dol sensors iDOL 63 Manual

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com
EN–TECHNICALUSERGUIDE
INTRODUCTION
This manual covers the installation; mounting, electrical installation and setup of the iDOL 63 Cloud Gateway. The manual provides the user,
installer and electrician with the basic knowledge on how to mount and connect the iDOL 63 to the cloud.
The electrical installation section is intended primarily for electricians commissioning and servicing the system.
Please be aware that the iDOL 63 may not be opened without first removing the supply voltage, and
that service and troubleshooting may only be done by qualified personnel.
PRODUCT DESCRIPTION
The iDOL 63 Cloud Gateway collects data from the attached DOL sensors and sends these data to the DOL Omni Cloud.
The sensor data can be viewed in Omni Farm app.
SETUP
The full process for unboxing the iDOL 63 to fully operational is for short described by the following steps:
•Unbox and install the iDOL 63 as described in this manual. This includes mounting and electrical installation
•Install local network in the stable and connect into the Internet/WAN
•Use POE via the internet cable
Make sure to read the full guide before you start mounting the iDOL 63.
MOUNTING
The iDOL 63 must be mounted in the walking area or control room, not directly inside the stable area together with the animals.
Mount the sensors inside the stable area according to the installation instructions found in the sensor documentation.
iDOL 63 is delivered with a mounting bracket.
Mount the bracket onto the back of the box with the two 4x10 TX20 screws provided. Note
that the bracket should be mounted furthest away from the cable inlet holes in the bottom.
Figure 1: Mounting bracket
Mount iDOL 63 to the wall using suitable fasteners for the wall material.

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com
ELECTRICAL INSTALLATION
The electrical connections must be made as specified below.
Figure 2: Inside of the iDOL 63 box. Make sure that cables and wires are connected as illustrated
Internet
The box needs access to the internet via the ethernet port (RJ45 internet connector). The ethernet cable must not exceed 100m. The network must
provide a dynamic allocated IP for the iDOL 63.
The network (connection to internet) must allow for:
-TCP I/O access to port 8883 (secure MQTT)
-TCP I/O access to port 443 (secure HTTP)
-TCP/UDP I/O access to port 53 (DNS)
Power
The iDOL 63 is powered by POE via the RJ45 internet connector.
Figure 3: iDOL 63 powered with RJ45 internet connector

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com
Sensors
The sensors must be connected to the exact ports on the screw terminals as illustrated below. Max current per port is 83 mA.
Minimum cable size depends on the distance to the sensor, please refer to the table below:
Distance
mm2
AWG
<50 m
Min. 0.5 mm2
Min. 20 AWG
50-100 m
Min. 0.75 mm2
Min. 18 AWG
100-150 m
Min. 1.0 mm2
Min. 17 AWG
Front LED
On completion of mounting, installation and powering up, the tree LEDs on the front will indicate the status of the iDOL 63.
Power LED –Green, ON
iDOL 63 is powered
Status LED –Green, ON
iDOL 63 is connected to the internet
Status LED –Green, flashing
No connection to the internet
Status LED –Red, ON
Internal error
Status LED –Red, flashing
Inernal memory full
Figure 4: Label with MAC address can be found on the circuit board

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com
Farm
Stable
Section
Pen
MAC Address
Comment
Figure 5: Table for registration of location. Typically, the sensors are mounted at section level, then simply skip filling in the Pen
MAINTENANCE
The iDOL 63 iself do not need maintenance.
When clean iDOL 63, use water and a brush. Do not use:
•High-pressure cleaner
•Highly compressed air
•Solvents
•Corrosive/caustic agents
•Alcohol-based disinfectants
TROUBLESHOOTING
Please refer to section Front LED in this manual.
TECHNICAL DATA
Supply voltage
48VDC (PoE IEEE 802.3af or better)
Supply power available
12.95W minimum
Ambient temperature, operation
0°C –50°C
Ambient temperature, storage
-20°C –60°C
Ambient humidity, operation
10 - 90%RH
Classification
IP 54
Connection, Power
RJ45
LAN: CAT5e (or higher)
Connection, Sensors
Screw terminal
Weight
1000 g
Dimensions
H x W x D: 120 × 162 × 261 mm
Dimensions, shipment
H x W x D: 165 × 230 × 310 mm

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com

dol-sensors a/s Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959 www.dol-sensors.com

2020.09.02 • 604393 • 12.1 • EN • Made in Denmark