Digilock Curve User manual

PRODUCT GUIDE
Touch-Free RFID |Basic & Advanced
1
Aspire locks with a touch-free RFID interface are operated by an RFID credential or by an ADA compliant User Key. Manager
credentials (Manager Key or RFID credential) provide management access and/or external power. Programming is accomplished via
a Programming Key unique to the lock system. An optional mobile application tool simplies lock system management and provides
audit trail for locks with advanced functionality.
ASSIGNED USE FUNCTIONALITY
Front Unit Deadlatch Rear Unit
Cover Plate
½" (12.7 mm)
Deadlatch
Cover Plate Screw
Connection Options
Cable
Pin
RFID Credentials Key Insertion
Standard
Key Slot
Reader
Pull Handle
User Key Manager Key1Programming Key2
Operates the lock •••
Overrides user access • •
Allows management inspection • •
Provides external power • •
Programs Manager Keys to the lock •
Assigns user credentials3•
1Up to 6 manager credentials (Manager Key or RFID credential) may be programmed to each lock. If managed with the optional Mobile App, up to 250 manager
credentials may be programmed to each lock.
2One (1) Programming Key allowed per lock system.
3Up to 20 user credentials (User Key or RFID credential) may be programmed to each lock. If managed with the optional Mobile App, up to 250 user credentials may be
programmed to each lock.
RFID Card RFID Sticker RFID WristbandRFID Keyfob
LED Usage Indicator
Shared Use
Assigned Use
LOCK PARTS
KEYS

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
2
Locks are shipped with factory default settings (operates by presenting hand to lock). Each lock must be setup to operate with a
Programming Key and manager credentials (Manager Key or RFID credential).
Insert the Programming Key.
A two-tone beep will be heard
and the LED will flash.
While the LED is flashing, insert
one Manager Key or present
one Manager RFID credential at
a time.
A two-tone beep will be heard
for each manager credential
programmed.
Insert the Programming Key.
A two-tone beep will be heard
and the LED will turn off.
Repeat preceding steps for
each lock or follow instructions
to Express Register Manager
Credentials to setup all the
locks.
Express Register Manager Credentials
The Programming Key can quickly program the locks to operate with the same manager credentials.
Go to a lock already programmed to operate with the manager
credentials.
Insert and hold Programming Key in place for 10 seconds.
The LED will turn on and a two-tone beep will be heard after
5 seconds followed by two sets of two-tone beeps after 10
seconds.
Remove key and reinsert key.
Two sets of a two-tone confirmation beep will be heard and the
LED will turn off.
Insert the Programming Key to program
each lock to operate with the same
manager credentials.
Two sets of two-tone beeps will be heard
and the LED will flash once to indicate
successful programming.
End express registration mode.*
Go to any programmed lock and operate
it with the Programming Key.
Present hand to lock.
Then insert the Programming Key to
operate the lock.
*The Programming Key will continue to function in express registration mode until it is used to operate the lock.
RFID
CARD
or
132 4
1
3
2
54
sec
SETUP
PROGRAMMING INSTRUCTIONS

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
3
Insert and hold Programming
Key in place for 5 seconds.
The LED will flash, and a two-
tone beep will be heard after 5
seconds.
Once the two-tone beeps
are heard, remove key, then
reinsert key.
LED will continue to flash.
Insert each additional Manager
Key or present each Manager
RFID credential one at a time.
A two-tone beep will be heard
for each manager credential
programmed.
Insert the Programming Key.
A two-tone beep will be heard
and the LED will turn off.
Repeat preceding steps for
each lock or follow instructions
to Express Register Manager
Credentials to quickly program
the same manager credentials
to operate multiple locks.
Note the order or serial number (found on the lock’s rear unit). Contact Digilock Support to purchase a replacement
Programming Key.
Collect all remaining and
replacement manager
credentials.
Go to any lock operated by the
lost/stolen manager credentials.
Insert programming key and
hold for 5 seconds,
the LED will turn on and a two-
tone beep will be heard.
Remove programming key and
insert again, LED will flash.
Remove key and insert again.
Three sets of two-tone beeps
will be heard and the LED will
turn off.
All previously programmed
manager credentials will be erased.
Follow instructions to
Add Manager Credentials
to program the remaining
and replacement manager
credentials to the locks.
Replace the Programming Key
Replace the Manager Credentials
Add Manager Credentials
Manager credentials can be programmed to the locks at any time.
The locks must be reprogrammed to prevent the lost/stolen Programming Key or manager credentials from operating a lock.
RFID
CARD
or
132 4
1 2
1324
x3
sec
sec
PROGRAMMING INSTRUCTIONS - ADDING KEYS
PROGRAMMING INSTRUCTIONS - REPLACING KEYS & CREDENTIALS

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
4
Express Register User and Manager Credentials
The Programming Key can quickly program multiple locks to operate with the same user and manager credentials.
Assign User Credentials
Up to 20 user credentials (User Key or RFID credential) may be assigned to each lock.
Present hand to wake up the
lock.
Insert a valid Manager Key for 5
seconds.
A two-tone beep will be heard.
Remove the Manager Key.
The LED will flash.
Insert each User Key or present
each User RFID credential one
at a time.
Two sets of two-tone beeps
will be heard for each user
credential assigned to the lock.
Insert a valid Manager Key.
A two-tone beep will be heard
and the LED will turn off.
Go to a lock already programmed to
operate with the user and manager
credentials.
Insert Programming Key and hold for a
total of 15 seconds.
A two-tone beep will be heard after 5
seconds,.
Then followed by 2 sets of two-tone beeps
after 10 seconds.
Then followed by 3 sets of two-tone beeps
after 15 seconds.
The LED will flash.
Remove and reinsert the Programming
Key.
A two-tone beep will be heard and the
LED will turn off.
Insert the Programming Key to program
each lock to operate with the same user
and manager credentials. Two sets of
two-tone beeps will be heard and the
LED will flash once to indicate successful
programming.
End express registration.*
Go to any programmed lock, then present
hand to lock.
Then insert the programming key to
operate the lock.
RFID
CARD
or
*The Programming Key will continue to function in express registration mode until it is used to operate a lock.
1324
1
3
32
54
x3
sec
sec x1 sec x2
sec
PROGRAMMING INSTRUCTIONS

