DHR 320RC Series User manual

Navigation Lights
Signalling Lights
Searchlights
Whistles
TECHNICAL MANUAL
DHR 320RC-SERIES
Remote Controlled Searchlight
Den Haan Rotterdam
S
i
n
c
e
1
9
2
2

2Version 0.95 June 2023
Den Haan Rotterdam
(Intentionally blank page)

3Version 0.95 June 2023
Den Haan Rotterdam
DAMAGE DUE TO INAPPROPRIATE HANDLING IS
NOT COVERED BY THE WARRANTY.
© Copyright, Den Haan Rotterdam B.V.
Version 0.95 June 2023
This document contains proprietary information that is protected by copyright.
All rights reserved.
!SAFETY NOTES
• Turn power off before inspection, installation or removal
• Don’t stare directly into the LEDs, Always use eye protection when handling LEDs
• This product can be damaged by electrostatic discharge, ESD. When handling take close care
before opening the drum to avoid damaging the LEDs.
• Allow lamp/xture to cool before handling
• Do not use the searchlight if outer glass is scratched or broken

4Version 0.95 June 2023
Den Haan Rotterdam
Den Haan Rotterdam is a family-owned company established in 1922. Started as a small tinsmith, it has evolved
into a globally respected producer of navigation lights, searchlights, air horns and a wide range of nautical
lamps made from copper and brass. By introducing products with advanced LED-technology, DHR has safe-
guarded a visibly safe future for marine vessels in all weather conditions.
Den Haan Rotterdam manufactures halogen searchlights for over 30 years and are known for their robustness,
quality and reliability: key values for marine equipment. The RC-series is the second generation of DHR remote
controlled type of searchlights introduced in 2019. This product range is very popular, because of its compact
size and its simplicity in installation and operation. The RC-series includes two types of light sources, such as:
halogen bulbs and LEDs. Also the optical performance is top-notch, thanks to the use of silver plated mirror
reectors.
The application of the 230-, 320- and 420-series searchlights is limitless. Mostly they are benicial for work
boats, tugs, shing vessels, dredgers and even watch towers for land based solutions.
DEN HAAN ROTTERDAM B.V.
D.M. Den Haan
Managing Director
QUALITY STANDARDS
Excellent Optics
Maintenance Friendly
Adjustable Focus
Light Weight Construction
IP66 Water Ingress Protection
Remote control
PREFACE
LED Technology

5Version 0.95 June 2023
Den Haan Rotterdam
TABLE OF CONTENTS
Safety notes 3
Preface 4
Quality standards 4
1. Mounting instructions 6
2. Specications 8
3. Dimensions 10
4. Photos 12
5. Wiring diagrams 14
6. Safety, maintenance and correct use 16

6Version 0.95 June 2023
Den Haan Rotterdam
1. MOUNTING INSTRUCTIONS
MOUNTING THE PANEL
Place the control panel inside the wheelhouse, where it is protected against weather inuences. The housing is
especially constructed to be ush mounted in an instrument cabinet according the illustration on the right.
The minimum required depth for the panel inside the console is 50 mm [4.33 inch].
SEARCHLIGHT INSTALLATION
Install the searchlight in a horizontal upright position with sucient space around the head of the searchlight to
ensure it can move freely. The dimensions can be found on page 9.
FASTENERS
• The permissible torque should be 8 Nm
• Use only A4-grade stainless steel
CAUTION!
Even though the housing is made of corrosion resistant materials, galvanic corrosion may still occur. To
prevent galvanic corrosion use the supplied insulation sleeves to isolate the aluminium housing from other
metal parts.
Den Haan Rotterdam does not accept responsibility for any damage if the searchlight is installed
incorrectly and/or used improperly. When in doubt consult a qualied electrical technician.
!
Bolt M10x (60 + M)
Insulation sleeve
Lantern base
Insulation sleeve
Washer M10
Mounting plate Min. 5 mm [0.20 inch]
Nut M10
4 x Ø10 [0.39]
162,5 [6.40]
162,5 [6.40]
All sizes are in mm [inch]
4,2
0,17
90
3,54
127
5
92
3,62
125
4,92
8
0,31
/ 45°
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:1
SHEET 2 OF 7
A3
Johan Jurgens
Paneel 2019 NF
B
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
Searchlight panel PAN2019NF
18-11-2019
NAME
NAV Part:
PAN2019NF
GOEDGEKEURD
A A
B B
C C
D D
E E
F F
G G
H H
6
6
5
5
4
4
3
3
2
2
1
1
WARNING!

