Disinfect&Fog LRC-00125 User manual

Nano Atomizer
Ownership Manual

Nano Atomizer Ownership Manual
• Do not disassemble the product.
• Familiarize yourself with the product prior to use.
• Keep this product out of reach of children.
• When finished with the product, turn it o!and disconnect from the
main power supply.
To ensure correct use of the product, please read through all of the
following safety precautions before use to avoid property damage or
personal injury:
Safety Precautions
Product Name: Disinfectant Nano Atomizer
Product Model: LRC - 00125
Rated Power: 1300 W
Gross Weight: 1.70 KG
Product Size: 295 x 245 x 67 mm (power cord length: 230 mm)
Packing Size: 290 x 280 x 80 mm
Packing List: 1 main machine, 1 instruction manual, wrench and washers
Operating Voltage: 120 V
Net Weight: 1.52 KG
Specifications
Page 1

Page 2
• Whether the casing of the main engine or other components are
damaged.
• Whether the external parts/connectors of the main engine are
loose.
• Whether the accessories in the package are intact.
This product is factory packed. Please check the following prior to use:
Inspection of Product Before Use
2
4
6
7
8
5
3
1
1. Heat dissipation (fan)
2. Power Switch, Gear (Output) Level
3. Trigger
4. Nano Spray Nozzle (Hot while in operation)
5. LED’s for better view of surface
6. Safety buckle (must rotate to lock/unlock)
7. Disinfectant container (bottle)
8. Fluid filter
9. Gear Indicator (output level)
10. Touch Power Switch (hold for 3 seconds to turn o!)
Product Format
10
9
Nano Atomizer Ownership Manual

Nano Atomizer Ownership Manual
Remove the disinfectant container (clear bottle) by twisting (see lock/
unlock pic on bottle), turn upside down to reveal the seal. Open the seal
by pulling lightly on the tab, add the disinfectant until you reach desired
level. The markings on the side of the bottle indicate minimum and
maximum levels. Close the seal when finishing filling the container bottle.
Reinsert the container into the handheld, observing the lock/unlock
marking. The bottle should be securely in place before operation.
Powering on:
Plug the Nano Atomizer Handheld in a standard 120-volt circuit. Press the
Gear Position button to the first setting, labelled A. This will power up the
unit, the blue LED will flash while the internal heater comes to
temperature.
Once the LED stops flashing and remains solidly lit, you are ready for
use. Depress the trigger to start spraying atomized disinfectant.
NOTE: Hold down the Gear Position button for 3 seconds for powering
o!the unit. The fan will remain on to ensure airflow within the handheld,
this is normal. After startup, the atomizer will automatically shut down if
it’s standby time exceeds 90 seconds. If the hand switch is not released
after continuous use for more than 10 minutes, the automatic high-
temperature protection device will cause the machine to shut down for
safety purposes.
Directions for Powering On
Vehicle Interiors – Gear Position C or D
Electronics – Gear Positions B or C
Fabrics (sofas, drapes, etc) - Gear Positions A – D
Recommendations
Page 3

Page 4
NOTE: Please be advised not to add fragrance or essential oils. Blockage
due to added fragrance or essential oils is not covered by the warranty.
NOTE: The atomizer should not be sprayed onto the human body to
prevent scalding. In order to achieve the best Atomization e!ect, the
Nano nozzle should be tilted slightly downward when the atomizer is
activated. For reference, please consult our training videos.
www.disinfectandfog.com/training-videos
The Gear Position (labelled as A – E) determines the amount of
disinfectant being emitted from the nozzle.
NOTE: The nozzle will become very hot (warning on top of unit), do not
touch the nozzle, as it can cause a burn.
Maintain a distance of 2 – 2.5 feet from surfaces in order for the
disinfectant to be applied dry.
Press the power button to turn on the power supply, the machine will
preheat automatically (less than minutes), and atomize after preheating.
Once the blue light next to the nozzle lights up, atomization disinfection is
completed. The machine will automatically turn o!after 90 seconds of
standby time, or press and hold the power button for 3 seconds.
It is recommended to remove any disinfectant from the canister while
the unit is not in use.
How to Use
Nano Atomizer Ownership Manual

Nano Atomizer Ownership Manual
• Use alcohol based disinfectant products
• Drop this product to avoid damage. Do not use the product if it is
damaged.
• Rebuild, disassemble or repair this product. For circumstances
where product repair is required, please contact the store or
designated repair point where the product was purchased from.
• Place the product close to a fire source or in a high heat
environment.
When using this product, DO NOT:
When this product is not used for a long time, it should be checked
regularly and cleaned.
After using the atomizer, please wipe o!the residual disinfectant with a
clean paper towel or a dry rag.
Included with the unit is a wrench and washers. In the event the washers
around the nozzle wear out over time, you can use the wrench to remove
the nozzle and replace the washers. NOTE: Ensure the unit is completely
cooled down and unplugged before this operation is conducted.
Store this product in a dry environment.
Maintenance & Repair
Page 5

www.disinfectandfog.com
info@disinfectandfog.com
1-855-561-4512
Table of contents