DirectOut Technologies D.O.TEC ANDIAMO.AES Installation instructions

DirectOut Technologies®
D.O.TEC®ANDIAMO.AES (SRC)
Version 1.0
Hardware Guide

page 2 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
Copyright Note
© 2013 DirectOut GmbH
Copyright
All rights reserved. Permission to reprint or electronically reproduce any docu-
ment or graphic in whole or in part for any reason is expressly prohibited, un-
less prior written consent is obtained from the DirectOut GmbH.
All trademarks and registered trademarks belong to their respective owners. It can-
not be guaranteed that all product names, products, trademarks, requisitions, regulations,
guidelines, specifications and norms are free from trade mark rights of third parties.
All entries in this document have been thoroughly checked; how-
ever no guarantee for correctness can be given.
DirectOut GmbH cannot be held responsible for any misleading or in-
correct information provided throughout this manual.
DirectOut GmbH reserves the right to change specifications at any time without notice.
DirectOut Technologies® and D.O.TEC® are registered trademarks of the DirectOut GmbH.
© DirectOut GmbH, 2013

DirectOut Technologies
®
page 3 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
Table of Contents
© 2013 DirectOut GmbH
Table of contents
ABOUT THIS MANUAL 5
How to Use This Manual 5
Conventions 5
CHAPTER 1: OVERVIEW 6
Introduction 6
Feature Summary 7
Applications 8
CHAPTER 2: LEGAL ISSUES & FACTS 10
Before Installing This Device 10
Defective Parts/Modules 10
First Aid (in case of electric shock) 11
Updates 12
Intended Operation 12
Conditions of Warranty 12
Conformity & Certificates 13
Contact 13
Contents 14
Accessories 14
CHAPTER 3: INSTALLATION 16
Installing the Device 16
CHAPTER 4: OPERATION 20
Introduction 20
Global Control 20
Menu Control 21
Clocking 22
Clocking continued - MADI STATE 24
Sample Rates 26
Output Format 28
User Bit Routing 29
Level Meters - digital I/O [AES] 30
Level Meters - digital I/O [AES SRC] 31
Signal Routing 32
MADI / Word clock / USB 34
AES3 Input / Output 36
CHAPTER 5: MENU NAVIGATION 38
Menu Navigation - Signal Routing [AES] 38
Menu Navigation - Signal Routing [AES SRC] 40
Menu Navigation - System Settings 42
CHAPTER 6: TROUBLESHOOTING AND
MAINTENANCE 45
Troubleshooting 45
Maintenance 45
CHAPTER 7: TECHNICAL DATA 46

DirectOut Technologies
®
page 5 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
About This Manual
© 2013 DirectOut GmbH
Conventions
The following symbols are used to draw your attention to:
Tips – indicate useful tips and shortcuts.
Notes – are used for important points of clarification or cross refer-
ences.
Warning
Warnings – alert you when an action should always be observed.
Use the Table of Contents at the beginning of the manual or Index
Directory at the end of the document to locate help on a particular
topic.
You can access more information and latest news by visiting on the
DirectOut website at www.directout.eu.
About This Manual
How to Use This Manual
This manual guides you through the installation and operation of the
ANDIAMO.AES (SRC).
This document relates to the ANDIAMO.AES and the ANDIAMO.
AES SRC. Split sections are marked with an individual side bar.
AES Version
AES SRC Version
ANDIAMO.AES
ANDIAMO.AES SRC

page 6 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 1: Overview
© 2013 DirectOut GmbH
CHAPTER 1: Overview
Introduction
Welcome to the ANDIAMO.AES (SRC), D.O.TEC’s compact con-
verter and router for MADI and AES signals.
The ANDIAMO.AES (SRC) provides two MADI inputs and outputs,
32 AES inputs and outputs.
With two RU height, two redundant power supplies, remote control
and a 128 x 128 crosspoint matrix the device offers highest versatil-
ity and safe operation at a minimal need of rackspace.
ANDIAMO.AES
ANDIAMO.AES SRC
The fi rst 16 AES inputs are equipped with sample rate converters
- switchable in groups of eight channels. [SRC Version only]

