Denver BSS-10610 User manual

User guide for installing the
Balcony solar system
facebook.com/denver.eu
Please read this guide before installing the product. Keep
the assembly instructions for future reference.

1. Safety information
Warning! Dangerous electrical voltage!!
Please observe all precautions and warnings when handling
electricity. Before installation, use and maintenance, be sure to
read the manual and follow the instructions and safety
information in it.
Please read this guide before beginning the assembly of your
Denver solar system with the SMI-601 Inverter and SOP-16600
Solar panels. We cannot assume any liability or guarantee for
damages caused by improper handling. Failure to do so can result
in serious health consequences, such as electric shocks and other
life-threatening injuries.
Please keep the assembly instructions for future reference.
1. This product is not a toy. Keep it out of reach of children.
2. Keep product out of the reach of children and pets to avoid chewing and swallowing.
3. This device is not intended to be used by persons (including children) with limited physical, sensory
or mental abilities.
4. Please check the micro inverter, the cables, and solar panels for visible damages before starting to
connect the system. If visible damages show, please contact our support before continuing.

5. Make sure that the existing electrical installation is suitable for using this solar system. It is the
responsibility of the end user to check this in advance before use.
6. This product has been created especially for Germany/Austrian market. If this Solar inverter system
is installed in other countries, you need to make sure that the product complies with the regulation
in this country. In some countries you need to have a licensed electrician to install this system in
your house. It is the user responsibility to know the regulation in the country where it is installed to
avoid any potential risks.
7. This micro inverter and solar power panels must be installed in households with grounding in the
power outlet. Also make sure you have power plug with grounding. If you are in doubt if you have
grounding in the power outlet, then please contact a licensed Electrician before installing. Please
notice that the grounding in the Schuko power plug only works in a Schuko power outlet with
grounding. If using in a normal non Schuko power outlet, then you need and adaptor with
grounding fitting your outlet. Failure to have grounding can result in serious health consequences,
such as electric shocks and other life-threatening injuries.
8. Please notice that we also recommend that you ground the solar panels to avoid potential damages
for your solar panels in thunderstorms. A licensed electrician can help you with this. This is not
included.
9. Repairs and maintenance may only be carried out by qualified personnel. Never open the product
and make repair yourself. Do not open the electronic devices. This can lead to serious security
problems, health hazards or equipment damage. Also, warranty is void if doing so.
10. Do not make modifications to any components of the PV module (diode, junction box, plug
connectors or others). Warranty is void if doing so.
11. In the event of irregularities or unusual behavior (odor, smoke, etc.), pull out the mains plug and do
not use the device before you have talked with our support.
12. Only use the accessories and cables that comes with this product.
13. Do not install the micro inverter near flammable, explosive, corrosive or damp sources.
14. Ensure that the circuit is disconnected from power before starting the cleaning the product to
avoid electrical shocks and other life-threatening injuries. Please notice that the connectors are not
waterproof when unmated. So, avoid cleaning when cables are unmated. Do not use abrasive, De-
greasers, electric cleaners or corrosive solutions containing acid, alkali, acetone, or industrial
alcohol for cleaning. We recommend the following to be used: Water with low mineral content,
Near neutral pH water.
15. Periodically inspect the system to check the integrity of all wiring and support. Also check for bolts
are fastened and not loose.
16. Check applicable building codes to ensure that the construction or structure (balcony, roof, facade,
support, etc.) can bear the module system load.

17. Check with your landlord and local authority if setting up a solar panel system is allowed.
18. Avoid touching the inverter under load as the surface is hot and burns can occur.
Safety for the solar panels
Warning! Dangerous electrical voltage!!
Photovoltaic modules produce electrical voltage/current when
exposed to light. Please observe all precautions and warnings
when handling electricity. Before installation, use and
maintenance, be sure to read the manual and follow the
instructions and safety information in it.
SAFETY WARNING
- Cleaning activities create risk of damaging the modules and array components, as well as increasing the
potential electric shock hazard.
- Cracked or broken modules represent an electric shock hazard due to leakage currents, and the risk of
shock is increased when modules are wet.
- Before cleaning, thoroughly inspect modules for cracks, damage, and loose connections.
- The voltage and current present in an array during daylight hours are sufficient to cause a lethal
electrical shock.
1. Repairs may only be carried out by qualified persons.

2. All plugs are only connected if they are dry and clean! Connectors are not waterproof when
unmated.
3. All work on cables and inverters must be carried out with caution!
4. Do not carry out installation work in strong winds.
5. Do not stand, step, walk and / or jump on modules under any circumstances. Localized heavy loads
may cause severe micro-cracks at cell level, which in turn may compromise module reliability and
void warranty.
6. Do not drop or place objects (such as tools) on the modules.
7. Do not lift modules by their wires or junction box, lift them by the frame.
8. Do not place excessive loads on the module or twist the module frame.
9. Do not use sharp instruments on the modules. Particular care should be taken to avoid module
back sheets being damaged by sharp objects, as scratches may directly affect product safety.
10. Do not install modules near open flames or flammable materials
11. Do not immerse modules in water or constantly expose modules to water
(Either fresh or salt) (i.e., from fountains, sea spray).
12. Exposing modules to salt (i.e., marine environments).
13. Do not make modifications to any components of the PV module (diode, junction box, plug
connectors or others).
14. Regular maintenance is required to keep modules clear of snow, bird droppings, seeds, pollen,
leaves, branches, dirt spots, and dust.
15. If the module has become soiled, wash with water and a non-abrasive cleaning implement (sponge)
during the cool part of the day. Do not scrape or rub dry dirt away, as this may cause micro
scratches.
16. Periodically inspect the system to check the integrity of all wiring and support. Turn off power
before doing this. Also periodically check that the bolts for mounting the solar panels are fastened
and not loose.
17. Cracked or broken modules represent an electric shock hazard due to leakage currents, and the risk
of shock is increased when modules are wet. Before cleaning, thoroughly inspect modules for
cracks, damage, and loose connections.
18. Ensure that the circuit is disconnected before starting the cleaning procedure as contact with
leakage of electrically active parts can result in injury.
19. Do not use abrasive or electric cleaners on the module.
20. Do not use de-greasers on the module.
21. Do not use cleaning corrosive solutions containing acid, alkali, acetone, or industrial alcohol.
22. Dirt must never be scraped or rubbed away when dry, as this will cause micro-scratches on the
glass surface.
23. Noticeable dirt must be rubbed away by gentle cleaning-implement (soft cloth, sponge or brush
with soft bristles). Ensure that brushes or agitating tools are not abrasive to glass, EPDM, silicone,
aluminum, or steel. Conduct the cleaning activities avoiding the hottest hours of the day, in order
to avoid thermal stress on the module.
We recommend the following to be used:
Water with low mineral content
Near neutral pH water
The maximum water pressure recommended is 4 MPa (40 bar)
This manual suits for next models
3
Table of contents
Other Denver Inverter manuals
Popular Inverter manuals by other brands

BARRON
BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer
Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil
electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar
Silicon Solar TPS555-1230 instruction manual

Mission Critical
Mission Critical Xantrex Freedom SW-RVC owner's guide

HP
HP 3312A Operating and service manual