digi-tech XC4134 User manual

1
SerialToEthernetConverter
XC4134
UserManual

2
TableofContents
Introduction .... 4
Overview..5
PackageChecklist6
BlockDiagram7
Product Features...8
Product Specifications 9
ConverterDescription&Installation 11
Product Panel Views...11
Left Side.12
Right Side..13
LEDIndicators..14
WiringArchitecture15
RS-232......................... 15
RS-422/RS-485..16
ConverterConfiguration ..17
InitialIPConfiguration ...17
Device ManagementUtilityof ETM .18
Menu “View”.19

3
Menu “Config”19
WebConsoleConfiguration19
ControllerStatus 22
ControllerSetup.24
ControllerUpdated 30
FactoryDefaultSetting.31
Self-Testing ..32
HyperTerminalforTCP/IPWinSock 33
HyperTerminalforCOMPort.36
DataTransmission.36
AppendixA-FAQ 37
AppendixB-PinOutsand CableWiring ..38
DCPowerOutlet.38
RJ-45 PinAssignment..38
RS-232PinAssignment...38
RS-422PinAssignment...39
RS-485PinAssignment...39

4
Introduction
Weareprovidesnewwaysof connectingserialdevicestoLocalAreaNetwork
(LAN)orWide Area Network(WAN). XC4134 TCP/IPconverterisdesignedto
operateserialportsover10/100MEthernetnetworks.Thedatatransmittedvia
TCP/IPprotocol.Therefore,controlisavailableviaEthernet, Intranetand
Internet. XC4134TCP/IPconverterpackagedinplasticcasewellsuitesfor
industrialenvironments.Allserialportsoperateincommon RS-232mode,
industrialRS-422andRS-485modesconfiguration.
XC4134TCP/IPconverterseriesislow-costandhighperformancedesign.By
carefulselectinghighqualitywithcompetitivepricescomponentsinthe world,
XC4134makesnetworkconnectivitypossiblewithaffordablecostforvirtually
all kindsofserialdevices.
The followingtopics arecovered inthischapter:
Overview
Package Checklist
BlockDiagram
ProductFeatures
ProductSpecifications

5
Overview
XC4134TCP/IPconverterisdesignedtomakeyourserialdevicesInternet
readyinstantly.8051SeriesofXC4134 TCP/IPconvertermakesidealchoice
forconnectingyourRS-232orRS-422/485serialdevices—suchasPLCs,
metersandsensors—toIP-basedEthernetLAN makingpossibleforyour
softwaretoaccess serialdevicesanywhereand anytimeoverlocalLANor
Internet.
8051Seriesconvertersensurethecompatibilityofnetworksoftwarethatuses
standardnetworkAPI(Winsock orBSD Sockets)byproviding TCPServer
Mode,TCPClientModeand UDPMode.8051Series’VirtualCOMdriver,
softwarethatworkswithCOM port can setup toworkoverTCP/IPnetworkin
no time. Thisexcellentfeaturepreservesyoursoftwareinvestmentandlet you
enjoythebenefitsofnetworkingyourserialdevicesinstantly.
8051Seriesconverterssupport manualconfigurationviathe handyweb
browserconsoleandmanyprotocolsincluding TCP,IP,UDP,HTTP,DHCP,
ICMPand ARP. Theyarethebest solution tonetworkyour serialdevices.

6
PackageChecklist
8051productsareshippedwiththe followingitems:
□
□
□1unit ofXC4134 TCP/IPconverter
□
□
□1unit ofPowerAdaptor ( Input:100-240VAC500mA)
(Output:12VDC 1000mA)
□
□
□Documentation &SoftwareCD
NOTE:Pleasenotifyyoursalesrepresentativeif anyoftheaboveitemsare
missingordamaged.

7
BlockDiagram
Low-costdevicesareusuallyequipped withlowspeedprocessorsandlimited
memories.Inreality,neitherhaving thecapabilitynorpracticalitytomanage
complicated the TCP/IPnetworkprotocols.8051Seriesislowcostwhile
providing highperformancenetworksolution byconverting datastream
betweennetworkTCP/IPandpopular serialport signals.Insteadofprocessing
TCP/IPpacketsdirectly,devicesneedonlydealwiththoseinterfacesignal
whichgreatlysimplifiesthe complexityof TCP/IPnetworkinlinkage.
Product Features
□
□
□DataConversionbetweenRS-232/422/485 andEthernet
Convert serialdevice(RS-232,RS-422,RS-485)data/signalintoTCP/IP
packetdata/signalandsendoutwithEthernetdatastreamorconvert the
TCP/IPpacketdata/signalintoserialdevicedata/signal.

