Desco 19325 Service manual

TB-3060 Page 1 of 4 © 2012 DESCO INDUSTRIES, INC.
Employee Owned
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com
Made in the
United States of America
Full-Time Continuous Monitor
Installation, Operation and Maintenance
Description
Leading companies use continuous monitors as a cost
effective component in satisfying the paragraph 6.1.3
Compliance Verification Plan requirements of ANSI/
ESD S20.20. The Desco Full Time Continuous Monitor
provides 100% monitoring of both the operator and the work
surface. This unit provides continuous monitoring of:
• One user wearing a wrist strap
• ESD worksurface
• Ground
• AC outlet
Note: Worksurface must have a conductive layer such as
Dual Layer Rubber, Dissipative 3-Layer Vinyl or Micastat®
Dissipative Laminate with conductive buried layers. Desco
Continuous Monitors are not recommended for use with
homogeneous matting.
If the unit detects that the elements are outside industry
standards, the continuous monitor will alarm woth both an
audible alarm and an illuminated red LED to notify the user
of a problem.
Unlike many units, the Full Time Continuous Monitor also
continuously verifies ground (AC outlet ground). When the
Power Cord is plugged in, a self-test runs automatically.
If the AC outlet is wired incorrectly, both red LEDs will
illuminate and the audible alarm will sound. The unit has an
additional ground point for a user or supervisor.
The Full Time Continuous Monitor is available in one
model:
April 2012
Figure 1. Desco Full-Time Continuous Monitor
Item Input Voltage Power Cord
19325 120VAC North America
ADVANTAGES OF WORKSTATION CONTINOUS
MONITORING OVER PERIODIC TESTING
Many customers are eliminating periodic testing and are
utilizing workstation continuous monitoring to better ensure
that their products were manufactured in an ESD controlled
environment. Full time workstation continuous monitoring is
superior to pulsed monitoring as well as periodic testing, and
can save a significant amount of money in testing costs and
rejected products. Periodic testing detects failures after
ESD susceptible products have been manufactured. The
costs of dealing with the resulting catastrophic or latent
defects can be considerable. Full Time Continuous Monitors
eliminate the need for users to test wrist straps and log the
results; by their function, these monitors satisfy the ISO
9000 and ANSI/ESD S20.20 Paragraph 6.2.2.2. test logging
requirements. Per ESD-S1.1 paragraph 6.1.3 Frequency
of Functional Testing “Daily (Wrist Strap) testing may be
omitted if constant monitoring is used.”
Per ESD Handbook TR 20.20 paragraph 5.3.2.4.4 Test
Frequency “Because wrist straps have a finite life, it is
important to develop a test frequency that will guarantee
integrity of the system. Typical test programs recommend
that wrist straps that are used daily should be tested daily.
However, if the products that are being produced are of
such value that knowledge of a continuous, reliable ground
is needed, and then continuous monitoring should be
considered or even required.”
WAVE DISTORTION DETECTION TECHNOLOGY
PROVIDES TRUE 100% CONTINUOUS MONITORING
Desco utilizes wave distortion technology for the Full Time
Continuous Monitor, which is an Impedance type monitor.
Per ESD TR12-01 section 2.2 Impedance (or single wire)
constant monitors “The capacitance type of monitor is
also known as an impedance monitor. They both work on
the same theory, however the impedance monitor uses
a detection circuit designed to reduce false alarms and
eliminate adjustments. ‘Single Wire’ or ‘impedance type’
monitors use the phase difference between current and
voltage to detect changes in impedance of the cord, band
and person. A very low AC voltage is used for constant
sensing. Any standard wristband and coiled cord can be
used.”
Thus the wave distortion circuitry monitors current/voltage
phase shifts and provides true 100% continuous monitoring.
Electrical current will lead voltage at various points due to
the combinations of resistance and capacitive reactance.
By monitoring these “distortions” or phase shifts, the wave
distortion Full Time Continuous Monitor will reliably determine
if the circuit is complete.
TECHNICAL BULLETIN TB-3060
Distributed by:
All-Spec Industries
5228 US Hwy 421 N www.all-spec.com PH: 800-537-0351

