Screw
Lug Stripped wire
Mounting
accessories
Mounting
screw
Chassis of
the device
2.5mm
max.
7 mm
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
A
B
C
A
C
BA
B
C
A
B
C
A
C
B
A
B
C
A
B
C
A
C
B
A
B
C
Fig. 3. Mounting Orientation
Signalconnector-JST:XHP-4
(forPMU-13V155WLCAonly)
7
Base surface
Side surface
127
3
5
4
6
Fig. 2. Assembly Reference
≥ 7mm
CN1
PSU
CN1
≥ 7mm
PSU
TOP SIDE
LEFT SIDE
LEFT
TOP
Pin No.
1
2
3
4
DCOK
LowBattery
GND
ACOK
Description
400mm.(Ref.)

This manual suits for next models

2

Other Delta Portable Generator manuals

Delta 5COM-PAC User manual

Delta

Delta 5COM-PAC User manual

Delta Commercial Steam 5COM09-PAC User manual

Delta

Delta Commercial Steam 5COM09-PAC User manual

Delta 5GE-SMP05 Series User manual

Delta

Delta 5GE-SMP05 Series User manual

Delta SVG300A43A-11 Operator's manual

Delta

Delta SVG300A43A-11 Operator's manual

Delta PQC Series User manual

Delta

Delta PQC Series User manual

Popular Portable Generator manuals by other brands

Tecnogas ProCLEAN OZZY 3 Operation manual

Tecnogas

Tecnogas ProCLEAN OZZY 3 Operation manual

AIRMAC LC 1800 DC instruction manual

AIRMAC

AIRMAC LC 1800 DC instruction manual

PowerPro Technology 56101 owner's manual

PowerPro Technology

PowerPro Technology 56101 owner's manual

iPower GXS2300i owner's manual

iPower

iPower GXS2300i owner's manual

Kohler 14/20RESA Operation

Kohler

Kohler 14/20RESA Operation

Voltmaster VI770 user manual

Voltmaster

Voltmaster VI770 user manual

Toyama ATS owner's manual

Toyama

Toyama ATS owner's manual

Troy-Bilt 1924 owner's manual

Troy-Bilt

Troy-Bilt 1924 owner's manual

Briggs & Stratton 030430 Service and repair manual

Briggs & Stratton

Briggs & Stratton 030430 Service and repair manual

Baumer HUBNER BERLIN GTB 9 Mounting and operating instructions

Baumer

Baumer HUBNER BERLIN GTB 9 Mounting and operating instructions

Briggs & Stratton 040248A Operator's manual

Briggs & Stratton

Briggs & Stratton 040248A Operator's manual

Westerbeke 20.0KW sbeg Operator's manual

Westerbeke

Westerbeke 20.0KW sbeg Operator's manual

Mitsubishi Heavy Industries MGE1801 owner's manual

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries MGE1801 owner's manual

Genesis DEL ozone CD-2G Installation & operation manual

Genesis

Genesis DEL ozone CD-2G Installation & operation manual

Leelbox GR2300iS owner's manual

Leelbox

Leelbox GR2300iS owner's manual

DUROMAX DuroStar DS11000X user manual

DUROMAX

DUROMAX DuroStar DS11000X user manual

Parkside PISE 3400 A1 Operating and Safety Instructions, Translation of Original Operating Manual

Parkside

Parkside PISE 3400 A1 Operating and Safety Instructions, Translation of Original Operating Manual

Snapper 5600 Illustrated parts list

Snapper

Snapper 5600 Illustrated parts list

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.