8
□
□
□DynamicIPConfiguration
Support DHCP clientmode,simplifyingnetworkaddressconfigurationand
management.
□
□
□DualLANSpeed
Support 10/100MbpsEthernet, auto-detected.
□
□
□Server/ ClientDual Modes
8051Seriescanbe configuredasnetworkserverornetworkclient.Intheclient
modecanbeinstallednetworkwhichprotectedbyNATrouterorfirewall,
withoutneedarealIPaddress.
□
□
□Web-basedSetup
ParameterssetupbasedonHTTPprotocolbyusing standardbrowsers(IEand
Netscape). Nospecialsoftwarewouldberequired.
□
□
□Built-inSecurityControl
Protectedsetupthe passwordtopreventintruders.
□
□
□
FirmwareRemoteUpdate
Firmwarecan beupdated directlyviaEthernetnetworktokeep upwithlatest
networkstandards.
Product Specifications
lCPU:8-bits8051,36.864MHz
lRAM :32KBytesSRAM
lROM:64KBytes

9
lEthernet
Port Type: RJ-45Connector
Speed: 10 /100 Mbps(AutoDetecting)
Protocol: ARP, IP, ICMP,UDP, TCP,HTTP, DHCP
Mode: TCPServer,TCPClient , UDP
Setup:HTTPBrowserSetup (IE&Netscape)RS-232 Console
Security: SetupPassword
Protection:Built-in1.5KVMagneticIsolation
lSerialPort
No.ofPorts:RS-232/ RS-422/ RS-485x1Port
Port Type: DB9male
Speed: 300bps 115.2Kbps
Parity: None ,Odd ,Even
DataBit: 7, 8
Stop Bit: 1, 2
RS-232Signals:Rx, Tx,GND,RTS, CTS, DTR,DSR,DCD
RS-422Signals:Rx+,Rx- , Tx+,Tx- (SurgeProtection)
RS-485Signals:Data+, Data-(SurgeProtection)
Built-inRS422/RS485TerminalResistor
l15KVESDforallsignals
lWatchDogFunction
lFirmwareOn-lineUpdated ViaEthernet

10
lPower:Input:DC 9 –12V
lLEDLamp:PWR(Green)
lDATA(Red-Blinkduringdatatransferring and receiving)
lLAN(Red)
lSYS(Red-Blink)
lEnvironment:OperatingTemperature: 0 60
StorageTemperature:-10 70
lDimensions:85 x75x25mm(WxDxH)
lWEIGHT:110gm
lRoHS:CompliantwithRoHS
lRegulatoryApprovals: EMC:FCCClass A,CEClass A
lWARRANTY: 1year

11
ConverterDescription
ProductPanelViews
LAN
DC-In
Power Outlet
SerialPort
RS-485/RS-422
SerialPort
RS-232
ResetButton
Terminator
LEDIndicators

12
LeftSide
Power Supply
The XC4134 TCP/IPconverterpowered bysingle9~12VDC(Inner
positive/outernegative)powersupplyand500mAofcurrent. Asuitable
powersupplyadapterisinpart of the package.Connect powerline topower
outletatrightsideofXC4134 TCP/IPconverterand putadapterintosocket.
If thepowerproperlyissupplied, the “PWR”green colorLEDwillblinkeach
time inonesecond.
LAN Port
The connectorfornetworkisusualRJ45.Simplyconnecttoyournetwork
switchorHub.When made the connection,the LANLEDindicatorwill light.
When datatrafficoccursonthenetwork,red DATALEDindicatorwillblink
during transferring andreceivingdata.
Resent Button
Press buttontoturnon thepowerandwaitingfor3seconds.Converterwill
reset tofactorydefault.
DC-In
PowerOutlet
LAN
ResetButton

13
RightSide
SerialI/OPortofRS-232/RS-422/RS-485
Connectthe serialdatacablebetweenconverterand serialdevice.Please
followtheparametersetupprocedurestoconfigure theconverter(see the
following chapters).
Terminator
Thereisterminatorresistorbuilt in.Ifswitch1&2areset in “ON”position,
120Ohmresistorconnectedbetweenthe signals.
SerialPort
RS
-
232
Serial
Port
RS
-
4
85/RS
-
422
Terminator

14
LEDIndicators
SYS “RedLED”:Powerindicator
(When poweron,LEDwillflasheachtimeinonesecond.)
LAN “GreenLED”:On-lineindicated
(When converterislinktoLANthenLEDwillkeep on.)
100M- GreenLED、10M-RedLED
DATA “RedLED”: Datasending&receiving indicator
(When sending andreceivingdatatonetwork,LEDwill
blink.)
PWR “GreenLED”: Powerindicator
(When poweron,LEDwillflashallthe time.)