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
5
PROGRAMMING INSTRUCTIONS
Collect all remaining and replacement user credentials. Present hand to wake up the lock.
Insert Manager Key and hold for 5 seconds, a two-tone beep will
be heard.
The LED will turn on.
Remove and reinsert Manager Key, three sets of two-tone beeps
will be heard and the LED will turn off.
All previously assigned user credentials will be removed.
Follow Assign User Credentials instructions to assign the
remaining and replacement user credentials.
Remove User Credentials
The locks must be reprogrammed to remove user credentials from operating a lock.
1
3
2
4
sec

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
6
Operate with an Assigned User RFID Credential Operate with an Assigned User Key
Operate with a Manager Credential Operate with a Programming Key
Override with a Manager Credential Override with a Programming Key
Unlock
Unlock
Unlock
Unlock
Unlock
Unlock
Relock
Relock
Relock
Relock
Relock
Relock
In assigned use functionality, users operate the lock with their assigned user credential (User Key or RFID credential).
RFID
CARD
RFID
CARD
RFID
CARD
Present an assigned User RFID
credential.
Close the door.
Insert a valid Manager Key or
present a valid Manager RFID
credential.
Close the door.
Insert a valid Manager Key or
present a valid Manager RFID
credential.
Close the door.
Insert an assigned User Key. Close the door.
Present hand to lock, then
insert the Programming Key.
Close the door.
Present hand to lock, then
insert the Programming Key.
Close the door.
then
then
or
or
OPERATING INSTRUCTIONS - IN ASSIGNED USE FUNCTIONALITY
OPERATING/OVERRIDING INSTRUCTIONS - IN ASSIGNED USE FUNCTIONALITY

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
7
POWER JUMPING A LOCK WITH A MANAGER KEY
Insert and leave a valid Manager Key into the key slot until the
lock operates.
Open the door.
See Lock Battery Replacement instructions.
CAUTION: Risk of explosion or leakage if battery is replaced by an incorrect type, mixed with a different battery type, or inserted
backwards. Replace all batteries of a set at the same time. Be sure to insert batteries with correct polarities. Remove exhausted batteries
from product promptly and dispose of used batteries according to the battery manufacturer’s instructions.
Remove the 2 screws from the cover plate with a #1 Phillips
screw driver.
Slide battery cover plate back and lift up to expose the batteries.
Manager and Programming Key Battery Replacement
Remove the batteries from the housing. Replace with four
premium alkaline AAA batteries.
Replace the cover plate and secure with the screws.
or
12
1
3
2
4

PRODUCT GUIDE
Touch-Free RFID | Basic & Advanced
8
PG-D6CRX-P-DEN
For inquiries regarding new products, please contact our sales department: 707 766 6000 | [email protected]
For replacement products, returns, or technical support, please contact our support department: 707 766 6000 | [email protected]
080522
SUPPORT
Error Condition Indicators
10 rapid beeps:
The lock is binding which means that either door alignment or stored items are preventing the lock from operating. Press on the door
while operating the lock. If error condition persists, contact Digilock support for assistance.
2 sets of three beeps:
The batteries are low. Replace the batteries.
Does Not Unlock with a User Credential (User Key or RFID Credential)
The lock does not recognize the user credential. For immediate access, operate with a valid manager credential. Follow instructions to
Assign User Credentials to assign the user credential to the lock.
Does Not Operate with a Manager Credential (Manager Key or RFID Credential)
The lock does not recognize the manager credential. Follow instructions to Add Manager Credentials to program the manager
credential to the lock. For immediate access, operate with another valid manager credential or with the Programming Key.
Does Not Operate with the Programming Key
The lock does not recognize the Programming Key. If the Programming Key has been replaced, operate with the Replacement
Programming Key. Contact Digilock support for additional assistance.
No LED Response when Hand is Presented to Lock
• The batteries may need to be replaced. For immediate access, operate with a valid Manager Key.
• The front unit may not be properly connected to the rear unit. Remove the lock from the door and check the connection.
Remove the Cover Plate screw with a
Phillips head screwdriver.
Remove the Cover Plate by lifting the tab
at the edge of the cover, below the arrows.
Remove the batteries from the housing.
Replace with four premium alkaline AA
batteries. Dispose of or recycle used
batteries according to local regulations.
Replace the Cover Plate and secure with
the Cover Plate screw.
It is not necessary to remove the lock from the door. In case of battery failure, operate with a valid Manager Key.
CAUTION: Risk of explosion or leakage if battery is replaced by an incorrect type, mixed with a different battery type, or inserted
backwards. Replace all batteries of a set at the same time. Be sure to insert batteries with correct polarities. Remove exhausted batteries
from product promptly and dispose of used batteries according to the battery manufacturer’s instructions.
123
CONTACT INFORMATION
LOCK BATTERY REPLACEMENT
Other manuals for Curve
1
Table of contents