TB-3060 Page 2 of 4 © 2012 DESCO INDUSTRIES, INC.
Employee Owned
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com
Wave distortion technology can be referred to as “vector
impedance monitoring”. This description is valid as the
wave distortion technology measures the impedance at the
monitored banana jack and looks for changes in either the
capacitance or resistance of the circuit which includes the
wrist strap and its wearer. It uses filtering and time domain
sampling to filter out false signals caused by voltage offsets,
60 Hz fields and other electro-magnetic and electrostatic
interference.
In normal factory environments, and with persons whose
capacitance with respect to ground is within design limits (5
feet tall 90 pound person to 6 foot 5 inch 250 pound person),
the Full Time Continuous Monitor cannot be “fooled”. It
will provide a reliable alarm only when the wrist strap or
work surface becomes dysfunctional or unsafe according
to accepted industry standards. The Full Time Continuous
Monitor is drift-free and designed to be insensitive to the
effects of squeezing or stretching the coil cord.
ADVANTAGES OF WAVE DISTORTION AND
SINGLE-WIRE TECHNOLOGY
The Desco Full Time Continuous Monitor allows the use
of any standard, single-wire wrist strap and coil cord. The
monitor / wrist strap / cord system life-cycle costs are by far
lower than alternative systems which require dual-wire cords
and special wrist straps. Dual-wire cords are expensive and
are the weak link of the system, the most likely component
to need replacement. Over a five year period, this can make
the dual-wire system three to five times as expensive as
a system utilizing single-wire wrist straps and cords. See
Calibration section on page 4 to minimize life cycle costs.
The dictionary defines constant as uniform and unchanging,
and continuous as uninterrupted. None theless, some
dual-wire resistance monitors utilize a pulsed test current and
do not really provide continuous monitoring. For example,
during each 2.2 second pulse cycle of a leading “constant”
resistive monitor, electrical current is pulsed for only 0.2
seconds followed by an unmonitored interval of 2 seconds.
This leaves the user/wrist strap unmonitored for over 90% of
each cycle. Damaging static charges can easily occur in the
portion of the time in between the pulses. The off period of
2 seconds equals 2 billion nanoseconds, and “it takes only
about 25 volts applied for 100 nanoseconds to blow most
memories or microprocessors”.* Some dual-wire systems do
not reliably meet all industry specifications, as the cords may
not meet the EOS/ESD S-1.0 paragraph 4.1.6 one to five
pound “breakaway force” requirement for operator safety.
By using the reliable wave distortion technology to determine
if the circuit is complete, there are no false alarms. There
is no need to adjust or tune the monitor to a specific user
or installation. The miniscule amount of electrical current
(less than 1 volt coil cord signal) required to generate the
waveform has never caused reported skin irritation and is
extremely safe for use in voltage sensitive applications such
as disk drive manufacturing.
Packaging
1 Full-Time Continuous Monitor
1
Power Cord
1 Mat Monitor Cord (Black)
1 Ground Cord (Green and Yellow)
2 Push and Clinch Snaps
1 Hook and Loop Fastener Strip
1 Certificate of Calibration
Features and Components
A. IEC Power Cord Inlet: Connect the power cord here.
B. I/O Signal Output: Contact Desco Customer Service for
more information
C. Monitored Ground Terminal: Grounds the worksurface
mat. Connect the green and yellow ground cord here.
D. Monitored Mat Terminal: Monitors the worksurface mat.
Connect the black mat monitor cord here.
E. Mat Ground LEDs: When the green LED is illuminated,
the worksurface mat is properly grounded. When the red
LED is illuminated and the alarm sounds, the worksurface
mat is not properly grounded.
F. Operator Ground LEDs: When the green LED is
illuminated, the operator is properly grounded. When the
red LED is illuminated and the alarm sounds, the operator
is not properly grounded.
G. Auxiliary Ground: Unmonitored banana jack ground
point.
D
Figure 2. Full-Time Continuous Monitor features and
components
AB C
E
F
G H I
Distributed by:
All-Spec Industries
5228 US Hwy 421 N www.all-spec.com PH: 800-537-0351