DirectOut Technologies
®
page 7 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 1: Overview
© 2013 DirectOut GmbH
Feature Summary
MADI Ports 2 x MADI input and output
2 x SC multi-mode connectors (SC/SC)
or
1 x SC multi-mode connectors &
1 x coaxial BNC connectors (BNC/SC)
MADI Formats 56/64 channel, 48k/96k Frame, S/MUX 2
AES Ports 32 x AES3 input (4 x DSUB-25 I/O) *
32 x AES3 output (4 x DSUB-25 I/O)
*) SRC Version: input SRCs switchable in
groups of eight channels for ports 01-16
Sample Rates 44.1, 48, 88.2, 96 kHz +/-12.5%
Clock Inputs 1 x Word clock coaxial BNC (75 Ω
termination switchable)
This input also accepts an
AES3 frame (AES11).
Clock Output 1 x Word clock coaxial BNC
USB Port USB 2.0 port for firmware
updates and remote control.
Routing Matrix Signal routing on a per channel
basis - 128 x 128 routing matrix.
Remote Control Software Remote control via USB,
Serial over MADI or MIDI over MADI
Power Supply This device is equipped with two wide
range power supplies (84 V to 264 V
AC / 47 Hz to 63 Hz / safety class 1).

page 8 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 1: Overview
© 2013 DirectOut GmbH
Applications
ANDIAMO.AES (SRC) can be used for conversion, distribution and
routing of digital signals.
Typical applications include:
• signal routing / distribution (128 x 128 cross points)
• conversion from / to AES to / from MADI
• integration of asynchronous AES signals [AES SRC]
• format conversion of MADI signals
• ...

DirectOut Technologies
®
page 9 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 1: Overview
© 2013 DirectOut GmbH
ANDIAMO.AES
ANDIAMO.AES SRC

page 10 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 2: Legal issues & facts
© 2013 DirectOut GmbH
CHAPTER 2: Legal issues & facts
Before Installing This Device
Warning
Please read and observe ALL of the following notes before
installing this product:
• Check the hardware device for transport damage.
• Any devices showing signs of mechanical damage or damage
from the spillage of liquids MUST NOT be connected to the
mains supply, or disconnected from the mains immediately by
pulling out the power lead.
• All devices MUST be grounded. The device is grounded
through its IEC power connections.
• All devices MUST be connected to the mains using the three-
cord power leads supplied with the system. Only supply
electrical interfaces with the voltages and signals described in
these instructions.
• Do NOT use the device at extreme temperatures. Proper op-
eration can only be guaranteed between temperatures of 5º C
and 45º C and a maximum relative humidity of 80 %, non-
condensing.
• The cabinet of the device will heat up. DO NOT place the
device close to heating sources (e.g. heaters). Observe the
environmental conditions.
Defective Parts/Modules
Warning
This device contains no user-serviceable parts. Therefore do NOT
open the device.
In the event of a hardware defect, please send the device to your
D.O.TEC®representative together with a detailed description of the
fault.
We would like to remind you to please check carefully whether the fail-
ure is caused by erroneous configuration, operation or connection be-
fore sending parts for repair. See „CHAPTER 6: Troubleshooting and
Maintenance“ on page 45 for assistance with troubleshooting.

DirectOut Technologies
®
page 11 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 2: Legal issues & facts
© 2013 DirectOut GmbH
First Aid (in case of electric shock)
Warning
• DO NOT touch the person or his/her clothing before power
is turned off, otherwise you risk sustaining an electric shock
yourself.
• Separate the person as quickly as possible from the electric
power source as follows:
Switch off the equipment.
Unplug or disconnect the mains cable.
• Move the person away from the power source by using dry
insulating material (such as wood or plastic).
• If the person is unconscious:
Check their pulse and reanimate if their respiration is
poor.
Lay the body down and turn it to one side. Call for a doc-
tor immediately.
• Having sustained an electric shock, ALWAYS consult a doc-
tor.