7Version 0.95 June 2023
Den Haan Rotterdam
ELECTRICAL INSTALLATION
Install the electrical wiring according to the wiring diagrams showed on pages 11 - 14. Keep the distance between
the power supply and halogen lamp as short as possible. Long wires will increase a voltage drop near the halogen
lamp, which affects the light output.
CABLE GLANDS
ØD
CABLE
• Preferred diameter D is 7 - 12 mm
• Material: Neoprene H07RN-F
Cable too tight!
This gives unwanted stress at the sealing of the
cable gland and water ingress will occur.
Include cable slack at the entering
point of the cable gland
REPLACING CABLE GLAND
• Use gasket between housing
and cable gland
• Tighten rmly (6Nm) with
wrench
Remove the plug before placing the cable.
If no cable is connected, leave the plug in place!
NOTE
The cable glands on the searchlight prevent water ingress. Do not use (electrical) tape to cover the cable
where it enters the cable gland as this will cause water ingress. Do not use a rubber or shrinkable cover
on the cable gland to improve water tightness.

8Version 0.95 June 2023
Den Haan Rotterdam
2. SPECIFICATIONS
CONTROL PANEL
Model PAN2019F
Dimensions
Depth 105 mm
Width 140 mm
Weight 0,25 kg
Electrical
Voltage 24 VDC
Maximum wattage 5 W
Fuse ( 2x) Resettable fuse
Electrical insulation class III
Housing
Front Aluminium / Acrylic black - IP65
Back Acrylic blue
Operating temperature 0 - 40 °C [32 - 104 °F]

9Version 0.95 June 2023
Den Haan Rotterdam
Searchlight
Model 320RCL22 320RCP22
Dimensions
Height 820 mm
Width 377 mm
Weight 16,6 Kg
Electrical
Mains voltage 115/230VAC
Maximum wattage 150W 250W
Preferred cable type H07RN-F
Cable diameter Ø 6-12 mm
Optics
Parabolic mirror reector Ø 320 mm
Range at 1 lux 1200 m 1700 m
Adjustable Focus Yes (4-20°)
Minimum beam angle at 50% 4° x 4° 4°x 5°
Luminous intensity 1.500.000 cd 3.000.000 cd
LED
Model COB-LED LED-matrix
Luminous ux 13.000 lm 18.000 lm
Wattage 80 - 90 W 170 W
Average life-time 10.000 h
Color temperature 6500 K 5700 K
Heater
Type PTC
Voltage 100-240V
Maximum wattage 50 Watt
Motor Unit
Tilt + 25° / - 40°
PAN 340°
Max. speed left / right approx. 34°/ sec
Max. speed up / down approx. 3,2° / sec
Housing
Material Chromated seawater resistant aluminium
Finish UV resistant powder coating - White RAL9016
Front glass Hardened glass
Seals Silicone / Neoprene, black
Cable gland M25x1.5
Operating temperature - 25° / + 40° C
Ingress protection class Head IP66 c/w Membrane vent

10 Version 0.95 June 2023
Den Haan Rotterdam
3. DIMENSIONS
CONTROL PANEL
All sizes are in mm [inch]
Max. 100 metre
320RC-SERIES
PAN2019F
1
2
3
4
5
In combination with joystick controls the beam width
To select two speed settings: slow / fast
Switching the light source on/off
To control the direction of movement
To adjust the light intensity of the illuminated buttons
51
2,02
49
1,92
140
5,51
105
4,13
SWITCHES
1. FOCUS
2. SPEED
3. BEAM
5. JOYSTICK
POTENTIOMETER
4. DIM
115/230VAC
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:10
SHEET 3 OF 3
A3
Johan Jurgens
A00DOC-ZL0014 Doc
-
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
SEARCHLIGHT 320 RC LED -
115/230VAC 100W
20-06-2023
NAME
NAV Part:
320RCL22
1.500.000 CD / 1200 METRE
A A
B B
C C
D D
E E
F F
G G
H H
6
6
5
5
4
4
3
3
2
2
1
1
Max. 100 metre
320RC-SERIES
PAN2019F
1
2
3
4
5
In combination with joystick controls the beam width
To select two speed settings: slow / fast
Switching the light source on/off
To control the direction of movement
To adjust the light intensity of the illuminated buttons
51
2,02
49
1,92
140
5,51
105
4,13
SWITCHES
1. FOCUS
2. SPEED
3. BEAM
5. JOYSTICK
POTENTIOMETER
4. DIM
115/230VAC
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:10
SHEET 3 OF 3
A3
Johan Jurgens
A00DOC-ZL0014 Doc
-
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
SEARCHLIGHT 320 RC LED -
115/230VAC 100W
20-06-2023
NAME
NAV Part:
320RCL22
1.500.000 CD / 1200 METRE
A A
B B
C C
D D
E E
F F
G G
H H
6
6
5
5
4
4
3
3
2
2
1
1