TB-3060 Page 3 of 4 © 2012 DESCO INDUSTRIES, INC.
Employee Owned
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com
H. 4mm Parking Snap: When touched by the operator,
this snap will deactivate the alarm for six seconds. This
allows time for the operator to disconnect the coil cord from
the wrist band and park it on this snap. While parked, the
coil cord disables the alarm, allowing the operator to leave
the workstation. The OPERATOR GROUND LED will
remain off while the cord is parked. Upon returning and
removing the coil cord from the parking snap, the operator
has six seconds to hook up to the wrist band before the
alarm sounds.
I. Monitored Operator Jack: Where the operator inserts the
wrist cord plug.
Installation
Remove the monitor from its packaging and inspect for any
shipping damage. Confirm that the work surface is 1 x 10E7
ohms or less and has a conductive layer such as Dual Layer
Rubber, Dissipative 3-Layer Vinyl, or Micastat® Dissipative
Laminate with conductive buried layers.
Figure 3. Installing the Full-Time Continuous Monitor
Worksurface
10mm snaps need to pierce and clinch
bottom side of mat. Snaps need to be
12-72 inches apart.
6. Route the green ground cord to the monitor’s green
terminal block labeled GND.
7. Connect the power cord to the monitor’s power jack, and
connect the other end to a proper voltage source.
Operation
When the Full-Time Continuous Monitor is installed to an
ESD protective worksurface and grounded via a power
cord, the green MAT GROUND LED and red OPERATOR
GROUND LED should illuminate. The monitor takes 6
seconds to activate its alarm circuitry when first powered.
• Correct wiring of the outlet is confirmed when the monitor
is plugged in.
• The worksurface resistance is measured between the two
snaps installed to the mat worksurface.
USING THE MONITOR
1. Plug a wrist strap cord, not attached to the wristband, into
the monitored banana jack labeled OPERATOR on the
front of the unit. This automatically activates the selected
operator channel. The red operator LED should illuminate,
and the audible alarm will sound after the activation
period.
2. Remove the charges from your body by making contact
with a properly grounded ESD worksurface. Snap the
cord to the wristband, and fit it snugly onto your wrist.
This should silence the audible alarm and cause the
OPERATOR GROUND LED to switch from red to green.
1. Locate a nearby power outlet and test it for proper wiring
and grounding. We recommend the Desco AC Outlet
Analyzer to verify proper wiring and ground.
2. The Full-Time Continuous Monitor may be mounted to
a convenient location using the included hook and loop
strip. It is normally mounted toward the front edge of a
workstation where the LEDs are easily visible.
3. Install Screws and Washers or Push and Clinch snaps 12
to 72 inches apart from each other on the work surface
mat. Make sure that they pierce and clinch the bottom
side of the mat.
4. Snap both ground cords to the push and clinch snaps
installed to the worksurface mat.
5. Route the black ground cord to the monitor’s green
terminal block labeled MAT.
If this does not happen, examine the wrist cord for
continuity or damage and your wrist band to ensure
that it is securely fit. If you have dry skin, apply an
approved dissipative hand lotion such as Menda
Reztore™ ESD Hand Lotion. When leaving the area,
the user can take the wrist cord along or attach it to
the monitor parking snap. The audible alarm will shut
off when operator wrist cord is removed from unit and or
when the cord is attached to the parking snap.
NOTE: Removing the banana plug from the monitor’s
operator jack will disable the audible alarm.
PARKING SNAP
The audible alarm is designed to alert both the operator and
supervisor. The parking snap feature allows the operator to
disconnect when leaving the work area without sounding the
audible alarm. It also provides a means for wrist cord storage
(red OPERATOR GROUND LED will illuminate). When the
operator touches the parking snap, the audible alarm will
disable for 6 seconds. The user can then disconnect the wrist
cord from the wrist band and attach it to the parking snap for
storage.
WORK SURFACE CHANNEL
The Full Time Continuous Monitor’s circuitry is sufficiently
sensitive to detect extremely low current when used with a
worksurface with a conductive layer.
Distributed by:
All-Spec Industries
5228 US Hwy 421 N www.all-spec.com PH: 800-537-0351