page 12 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 2: Legal issues & facts
© 2013 DirectOut GmbH
Updates
D.O.TEC®products are continually in development, and therefore
the information in this manual may be superseded by new releases.
To access the latest documentation, please visit the DirectOut web-
site: www.directout.eu.
Warning
No compensation can be claimed for damages caused by operation
of this unit other than for the intended use described above. Con-
secutive damages are also excluded explicitly. The general terms
and conditions of business of DirectOut GmbH are applied.
Conditions of Warranty
This unit has been designed and examined carefully by the manu-
facturer and complies with actual norms and directives.
Warranty is granted by DirectOut GmbH over the period of two years
for all components that are essential for proper and intended opera-
tion of the device. The date of purchase is applied for this period.
Warning
All claims of warranty will expire once the device has been opened
or modified, or if instructions and warnings were ignored.
For warranty claims please contact the dealer where your device
was acquired.
This guide refers to fi rmware version 1.0.
Intended Operation
The ANDIAMO.AES (SRC) is designed for conversion of audio sig-
nals from digital to digital. In this context digital audio refers to a
MADI signal (AES10) and AES signal (AES3).

DirectOut Technologies
®
page 13 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 2: Legal issues & facts
© 2013 DirectOut GmbH
Conformity&Certicates
CE
This device complies with the basic requests of applicable EU guide-
lines. The appropriate procedure for approval has been carried out.
RoHS
(Restriction of the use of certain Hazardous Substances)
This device was constructed fulfilling the directive on the restriction
of the use of certain hazardous substances in electrical and elec-
tronic equipment 2002/95/EC.
WEEE
(Directive on Waste Electrical and Electronic Equipment)
Due to the directive 2002/96/EC for waste disposal this device must
be recycled.
For correct recycling please dispatch the device to:
IMM Elektronik GmbH,
Leipziger Strasse 32
09648 Mittweida
Germany
Only stamped parcels will be accepted!
WEEE-Reg.-No. DE 93924963
Contact
Sales:
DirectOut GmbH, Leipziger Strasse 32, 09648 Mittweida, Germany
Phone: +49 (0)3727 6205-333 // Fax: +49 (0)3727 6205-56
www.directout.eu
Manufacturer:
IMM Elektronik GmbH, Leipziger Strasse 32, 09648 Mittweida,
Germany
Phone: +49 (0)3727 6205-0 // Fax: +49 (0)3727 6205-56
www.imm-gruppe.de

page 14 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 2: Legal issues & facts
© 2013 DirectOut GmbH
Accessories
D.O.TEC®BREAKOUT series
The BREAKOUT series are adaptor boxes - available in different
variants - to widen the application range of the D.O.TEC®ANDI-
AMO series.
Each box is equipped with XLR connectors at the front panel (AESid
uses BNC connectors) and DSUB-25 connectors at the rear panel.
Audio signals are carried passively between front and rear panel.
Contents
The contents of your ANDIAMO.AES (SRC) package should in-
clude:
• 1 x ANDIAMO.AES (SRC) (19’’, 2 RU)
• 2 x power chord
• 2 x fixing unit for power plug
• 1 x Hardware Guide
To complete the delivery please download from the DirectOut
website:
• Software Guide ANDIAMO Remote
• D.O.TEC®USB Serial driver
• ‘ANDIAMO Remote’ application
http://www.directout.eu/en/support/downloads/andiamo.aes.html
Two different models for digital signals are available:
BREAKOUT.AES - digital input / output, 8 AES ports (16 channels)
BREAKOUT.AESid - digital input / output, 16 AESid ports (32 channels)

DirectOut Technologies
®
page 15 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0© 2013 DirectOut GmbH
This page is left blank intentionally.

page 16 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 3: Installation
© 2013 DirectOut GmbH
Warning
Avoid damage from condensation by waiting for the device to adapt
to the environmental temperature. Proper operation can only be
guaranteed between temperatures of 5º C and 45º C and a maxi-
mum relative humidity of 80%, non-condensing.
Ensure that the unit has suffi cient air circulation for cooling.
Retain the protective cap if the optical port is unused. This will pro-
tect against soiling which can lead to malfunction.
CHAPTER 3: Installation
Installing the Device
1. Open the packaging and check that the contents have been
delivered complete and undamaged.
2. Fix the device in a 19’’ frame with four screws, or place it on
a non-slip horizontal surface.
4. Connect signal cable for the MADI signals.
ANDIAMO.AES (SRC) - SC/SC version
ANDIAMO.AES (SRC) - BNC/SC version
3. Remove the protective cap from the optical MADI port(s)
before use.

