*** Illumination differential report ***
This function default is disabled, to enable this function b setting the
configuration NO.22 not to zero.
Enable this functionalit , the device will measure the illumination in
ever one minute. And if the illumination is changed to plus or minus
the value (setting b the configuration NO.22), the device will report
illumination information to the nodes in the group 1.
Caution 1:
Enable this function will reduce the batter life about 15%
~ 20%. And another issue is setting the differential value too small, it
will cause report too frequenc , shorter the batter life more.
Propose the setting differential value should not small than 10.
Caution 2:
If the configuration No.4 is setting to 0 or 100, this
functionalit is useless.
Caution 3:
Enable this functionalit , it will cause the Motion Detector
to disable detection when the illumination measurement. In other
words, The Motion Detector will blind one second in ever one minute.
* Timing eport:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
•Batter level report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 10.
•Low batter report: When the batter level is too low, ever 30
minutes will report once.
•Door/window state report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 11.
•Illumination level report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 12.
•Temperature report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 13.
Notice: The configuration NO. 10, 11, 12 and 13 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
report except the low batter detection.
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
batter immediatel . If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new batter .
* Motion Detector Warm Up
When the device power on, the Motion Detector need to warm up
before the operation. The warm up time about 1 minute, the LED will
flash in ever 2 seconds. After finish the procedure the LED will light
ON three times.
* NWI
When the device power on, the device will check is it alread adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in ever second and continue 30 seconds. Until timeout or the
device successful to inclusion b controller. The use can presses the
tamper ke 3 times to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normall
the device is alwa s sleeping to save the batter energ .
Over The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Before starting the procedure, please remove the front cover of the
device. Otherwise the hardware check will be failed.
Let the controller into the firmware update mode, and then press the
4