9. TECHNICAL SPECIFICATIONS
Description
Width 420 mm (600 mm with splash guards)
Depth at the base 205 mm (290 mm with splash guards)
Height 250 mm (280 mm with splash guards)
Net and gross weight 9,0 kg – 10,3 kg
Line voltage 230 v AC – 50/60 Hz
Running voltage 230 v AC
Absorption 500 W
Tool min diameter hole 5.0 mm
Tool max diameter hole 11,0 mm
10. DEMOLITION AND WASTE DISPOSAL
According to International regulations, this unit has been classified as AEE
(electric and electronic device, whose correct operation depends on electric
currents and electromagnetic fields) and as a consequence, at the end of its
lifetime, it can not be treated as normal waste material but it must be disposed
separately, complying with the Directive 2002/96/CE.
C.I.E. DENTALFARM s.r.l.
Via Susa, 9/a - 10138 TORINO - ITALY
TECHNICAL-COMMERCIAL SERVICE (+39) 011/4346588
AFTER-SALE SERVICE 011/4346632
FAX 011/ 4346366
E-mail: [email protected]
Website: www.dentalfarm.it
POLISHING UNIT
SHINE
INSTRUCTION AND MAINTENANCE MANUAL
A5201 SHINE – lotto/batch 10/06
1. DESCRIPTION
SHINE is a machine suitable to carry out grinding and polishing operations of the metals in
the dental field. It has been expressly designed with dual speed option in order to avail of low
average (1.400 rpm) working condition assuring a good removal effect without overheating
the surfaces and of a high-average speed (2.800 rpm) assuring a perfect polishing.
Abrasive grinding wheels, brushes and felts can be inserted on the cone-shaped spindle.
Plastic splash protection guards are recommended avoiding the residues to be propelled
outside.
An electromagnetic safety switch prevents the machine from starting up accidentally after a
voltage drop. In addition to this, it is necessary to wear individual protection devices such as
glasses, gloves and mask to protect your eyes from the rebound of shavings, your hands
from the possibility to touch accidentally the parts in motion and your breathing apparatus
from the possibility to inhale dust particles.
2. TECHNICAL REFERENCE REGULATIONS AND TEST PROCEDURES
The polishing unit is mass-manufactured by C.I.E. DENTALFARM in compliance with
technical and safety rules in force, as provided for by the 89/392 EEC Community Directive
on machinery.
Careful inspection and full routine testing is carried out singularly on each machine which is
furtherly tested by an automatic test installation (Model TS48 Elektrotech. Laboratorium
Postfach D-7015 KORNTAL 1) carrying out in sequence:
Dielectric Strength Test
Test on the Protection Conductor
Insulation Resistance Test
Short Circuit Test
and it prints a report assuring compliance with the fixed limits.
3. GENERAL PRECAUTIONS
 Read carefully the present manual before carrying out any starting, operating or
maintenance operation on the machine
 Safety of the User depends on the skill ability, on the good sense and on the caution
when using the machine; for this reason, it is of utmost importance to know in detail
the allocation and the function of all the controls
 The final User of the machine is a skilled and well trained professional and not merely
an occasional worker
 Check regularly the parts which tend to wear out due to the specific working conditions
 Do not tamper the electrical wiring system of the machine
 The built-in safety mechanisms shall in no way be removed or modified
 Do not allow unauthorised persons to try to repair the machine
 Do not utilise petrol, solvents or any other inflammable fluids to clean some parts of
the machine – use exclusively non-toxic and non-inflammable products available on
the market for this specific purposes.
A5201 SHINE – lotto/batch 10/06
8. EXPLODED DRAWING AND SPARE-PART LIST SHINE (A5201)
NO. CODE DESCRIPTION
1 5201014 RIGHT CONE-SHAPED SPINDLE
1 5201015 LEFT CONE-SHAPED SPINDLE
2 5201013 SPINDLE RELEASE LEVER
3 5201011 SHIELD
4 5201010 BODY
5 5101024 FAIRLEAD
6 5201017 ROTOR
7 5201019 SHIELDED BEARING
8 5101025 PROTECTION FEET
9 5201018 CONDENSER
10 5201012 CLOSING SHEET
11 5101022 BIPOLAR SWITCH
12 5201016 STATOR
13 5201021 SWITCH FRAME
14 5201022 SWITCH LEVER
15 5101023 ELECTRIC CABLE
16 5201001 SHINE MARK LABEL
17 5201020 ELECTRIC CHANGE-OVER SWITCH
4. INSTALLATION INSTRUCTIONS
/!\
ATTENTION
Installation of this machine is quite easy but it must be carried out paying
utmost attention in order to avoid any mistake which may originate
problems during operation, inconvenience or even damages.
1. Place the machine on a suitable support table, in a stable position
2. Connect the feeding cable to an approved 220v AC - 50Hz socket with ground connections
3. Place aside the two splash guards
/!\
ATTENTION
We remind that the working process originates dust particles which in no
way must be either inhaled or freely wasted; some particles may be
propelled outside and there are some parts in motion which can not be
fully covered. Pay always utmost attention and fit yourself with
adequate individual protection systems.
4. Assemble the cone-shaped spindles, complying with the preset position (left – right)
5. Pressure-insert the necessary rotating instruments.
5. INSTRUCTIONS FOR USE
1. Press the white electromagnetic switch placed on the base to switch on the machine
2. Select the required speed
3. Slightly approach the pattern to the rotating tool
/!\
ATTENTION
The rotating tools are the only parts susceptible to cause damages,
therefore utmost care must be paid during operation. Never bring
your hands too close to the parts in motion and avoid grinding too
small components which are particularly hard to be hold and they
could get entangled or forced in such a way to endanger your
fingers.
4. When you have finished to work, push the proper switch to switch off the machine; the
motor is no more fed but the shaft will continue turning for a few seconds due to the inertial
force.
A5201 SHINE – lotto/batch 10/06
6.MAINTENANCE
/!\
ATTENTION:
Before carrying out any maintenance operation inside the machine or
any technical to the connections, disconnect the electric cable from the
socket; in such a way the machine will be completely insulated from the
electric wiring system.
If you still have any doubts, difficulties or any possibility of mistake,
contact our Technical Service to avoid any risks or damages.
Replacement of the worn out rotating instruments
When it is necessary to replace the instruments fitted on the cone tips, it will be necessary to
press slightly behind the metallic ring inside the discs, so as to release it from the connection
point. If this operation results to be difficult, even in consideration of the position and due to
the reduced room available, we recommend to turn the extraction levers of the spindle and
work more safely and in a more comfortable way by grasping the parts themselves.
Lubrication or bearing replacement
The driving shaft revolves on shielded and protected bearings which lubricated with grease.
Usually it is not necessary to restore the grease since the specific type of bearings has a
long-life period of usage. In case the quantity of daily work and the effort requested to the
machine excessively wear out the bearings, you can proceed as follows:
1. rotate the pin unlocking levers and remove them
2. unscrew the three screws fixing the shield (first the right, then the left one)
3. grease or replace the bearing
4. reassemble.
7. WIRING DIAGRAM
Symbol Description
IG Main switch
CO 12A - 8 contact change-over switch
C 450v 25µF motor starting up condenser
M 230v 50/60Hz 500W motor