DirectOut Technologies
®
page 17 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 3: Installation
© 2013 DirectOut GmbH
Warning
This device MUST be connected to the mains using the three-cord
power leads supplied with the system. Only supply the voltages and
signals indicated (84 V – 264 V).
This device may operate with only one power supply. To provide
power supply redundancy, it is recommended to connect both PSU 1
and PSU 2 to independent power supplies with separate fuses.
5. Connect the signal cables1for the digital audio signals to the
DSUB-25 connectors (TASCAM pinout - see page 49).
1 signal cables are not included in delivery
7. Using the power cords provided connect both PSUs to a
matching power supply:
6. Optional: Connect an USB cable to the USB port for remote
control or fi rmware updates. This requires the D.O.TEC® USB
driver (Windows) being installed fi rst. The driver and the instal-
lation instructions are available at www.directout.eu.
Link: http://www.directout.eu/en/support/downloads/andiamo.aes.html

page 18 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 3: Installation
© 2013 DirectOut GmbH
To update the fi rmware an installed D.O.TEC® USB Serial driver (Win-
dows) and the D.O.TEC® Update Tool are necessary. The software
and the installation instructions are available at www.directout.eu.
Keep any packaging in order to protect the device should it need to
be dispatched for service.
Link: http://www.directout.eu/en/support/downloads/andiamo.aes.html
The fi rst seconds after switch-on the actual fi rmware is indicated by
the lower metering panel - e.g. fi rmware version 1.1.
8. Turn on the power switch and check the status of PSUs on
the front panel:
Use the D.O.TEC® Release Map to match your D.O.TEC® device
with the latest fi rmware or software release.
Link: http://www.directout.eu/upload/dokumente/dotec_release_map.pdf

DirectOut Technologies
®
page 19 of 56D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
CHAPTER 3: Installation
© 2013 DirectOut GmbH
9. Installation of D.O.TEC® USB Serial driver
• download the D.O.TEC® USB Serial driver
• download the ‘Installation Guide for USB Control’
Link: http://www.directout.eu/en/support/downloads/andiamo.aes.html
• follow the installation instructions in the ‘Installation Guide for
USB Control’
10. Installation of ‘ANDIAMO Remote’
• download the ‘Software Guide ANDIAMO Remote‘
• download the ‘ANDIAMO Remote’ application
Link: http://www.directout.eu/en/support/downloads/andiamo.aes.html
• follow the installation instructions in the ‘Software Guide AN-
DIAMO REMOTE’
11. Start the ‘ANDIAMO Remote’ application
• Check selected COM port or MIDI I/O
• Click ‘CONNECT’

page 20 of 56 D.O.TEC®ANDIAMO.AES (SRC) Hardware Guide - Version 1.0
DirectOut Technologies
®
CHAPTER 4: Operation
© 2013 DirectOut GmbH
Introduction
This chapter describes the basic operation of the device. Note that
throughout this manual, the abbreviation FS refers to sample rate or
sample frequency. So, when dealing with scaling factors, the follow-
ing sample rates can be written as:
• 44.1 kHz = 1 FS; 88.2 kHz = 2 FS
or
• 48 kHz = 1 FS; 96 kHz = 2 FS
The green LEDs (PSU 1 & PSU 2) indicate that a working power
supply is connected to the power supply unit. Note that an unlit LED
does not guarantee that the device is free of voltage. To ensure
that the device is completely disconnected from mains voltage, the
power chords must be disconnected.
Global Control
The control on the right of the front panel indicates the power sup-
ply. Power switches are on the back panel:
Power 2 Switches
Enable / disable power supply.
PSU 1 & PSU 2 2 LEDs (green): indicate the status
of both power supply units
LED OFF = Power supply inactive
LED ON = Power supply active
CHAPTER 4: Operation
This manual suits for next models
1
Table of contents
Other DirectOut Technologies Network Router manuals