Dent Fix Equipment CURE RIGHT DF-CR004 Assembly instructions

Owner’s Manual &
Safety Instructions
WARNING
Read this manual before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

UV GUN |DF-CR004
www.dentfix.com2
The CURE RIGHT DF-CR004 rechargeable UV Curing Gun utilizes the latest ultra
high flux UV-A LED technology and is focused through custom designed optics to
provide a more ecient, faster, and safer cure light. Use for all automotive repair and
industrial curing needs utilizing ultraviolet light curable fillers, base coats, primers, top
coats, and clear coatings.
WARNING
Up to 1 second curing time for some UV primers.
Powerful irradiance with maximum UV-A intensity of
55,000 μW/cm² at 8 inches (20cm).
Successfully tested on UV paint products by all major paint
manufacturers.
Only emits UV-A. Does not emit UV-B or UV-C.
Ecient active built-in cooling system keeps the light cooler
to maintain optimum light output during extended use.
Ecient ultrasonic range finder function.
Wall-Mounted charging station provides more convenient
recharging process.
Features :
1. UVA protection glasses must always be
worn when using the DF-CR004 UV Gun .
2. To prevent permanent eye injury and blindness: Do
not direct light at eyes. Risk of eye injuries!
3. Do not point UV light directly at uncovered skin.
4. Do not open the device, except when
removing battery for disposal/recycling.
5. Keep away from children ! This is not a toy.
6. Do not operate in direct sun light or extreme
temperature conditions.
7. Inspect before every use; do not use or charge if the
unit is damaged or any parts are loose.
8. Do not set light lens down on any surface. Potential
burn risk.
9. Have your device serviced by a qualified repair person
using only identical replacement parts. This will
ensure that the safety of the device is maintained.
10. Only use the USB charger included to charge the
lamp – The use of a NON-recommended chargers
can cause damage to the lamp or potentially cause
a fire.
11. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
12. Contains Li-ion battery. Battery must be
recycled or disposed of properly. Do not open,
crush, heat above 140° F (60° C) or incinerate.

GENERAL SPECIFICATIONS
Light Source
LED Light Wattage
LED Wavelength
LED Lifetime
Battery Type
Battery Charging Time
Battery Charging Info
Running Time
Weight
Dimensions
Housing Material
Cooling System
Storage Temperature
High Power UV LED
40,000 Hours
λp= 395 ±5 nm
66 Watts
Li-ion 11.1V - 5200mAh, 57.72Wh
3 Hours
2 Lbs (0.9 Kg)
90 Minutes in Total (Max 10 minutes each use)
6-1/4”x 8-3/4“x 3” (159 x 223 x 77mm)
Aluminum + Polyamide
Thermal Management System enhanced with fan
-4°F ~ 122°F (-20° C ~ +50° C)
AC 100 - 240V ~ 15V 1.5A
www.dentfix.com 3
1
2
3
4
5
TECHNICAL SPECIFICATIONS
Ultrasonic Range Finder
Temperature Control Function
Safety Protection Function
Curing Distance
Curing Zone Dimensions
Curing Time
Average Irradiance
Peak Irradiance
Max 160” (400cm)
Working ≤ 194° F (90° C)
Double click ≤ 100ms
2” (50mm)
4” x 4” (100mm x 100mm)
5~12 seconds*
135 mW/cm2
200 mW/cm2
8” (200mm)
8” x 8” (200mm x 200mm )
30~80 seconds*
36 mW/cm2
55 mW/cm2
1. UV Curing Light DF-CR004
2. Plug Adapter
3. 15V1.5A Universal Charger
4. Wall-Mounted Charging Station
5. UV Protection Glasses
ACCESSORIES LIST
*This is laboratory data only for reference. The curing time may vary according to the paint product type, working conditions, the curing
process and/or other factors.
UV GUN |DF-CR004

General Operation
Put the UV protection glasses on and do not
remove them until the unit is safely powered o.
Press the Main Switch for more than 1 second to
Power ON or OFF. Press the Light Trigger Switch
to activate & deactivate the UV light.
Accidental Triggering Protection System
Double click the Main Switch to lock or unlock
the light when the power and display screen is o.
Automatic Run Time Procedure
Press Set Button once to set the number of desired
minute(s). The minute timer will start flashing.
Increase/decrease desired run time by pressing the
or button (Max run time 10 minutes).
Press button again to enter the desired seconds.
Seconds display will start flashing. Increase/decrease
desired run time by pressing the or button (Max
run time 60 seconds).
By pressing and holding the or button
minutes/seconds are adjusted faster.
Press button to confirm the setting procedure or auto
set after 5 seconds without adjustment.
The countdown will start after the trigger is pressed and
light is on.
The countdown can be manually stopped by pressing the
trigger , simultaneously turning o the light. Pressing
the trigger again will resume the countdown and turn
the light back on.
The last countdown setting will be remembered when
powered o using the Main Switch.
The light will be automatically switched o when the
countdown display reads " ".
The light will automatically power o after 60 minutes
without operation.
DF-CR004 OPERATION
www.dentfix.com4
UV GUN |DF-CR004
Battery Display Run Time Count Down
Set
Button
Run Time Setting Decrease
Main Switch
Light Trigger
Switch
Run Time
Setting
Increase
Ultrasonic Range Finder Distance

