DNF Controls 2034CL-L-PBIO User manual

12034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
12843 Foothill Blvd. Suite C
Sylmar, California 91342
V: 818.898.3380
F: 818.898.3360
sales@dnfcontrols.com
Model No. 2034CL-L-PBIO
(&2034CL-L-T)
300 CLIP INSTANT ACCESS SYSTEM
Louth Protocol
VERSION 3.0 SOFTWARE
Note: Supports up to 3 Video Server Channels
User Manual

22034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
Table of Contents
1. REVISION HISTORY 4
GETTING STARTED . . . 5
2. SYSTEM DESCRIPTION 5
DEFINITIONS 5
3. SYSTEM INSTALLATION 6
A. SHOTBOX 6
B. ST300 CONTROLLER 6
C. PRODUCTION SWITCHER 7
4. VIDEO SERVER SETUP 9
5. LOAD ACLIP 9
6. LEARN ACLIP OR CLIP COMBINATION 10
A. LEARN ON THE SHOTBOX 10
B. LEARN ON THE PRODUCTION SWITCHER 10
C. LEARN ON THE ST300 10
7. RECALL 11
A. RECALL ON THE SHOTBOX 11
B. RECALL ON THE PRODUCTION SWITCHER 11
C. RECALL ON THE ST300 11
8. SHOTBOX SHOTKEY MAPPING TO SHOTLIST LOCATIONS 11
9. PBIO REGISTER MAPPING TO SHOTLIST LOCATION 12
10. TRIGGER 12
ADVANCED . . . 13
11. CREATE ACLIP 13
A. SET THE RECORD DURATION 13
B. CREATE ANEW NAME 13
C. RECORD ACLIP 14
12. CREATING SUBCLIPS 15
A. MARK IN (OUT) POINT 15
B. DELETE IN (OUT) POINT 15
C. MANUALLY ENTER IN (OUT) POINT 15
D. CREATE SUBCLIP 15
13. RECUE THE CURRENTLY LOADED CLIP 16
14. VIEW THE CLIP ID OF THE CURRENTLY LOADED CLIP 16
15. VIEW CONTENT OF CUE POINTS ON THE SHOTBOX 17
16. SHOTBOX CONTROL SWITCHES 17
17. CLEAR SINGLE CUEPOINT 17
18. TRANSFERRING CUELISTS 18
A. TO TRANSMIT CUE POINTS TO THE ST300 18
B. TO TRANSMIT CUE POINTS TO THE PC 18
19. RECEIVE CUELIST FUNCTION. 19
A. TO RECEIVE CUE POINTS FROM THE ST300 19
B. TO RECEIVE CUE POINTS FROM THE PC 19

32034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
REFERENCE . . . 20
20. SETUP MENU 20
21. FUNCTION TABLE 23
22. SPECIFICATIONS 24
ST300 24
RS422 SERIAL CONNECTOR 24
AUX PORT RS422 SERIAL CONNECTOR 24
GPI IN/OUT CONNECTOR 25
ST420 (SHOTBOX) 25
RS422 SERIAL CONNECTOR 25
POWER CONNECTOR 25
23. TROUBLESHOOTING 26
A. ST420 TROUBLESHOOTING 26
B. VERSION 3.0 HARDWARE OF ST300 ONLY 26
24. KEY LAYOUT 27
25. DNF CONTROLS LIMITED WARRANTY 28
Manual Version.....................…............................... 1.5 020504
Document ID............................... 2034CL-L-PBIO User Manual

42034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
1. REVISION HISTORY
070103 Rev. 1.1 Added Section CLEAR SINGLE CUEPOINT, and Key Layout.
Added the following to SETUP MENU.
CLIP SOM
RECALL MODE
VIDEO STANDARD
110303 Rev. 1.2 Added DNF Controls Limited Warranty.
Updated Receive Cue List & Transmit Cue List Function description.
120903 Rev. 1.3 Added CREATING SUBCLIPS section.
012204 Rev. 1.4 Changed Key Layout.
020504 Rev. 1.5 Added note to cover and System Description: Supports up to 3 Video
Server Channels.

