A5201 SHINE – lotto/batch 10/06
1. DESCRIPTION
SHINE is a machine suitable to carry out grinding and polishing operations of the metals in
the dental field. It has been expressly designed with dual speed option in order to avail of low
average (1.400 rpm) working condition assuring a good removal effect without overheating
the surfaces and of a high-average speed (2.800 rpm) assuring a perfect polishing.
Abrasive grinding wheels, brushes and felts can be inserted on the cone-shaped spindle.
Plastic splash protection guards are recommended avoiding the residues to be propelled
outside.
An electromagnetic safety switch prevents the machine from starting up accidentally after a
voltage drop. In addition to this, it is necessary to wear individual protection devices such as
glasses, gloves and mask to protect your eyes from the rebound of shavings, your hands
from the possibility to touch accidentally the parts in motion and your breathing apparatus
from the possibility to inhale dust particles.
2. TECHNICAL REFERENCE REGULATIONS AND TEST PROCEDURES
The polishing unit is mass-manufactured by C.I.E. DENTALFARM in compliance with
technical and safety rules in force, as provided for by the 89/392 EEC Community Directive
on machinery.
Careful inspection and full routine testing is carried out singularly on each machine which is
furtherly tested by an automatic test installation (Model TS48 Elektrotech. Laboratorium
Postfach D-7015 KORNTAL 1) carrying out in sequence:
Dielectric Strength Test
Test on the Protection Conductor
Insulation Resistance Test
Short Circuit Test
and it prints a report assuring compliance with the fixed limits.
3. GENERAL PRECAUTIONS
Read carefully the present manual before carrying out any starting, operating or
maintenance operation on the machine
Safety of the User depends on the skill ability, on the good sense and on the caution
when using the machine; for this reason, it is of utmost importance to know in detail
the allocation and the function of all the controls
The final User of the machine is a skilled and well trained professional and not merely
an occasional worker
Check regularly the parts which tend to wear out due to the specific working conditions
Do not tamper the electrical wiring system of the machine
The built-in safety mechanisms shall in no way be removed or modified
Do not allow unauthorised persons to try to repair the machine
Do not utilise petrol, solvents or any other inflammable fluids to clean some parts of
the machine – use exclusively non-toxic and non-inflammable products available on
the market for this specific purposes.