PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
1
PMT
Highlights & Features
– AC input range selectable by switch
– Full Aluminium casing for light weight and corrosion resistant
handling
– Built-in automatic fan speed control circuit
– Wide operating temperature range from -20°C to +70°C and
cold start at -40°C
– MTBF > 700,000 hrs. as per Telcordia SR-332
– Short Circuit / Overvoltage / Overload / Over Temperature
Protections
Safety Standards
CB Certified for worldwide use
Model Number: PMT-4V350W1A☐
Unit Weight: 0.81 kg
Dimensions (L x W x D): 215 x 115 x 50 mm
General Description
The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers
and solution providers - Delta. PMT-4V350W1A☐ offers a nominal output voltage of 4.2V with a wide operating temperature range
from -20°C to +70°C and can withstand shock and vibration (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In
addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other
brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the
components and product specifications. The series of products has an expected life time of 10 years and will have no output power de-
rating from 100Vac to 132Vac & 180Vac to 264Vac.
Model Information
PMT Panel Mount Power Supply
Model
Number
Input Voltage Range Output
V
oltage
Output Curr
ent
PMT-4V350W1A☐ 90-132Vac, 180-264Vac
(Selectable by Switch)
4.2Vdc 60.0A
Model Numbering
CC Code**
PM T –4V
350W
1
A
□
□
Panel Mount Product Type
T – Enclosed
Output Voltage
Output Power
(350W series
model)
Single Phase No PFC
Series
Connector Type
M – Terminal Block
N – Front Face*
Blank – Without
connector cover
A –
With connector
cover
*Options
**For Terminal Block
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
2
Specifications
Input Ratings / Characteristics
Nominal Input Voltage 100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range 90-132Vac, 180-264Vac (Selectable by Switch)
Nominal Input Frequency 50-60Hz
Input Frequency Range 47-63Hz
Input Current < 7.00A @ 115Vac, < 4.00A @ 230Vac
Efficiency at 100% Load > 75.0% @ 230Vac
Max Inrush Current (Cold Start) < 40A @ 115Vac, < 60A @ 230Vac
Leakage Current < 3.5mA @ 240Vac
Output Ratings / Characteristics
Nominal Output Voltage 4.2Vdc
Output Voltage Tolerance ± 3% (initial set point tolerance from factory)
Output Voltage Adjustment Range 3.78-4.70Vdc
Output Current 60.0A
Output Power 252W
Line Regulation ± 0.5% typ.
Load Regulation ± 2.5% typ.
PARD (20MHz) < 150mVpp
Rise Time < 50ms @ nominal input (100% load)
Start-up Time < 1000ms @ nominal input (100% load)
Hold-up Time > 16ms @ 115Vac, > 20ms @ 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 1000mVpp @ 10-50% load and 50-100% load
Start-up with Capacitive Loads 8,000µF Max
Mechanical
Case Chassis Aluminium
Case Cover Aluminium
Dimensions (L x W x D) 215 x 115 x 50 mm
Unit Weight
0.81 kg
Indicator Green LED (DC OK)
Cooling System Forced Cooling
Terminal PMT-4V350W1AM☐ M3.5 x 9 Pins (Rated 300V/15A)
PMT-4V350W1AN M3.5 x 9 Pins (Rated 300V/20A)
Wire
AWG 14-12
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
3
Environment
Surrounding Air Temperature Operating -20°C to +70°C
Storage -40°C to +85°C
Power De-rating > 50°C de-rate power by 4% / °C,
> 60°C de-rate power by 1% / °C
< 100Vac de-rate power by 3% / V,
< 200Vac de-rate power by 1.5% / V
Operating Humidity 5 to 95% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters
Shock Test (Non-Operating) IEC 60068-2-27, Half Sine: 50G for a duration of 11ms
,
3 times per direction,18 times in total
Vibration Operating IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S²
(2.5G peak); 90 min per axis for all X, Y, Z direction
Non-Operating IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms
peak; 20 min per axis for all X, Y, Z direction
Pollution Degree 2
Protections
Overvoltage < 4.83~7.00V, SELV Output, Latch Mode
Overload / Overcurrent > 105~135% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
Over Temperature Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Short Circuit Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Protection Against Shock Class I with PE* connection
*PE: Primary Earth
Reliability Data
MTBF > 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C
Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical Safety UL/cUL recognized to UL 60950-1 and CSA C22.2