52034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
Getting Started . . .
2. SYSTEM DESCRIPTION
NOW, production switchers can load & play video clips on Grass Valley Group
PROFILE and other video servers.
Use the EMEM or SNAPSHOT Learn & Recall functions of the production switcher to
load and play a video clip from a Recall or timeline.
Use the Run and Trigger functions of the production switcher to Play, Stop or Recue the
video clip. Instantly load a video clip at the press of a button.
Instantly load a FILL clip & KEY clip at the press of ONE button, then play out both
channels in sync.
The 300 Clip Instant Access System consists of the ST300-SSM VTR Controller, STS420
Shotbox and Shotlist Software.
The ST300 controls up to 3 video channels individually or ganged.
SHOTLIST provides fast access to existing video clips stored on Grass Valley Group’s PROFILE,
other DDR, VDR or Video Server supporting Louth Protocol.
The SHOTLIST contains up to 300 CLIP IDs, stored in non-volatile memory in the ST300.
Any clip in the SHOTLIST can be quickly loaded by simply entering the associated 3-digit
number of its location, then pressing [LOAD]. Press [PLAY] to play the clip.
Press [RECUE] to recue to the beginning of the clip or to the “recalled” time if defined.
Upon receipt of the Learn command, the ST300 saves the CLIP IDs of the currently loaded clips,
the current time of each clip, the VTRs they are loaded on and the current GANG mode into the
appropriate Cue Point.
When the RECALL command is received, the ST300 loads the learned Clips onto the learned
VTRs, cues the Clips to the learned time and restores the learned GANG mode.
Learn & Recall may also be done directly from the ST300.
DEFINITIONS
Throughout this manual, VTR, DDR, VDR & Video Server will be referred to collectively as
“Video Server.”
The ST300-S/SM is referred to as the ST300.
The ST420 SHOTBOX is referred to as “SHOTBOX.”
SHOTKEY refers to the 1-30 switches on the SHOTBOX.
Words surrounded by brackets, for example, [ENTER], are keys on the ST300 or the SHOTBOX.
[XXX] + [XXX] means hold the two keys down simultaneously.

62034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
3. SYSTEM INSTALLATION
a. SHOTBOX
1) Plug one end of a standard 9-pin, RS422 serial cable into the OUTPUT
connector on the rear of the SHOTBOX. Plug the other end of the
cable into the AUX connector on the rear of the ST300.
2) Connect the 5 VDC, 1Amp POWER SUPPLY into the POWER connector on
the rear of the SHOTBOX. Plug the POWER SUPPLY into an outlet, 90 VAC
to 240 VAC.
b. ST300 CONTROLLER
1) Plug one end of a 9-conductor, RS422 serial cable into the VTR 1 (2, 3 or 4)
connector on the rear of the ST300. Plug the other end of the cable into the
9-pin REMOTE connector on the Video Server.
2) Connect the +5, +12, -12 VDC POWER SUPPLY into the POWER connector
on the rear of the ST300. Plug the Power Supply into an outlet, 90 VAC to 240
VAC.
3) Assign logical Louth ports to ST300’s VTR connectors.
a) Press [MENU].
b) Turn the Wheel until VTR Louth Address is displayed.
c) Press VTR[1], VTR[2], or VTR[3] to select VTR.
d) Assign a Louth Port address for that VTR 0-9. (0 turns that channel
OFF.)
e) The second line of the display will show “Input=Enter, Out=ESC”
f) Press [ENTER] to select an Input Port.
(A “-“ will appear in front of the selected number.)
OR
[ESC] to select an Out Port.
g) Repeat steps c-f to assign a Louth Address to ALL VTRs you want to
use.
h) Press [ESC] to leave the MENU mode.
4) Check the other options in the SETUP MENU prior to using the ST300 to
confirm proper Record mode and other User settable modes.

