Diamond®SeroFlow™Plus
Pipette Controller
Quick Start Guide
Continued . . .
Nose Cone
Operating
Triggers
LED Display
Coarse Speed
Adjustment
Button
Battery Compartment Cover
Name Function
Operating Triggers Analog triggers used to aspirate and dispense liquid. The rate of aspiration can be controlled by the
extent of force applied to each trigger.
LED Display The display shows both the battery charge state and the coarse speed setting.
Coarse Speed Adjustment
Button (- / +)
The overall rate of aspiration and dispensing can be adjusted using these buttons.
Nose Cone & Silicone Adaptor The visible outer nose cone and interior silicone pipette adaptor that accept the serological pipettes.
0. 45µm Filter Inline lter placed just above the nose cone, located internally between the pipette controller
components and silicone adaptor
Battery Compartment Cover Access cover for removing and replacing the rechargeable battery. Remove by pressing on the
textured area and sliding towards the rear of the unit. Replace by reversing this motion.
What’s in the box:
• Quick Start Guide
• Diamond SeroFlow Plus
Pipette Controller
• 0.45µm lters (2ea)
• Power Adaptor
0. 45µm lter
Silicone
Adaptor
Customer Service, Sales and Technical Support:
Phone: 1 (800) 394-4562 • 1 (201) 599-1400
Fax: 1 (201) 599-1406 • E-mail: mail@globescientic.com
© 2022 Globe Scientic Inc. All rights reserved. The Globe Scientic logo is a registered trademark of Globe Scientic Inc. 3387 Guide 22214
®
Diamond®SeroFlow™Plus
Pipette Controller
Quick Start Guide
OPERATING INSTRUCTIONS
IMPORTANT: The pipette controller cannot be operated
without the internal lter in place. During operation, please do
not overll the serological pipette beyond its maximum level
as this may contaminate the pipette controller and the internal
lter. If overlling occurs, change the internal lter immediately
and clean any potentially contaminated components, including
the silicone adaptor. Only use lters provided by Globe
Scientic.
Charging the Unit
• Use only the power adaptor supplied with the unit. Using a
different adaptor may cause damage to the unit or even create
a re or explosion hazard.
• The pipette controller can be charged by plugging the power
adaptor directly into the unit.
• The unit may be used while charging.
Speed Adjustment
• Overall (coarse) aspiration and dispensing speed can be
controlled by adjusting the speed adjustment button. Press
the minus (-) side to slow the rate, and press the plus (+) side to
increase the rate.
• Fine speed control can be achieved by using varying pressure
on the operating triggers.
Fit the Pipette
• Gently insert a serological pipette into the silicone adaptor
located in the nose cone. Do not use excessive force as this may
damage the silicone insert.
Aspiration / Dispensing
• Aspirate or dispense using the appropriate triggers. The desired
rate can be controlled using both the speed adjustment button
and varying pressure on the triggers (see: Speed Adjustment).
In addition to using the dispense trigger, ne control dispensing
can be performed by using the effect of gravity.
PRECAUTIONS
• Never use the pipette controller with highly ammable liquids.
• Carefully read and understand these instructions prior to use.
• Ensure a good working environment free of explosive or
hazardous and inammable substances.
• Do not use excessive force when using.
• If the pipette controller does not operate normally, immediately
stop operation.
• Only use spare parts provided by Globe Scientic.
• Preferable operation and storage temperature range is +10°C
to +30°C.
Service: In the unlikely event service is required, please contact
Globe Scientic.

Other Diamond Controllers manuals

Diamond RED07/35 User manual

Diamond

Diamond RED07/35 User manual

Diamond AN403T-3L Manual

Diamond

Diamond AN403T-3L Manual

Popular Controllers manuals by other brands

Mikroe DMX Click user manual

Mikroe

Mikroe DMX Click user manual

SENSIRION SFC6 Series manual

SENSIRION

SENSIRION SFC6 Series manual

Emerson Fisher EZR Relief installation guide

Emerson

Emerson Fisher EZR Relief installation guide

Honeywell SP907B installation instructions

Honeywell

Honeywell SP907B installation instructions

QUANT QUANT-18 Operation manual

QUANT

QUANT QUANT-18 Operation manual

Lynch Electronics LE PB X Setting instructions

Lynch Electronics

Lynch Electronics LE PB X Setting instructions

Marley LLC+u user manual

Marley

Marley LLC+u user manual

Zennio FANinBOX 230V 1CH Technical documentation

Zennio

Zennio FANinBOX 230V 1CH Technical documentation

Johnson Controls VA9104-AGA-1S installation instructions

Johnson Controls

Johnson Controls VA9104-AGA-1S installation instructions

LOVATO ELECTRIC ADX Series Wiring diagrams

LOVATO ELECTRIC

LOVATO ELECTRIC ADX Series Wiring diagrams

MSA Zero Two Series manual

MSA

MSA Zero Two Series manual

Mitsubishi Electric MELSEC Q Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC Q Series user manual

Vive Comfort TP-S-905 Operation manual

Vive Comfort

Vive Comfort TP-S-905 Operation manual

KwikFire Elite 2 Series instruction manual

KwikFire

KwikFire Elite 2 Series instruction manual

CLA-VAL VC-22D quick start

CLA-VAL

CLA-VAL VC-22D quick start

Emerson PNC001-A Series Important product information

Emerson

Emerson PNC001-A Series Important product information

Naked NKD-pH Installation & start?up guide

Naked

Naked NKD-pH Installation & start?up guide

SolaStat SolaStat-Pool installation guide

SolaStat

SolaStat SolaStat-Pool installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.