manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Delta
  6. •
  7. Portable Generator
  8. •
  9. Delta PMU-13V155WCBA User manual

Delta PMU-13V155WCBA User manual

Instruction Manual PMU-13V155WC□A
1. Safety Instructions
• MustselectcorrectACinputvoltagerangethroughselectableswitchbeforeturningon(Referto
Fig.1,⑥).
• To ensure sufcient convection cooling, always maintain a safety distance of ≥ 20mm from all
ventilatedsurfaceswhilethedeviceisinoperation.
• Thedevice isnot recommendedto beplaced onlow thermalconductive surface,for example,
plastics.
• Notethattheenclosureofthedevicecanbecomeveryhotdependingontheambienttemperature
andloadofthepowersupply.Donottouchthedevicewhileitisinoperationorimmediatelyafter
poweristurnedOFF.Riskofburning!
• Donottouchtheterminalswhilepowerisbeingsupplied.Riskofelectricshock.
• Preventanyforeignmetal,particlesorconductorstoenterthedevicethroughtheopeningsduring
installation.Itcancause:Electricshock;SafetyHazard;Fire;Productfailure
• Batteryneedtobeprotectedfromshortcircuitwhileinstallation&servicing.Dangerofexplosion.
• SignalcableshouldnotinteractwithACInput.
• Warning:Whenconnectingthedevice,secureEarthconnectionbeforeconnectingLandN.When
disconnectingthedevice,removeLandNconnectionsbeforeremovingtheEarthconnection.
2. Device Descriptions
RefertoFig.1.:
䐟Input&Outputterminalblockconnector
䐠DCvoltageadjustmentpotentiometer(12V-14V)
䐡Green LED ON = DC OK (Normal operation through mains supply or through battery when
operatinginbufferingmode)
մRedLEDON=Batteryreversepolarity
յBatterychargingcurrentadjustmentpotentiometer(FactorySetting:1A)
Max charging current shall not exceed 1.5A (Refer to Fig. 1,
⑤
).
նACselectableswitch
䷻Signalconnector-JST:XHP-4(forPMU-13V155WCCAonly)
3. Installation of the Device
RefertoFig.2.:
䑵Mountingholesforthepowersupplyassemblyontothemountingsurface.Thepowersupplyshall
bemountedonminimum2mountingholesusingM3screwminimum5mmlength.
䑶Thissurfacebelongstocustomer’sendsystemorpanelwherethedeviceismounted.
䑷Connector
• Useexiblecable(strandedorsolid),AWGNo.16-14.
• ThetorqueattheConnectorshallnotexceed13Kgf.cm.Theinsulationstrippinglengthshouldnot
exceed0.275”or7mm(RefertoFig.3).
4. Battery Information
Battery Capacity 3.2AH-15AH
Battery Cut-off Voltage 10V±1V
Battery Low (Deep Discharge) Detection* 7V±1V
*Ifthebatteryisdeepdischarged,thepowersupplywillnotrecognizethebattery.
5. Installation of Mounting Accessories
RefertoFig.4.:
• OnlyuseM3screw≤2.5mmthroughthebasemountingholes.Thisistokeepasafetydistance
betweenthescrewandinternalcomponents.
• Recommendedmountingtighteningtorque:4~8Kgf.cm.
www.DeltaPSU.comREV.01
Fig. 1. Device Descriptions
Fig. 3. Wire Type Fig. 4. Mounting Screw
Lug Stripped wire
Mounting
accessories
Mounting
screw
Chassis of
the device
2.5mm
max.
7 mm
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
A
B
A
B
A
C
C
C
B
A
B
A
B
A
C
C
C
B
A
B
A
B
A
C
C
C
B
Fig. 2. Mounting Orientation
Base surface
Top surface
Ventilated surface
Side surface
12
3
5
4
6
PMU-13V155WCBA (no signal connector) PMU-13V155WCCA (with signal connector)
Base surface
Top surface
Ventilated surface
Side surface
12
5
6
7
3
4
Pin No.
1
2
3
4
DCOK
LowBattery
GND
ACOK
Description
7Signalconnector
JST:XHP-4
400mm.(Ref.)
Instruction Manual PMU-13V155WL□A
1. Safety Instructions
• MustselectcorrectACinputvoltage rangethroughselectable switchbeforeturning on(Referto
Fig.1,⑥).
• To ensure sufcient convection cooling, always maintain a safety distance of ≥ 20mm from all
ventilatedsurfaceswhilethedeviceisinoperation.
• Forsafetyreasons,pleaseensurethemounteddeviceiskeptat≥7mmsafetydistanceatthetop
andleftsidefromothercomponentsandequipments(RefertoFig.2).
• The device is not recommended to be placed on low thermal conductive surface, for example,
plastics.
• Notethattheenclosureofthedevicecanbecomeveryhotdependingontheambienttemperature
andloadofthepowersupply.Donottouchthedevicewhileitisinoperationorimmediatelyafter
poweristurnedOFF.Riskofburning!
• Donottouchtheterminalswhilepowerisbeingsupplied.Riskofelectricshock.
• Preventanyforeignmetal,particlesorconductorstoenterthedevicethroughtheopeningsduring
installation.Itcancause:Electricshock;SafetyHazard;Fire;Productfailure
• Batteryneedtobeprotectedfromshortcircuitwhileinstallation&servicing.Dangerofexplosion.
• SignalcableshouldnotinteractwithACInput.
• Warning:Whenconnectingthedevice,secureEarthconnectionbeforeconnectingLandN.When
disconnectingthedevice,removeLandNconnectionsbeforeremovingtheEarthconnection.
2. Device Descriptions
RefertoFig.1.:
䐟Input&Outputterminalblockconnector
䐠DCvoltageadjustmentpotentiometer(12V-14V)
䐡Green LED ON = DC OK (Normal operation through mains supply or through battery when
operatinginbufferingmode)
մRedLEDON=Batteryreversepolarity
յBatterychargingcurrentadjustmentpotentiometer(FactorySetting:1A)
Max charging current shall not exceed 1.5A (Refer to Fig. 1,
⑤
).
նACselectableswitch
䷻Signalconnector-JST:XHP-4(forPMU-13V155WLCAonly)
3. Installation of the Device
RefertoFig.3.:
䑵Mountingholesforthepowersupplyassemblyontothemountingsurface.Thepowersupplyshall
bemountedonminimum2mountingholesusingM3screwminimum5mmlength.
䑶Thissurfacebelongstocustomer’sendsystemorpanelwherethedeviceismounted.
䑷Connector
• Useexiblecable(strandedorsolid),AWGNo.16-14.
• ThetorqueattheConnectorshallnotexceed13Kgf.cm.Theinsulationstrippinglengthshouldnot
exceed0.275”or7mm(RefertoFig.4).
4. Battery Information
Battery Capacity 3.2AH-15AH
Battery Cut-off Voltage 10V±1V
Battery Low (Deep Discharge) Detection* 7V±1V
*Ifthebatteryisdeepdischarged,thepowersupplywillnotrecognizethebattery.
5. Installation of Mounting Accessories
RefertoFig.5.:
• OnlyuseM3screw≤2.5mmthroughthebasemountingholes.Thisistokeepasafetydistance
betweenthescrewandinternalcomponents.
• Recommendedmountingtighteningtorque:4~8Kgf.cm.
www.DeltaPSU.comREV.00
Fig. 1. Device Descriptions
Fig. 4. Wire Type Fig. 5. Mounting Screw
Lug Stripped wire
Mounting
accessories
Mounting
screw
Chassis of
the device
2.5mm
max.
7 mm
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
A
B
C
A
C
BA
B
C
A
B
C
A
C
B
A
B
C
A
B
C
A
C
B
A
B
C
Fig. 3. Mounting Orientation
Signalconnector-JST:XHP-4
(forPMU-13V155WLCAonly)
7
Base surface
Side surface
127
3
5
4
6
Fig. 2. Assembly Reference
≥ 7mm
CN1
PSU
CN1
≥ 7mm
PSU
TOP SIDE
LEFT SIDE
LEFT
TOP
Pin No.
1
2
3
4
DCOK
LowBattery
GND
ACOK
Description
400mm.(Ref.)