72034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
c. PRODUCTION SWITCHER
1) Connect a standard cable (RS422, 9-pin serial cable) to the supplied turnaround
adapter. Plug the turnaround adapter into the “VTR4” connector on the rear of
the ST300. Connect the other end of the cable to the Peripheral Bus Connector
on the production switcher. (Communication Format- 38.4K, 8,1)
2) To select a Production Switcher type (Default = Grass Valley Group).
a) Press [MENU] and turn the Wheel until “SWITCHER” is displayed.
b) Press Softkeys to toggle between Sony and Grass Valley.
c) Press [ESC] at anytime to exit MENU mode.
3) The ST300 has 4 Peripheral Device Addresses, one for each VTR that it
controls.
To set the Device Address for each VTR:
a) Press [MENU] and turn the wheel until “Peripheral Address” is
displayed.
b) Press VTR[1], VTR[2], VTR[3] or VTR[4] to select a VTR.
c) Assign a Peripheral Device Address for that VTR, from 0 to 23, by
entering the desired address using the numeric keypad.
OR
Press [DEL] to turn off the device.
d) Select the next VTR and assign a Peripheral Device Address for it.
e) When done, press [ESC] to exit MENU mode.
4) Select Parity:
a) Press [MENU] and turn the Wheel until “Parity” is displayed.
b) Press Softkey to select ODD, EVEN or NONE parity to match the
settings on the Production Switcher.
c) Press [ESC] to exit menu mode.
5) Configure the production switcher:
On the production switcher –
Enable the Peripheral Bus.
Enable the Peripheral Device Addresses assigned to the ST300.
Enable the appropriate Learn/Recall levels.
Enable the Timeline or Recall Trigger function.

82034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
Installation is complete.

92034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option
4. VIDEO SERVER SETUP
Select LOUTH Broadcast communications protocol on the VIDEO SERVER to be controlled.
If required, assign a serial port on the VIDEO SERVER through which the ST300 will control it.
NOTE: In LOUTH mode, the VIDEO SERVER ONLY allows Full Record.
(INSERT and ASSEMBLE record modes are disabled.)
Setup is complete.
5. LOAD A CLIP
a. Select a VTR by pressing VTR[1], VTR[2], or VTR[3].
b. Press [CLIP LIST] to view the list of CLIP IDs that are resident on the Video Server.
The CLIP LIST indicator will turn on.
c. Press [LOAD] to create and load a new clip.
(Creating a clip is described in “CREATE A CLIP,” Section 11.)
OR
Turn the Wheel to view the existing CLIP IDs on the video server.
Turn the Wheel clockwise to scroll forward, or counter-clockwise to scroll backward,
through the list of available CLIPs. Backward scrolling is limited to the last 10 CLIP IDs
viewed.
OR
Manually enter a clip ID using the ST300 numeric keypad, or Shotbox Qwerty keyboard.
d. Press [LOAD] to load the selected CLIP ID for playout.
e. Locate the clip to the desired IN time.
f. Repeat steps a-e until clips are loaded into the desired VTRs.
g. Set the GANG mode, if required.

10 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
6. LEARN A CLIP OR CLIP COMBINATION
a. LEARN ON THE SHOTBOX
1) Press [LEARN] on the ST420. The LEARN indicator will turn on.
2) Select the desired BANK and ShotKey.
3) The Learned CLIP ID will be displayed on the pressed key.
NOTE: This will overwrite what you have assigned to the key previously.
4) The ST300 will remember the loaded clip(s), current time and gang
configuration of the active VTR(s).
5) Press [LEARN] to exit at any time.
NOTE: The [LEARN] key toggles LEARN mode on/off.
b. LEARN ON THE PRODUCTION SWITCHER
1) On the ST300, load a clip(s) on the desired VTR(s). (See “LOAD A CLIP,”
Section 5.)
2) Select and enable the Peripheral Device Addresses for the ST300.
3) Do a LEARN to the desired REGISTER.
The ST300 will save the VTR #, loaded CLIP ID and current IN time into the
REGISTER number in the ST300.
c. LEARN ON THE ST300
1) Select the desired Cue Point by pressing [NEXT CUE], [LAST CUE] or by
manually entering the Cue Point using the numeric keypad.
The selected Cue Point number is shown on the bottom line of the display.
3) Press [SHIFT] + [MARK] to initiate the LEARN.
The display will show:
4) Press the VTR key desired, [1], [2], [3].
5) Press [MARK] and the ST300 will:
LEARN (save) the VTR Number (1,2,3), loaded CLIP ID and current IN time to
the selected Cue Point.
Select VTR:
LEARN-Lrn ESC-Cancel