11 Version 0.95 June 2023
Den Haan Rotterdam
SEARCHLIGHTS
All sizes are in mm [inch]
460
18,11
Min. turing circle
625
24,62
822
32,35
629
24,76
376
14,81
162,5
6,4
4 x
10
0,394
Fasteners
• The permissible torque should be 8 Nm
• Use only A4-grade stainless steel
DRILL HOLES
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:5
SHEET 2 OF 3
A3
Johan Jurgens
A00DOC-ZL0014 Doc
-
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
SEARCHLIGHT 320 RC LED -
115/230VAC 100W
20-06-2023
NAME
NAV Part:
320RCL22
1.500.000 CD / 1200 METRE
A A
B B
C C
D D
E E
F F
G G
H H
6
6
5
5
4
4
3
3
2
2
1
1

12 Version 0.95 June 2023
Den Haan Rotterdam
4. PHOTOS

13 Version 0.95 June 2023
Den Haan Rotterdam

14 Version 0.95 June 2023
Den Haan Rotterdam
5. WIRING DIAGRAMS
CONTROL PANEL
Max. 100 metre
320RC-SERIES
PAN2019F
1
2
3
4
5
In combination with joystick controls the beam width
To select two speed settings: slow / fast
Switching the light source on/off
To control the direction of movement
To adjust the light intensity of the illuminated buttons
51
2,02
49
1,92
140
5,51
105
4,13
SWITCHES
1. FOCUS
2. SPEED
3. BEAM
5. JOYSTICK
POTENTIOMETER
4. DIM
115/230VAC
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:10
SHEET 3 OF 3
A3
Johan Jurgens
A00DOC-ZL0014 Doc
-
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
SEARCHLIGHT 320 RC LED -
115/230VAC 100W
20-06-2023
NAME
NAV Part:
320RCL22
1.500.000 CD / 1200 METRE
A A
B B
C C
D D
E E
F F
G G
H H
6
6
5
5
4
4
3
3
2
2
1
1

15 Version 0.95 June 2023
Den Haan Rotterdam
DUAL PANEL

16 Version 0.95 June 2023
Den Haan Rotterdam
6. SAFETY, MAINTENANCE AND CORRECT USE
ESD
This product, like all LED searchlights, uses semi-conductors that can be damaged by elec-
trostatic discharge (ESD). When handling, take close care before opening the drum to avoid
damaging the LEDs.
THE FOLLOWING PRECAUTIONS MUST BE TAKEN:
• Always disconnect the power from the light before any maintenance.
• Use a conductive wrist strap attached to a good earth ground.
• Always discharge yourself by touching grounded bare metal.
• Use an approved anti-static mat to cover your work surface.
• When in doubt always consult a qualied electrician.
DON’T STARE DIRECTLY INTO THE LEDS.
All cool white LEDs (5000 Kelvin and higher) contain a lot of blue and can be harmful to our eyes. Always use eye
protection when handling LEDs
TIPS FOR CORRECT USE
• Switch off the searchlight immediately after use, this increases the life expectancy of the COB - LED
• Do not light-up objects closer than 2 metres
• Do not point the light beam at the eyes of humans or animals
PREVENTIVE MAINTENANCE
Clean the searchlight with fresh water regularly. Do not use any aggressive cleaning agents. At least twice a year
rub the V-ring and dirt wiper in with silicone grease.
Dirt wiper
V-ring
Tips for correct use
• Switch off the searchlight immediately after use, this increases the life expectancy of the COB - LED
• Do not light-up objects closer than 2 metres
• Clean the searchlight regularly with water
• Do not point the light beam at the eyes of humans or animals
Preventive maintenance
Clean the searchlight with clean water regularly. Do not use any aggressive cleaning agents. At least twice a year rub the V-ring and dirt
wiper in with silicone grease.
DRAWN
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS [INCHES]
FINISH:
DATE
DO NOT SCALE DRAWING
REVISION:
TITLE:
FILE NAME:
SCALE:1:8
SHEET 4 OF 5
A3
Johan Jurgens
230CCL21-standard
-
DEN HAAN ROTTERDAM BV
Fascinatio Boulevard 1182
2909VA Capelle a/d IJssel
Alum. LED searchlight 230CC -
115/230VAC
03-09-2020
NAME
NAV Part:
-
A A
B B
C C
D D
E E
F F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1

S
I
N
C
E
1
9
2
2
ADVANCED MARITIME
SIGNALLING SOLUTIONS
Den Haan Rotterdam
Fascinatio Boulevard 1182
2909 VA Capelle a/d ssel
The Netherlands
T +31 (0) 10 413 07 55
Esales@dhr.nl
www.dhr.nl
This manual suits for next models
2
Table of contents
Other DHR Controllers manuals