No. 60950-1, CB scheme to IEC 60950-1
Material and Parts RoHS Directive 2011/65/EU Compliant
Galvanic Isolation Input to Output 3.0KVac
Input to Ground 1.5KVac
Output to Ground 0.5KVac
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
4
EMC
EMC / Emissions* CISPR 22, EN 55022, FCC Title 47: Class A
(With Delta EMI filter P/N: 10DKAW5)
Immunity to* EN 55024
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A
1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A
1)
2kV
Surge IEC 61000-4-5 Level 3 Criteria A
1)
Common Mode2): 2kV
Differential Mode3): 1kV
Conducted IEC 61000-4-6 Level 3 Criteria A
1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A
1)
10A/Meter
Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A
1)
Common Mode2): 2kV
Differential Mode3): 1kV
Harmonic Current Emission NA
Voltage Fluctuation and Flicker* IEC/EN 61000-3-3
*Fulfills tested conditions
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
5
Block Diagram
Device Description
1) Input & Output terminal block connector
2) DC voltage adjustment potentiometer
3) DC OK control LED (Green)
4) AC selectable switch
PMT-4V350W1AM☐: Terminal Block
PMT-4V350W1AN: Front Face
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
6
Dimensions
L x W x D: 215 x 115 x 50 mm (PMT-4V350W1AM☐: Terminal Block)
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
7
L x W x D: 215 x 115 x 50 mm (PMT-4V350W1AN: Front Face)
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
8
Engineering Data
De-rating
Output De-rating VS. Input Voltage
Note
1. Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1.
2. If the output capacity is not reduced when the
surrounding air temperature >70
°C, the
device will run into Over Temperature
Protection. When activated, the output
voltage will go into bouncing mode and will
recover
when the surrounding air
temperature is lowered or the load is reduced
as far as necessary to keep the device in
working condition.
3.
To ensure sufficient convection cooling,
always maintain a distance of ≥ 20mm from
fan ventilated surfaces while the device is in
operation.
4.
Depending on the surrounding air
temperature and output load delivered by the
power supply, the device housing can be
very hot!
5. If the device has to be mounted in any other
orientation, please do not hesitate to contact
[email protected] for more details.
Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation
> 50°C de-rate power by 4% / °C
> 60°C de-rate power by 1% / °C
No output power de-rating for the input
voltage from 100Vac to 132Vac & 200Vac to
264Vac
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
9
Assembly & Installation
ⒶSide Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The
power supply shall be mounted on minimum of 4 mounting holes using M4 screw maximum 5mm length (Refer to Fig. 4 on the
next page). This is to maintain a safety distance between the screw and internal components.
ⒷBase Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The
power supply shall be mounted on minimum of 4 mounting holes using M4 screw maximum 4mm length (Refer to Fig. 4 on the
next page).
ⒸConnector
ⒹThis surface belongs to customer’s end system or panel where the power supply is mounted.
Base Mounting (Horizontal) Base Mounting (Vertical) Side Mounting (Horizontal)
Fig. 2 Mounting Orientations
– Use flexible cable (stranded or solid) of AWG No. 14-12. The input/output connectors’ allowable current is 23A max per pin. User
should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at
the connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm.
– Recommended mounting torque of the product and its mounting accessories is 9~12Kgf.cm.
Fig. 4 Assembly Reference
Fig. 3 Mounting Hole Locations and the Safety Distance
Ensure the mounted device is kept at ≥ 4mm safety distance at all sides from other components and equipments. In addition, to ensure
sufficient convection cooling, always maintain a distance of ≥ 20mm from fan ventilated surfaces while the device is in operation.
Please insert an insulation sheet between the system and product, if the safety distance is < 4mm.
Safety Distance
D1 = 4mm Min.
D2 = 20mm Min.
Only use M4 screw ≤ 5 mm through the base mounting holes at
Ⓐ
.
This is to keep a safe distance between the screw and internal
components.

