DIVERSITECH 675-TS32H User manual

www.diversitech.com
Technical Support 1-800-995-2222
TOUCH SCREEN THERMOSTAT
INSTRUCTION MANUAL
675-TS32H 3 Heating and 2 Cooling
with Humidification and De-humidification

2 3
•7 Day programmable with 4 events
per day – including fan
•Large, easy to read dot matrix display
•True touch screen technology
•Automatic selection of cool
or heat mode
•Programmable fan mode
•Programmable filter monitor
•Programmable installer message
•Configurable humidification relay
•Independent de-humidification relay
•Customizable full and partial
lock security
•Adjustable differential settings
for multistage installations
•Energy watch calculates kWh
and HVAC costs
•Simple mode for
non-programmable usage
•Programmable Vacation Mode
675-TS32H
3 Heating and 2 Cooling with Humidity Control
Standard in all DiversiTech Touch Screen Thermostats: Complete and quick set-up with
gas, oil, electric, heat pump, air conditioning and multi-stage HVAC systems.

4 5
TABLE OF CONTENTS
Your Kit Includes: Outdoor Wireless Temperature Transmitter
+ Antenna + Receiver Module + 2 Batteries
This convenient feature provides you the outdoor temperature right
on your DiversiTech thermostat.
Outdoor Wireless Temperature Transmitter and Receiver Kit
TABLE OF CONTENTS .........................................................................................................5
GLOSSARY OF TERMS........................................................................................................6
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
SELECTING A LOCATION.....................................................................................................7
MOUNTING THE THERMOSTAT TO THE WALL ......................................................................8
WIRING LEGEND ................................................................................................................9
WIRING DIAGRAMS..........................................................................................................10
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
HOME PAGE.....................................................................................................................16
CONTROL PAGE ...............................................................................................................17
THERMOSTAT OPERATION MODES ....................................................................................18
TEMPERATURE SETPOINTS...............................................................................................19
HUMIDIFICATION AND DE-HUMIDIFICATION SETPOINTS.....................................................20
FAN OPERATION MODES ..................................................................................................22
MENU PAGE.....................................................................................................................23
MENU PAGE - DATE AND TIME SETTINGS..........................................................................24
MENU PAGE - PROGRAM SETTINGS ..................................................................................25
MENU PAGE - ENERGY WATCH .........................................................................................26
MENU PAGE - SCREEN OPTIONS .......................................................................................27
MENU PAGE - VACATION MODE ........................................................................................28
MENU PAGE - FILTER MONITOR ........................................................................................29
MENU PAGE - HUMIDITY CONTROL ...................................................................................30
MENU PAGE - ADVANCED SETTINGS.................................................................................31
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – WELCOME...................................................................................32
ADVANCED SETTINGS – CONFIGURING YOUR EQUIPMENT..................................................34
ADVANCED SETTINGS – DIFFERENTIAL SETTINGS ............................................................35
ADVANCED SETTINGS – TIMER FEATURE ..........................................................................36
ADVANCED SETTINGS – HEAT PUMP ................................................................................37
ADVANCED SETTINGS – HUMIDIFICATION & DEHUMIDIFICATION ........................................38
ADVANCED SETTINGS – CALIBRATION ..............................................................................41
SIMPLE THERMOSTAT MODE............................................................................................44
TROUBLESHOOTING .........................................................................................................45
IMPORTANT NOTICE ........................................................................................................46
WARRANTY .....................................................................................................................47

