PMT Panel Mount Power
Supply
5 V 50 W 1
Phase
/ PMT-5V50W1A
□
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (February 2022, Rev. 08)
Environment
Surrounding Air Temperature Operating -10°C to +70°C
Storage -25°C to +85°C
Power De-rating > 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / V
Operating Humidity 5 to 95% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft)
Shock Test (Non-Operating) IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms,
3 shocks for each 3 directions
Vibration (Non-Operating) IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 Grms);
20 min per axis for all X, Y, Z direction
Pollution Degree 2
Protections
Overvoltage 5.75-7.50 V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery)
Overload / Overcurrent 105-150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
Over Temperature Non-Latching (Auto-Recovery)
Short Circuit Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Protection Against Shock Class I with PE* connection
*PE: Primary Earth
Reliability Data
MTBF > 700,000 hrs. as per Telcordia SR-332
I/P: 100 Vac, O/P: 100% Load, Ta: 35°C)
Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C)
Safety Standards / Directives
UL/cUL recognized
CB scheme
BIS
UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)
UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)
IEC 60950-1, IEC 62368-1
IS 13152-1
CE In conformance with EMC Directive 2014/30/EU and Low
Voltage Directive 2014/35/EU
UKCA
In conformance with Electromagnetic Compatibility Regulations
2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation Input to Output 3.0 KVac
Input to Ground 1.5 KVac
Output to Ground 0.5 KVac