Only use M4 screw ≤ 4 mm through the base mounting holes at Ⓑ.
This is to keep a safe distance between the screw and internal
components.
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
10
Safety Instructions
– Must select correct AC input voltage before turning on (Refer to the “Device Description” on Page 5).
– If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further
information.
– The device is not recommended to be placed on low thermal conductive surface. For example, plastics.
– The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not
touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
– Do not touch the terminals while power is being supplied. Risk of electric shock.
– Prevent any foreign metal, particles or conductors from entering the device through the openings during installation.
It may cause electric shock, safety hazard, fire and/or product failure.
– Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device,
remove L and N connections before removing the Earth connection. The power supply must be mounted by metal screws onto a
grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded metal
surface.
Accessories
LM-01: Top Fixing Bracket
This bracket is used to fix the power supply onto a flat
surface from the top.
–
–
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
11
Functions
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Inrush Current
Inrush current is the peak, instantaneous, input current measured
and, occurs when the input voltage is first applied. For AC input
voltages, the maximum peak value of inrush current will occur
during the first half cycle of the applied AC voltage. This peak
value decreases exponentially during subsequent cycles of AC
voltage.
Dynamic Response
The power supply output voltage will remain within ±1000mVpp of
its steady state value, when subjected to a dynamic load from
10 to 50% and 50 to 100% of its rated current.
10 to 50% Load
50 to 100% Load
PMT Panel Mount Power
Supply
4.2V 252W 1
Phase
/ PMT-4V350W1A
□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (October 2014, Rev. 02)
12
Overload & Overcurrent Protections
The power supply’s Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds
105~135% of rated load current. In such occurrence, the VO
will start to droop and once the power supply has reached its
maximum power limit, the protection is activated and the power
supply will go into “Hiccup mode” (Auto-Recovery). The power
supply will recover once the fault condition of the OLP and
OCP is removed and IO is back within the specifications.
It is not recommended to prolong the duration of IO when it is
<105~135% but >100%, since it may cause damage to the
PSU.
Short Circuit Protection
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied,
the output current will operate in “Hiccup mode”, as shown in
the illustration in the OLP/OCP section on this page. The
power supply will return to normal operation after the short
circuit is removed.
Overvoltage Protection
The power supply’s overvoltage circuit will be activated when
its internal feedback circuit fails. The output voltage shall not
exceed its specifications defined on Page 3 under
“Protections”.
Over Temperature Protection
As mentioned above, the power supply also has Over
Temperature Protection (OTP). In the event of a higher
operating temperature at 100% load, the power supply will run
into OTP when the operating temperature is beyond what is
recommended in the de-rating graph. When activated, the
output voltage will go into bouncing mode until the temperature
drops to its normal operating temperature as recommended in
the de-rating graph.
Others
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in
electrical and electronic equipment”.
This product conforms to this standard.