6 7
Anticipator control – Anticipator control
is used to turn off the heating equipment
before the room temperature actually
reaches the cut-out point.
Cut-in Point – The air temperature at the
thermostat at which it initiates action of
heating/cooling equipment.
Cut-out Point – The air temperature at the
thermostat at which it terminates action of
heating/cooling equipment.
Cycle rate – Cycle rate is the frequency
that heating or cooling equipment is turned
on during a certain period of time. Cycle rate
is often given in units of cycles per hour
(CPH).
Dehumidify – The process of removing
moisture from the air.
Dehumidifier – Device used to remove
moisture from the air.
Differential – Differential is defined as
the difference between the cut-in and
cut-out points as measured at the
thermostat under specified operating
conditions. For example, if the thermostat
turns the heating equipment on at 70
degrees F and turns the heating equipment
off at 74 degrees F, then the differential is
4 degrees F.
Humidifier – A device used to add
moisture to a space.
Humidistat – A control which is operates
the humidifier and is affected by changing
humidity.
Humidity – Moisture in the air.
Programmable thermostat – A thermo-
stat with the capability of automatically
adjusting temperature set point to pre-
selected settings at pre-selected times.
Setback – The automatic alteration of the
thermostat control point(s) by means other
than manually changing the temperature set
point.
Set point – The desired temperature
setting on an electromechanical or
electronic thermostat.
GLOSSARY OF TERMS DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
SELECTING A LOCATION
Install your DiversiTech thermostat approximately 5 feet (1.5 meters) above the floor in an
area with good air circulation.
Avoid the following locations:
• Hot or cold air from ducts
• Radiant heat for appliances or sun such as a skylight
• Unheated areas or uncooled areas:
for example an outside wall behind the thermostat.

8 9
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING LEGEND
TERMINAL EQUIPMENT STANDARD COLOR
Y1 First Heat Pump & AC Yellow
G Fan Green
W2 First Stage Furnace White
OBW Reverse Valve - Second Stage Furnace Orange
RH 24V AC Heat Red
Y2 Second Heat Pump & AC Unknown
C Common Blue
H Humidity Control Unknown
DH Dehumidity Control, Variable Fan Control Unknown
RC 24V AC Cool Unknown
11 & 12 Not Used
NOTE: The above colors are standard in HVAC industry. The wiring should be
confirmed before installation
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
MOUNTING THE THERMOSTAT TO THE WALL
1. Make sure to turn off the power supply located at the electrical service panel.
All heating and cooling units should be OFF.
2. Remove the cover plate by pulling up the cover from the left or right side only.
3. Align the thermostat unit to the wall.
4. Mark the two locations for drilling the 3/16” holes required for the plastic screw anchors.
5. Remove the thermostat and drill the two 3/16” holes in these locations.
6. Insert the plastic gyproc screw anchors and tighten them securely.
7. Make the appropriate wire connections based on the specifications of the
household HVAC unit(s). Please refer to Wiring Table to determine the appropriate
wire connections.
8. Securely mount the thermostat unit to the wall with the two supplied screws.
9. Fit the cover plate back by clipping one side first (left or right) and than push down
on the opposite side.
10. Turn on the electricity at the electrical service panel.

10 11
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
I2
1 AIR CONDITIONER
24V
FAN
AC
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON
AC2
I2
2 AIR CONDITIONERS
24V
FAN
AC1
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON
HEAT
I2
1 AIR CONDITIONER AND 1 HEAT
24V
FAN
AC
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON
HEAT 2
HEAT 1
I2
1 AIR CONDITIONER AND 2 HEAT
24V
FAN
AC
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON

12 13
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
HEAT
REVERSE VALVES
I2
1 HEAT PUMP AND 1 HEAT
24V
FAN
HP
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON
REVERSE VALVES
I2
1 HEAT PUMP
24V
FAN
HP
I1 RC DH H C Y2 RH OBW W2 G Y1
COMMON
I2
COMMON
2 HEAT PUMPS
HP2
24V
REVERSE VALVES
FAN
HP1
I1 RC DH H C Y2 RH OBW W2 G Y1
I2
COMMON
1 HEAT PUMP AND 2 HEAT
HEAT 2
24V
REVERSE VALVES
HEAT 1
FAN
HP
I1 RC DH H C Y2 RH OBW W2 G Y1

14 15
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION
WIRING DIAGRAMS
I2
HUMIDIFIER WITHOUT TRANSFORMER
24V
I1 RC DH H C Y2 RH OBW W2 G Y1
HUMIDIFIER 2nd WIRE
HUMIDIFIER 1st WIRE
HEAT
TRANSFORMER
COOL
TRANSFORMER
I2
2 TRANSFORMERS
I1 RC DH H C Y2
CUT
RH OBW W2 G Y1
I2
1 TRANSFORMER
I1 RC DH H C Y2 RH OBW W2 G Y1
HEAT
TRANSFORMER