11 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
7. RECALL
a. RECALL ON THE SHOTBOX
Select the desired Cue Point by pressing the BANK and ShotKey.
The ST300 will automatically load the Learned clips on the Learned VTRS, cue the clips
to the Learned time, then set the Learned GANG mode.
b. RECALL ON THE PRODUCTION SWITCHER
Recall the desired REGISTER NUMBER.
The ST300 will automatically load the Learned clips on the Learned VTRs, cue the clips
to the Learned time, then set the Learned GANG mode.
c. RECALL ON THE ST300
1) Select the desired Cue Point by pressing [NEXT CUE], [LAST CUE] or by
manually entering the Cue Point using the numeric keypad.
The selected Cue Point number is shown on the bottom line of the display.
2) Press [LOAD] on the ST300.
The ST300 will automatically load the Learned clips on the Learned VTRs, cue
the clips to the Learned time, then set the Learned GANG mode.
8. SHOTBOX SHOTKEY MAPPING TO SHOTLIST
LOCATIONS
The SWITCHES on the SHOTBOX access the SHOTLIST locations as follows:
BANK 0, SWITCHES 1 Æ30 access SHOTLIST locations 001 to 030.
BANK 1, SWITCHES 1 Æ30 access SHOTLIST locations 101 to 130.
BANK 2, SWITCHES 1 Æ30 access SHOTLIST locations 201 to 230.
BANK 3, SWITCHES 1 Æ30 access SHOTLIST locations 301 to 330.
BANK 4, SWITCHES 1 Æ50 access SHOTLIST locations 401 to 430.
BANK 5, SWITCHES 1 Æ30 access SHOTLIST locations 501 to 530.
BANK 6, SWITCHES 1 Æ30 access SHOTLIST locations 601 to 630.
BANK 7, SWITCHES 1 Æ30 access SHOTLIST locations 701 to 730.
BANK 8, SWITCHES 1 Æ30 access SHOTLIST locations 801 to 830.
BANK 9, SWITCHES 1 Æ30 access SHOTLIST locations 901 to 930.

12 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
9. PBIO REGISTER MAPPING TO SHOTLIST
LOCATION
Register 0-30 ÎCue Point 0-30
Register 31-60 ÎCue Point 101-130
Register 61-90 ÎCue Point 201-230
Register 91-99 ÎCue Point 301-309
10. TRIGGER
The operator fires a trigger using the Timeline or Run function on the production switcher. The
ST300 puts the Video Server into the following modes based on the trigger value:
GRASS VALLEY GROUP
Trigger Value Mode
0 Play
1 Recue to beginning of clip
2 Slo-mo using ST300 Preset Speed
3 Reverse Play
4 Still Frame
5 Play
6 Record
7 or greater Play
SONY
Trigger Value Mode
0 Recue to beginning of clipPlay
1 Play
2 Slo-mo using ST300 Preset Speed
3 Reverse Play
4 Still Frame
5 Play
6 Record
7 or greater Play
To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR
GANG the required VTRs on the ST300. See the Menu Table for GANG instructions. Enable the
Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to the enabled
VTR. The other VTRs in the GANG will perform the same action.

13 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
Advanced . . .
11. CREATE A CLIP
NOTE:New clips can be created ONLY if the INPUT Port is selected.
a. SET THE RECORD DURATION
1) Press [SHIFT] + [REC].
2) The display shows current record duration. The second line of the display
shows “Enter Record Length” prompt.
3) Enter the desired record duration using the ST300’s numeric keypad.
4) Press [ENTER] to save the new record duration and exit.
OR
Press [ESC] to exit without saving.
NOTE: Set Factory Defaults (in the SETUP MENU) sets the record duration to
1 hour.
b. CREATE A NEW NAME
1) Press [CLIP LIST]. The CLIP LIST indicator turns on. The display will show
“CREATE NEW CLIP.”
2) Press [LOAD]. The display will show the default CLIP ID.
3) Press [LOAD] to accept the default CLIP ID.
OR
Use [NEXT CUE], [LAST CUE] and Wheel to create a CLIP ID. Use the
[NEXT CUE] and [LAST CUE] keys to position the cursor. Turn the Wheel to
select the desired letter.
OR
Create an ID using the numeric keypad, with a maximum of eight characters if
extended IDs are OFF, and maximum of 20 characters if extended IDs are ON.
Press [ENTER].
4) Press [LOAD] to create the selected CLIP ID. If the selected CLIP ID already
exists, a warning message will be displayed. To load the existing clip, press
[ENTER]. Press [ESC] to exit without loading the existing clip.

