Dixon Bayco 6200X Manual

Installation & Operating
Instructions
For
Dixon Bayco
6200X and 6500X Tall
Drop Elbows
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario
Phone: 705-436-1125
Fax: 705-436-6251
Toll Free: 877-963-4966
E-mail: isales@dixongroupcanada.com
USA:
Dixon Bayco USA
Chestertown, Maryland
Phone: 410-778-2000
Fax: 410-778-4702
Toll Free: 800-355-1991
E-mail: dixonbayco@dixonvalve.com
Mexico:
Dixva, S. de R.L. de C.V.
Monterrey, N.L
Phone: 01-800-00-DIXON (34966)
Fax: 01-81-8354-8197
E-mail: contactenos@dixonvalve.com.mx
Europe:
Dixon Group Europe Ltd
Preston, England
Phone: +44 (0)1772 323529
Fax: +44 (0)1772 314664
E-mail: enquiries@dixoneurope.co.uk
Asia Pacific:
Dixon (Asia Pacific) Pty Ltd Wingfield,
South Australia
Phone: +61 8 8202 6000
Fax: +61 8 8202 6099
E-mail: enquiries@dixonvalve.com.au
dixonvalve.com
For Sales and Service Contact

6200X and 6500X Tall Drop Elbows
2 090086 R6 6200X & 6500X

6200X and 6500X Tall Drop Elbows
6200X & 6500X 090086 R6 3
This elbow is designed for use with standard 4" top seal service
station adapters. To properly operate and maintain your Dixon Bayco
6200X series elbow the following instructions are provided. Please
read with care as improper handling or maintenance may cause a
hazardous condition.
Do not modify your Dixon Bayco 6200X / 6500X series
elbow for any reason. It can result in a hazardous condition due
to operating difficulties or operation malfunction. Disassembly
or tampering will void the product warranty.
Never smoke or allow an open flame near your dispenser when
handling volatile materials such as gasoline and fuels. An explosion
could result. Remember safety is everyone’s business.
Installation
1. When the Dixon Bayco 6200X / 6500X elbow is shipped, the sight
glass and gaskets are attached in a plastic bag attached to the
elbow. These must be installed with the required mating Bayco inlet
(3" or 4" male or female purchased separately).
2. Take the sight glass and gaskets out of the plastic bag and place
one gasket inside the elbow inlet end and make sure it is sealed
evenly.
3. Carefully (keep straight) slide the sight glass into the inlet end and
onto the installed gasket.
4. Place the other gasket inside the inlet and on the sight glass.
5. Attach the mating inlet using the four socket head cap screws
supplied.
6. Coat the cap screws with anti-seize compound.
Lubricate Stem
This product has been assembled with anti-seize compound and
lubricated for easy maintenance and trouble-free service. However,
we recommend lubricating the stem through the grease nipple using
lithium based or quality automotive type grease prior to service. It is
recommended to apply lubricant to grease nipple, cam arm bearings,
and other moving parts every month. Monthly inspection and
lubrication become mandatory for items that are seldom used.
Condensation, rain and road salts can cause corrosion build-up and
binding when product not in use.

6200X and 6500X Tall Drop Elbows
4 090086 R6 6200X & 6500X
Check Operation
1. Place elbow bottom end on service station adapter (elbow is
designed for use with 4" top seal adapter only).
2. Move operators handle to 11 o’clock the open/unclamped position.
3. Release and hold the safety latch if equipped with one. Move the
handle clockwise to 2 o’clock position for full clamping (lever cannot
be moved any farther).
3. Check locking arms on adapter. If the elbow is fitted with a safety
latch, make sure the stem pin is in the latch notch, preventing
movement of operating handle.
4. Release by moving handle to 11 o’clock. If fitted with safety latch,
lift the latch lever and operating lever at the same time.
Care and Handling
Dixon Bayco drop elbows are tested at the factory and are in proper
working condition when shipped. Drop elbows are designed to be
tough and to provide long service with reasonable care and handling.
To ensure long service, Dixon Bayco elbows should not be thrown,
dropped or dragged; such actions may compromise the integrity and
reduce the service life of the product.
Inspection
Drop elbows can fail to operate if not properly maintained. If the
6200X / 6500X elbow develops any problems, remove from service
and contact your Dixon Bayco distributor describing the difficulty. The
distributor will provide further instructions repair and warranty of the
product.
Elbows should be inspected monthly. Check the main gasket seal,
the sight glass, and the flange where the base is attached to the
elbow body for any signs of leakage. Change seals if necessary.
Check the sight glass for cracks or damage and replace if needed.
Check and tighten all fasteners periodically. Lubricate the lever stem.
Check the bushings and replace if cracked or worn, and change if
required. Check operation as per above.

6200X and 6500X Tall Drop Elbows
6200X & 6500X 090086 R6 5
Regularly replace bushings. All Dixon Bayco 6200 / 6400 / 6500
series elbows contain polymer bushings, which protect and extend
service life of bronze locking arms. The bushings are designed to
wear (instead of bronze arms) and should be replaced every few
months. Operators must be encouraged to inspect and replace
polymer bushings to obtain maximum elbow performance and
longevity.
Optional Accessories
The following are available as optional accessories for 6200X /
6500X elbows:
Anti-spill sleeve #6200X-17
Safety latch kit #6200SLK
Installation instructions are included with the items when ordered for
retrofit.