16 17
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
CONTROL PAGE
®The DiversiTech thermostat Control Page provides you with an easy and
intuitive screen to set your thermostat- all functions are available at the
touch of a finger! To access the Control Page, simply touch the Home
Page Screen… anywhere!
1 Current Room Temperature
2 Relative Room Humidity (%)
3 Thermostat Control Mode: Run Program or Hold Temperature
4 Temperature Control Mode: Auto, Heat, Cool and Off
5 Fan Operation Mode; Fan Automatic, Fan Intermittent, Fan Off
6 Menu Page – Access all program features with this button
7 Humidity and Dehumidity Setpoint: to lower or raise as desired
8 Temperature Control Mode: Heat and Cool temperature set points allows you to
change, raise or lower set point as desired. In “Auto” mode touch the Heat/Cool
button (Heat or Cool will flash once selected), then raise or lower set points as desired.
9 Humidity Auto
10 Displays Installer Message: review important information
11 Returns to the Home Page
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
HOME PAGE
®To return to the Home Page, simply touch icon at any time!
Home Page displays the following information:
1 Current Room Temperature
2 ºF/ºC Indicator
3 Relative Room Humidity (%)
4 Thermostat Control Mode: Run Program or Hold Temperature
5 Temperature Control Mode: Auto, Heat and Cool
6 Fan Operation Mode: Fan Automatic, Fan Intermittent, Fan Off
7 Fan Operation Indicator
8 Heat Setpoint and Cool Setpoint
9 Date Stamp (Month/Day/Year)
10 Time: Choose between 12 hour or 24 hour clock
11 Outdoor Temperature
®Now that you know the basics let’s review the Control Page - and begin
to learn about all the unique features!

18 19
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
THERMOSTAT OPERATION MODES
• Your DiversiTech thermostat can run in Program Mode or can hold a fixed
temperature.
•RUN PROGRAM: Your custom program settings will be initiated - 4 events per
day including the fan mode
•HOLD TEMPERATURE: Allows you to raise or lower the temperature setpoint
by touching the heat/cool - to lower + to raise
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
TEMPERATURE SETPOINTS
•AUTO, HEAT, COOL AND OFF
Based on your HVAC equipment you can quickly and easily select the mode
of operation - Automatic • Heat • Cool • Off
• AUTO – choose your heat and cool temperature setpoints – the temperature
will automatically adjust according to the requirement
• HEAT – choose your Heat setpoint
• COOL – choose your Cool setpoint
• OFF - no heating or cooling
•PROGRAM TEMPERATURE SETPOINT:
• Choose HEAT: Heat will appear with a temperature range, select your temperature
• Choose COOL: Cool will appear with a temperature range, select your temperature
• Choose AUTO: A combined heat/cool button will appear – when heat flashes
– choose your temperature setpoint, touch the button to toggle to cool, then
set your temperature setpoint.

20 21
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
HUMIDIFICATION AND DE-HUMIDIFICATION SETPOINTS
•DE-HUMIDIFY: Allows you to reduce and maintain the relative humidity to a spe-
cific setpoint. Please note that this feature functions in the Cool Mode only. Your
DiversiTech thermostat must be configured to control a cooling unit such as an
air conditioner of heat pump. Once you choose De-Humidify follow these easy steps:
• The DH setpoint with – and + icons allow you to lower and raise your setpoint
• Example of typical use of the De-Humidify function: If the current humidity is 70% your
DiversiTech thermostat will initiate the humidifier to function until Setpoint 50% in this reached.
In order to de-humidify you must set the de-humidify setpoint below the current relative
humidity. Your DiversiTech thermostat will both lower and regulate temperature to the cool-
ing setpoint while monitoring and lowering the room humidity.
• Since the De-Humidify feature uses the Cool Function of your Air Conditioner or Heat
Pump, your DiversiTech thermostat will turn off the air conditioning if either the dehu-
midifier setpoint or temperature setpoint is reached – which ever comes first.
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
HUMIDIFICATION AND DE-HUMIDIFICATION SETPOINTS
®In order to reduce condensation, humidity must be controlled and air
movement must be generated. As the exterior temperature drops, the
humidity level needs to decrease if condensation is to be controlled.
•HUMIDIFY: Allows you to raise and maintain the relative humidity to a specific set-
point. Once you choose Humidify follow these easy steps:
• The HUM setpoint with – and + icons allow you to lower and raise your setpoint.
• Example of the typical use of the Humidify Function: If the current humidity is 30% your
DiversiTech thermostat will initiate the humidifier to function until Setpoint 50% is reached.
In order to humidify you must set the humidity setpoint above the current humidity.