14 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
c. RECORD A CLIP
NOTE: To record a clip, the video server must have enough memory to record the entire
clip. Video input must be connected to the Record Channel.
The ST300 Port selected for recording must be an Input Port [a ”-“ (minus) number].
1) Set the desired record duration as described in Section 11.a., “SET THE
RECORD DURATION.”
2) Create a new name as described above in Section 11.b., “CREATE A NEW
NAME.”
3) Press [RECORD] to start recording.
4) Press [STOP] to stop recording.

15 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
12. CREATING SUBCLIPS
a. MARK IN (OUT) POINT
1) Press [IN] ([OUT]) key.
2) The current Timecode is saved as [IN]([OUT]) point. IN ([OUT]) indicator
turns on.
b. DELETE IN (OUT) POINT
1) Press [DEL] key and [IN] ([OUT]) key
2) The [IN]([OUT]) point is cleared. The [IN]([OUT]) indicator is turned off.
c. MANUALLY ENTER IN (OUT) POINT
1) Press [SHIFT] and [IN]([OUT]) key.
2) The display prompts to enter new [IN] ([OUT]) point
3) Type in the new timecode using numeric keypad.
4) Press [ENTER] to save the new [IN]([OUT]) point.
OR
Press [ESC] to leave without saving
OR
Press [RECUE] to save the new [IN]([OUT]) point and recue to it.
d. CREATE SUBCLIP
1) Mark or Enter IN and OUT points as described above
2) Press [SHIFT] + [CLIP LIST] keys.
3) The display prompts to enter a subclip name.
4) Enter the name using the Shotbox keyboard or the numeric keypad
5) Press [ENTER].
6) The subclip with the specified name and the IN and OUT points is created.

16 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
13. RECUE THE CURRENTLY LOADED CLIP
a. Press [RECUE] to reload the currently loaded clip to the IN point.
b. Press [SHIFT] + [RECUE].
The display will show: “xx:xx:xx:xx”
(Where xx:xx:xx:xx = Last entered RECUE time.)
“Enter RECUE time”
Enter the time using the ST300’s numeric keypad.
Press [ENTER] to reload the currently loaded clip at the entered time.
OR
Press [ESC] to exit without searching.
14. VIEW THE CLIP ID OF THE CURRENTLY LOADED
CLIP
a. Press and hold [SHIFT], then press and release [LOAD].
b. The bottom line will show: “Loaded Clip: xxxxxxxx”
where xxxxxxxx is the CLIP ID.

17 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
15. VIEW CONTENT OF CUE POINTS ON THE
SHOTBOX
a. Press [VIEW]. The VIEW indicator comes on.
b. Press the switch for which you would like to see the content.
c. The switch turns RED and the content (CLIP ID) of the corresponding Cue Point is
displayed on a virtual display.
For Example:
Note: All the remaining switches are not illuminated.
d. Release the keys to return to normal operation.
16. SHOTBOX CONTROL SWITCHES
a. [PLAY]: Plays out the selected clip.
b. [RECUE]: Returns to the beginning of the clip.
c. [STOP]: Stops playout of the clip.
17. CLEAR SINGLE CUEPOINT
On the Shotbox, press [SHIFT] + the Shotkey, the content of which you wish to clear.
The Shotkey becomes blank, the corresponding cuepoint is cleared.
VTR 1
Clip 23 VTR 2
Clip 13 VTR 3
Clip 77 VTR 4
No Assignment