TEMPERATURE CONTROL & PROTECTION SYSTEM
395nm UV LED
Ultrasonic
Range Finder
Light Trigger
Switch
www.dentfix.com 5
-Press button for more than 5 seconds when the
DF-CR004 is powered on . The display screen will
show the current temperature of the light .
-DF-CR004 has a built-in cooling system that will be
automatically powered on after reaching a
temperature higher than 104°F (40°C).
- Automatic active cooling system engages when light
light temperature reaches a range between 167°F
(75°C) to 194°F (90°C) . The UV Cure Gun can be
used during this active cooling, but a buzzer alarm
will sound every 30 seconds until the temperature
reaches below 122°F (50°C).
1
Press & hold
for 5 seconds
the display screen will
show the current
temperature of the light.
Press & hold
for 5 seconds
the display screen will
show the current
temperature of the light.
1
2
2
-The UV Gun will automatically switch o, when the
light temperature is above 194°F (90°C) . The
active cooling system will keep running until the
temperature is below 122°F (50°C).
-The light will not work until the cool down is
complete.
- For longer working life and to maximize
performance eciency, the light should be allowed
to cool down for few minutes after each use.
UV GUN |DF-CR004

CHARGING PROCEDURE
ULTRASONIC RANGE FINDER FUNCTION
www.dentfix.com6
Put the corresponding adapter onto the
15V 1.5A universal charger.
Switch the light o and put it inside the
Wall-Mounted charging station. Connect
the charging station with 15V 1.5A
universal charger.
The charging port on the handle can also be
used when the charging station is not
available.
Wall-mounted Charging Station
Wall-mounted
Charging Station
Position hole
Universal Charger The charging port on the handle
Adapter
There will be a digital battery indicator on the
display screen showing the battery level during charging.
The battery indicator will flash during charging. After
charging is complete the battery indicator will remain
solid and an alarm buzzer will sound 3 times.
When connected to charger, if the battery indicator does
not light up, please remove from the charger and try
again.
This
Side UP
Always only use the charger recommended by
CURE RIGHT to charge the lamp. The use of a
non-recommended charger can lead to overheat-
ing or potential fire.
Charge the DF-CR004 for 4-5 hours before
first use and if stored for longer than 3 months.
UV GUN |DF-CR004
DF-CR004 has a built-in ultrasonic range finder, ranging distance is 1.5” to 157±1.2” (4-400±3cm).
The display screen will show if distance is smaller than 1.5” (4cm) or longer than 157’ (400cm).

SAFETY INSTRUCTIONS
Do not use the device if there is damage to the
housing, plug or cable.
Do not open the device ! There is a risk of sho-
circuit.
Repairs on the device may only be carried out by
commissioned and trained person, please contact
Dent Fix Equipment.
Carry out cleaning tasks only when the unit is
unplugged from power!
Protect the baery against heat caused by excessive
sunlight or re. Danger of explosion.
Keep away from excessive moisture. Do not immerse
in water.
If the baery is damaged or not charged correctly,
dangerous uids may leak from the baery.
ENVIRONMENTAL PROTECTION
The device should not be discarded in the normal
household waste under any circumstances.
Dispose of the device via an authorized disposal
center or your communal waste disposal facility.
Observe the current applicable regulations. Contact
your waste disposal facility in the event of any
doubt.
www.dentfix.com 7
WARRANTY
The device has a one year WARRANTY against
faulty workmanship or materials. The guarantee
does not apply to damage to the device arising
through a failure to comply with the operating
instructions.
* Subject to technical changes. We assume no liability for printing errors.
Avoid contact with these uids, they may lead to skin
irritations or severe burns. If you happen to come in
contact with these uids, rinse o immediately with
soap and water. Seek medical help immediately if the
uids make contact with your eyes or mouth.
Lamp lens will heat up and become hot aer being on
for a sho period. DO NOT TOUCH THE LAMP LENS
TO ANY SURFACE AFTER BEING ON or AFTER BEING
TURNED OFF UNTIL LENS IS COOLED.
RISK OF EYE INJURY ! DO NOT direct light at eyes or
permanent eye injury and blindness may occur.
ALWAYS USE UV EYE PROTECTION!
Dispose of all packaging materials via an environ-
mentally friendly disposal facility.
Rechargeable baeries must not be
disposed of in the household waste.
Return used rechargeable baeries to
a baery collection facility.
UV GUN |DF-CR004
DO NOT RETURN TO POINT OF PURCHASE IF
DEFECTIVE.
CONTACT DENT FIX EQUIPMENT :
Call (310) 349-1940 OR Email info@dentfix.com

Dent Fix Equipment
(310) 349-1940
www.dentfix.com
info@dentfix.com
Gardena, California
Table of contents
Other Dent Fix Equipment Tools manuals