22 23
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
FAN OPERATION MODES
• There are three modes of fan operation: Fan Auto, Fan On, Fan Off. When
the fan is running, the animated fan icon will appear on the Home Page.
•FAN AUTO: The fan will run on only when there is a demand for heating or cooling.
•FAN ON: The fan runs continuously
•FAN INTERMITTENT: The fan will run 10 minutes per 1/2 hour providing a
convenient way to improve air quality and save energy.
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE
®To access the Menu Page, simply touch Menu from the Control Page.
Remember it is as easy as a touch of the button.
• Set-up of your DiversiTech thermostat is effortless with intuitive menu driven
programming - on our patented touchscreen.
• Enter Date and Time Settings: Program 7 days with 4 events per day to
improve efficiency and reduce energy costs
•Energy Watch: display kWh consumption as well as the dollar cost of the
HVAC System - configure this feature in Advanced Settings
•Clean the Screen without worry
• Access the Set Screen menu
•Advanced Settings for configuration of equipment
•Vacation Mode
• View Filter Monitor
• Activate the Humidify/De-humidify Function

24 25
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - DATE AND TIME SETTINGS
•Select the 12 or 24 hour clock display.
•Set the time of day by choosing hour and minute buttons.
•Set the Month, Day and Year by choosing the buttons.
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - PROGRAM SETTINGS
•PROGRAM SETTINGS: This feature easily and quickly programs your
thermostat to fit your needs and lifestyle. Remember by programming the
thermostat you can increase energy efficiency and reduce energy.
• 7 Day Programmable with 4 events per day including Fan Mode
• Select the Day of the Week
• Select the Event number: for example 1
• Select the Start Time: for example 7:00 AM
• Choose desired temperature setpoint – by raising or lowering the heat/cool button
• Choose the next event: for example 2 and repeat the steps
Once you have set all the events for one day you may
copy the same settings to other days of the week. First
ensure that your program settings are correct. Then
select the next day of the week that you would like to
have the same program setting. DiversiTech thermo-
stat will then prompt you to copy the settings.
Remember that you must choose Run Program from
the Control Page to activate this feature.

26 27
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - ENERGY WATCH
•ENERGY WATCH: This unique and patented feature
provides a display of system energy consumption and
the cost of running your HVAC system. This feature
must be activated in the Advanced Settings - page 32.
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - SCREEN OPTIONS
•CLEAN SCREEN: This function allows you to safely wipe and clean the screen with
a dampened cloth with out accidentally changing any of the settings; it places the
DiversiTech thermostat screen in a sleep mode for 15 seconds.
•SET SCREEN: Your DiversiTech thermostat has a number of options to ensure clear
viewing throughout the day and night, firstly;
• Backlight: choose between Auto or ON
• Reverse: Choose between a dark background (ON) or light background (OFF)
• Night Reverse: Another patented feature – ON: at 9PM the screen automat-
ically reverses the background for comfortable viewing at night – at 6:00AM
it returns to the Normal Mode for clear daytime viewing. OFF: screen back-
ground determined by “Reverse” function setting.
• Contrast: Provides a range from 1 – 10 to lighten or darken the screen best
suit your surroundings – we advise the setting of 7.