TB-3060 Page 4 of 4 © 2012 DESCO INDUSTRIES, INC.
Employee Owned
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com
Note: The monitor will not detect insulative contamination
on the worksurface. “Insulative contamination can increase
the resistance to ground making the worksurface ineffective.”
(ESD TR12-01 section 3.1 Worksurface monitors). ESD
worksurfaces should be kept clean using an approved ESD
cleaner like Reztore™ Antistatic Surface & Mat Cleaner.
When the monitor is connected to an ESD worksurface,
the amount of current that flows is a function of the total
resistance between the Continuous Monitor and through
the worksurface to ground. When the resistance of the
worksurface is below a pre-set threshold, the monitor will
indicate Pass. Conversely, if the resistance level is high
when compared to the monitor’s reference, the unit will fail
and alarm. This is an integrating resistance measuring circuit,
therefore it is relatively insensitive to externally induced
electromagnetic fields. The resistance threshold is factory
set to 10 megohms. (It can be special ordered to other limits.
Contact manufacturer for specifications).
Specifications
Test range of monitored circuit 500K - 10M ohms†
Worksurface limit* Set to 10 megohms
Power Source 120 VAC
50-60 Hz
Current Drain <15 mA RMS
Wrist strap open circuit voltage 1.2 volts peak to peak @
1-2 MicroAmps
Mat test open circuit voltage 5 to 7.5 volts
Response time to alarm <50 mS
Standby “parking” snap delay 6-8 seconds
Long Term Drift 1/2% per decade
(1st decade is 1 hr)
Temperature 10-40 degrees C
Field Adjustment None required
Size .75"x 3.25" x4.38"
(1.9cm x 8.3cm x 11.1cm)
† This cannot be verified with standard DC test equipment.
The continuous monitor is an impedance sensing device and
the limits are determined by the magnitude and angle of the
impedance.
* Contact Desco Customer Service for special limits.
Maintenance and Calibration
The Full-Time Continuous Monitor is solid state and designed
to be maintenance free. It is calibrated to standards traceable
to NIST. There are no user adjustments that can be made.
Because of the impedance sensing nature of the test circuit,
special equipment is required for calibration.
We recommend that calibration be performed annually,
using the Desco 98220 Single-Wire Monitor Calibration Unit.
This Calibration Unit is a most important product which
allows the customer to perform NIST traceable calibration on
Desco single-wire continuous monitors. It is designed to be
used on the shop floor at the workstation, virtually eliminating
downtime, verifying that the continuous monitor is operating
within tolerances.
Figure 7. Desco 98220 Single-Wire Monitor Calibration
Unit
Limited Warranty
Desco expressly warrants that for a period of one (1) year from the
date of purchase Desco Continuous Monitors will be free of defects in
material (parts) and workmanship (labor). Within the warranty period,
a credit for purchase of replacement Desco Continuous Monitors, or, at
Desco’s option, the Continuous Monitor will be repaired or replaced free
of charge. If product credit is issued, the amount will be calculated by
multiplying the unused portion of the expected one year life times the
original unit purchase price. Call our Customer Service Department at
909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for a Return
Material Authorization (RMA) and proper shipping instructions and
address. Please include a copy of your original packing slip, invoice,
or other proof of date of purchase. Any unit under warranty should be
shipped prepaid to the Desco factory. Warranty replacements will take
approximately two weeks.
If your unit is out of warranty, call our Customer Service Department at
909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for a Return
Material Authorization (RMA) and proper shipping instructions and
address. Desco will quote repair charges necessary to bring your unit up
to factory standards.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express
warranty will not apply to defects or damage due to accidents, neglect,
misuse, alterations, operator error, or failure to properly maintain, clean
or repair products.
Limit of Liability
In no event will Desco or any seller be responsible or liable for any injury,
loss or damage, direct or consequential, arising out of the use of or
the inability to use the product. Before using, users shall determine the
suitability of the product for their intended use, and users assume all risk
and liability whatsoever in connection therewith.
Distributed by:
All-Spec Industries
5228 US Hwy 421 N www.all-spec.com PH: 800-537-0351
Table of contents
Other Desco Monitor manuals

Desco
Desco 19246 Instruction Manual

Desco
Desco 19325 Installation and operating instructions

Desco
Desco 19668 Installation and operating instructions

Desco
Desco 19239 Installation and operating instructions

Desco
Desco 19234 Service manual

Desco
Desco 19665 Installation and operating instructions

Desco
Desco 19226 Service manual

Desco
Desco 19208 Service manual

Desco
Desco EMIT 50513 Installation guide

Desco
Desco TB-3086 Service manual