Diamond®SeroFlow™Plus
Pipette Controller
Quick Start Guide
Continued . . .
Nose Cone
Operating
Triggers
LED Display
Coarse Speed
Adjustment
Button
Battery Compartment Cover
Name Function
Operating Triggers Analog triggers used to aspirate and dispense liquid. The rate of aspiration can be controlled by the
extent of force applied to each trigger.
LED Display The display shows both the battery charge state and the coarse speed setting.
Coarse Speed Adjustment
Button (- / +)
The overall rate of aspiration and dispensing can be adjusted using these buttons.
Nose Cone & Silicone Adaptor The visible outer nose cone and interior silicone pipette adaptor that accept the serological pipettes.
0. 45µm Filter Inline lter placed just above the nose cone, located internally between the pipette controller
components and silicone adaptor
Battery Compartment Cover Access cover for removing and replacing the rechargeable battery. Remove by pressing on the
textured area and sliding towards the rear of the unit. Replace by reversing this motion.
What’s in the box:
• Quick Start Guide
• Diamond SeroFlow Plus
Pipette Controller
• 0.45µm lters (2ea)
• Power Adaptor
0. 45µm lter
Silicone
Adaptor
Customer Service, Sales and Technical Support:
Phone: 1 (800) 394-4562 • 1 (201) 599-1400
Fax: 1 (201) 599-1406 • E-mail: mail@globescientic.com
© 2022 Globe Scientic Inc. All rights reserved. The Globe Scientic logo is a registered trademark of Globe Scientic Inc. 3387 Guide 22214
®
Diamond®SeroFlow™Plus
Pipette Controller
Quick Start Guide
OPERATING INSTRUCTIONS
IMPORTANT: The pipette controller cannot be operated
without the internal lter in place. During operation, please do
not overll the serological pipette beyond its maximum level
as this may contaminate the pipette controller and the internal
lter. If overlling occurs, change the internal lter immediately
and clean any potentially contaminated components, including
the silicone adaptor. Only use lters provided by Globe
Scientic.
Charging the Unit
• Use only the power adaptor supplied with the unit. Using a
different adaptor may cause damage to the unit or even create
a re or explosion hazard.
• The pipette controller can be charged by plugging the power
adaptor directly into the unit.
• The unit may be used while charging.
Speed Adjustment
• Overall (coarse) aspiration and dispensing speed can be
controlled by adjusting the speed adjustment button. Press
the minus (-) side to slow the rate, and press the plus (+) side to
increase the rate.
• Fine speed control can be achieved by using varying pressure
on the operating triggers.
Fit the Pipette
• Gently insert a serological pipette into the silicone adaptor
located in the nose cone. Do not use excessive force as this may
damage the silicone insert.
Aspiration / Dispensing
• Aspirate or dispense using the appropriate triggers. The desired
rate can be controlled using both the speed adjustment button
and varying pressure on the triggers (see: Speed Adjustment).
In addition to using the dispense trigger, ne control dispensing
can be performed by using the effect of gravity.
PRECAUTIONS
• Never use the pipette controller with highly ammable liquids.
• Carefully read and understand these instructions prior to use.
• Ensure a good working environment free of explosive or
hazardous and inammable substances.
• Do not use excessive force when using.
• If the pipette controller does not operate normally, immediately
stop operation.
• Only use spare parts provided by Globe Scientic.
• Preferable operation and storage temperature range is +10°C
to +30°C.
Service: In the unlikely event service is required, please contact
Globe Scientic.

Other Diamond Controllers manuals

Diamond AN403T-3L Manual

Diamond

Diamond AN403T-3L Manual

Diamond RED07/35 User manual

Diamond

Diamond RED07/35 User manual

Popular Controllers manuals by other brands

CHROMATEQ TOUCH 512 DATASHEET AND QUICK START GUIDE

CHROMATEQ

CHROMATEQ TOUCH 512 DATASHEET AND QUICK START GUIDE

Evco EVJ254 manual

Evco

Evco EVJ254 manual

National Instruments FELDPoint FP-2000 quick start guide

National Instruments

National Instruments FELDPoint FP-2000 quick start guide

Speidel Garmeister CONTROL 2.0 operating manual

Speidel

Speidel Garmeister CONTROL 2.0 operating manual

Hy-Gain RC1-H instruction manual

Hy-Gain

Hy-Gain RC1-H instruction manual

Johnson Controls FMS-1655L installation manual

Johnson Controls

Johnson Controls FMS-1655L installation manual

ABB i-bus SA/S 12.16.6.1 product manual

ABB

ABB i-bus SA/S 12.16.6.1 product manual

PYROTEC D1 operating instructions

PYROTEC

PYROTEC D1 operating instructions

Ametek Magnetrol Tuffy Installation and operating manual

Ametek

Ametek Magnetrol Tuffy Installation and operating manual

Pilz PSEN sl-1.0p 3.1 operating manual

Pilz

Pilz PSEN sl-1.0p 3.1 operating manual

WEG AVR-A-OPT-16 Installation, operation and maintenance manual

WEG

WEG AVR-A-OPT-16 Installation, operation and maintenance manual

D+H Dyer CDP-TW-K-BSY+ Series instructions

D+H

D+H Dyer CDP-TW-K-BSY+ Series instructions

Duratrax IntelliSpeed 12T operating instructions

Duratrax

Duratrax IntelliSpeed 12T operating instructions

Kohler 6EKOD installation instructions

Kohler

Kohler 6EKOD installation instructions

Humboldt HM-5250.3F product manual

Humboldt

Humboldt HM-5250.3F product manual

NT KN303 user manual

NT

NT KN303 user manual

Baelz Automatic BA 375-E42 operating instructions

Baelz Automatic

Baelz Automatic BA 375-E42 operating instructions

MULTIQUIP ECU800 Series technical information

MULTIQUIP

MULTIQUIP ECU800 Series technical information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.