28 29
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - VACATION MODE
•VACATION SETTINGS: Allows you to set the temperature to a fixed setpoint dur-
ing the time you are on vacation, providing energy savings and comfort for your return
home. IMPORTANT: Heat or Cool must be selected from the Control Page before
entering the Vacation Settings page. To begin select Vacation Mode ON:
• Select the Start Date
• Select the End Date
• Adjust the Heat or Cool temperature setpoint: the Vacation mode begins at 10
PM on the day of your departure and ends at Midnight on the day of your arrival.
• When the Vacation mode is active the suitcase icon will appear on the Home
Page. Upon your return from vacation, a message Vacation Mode Ended will
be displayed on the screen. Simply touch the
screen to acknowledge the message, and your
DiversiTech thermostat will automatically revert
to the Program Settings if you are in Run
Program Mode or your can choose to Hold
Temperature to raise or lower the setpoint.
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - FILTER MONITOR
•FILTER MONITOR: Displays filter usage in days and resets filter timer – when activated
the Filter Monitor icon will appear on your Home Page – this feature must be activated
in Advanced Settings.

30 31
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - ADVANCED SETTINGS
®IMPORTANT INSTALLER SET-UP
This DiversiTech thermostat works with many different HVAC systems –
Gas, Oil, Electric Heat Pump, 2 Stage Heat Pump, 2 Stage Furnace and
Compressors. You must enter this menu to configure the thermostat with
HVAC operating equipment, and to fully customize the thermostat.
ADVANCED SETTINGS: To begin, hold your finger for 5 seconds on the
Advanced Settings Button – you will hear a beep telling you that you are in the
process of entering this feature.
A warning message will appear:
CAUTION: INCORRECT CONFIGURATION
CAN DAMAGE YOUR SYSTEM, CONTINUE?
YES NO
ACCEPT – YES
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION
MENU PAGE - HUMIDITY CONTROL
•HUMIDIFY or DEHUMIDIFY: Choose this feature on the DiversiTech 675-TS32H
thermostat – remember your setpoint is on the Control Page.

32 33
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – WELCOME
•ºF: Choose between display units of Fahrenheit or Celsius for thermostat temperature
•SECURITY: The security settings allow you to protect your DiversiTech ther-
mostat from unauthorized use, and provides 2 levels of security. On your
Home Page once this feature is activated you will see a small lock icon.
• Turn Security On or Off – the Factory Setting PIN is 1111
• As a first time user you will be prompted to enter the Factory Setting PIN 1111
• Enter your new PIN and then Re-enter your new PIN once more.
• There are two modes of password protection: Full Lock Function does not allow
any changes unless the user enters the PIN. Partial Lock Function allows you to
change only the temperature setpoint without entering a PIN.
•INSTALLER MESSAGE: (up to 42 characters) to
appear at programmable intervals . Enter your
message on the screen using the keyboard – for
example service reminders or emergency contact
information. Type your message in using the keyboard,
upon completion choose OK. Set the number of
months after which you with the message to appear.
Touch the home or menu icon to exit
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – WELCOME
•HOME BUTTON: Returns you to the Home Page at anytime- remember you will
have to re-enter through the Advanced Settings button.
•DAYLIGHT TIME : Choose Daylight Time On or Off dependent on your Time Zone.
•FILTER: A Helpful reminder to change or clean your air filter. The Filter Monitor
function indicates how many days of "fan run time" the air filter has been used. Reset
it each time after changing your air filter.
•ENERGY WATCH: By entering the HVAC system con-
sumption parameters rounded off to kW, you will have
a real time total of kilowatts and cost of consumption.
To review touch the Energy Watch button on the Menu
Page. EXAMPLE: Fan 1kW, Heat Pump 1kW/ton,
Furnace 5-30 kW, 7-9¢/kW
• This feature will run consecutively for 255 days. If
you do not enter your information what will appear on
the display is the total time the Compressor and the
Furnace have been operating.