18 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
18. TRANSFERRING CUELISTS
The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a PC, using
the provided utility software on the PC, or to another ST300. Transfer to a PC requires OpSuite
3.0 software, which runs on a Windows-based computer. Contact DNF Controls for more
information.
a. TO TRANSMIT CUE POINTS TO THE ST300
1) Connect the VTR4 connector on the rear of the ST300 to the VTR4 connector of
the receiving ST300 using an RS422 9-pin cable with TX and RX lines crossed.
(A “turnaround” cable)
2) Press [MENU].
3) Scroll the Wheel until “Transmit CUE List? YES=Enter, Exit=ESC” is
displayed.
4) Press [ENTER] to start transmitting.
The Display shows “Waiting to transmit” on the first line.
5) When the Receiver is ready, transfer starts automatically.
The Display now shows “Transmitting cuelist.”
6) After the transfer is over, the display shows “Transfer is over” for one second
and then shows “Waiting to transmit” again.
7) Connect another ST300 to transmit the list again.
OR
Press [ESC] twice to exit the MENU mode.
b. TO TRANSMIT CUE POINTS TO THE PC
1) Connect the VTR4 connector on the back of the ST300 to one of the COM ports
on the PC using a RS422 to RS232 adapter.
2) Repeat steps 2-7 of the TO TRANSMIT CUE POINTS TO THE ST300
section.

19 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
19. RECEIVE CUELIST FUNCTION.
The RECEIVE CUELIST function allows you to receive your list of Cue Points from a PC or
from another ST300. Transfer to a PC requires OpSuite 3.0 software, which runs on a Windows-
based computer. Contact DNF Controls for more information.
a. TO RECEIVE CUE POINTS FROM THE ST300
1) Connect the VTR4 connector on the back of the ST300 from the VTR4
connector of the transmitting ST300 using RS422 9-pin cable with TX and RX
lines crossed.
(A “Turnaround” Cable)
2) Press [MENU].
3) Scroll the Wheel until “Receive CUE List? YES=Enter, Exit=ESC” is displayed.
4) Press [ENTER] to start receiving.
The Display shows “Waiting to receive” on the first line.
5) When the Transmitter is ready, transfer starts automatically.
The Display now shows “Receiving cuelist.”
6) After the transfer is over the display shows “Done-Success! Press any key…”
7) Press any key. The display shows “Receive cuelist?” message.
8) Press [ESC] to exit the MENU mode.
b. TO RECEIVE CUE POINTS FROM THE PC
1) Connect the VTR4 connector on the back of the ST300 to one of the COM ports
on the PC using RS422 to RS232 adapter.
2) Repeat steps 2-8 of the TO RECEIVE CUE POINTS FROM THE ST300
section.

20 2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
Reference . . .
20. SETUP MENU
Press [MENU]. The MENU indicator will turn on.
Turn the Wheel to select item to change.
Press [MENU] OR use the Softkeys to change the desired mode for that option.
Turn the Wheel at anytime to select another item.
Press [ESC] at anytime to exit. The MENU indicator will turn off.
MENU MODES
(Turning Wheel clockwise)
SET LOUTH
PORT
Allows user to select Louth Port for each VTR.
RECORD
Press [MENU] to select the desired record mode: Lockout or Crash (Full).
EXTENDED IDs
(V3.0 Only)
Toggle Extended IDs ON/OFF.
Extended IDs ON allows access up to 32 characters, OFF – up to 8 characters.
CLIP SOM Press displayed softkey to toggle between “ZERO” and “NOT ZERO.”
Select ZERO if the clips that you are using start with 00:00:00:00.
Select NOT ZERO if the clips that you are using do not start with 00:00:00:00.
RECALL MODE Press Normal or Redirect (Redir).
When one and only one clip is learned into a Cue Point, the Clip will be
REDIRECTED to load on the currently selected VTR if REDIR is on.
If REDIR is off, the Clip will be loaded on the VTR it is LEARNED into.
VIDEO STANDARD Press displayed softkey to select PAL, NTSC (not drop frame), or DF (drop
frame).
WIND MODE
Press Softkey to select:
HOLD
(Fast wind is maintained only while key is depressed.)
OR
LATCH
(Fast wind is initiated and maintained with momentary key press.)
Select fast wind speed (3.9 to 23.7) by pressing Softkey below SPD.
Table of contents
Other DNF Controls Control Unit manuals
Popular Control Unit manuals by other brands

Asus
Asus AAEON NIM-S26A Quick installation guide

Pulsar
Pulsar MSRK 3012 quick start guide

GE
GE Masoneilan 469 Series instruction manual

Burkert
Burkert 2000 INOX operating instructions

HomeMatic
HomeMatic CCU2 HM-Cen-O-TW-2 Series Installation and operating manual

Click Lighthouse
Click Lighthouse ClickSmart user manual