Other dentalfarm Dental Equipment manuals

dentalfarm SHINING BOX Operating instructions

dentalfarm

dentalfarm SHINING BOX Operating instructions

dentalfarm Photopol User manual

dentalfarm

dentalfarm Photopol User manual

dentalfarm MICRA Evoluzione Operating instructions

dentalfarm

dentalfarm MICRA Evoluzione Operating instructions

dentalfarm PF PRO User manual

dentalfarm

dentalfarm PF PRO User manual

Popular Dental Equipment manuals by other brands

Ivoclar Vivadent 747825BE operating instructions

Ivoclar Vivadent

Ivoclar Vivadent 747825BE operating instructions

Denjoy DY-GP Plus user manual

Denjoy

Denjoy DY-GP Plus user manual

EMS AirFlow Master Piezon Operation instructions

EMS

EMS AirFlow Master Piezon Operation instructions

Renfert Pillo instruction manual

Renfert

Renfert Pillo instruction manual

Sendoline S1-E operating instructions

Sendoline

Sendoline S1-E operating instructions

Detax mollosil Instructions for use

Detax

Detax mollosil Instructions for use

DentalEZ Aeras Star 500 Elite Handpice installation guide

DentalEZ

DentalEZ Aeras Star 500 Elite Handpice installation guide

Aseptico ADU-17X Express II Operation and maintenance instruction manual

Aseptico

Aseptico ADU-17X Express II Operation and maintenance instruction manual

Aseptico ADU-07A Operation & instruction manual

Aseptico

Aseptico ADU-07A Operation & instruction manual

Bien Air iOptima Instructions for use

Bien Air

Bien Air iOptima Instructions for use

BEYES Accurator A2 Instructions for use

BEYES

BEYES Accurator A2 Instructions for use

DCI Edge SERIES 5 Instructions for use

DCI Edge

DCI Edge SERIES 5 Instructions for use

Ultradent GEMINI EVO 810 manual

Ultradent

Ultradent GEMINI EVO 810 manual

KaVo ESTETICA E30 Short instructions for use

KaVo

KaVo ESTETICA E30 Short instructions for use

Myray Hyperion X9 Pro instructions

Myray

Myray Hyperion X9 Pro instructions

SDS Cuspidor 1655 Installation, operation, maintenance, & troubleshooting

SDS

SDS Cuspidor 1655 Installation, operation, maintenance, & troubleshooting

TPC L700 Lucent Dental Light Operation and service manual

TPC

TPC L700 Lucent Dental Light Operation and service manual

W&H proxeo TWIST PL-40 HW Instructions for use

W&H

W&H proxeo TWIST PL-40 HW Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.