34 35
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – CONFIGURING YOUR EQUIPMENT
®IMPORTANT: BY INADVERTENTLY MODIFYING COMPRESSOR
AND FURNACE SETTINGS, YOU MAY SERIOUSLY DEGRADE SYS-
TEM PERFORMANCE.
®CHOOSE SYSTEM HEATING AND/OR COOLING EQUIPMENT –
REMEMBER ALL YOU NEED TO DO IS TOUCH THE BUTTON WITH
YOUR FINGER.
• Choose Heat Pump, 2 Stage Heat Pump, Air Conditioning, No Compressor – please
review the wiring table and diagram for wiring instructions.
• Choose Furnace Off (No Furnace), Electric Furnace, Emergency Electrical Furnace
(additional electric furnace which will come on in emergency mode in conjunction
with electric furnace), Gas Furnace, Oil Furnace, and 2 Stage Gas Furnace; please
review the wiring table and diagram for wiring instructions.
•CYCLE RATE: Set Maximum compressor cycles per hour.
•AUTO CHANGE: Set the minimum difference between Auto Mode, Heat and Cool
temperature set points.
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – DIFFERENTIAL SETTINGS
®THE DIVERSITECH 675-TS32H THERMOSTAT ALLOWS YOU TO
CONTROL UP TO 3 STAGES OF HEATING AND 2 STAGES OF
COOLING, DEPENDENT ON THE TYPE OF SYSTEM YOU HAVE
CONFIGURED.
•1ST STAGE DIFFERENTIAL: Set temperature difference between temperature set point
and actual temperature reading before 1st stage heating or cooling is initiated.
•2ND STAGE DIFFERENTIAL: Set temperature difference between 1st stage initiation
and 2nd stage heating or cooling initiation.
•3RD STAGE DIFFERENTIAL: Set temperature difference between 2nd stage initiation
and 3rd stage heating or cooling initiation.
•OB ENERGIZED: Reverses the Heat Pump OB Valve contact to HEAT or COOL
(manufacturer dependent).

36 37
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – TIMER FEATURE
• Specify the number of minutes for which Stage 1 will function until Stage 2 is
activated to help raise (or cool) temperature (if the temperature set point is not
reached). This unique function avoids excess compressor wear in the case where
the necessary temperature set point is not met through setting of the Staging
Differentials. Set to “00” to disable.
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – HEAT PUMP
• HP “ON” when Furnace On: Heat Pump and Furnace can operate together when
2nd stage furnace is required. HP “OFF” when Furnace On: turns off the Heat Pump
when the furnace is On (required on some gas or oil furnaces).

38 39
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – HUMIDIFICATION & DEHUMIDIFICATION
•HUM FAN: ON: fan runs when there is an independent demand to humidify. OFF:
fan only runs when there is a demand to humidify while heating or cooling.
•DH FAN: ON: fan runs when there is an independent demand to dehumidify. OFF:
fan only runs when there is a demand to dehumidify while cooling.
•DH REVERSE: ON: DH relay is normally closed when relative humidity is above DH
set point. OFF: DH relay is normally open when relative humidity is above DH set point.
•DH CONTROL COMPRESSOR: ON: Thermostat will turn off the air conditioning
if either the dehumidify set point or the temperature set point is reached, whichev-
er comes first, both DH relay and compressor will turn off. OFF: DH relay is inde-
pendent of compressor activity (DH becomes a spare relay and can be used for a
variable speed fan or separate dehumidifier or air exchanger)
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – HUMIDIFICATION & DEHUMIDIFICATION
®OPERATING TIPS
•Humidification Fan should be set to on when running steam or mist humidifiers.
•Humidification Fan should be set to off when running drum humidifiers or any
other humidifier that requires the furnace to run in order to make humidity.
•De-Humidification Fan (DH) should be set to on when running separate de-humid-
ification equipment.
•De-Humidification Fan (DH) may be set to off when using the air conditioning as a
means of de-humidification. It may advantageous in some environments to turn the
fan on independently when there is a call for DH in order to distribute the humidity
level more evenly.
• The DH REVERSE function can be configured to meet the requirements of many
variable speed fans, consult the manual of your variable speed fan and determine
if an “open” or “closed” contact results in slowing fan operation.
Table of contents