This manual suits for next models

2

Other Delta Portable Generator manuals

Delta 5GE-SMP05 Series User manual

Delta

Delta 5GE-SMP05 Series User manual

Delta SVG300A43A-11 Operator's manual

Delta

Delta SVG300A43A-11 Operator's manual

Delta 5COM-PAC User manual

Delta

Delta 5COM-PAC User manual

Delta PQC Series User manual

Delta

Delta PQC Series User manual

Delta Commercial Steam 5COM09-PAC User manual

Delta

Delta Commercial Steam 5COM09-PAC User manual

Popular Portable Generator manuals by other brands

Daewoo DDAE6000XE user manual

Daewoo

Daewoo DDAE6000XE user manual

EcoFlow River 600 user manual

EcoFlow

EcoFlow River 600 user manual

Parker CVX0260B Training & maintenance manual

Parker

Parker CVX0260B Training & maintenance manual

AEG Powertools AGN5000DEB Original instructions

AEG

AEG Powertools AGN5000DEB Original instructions

Bass BP-5018 user manual

Bass

Bass BP-5018 user manual

Sportsman GEN3000IOF Step-by-step guide

Sportsman

Sportsman GEN3000IOF Step-by-step guide

CENTENT CN0173 operating manual

CENTENT

CENTENT CN0173 operating manual

Middle Atlantic Products RLM Series instruction sheet

Middle Atlantic Products

Middle Atlantic Products RLM Series instruction sheet

Champion Global Power Equipment 201085 quick start guide

Champion Global Power Equipment

Champion Global Power Equipment 201085 quick start guide

Meech 993R operating manual

Meech

Meech 993R operating manual

Suin TFG6800 Series user guide

Suin

Suin TFG6800 Series user guide

Northern Lights M944WF3 Operator's manual

Northern Lights

Northern Lights M944WF3 Operator's manual

Mase FM 50H Use and maintenance manual

Mase

Mase FM 50H Use and maintenance manual

Giga-tronics 2400 series Programming manual

Giga-tronics

Giga-tronics 2400 series Programming manual

Golden engineering XRS4 Operator's manual

Golden engineering

Golden engineering XRS4 Operator's manual

ProVista Technology ECOBOXX160 Installation and operating instructions

ProVista Technology

ProVista Technology ECOBOXX160 Installation and operating instructions

Energizer eZV4800 user guide

Energizer

Energizer eZV4800 user guide

DUROMAX DuroStar DS1050 user manual

DUROMAX

DUROMAX DuroStar DS1050 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.