15
WiringArchitecture
RS-232WiringArchitecture
RS-232 Wiring
Serial Device Converter
RS-232 (RTS / CTS)Wiring
Serial Device Converter
RS-232 (RTS / CTS, DSR/DTR) Wiring
Serial Device Converter
HUB
RX
TX
GND
TX
TX
GND
RX
TX
GND
RTS
CTS
TX
RX
GND
CTS
RTS
HUB
RX
TX
GND
RTS
CTS
DTR
DSR
TX
RX
GND
CTS
RTS
DSR
DTR
HUB

16
RS-422/RS-485WiringArchitecture
RS-422Wiring
Serial Device Converter
RS-485Wiring
Serial Device Converter
When you finishthe stepsmentioned aboveand LEDindicatorsasshown,
installedconvertercorrectly.You can useSetup Tool “ETM.exe”tosetupthe
IPAddress.
Forproceed setupadvancedparameters,pleaseusewebbrowser(IEor
Netscape)tocontinuesettingthedetails.
T+
T-
R+
R-
R+
R-
T+
T- HUB
D+
D- D+
D- HUB

17
ConverterConfiguration
InitialIP Configuration
When firstsettingup yourconverter,thefirstthingyou shoulddoisto
configuretheIPaddress.Thischapterintroducesthemethodtoconfigure
the deviceserver’sIPaddress.Formoredetailsaboutsettingsnetwork,
pleasesee “Web ConsoleConfiguration”(Inthenext sub section).
Forquicklyand easiertostart, wesuggest youtoreferto “Quick Installation Guide”
manual.
The followingtopics arecovered inthischapter:
□
□
□
DeviceManagementUtility
□
□
□
Menu “View”
□
□
□
Menu “Config”

18
DeviceManagementUtilityofETM
OnPCweprovide DeviceManagementUtilitynamed ETM.exewhichis
executableprograminWindows32bitenvironments.ETMSetupToolis
usedtodetectandsetuptheinstalled converters.It usesUDPbroadcast
packetstoqueryandconfigureconverterson thenetwork.
When youactivatetool,itwilldetectexistenceofinstalledconvertersand
depicttheconverters’statussuchasIPaddress,SubnetMask,MAC
Address andDeviceID(see Figure3.1).
IfyourcomputerOSisWindowsXP version whichmeans “WINDOWS
Firewall”function inOSactivated.However,ETM.exewouldn’tdetectthe
converterIPaddress,youhavetotemperatelydisable “WINDOWSFirewall”
function.Afterfinishingsettingtheparameters,youcanrestart “WINDOWS
Firewall”function.
Due tonatureofbroadcastUDPpackets, ETMhasfollowingcharacteristics:
□
□
□Broadcastpacketsaren’tlimitedbysubnet.Even ifIPaddressofthe
convertersandcomputerrunning ETMdo notbelong tothesamesubnet, it
still works fine.
□
□
□Broadcastpacketscan notpassrouters.ETMcanonlyusedtomonitor
deviceswithcomputerrunningETMinthesame segmentoflocalarea
network.
(Figure3.1)

19
Menu “View”
□
□
□View->RefreshF5
Refreshthestatus.ETMwillsendanotherquerytogetupdatedinformation
(see theFigure3.2).
Note: Alwaysrun the “View->Refresh”afterchange anydata.
(Figure3.2)
(
(Figure3.2)
View->ExitAlt+F4
Exitfrom theprogram(seeFigure3.2).
Menu “Config”
Config->IPAddress(see Figure3.3)
(Figure3.3)
(Figure3.3)

20
Press ENTERorselect[IPAddress]inthe[Config]menu,dialogwillbe
shown(see Figure3.4).
Note:BecauseETMusesbroadcastUDPpacketsforsakeofsecurity,it
allowsconfiguration onlywhendevice’ssetuppasswordisempty.
(Figure3.4)
(Figure3.4)
Assign IPAddresswiththesameSubnet Mask ofyourcomputer, avoiding
anyIPconflictwithothernetworkdevices.
When you press[Ok] button, the IPaddress willberefreshedin2~3
seconds(seethe Figure3.5).
(Figure3.5)
Table of contents
Other digi-tech Media Converter manuals