This manual suits for next models

1

Other Delta Power Supply manuals

Delta D3000 User manual

Delta

Delta D3000 User manual

Delta DRP-24V240W2BN Instruction Manual

Delta

Delta DRP-24V240W2BN Instruction Manual

Delta LZ-32/R19 User manual

Delta

Delta LZ-32/R19 User manual

Delta sync 24V 100W Series Instruction Manual

Delta

Delta sync 24V 100W Series Instruction Manual

Delta PMR V320W1AT Series User manual

Delta

Delta PMR V320W1AT Series User manual

Delta AX Series User manual

Delta

Delta AX Series User manual

Delta PMT2 Series Instruction Manual

Delta

Delta PMT2 Series Instruction Manual

Delta HES Series User manual

Delta

Delta HES Series User manual

Delta FORCE-GT Series Instruction Manual

Delta

Delta FORCE-GT Series Instruction Manual

Delta PMH-100WCL Series User manual

Delta

Delta PMH-100WCL Series User manual

Delta PMC-12V050W1AA User manual

Delta

Delta PMC-12V050W1AA User manual

Delta PMT2 150 W Series Instruction Manual

Delta

Delta PMT2 150 W Series Instruction Manual

Delta DRP024V480W1AA Instruction Manual

Delta

Delta DRP024V480W1AA Instruction Manual

Delta LYTE II Instruction Manual

Delta

Delta LYTE II Instruction Manual

Delta PMC-24V100W1AA User manual

Delta

Delta PMC-24V100W1AA User manual

Delta DRP024V240W3BA Quick start guide

Delta

Delta DRP024V240W3BA Quick start guide

Delta CliQ DRP024V120W1AA Quick start guide

Delta

Delta CliQ DRP024V120W1AA Quick start guide

Delta GPS-850HB A A22 User manual

Delta

Delta GPS-850HB A A22 User manual

Delta CliQ II DRP024V060W1N Series Instruction Manual

Delta

Delta CliQ II DRP024V060W1N Series Instruction Manual

Delta LZ-8P/R19 User manual

Delta

Delta LZ-8P/R19 User manual

Delta PMU-13V155WC A Series User manual

Delta

Delta PMU-13V155WC A Series User manual

Delta MCS 3000 User manual

Delta

Delta MCS 3000 User manual

Delta PMC-24V035W1AA User manual

Delta

Delta PMC-24V035W1AA User manual

Delta DNPS01 User manual

Delta

Delta DNPS01 User manual

Popular Power Supply manuals by other brands

Thermaltake Toughpower Grand user manual

Thermaltake

Thermaltake Toughpower Grand user manual

Miyachi 875DP user manual

Miyachi

Miyachi 875DP user manual

Excelsys ultimod Designer's guide

Excelsys

Excelsys ultimod Designer's guide

GE Digital Energy LP 33 Series installation guide

GE

GE Digital Energy LP 33 Series installation guide

Siemens SITOP PSU100L 6EP1332-1LB00 manual

Siemens

Siemens SITOP PSU100L 6EP1332-1LB00 manual

EVGA 500B user manual

EVGA

EVGA 500B user manual

Lambda LZS-250-1 instruction manual

Lambda

Lambda LZS-250-1 instruction manual

DPI GEN IV BTL Series quick start guide

DPI

DPI GEN IV BTL Series quick start guide

Xantrex RS232-XHR operating manual

Xantrex

Xantrex RS232-XHR operating manual

Alarmtech PSV 1215-18 instruction manual

Alarmtech

Alarmtech PSV 1215-18 instruction manual

powersoft Duecanali Series user guide

powersoft

powersoft Duecanali Series user guide

ODA EX Series user manual

ODA

ODA EX Series user manual

MSTRONIC MSR-1231 user guide

MSTRONIC

MSTRONIC MSR-1231 user guide

Preen AFV-S Series user manual

Preen

Preen AFV-S Series user manual

Clayton Power LPS II Series Manual and safety instructions

Clayton Power

Clayton Power LPS II Series Manual and safety instructions

BT Lab Systems Mini 500 manual

BT Lab Systems

BT Lab Systems Mini 500 manual

Elenco Electronics XP-720K Assembly manual

Elenco Electronics

Elenco Electronics XP-720K Assembly manual

Omega DP6-MLPS1 instruction sheet

Omega

Omega DP6-MLPS1 instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.