Dometic CoolAir SP950C User manual

CLIMATE CONTROL
COOLAIR
SP950C, SPX1200C
Compressor unit
Installation Manual . . . . . . . . . . . . . . . . . . 3
Kompressoreinheit
Montageanleitung . . . . . . . . . . . . . . . . . .14
Unité du compresseur
Instructions de montage. . . . . . . . . . . . . 24
Compresor
Instrucciones de montaje . . . . . . . . . . . . 34
Compressor
Instruções de montagem . . . . . . . . . . . . 44
Compressore
Indicazioni di montaggio . . . . . . . . . . . . 54
Compressoreenheid
Montagehandleiding . . . . . . . . . . . . . . . 64
Kompressorenhed
Monteringsvejledning . . . . . . . . . . . . . . 74
Kompressorenhet
Monteringsanvisning . . . . . . . . . . . . . . . 84
Kompressorenhet
Monteringsanvisning . . . . . . . . . . . . . . . 94
Kompressoriyksikkö
Asennusohje . . . . . . . . . . . . . . . . . . . . . . 104
Компрессорный модуль
Инструкция по монтажу . . . . . . . . . . . . 113
Jednostka kompresora
Instrukcja montażu . . . . . . . . . . . . . . . . . 124
Kompresorová jednotka
Návod na montáž . . . . . . . . . . . . . . . . . . 134
Kompresorová jednotka
Návod k montáži. . . . . . . . . . . . . . . . . . . 144
Kompresszor
Szerelési útmutató . . . . . . . . . . . . . . . . . 153
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 1 Donnerstag, 29. Juli 2021 4:35 16

© 2021 Dometic Group. The visual appearance of the contents of this manual is protected by
copyright and design law. The underlying technical design and the products contained herein may
be protected by design, patent or be patent pending. The trademarks mentioned in this manual
belong to Dometic Sweden AB. All rights are reserved.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 2 Donnerstag, 29. Juli 2021 4:35 16

3
EN
CoolAir SP950C/SPX1200C Explanation of symbols
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure that you install, use,
and maintain the product properly at all times. These instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and agree to abide by
the terms and conditions as set forth herein. You agree to usethis product only for the intended purpose and application andin accordance with the instructions,
guidelines, and warnings as set forth in this product manual as well as in accordance with all applicable laws and regulations. A failure to read and follow the
instructions and warnings set forth herein may result in an injury to yourself and others, damage to your product or damage to other property in the vicinity. This
product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date prod-
uct information, please visit documents.dometic.com, dometic.com.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Using the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Handling electrical cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Conventions in this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 General information on the installation manual . . . . . . . . . . . . . . . . . . . . . 5
3.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.1 Prescribed installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.3 Determining the installation position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.4 Installing the compressor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.5 Connecting the compressor unit to the evaporator unit . . . . . . . . . . . . . .11
7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1 Explanation of symbols
!
!
A
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided, could
result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 3 Donnerstag, 29. Juli 2021 4:35 16

EN
Safety instructions CoolAir SP950C/SPX1200C
4
I
2 Safety instructions
2.1 Using the device
• The freedom of movement of semi-trailers (of the outer edges of the semi-
trailer when turning or jackknifing) and other vehicle attachments must not be
restricted.
• Only use the air conditioning roof unit for the purpose specified by the
manufacturer and do not make any alterations or structural changes to the
device.
• Do not use the air conditioning roof unit if it is visibly damaged.
• The air conditioning roof unit must be installed safely so that it cannot tip over
or fall down.
• Installation, maintenance and repair work may only be carried out by
qualified personnel from a specialist company who are familiar with the risks
involved and the relevant regulations.
• Do not use the air conditioning roof unit near flammable fluids and gases.
• Do not operate the air conditioning roof unit if the ambient temperature is
below 0 °C.
• Do not undo the upper cover of the air conditioning roof unit in the event of
a fire. Use approved extinguishing agents instead. Do not use water to
extinguish fires.
• Disconnect all power supply lines when working on the air conditioning roof
unit (cleaning, maintenance, etc).
NOTE
Supplementary information for operating the product.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 4 Donnerstag, 29. Juli 2021 4:35 16

5
EN
CoolAir SP950C/SPX1200C Conventions in this manual
2.2 Handling electrical cables
• Use cable ducts to lay cables through walls with sharp edges.
• Do not lay loose or bent cables next to electrically conductive materials
(metal).
• Do not pull on the cables.
• Attach and lay the cables in such a manner that they cannot be tripped over
or damaged.
• The electrical power supply may only be connected by a specialist work-
shop.
• Fit a fuse of 25 amps to the connection to the vehicle's power supply.
• Never lay power supply lines (battery leads) in the vicinity of signal or control
cables.
3 Conventions in this manual
3.1 General information on the installation manual
This installation manual contains the essential information and instructions for
installing the parking cooler. The information is intended to be read by the
installation personnel of the parking cooler.
The following instructions are intended to help you use the installation manual
properly:
• The installation manual is part of the scope of delivery and should be stored
carefully.
• The installation manual provides you with important information on the
installation of the device and can also be used as a reference material in the
event of repairs.
• The manufacturer assumes no liability for non-observance of this installation
manual. Any claims are excluded in this case.
3.2 Target group
The installation and configuration information in this manual is intended for
qualified installation personnel who are familiar with the guidelines and safety
precautions to be applied during the installation of lorry accessory parts.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 5 Donnerstag, 29. Juli 2021 4:35 16

EN
Proper use CoolAir SP950C/SPX1200C
6
4Properuse
The CoolAir parking cooler is for supplying the cab of a lorry with cooled and
dehumidified air. It can be used while driving.
The CoolAir SP950C/SPX1200C compressor unit can only be operated in
combination with a CoolAir SP950T/SPX1200T roof evaporator unit or a
CoolAir SP950I/SPX1200IC rear panel evaporator unit. Both components
together form the CoolAir SP950/SPX1200 parking cooler.
A
I
The CoolAir is ready to install on delivery. The manufacturer strongly
recommends the use of a vehicle-specific fastening frame for an optimum
installation procedure for the compressor unit on the rear panel of the cab.
This product is only suitable for the intended purpose and application in accor-
dance with these instructions.
This manual provides information that is necessary for proper installation and/or
operation of the product. Poor installation and/or improper operating or main-
tenance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product
resulting from:
• Incorrect assembly or connection, including excess voltage
• Incorrect maintenance or use of spare parts other than original spare parts
provided by the manufacturer
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
NOTICE! Damage hazard
• The CoolAir parking cooler is not suitable for installation in agricultural
machines and construction machines or similar equipment. It does not
work properly in the event of strong vibrations and exposure to dust.
• Operating the parking cooler with voltages other than those specified can
result in damage to the device.
NOTE
The parking cooler is only designed for ambient temperatures of up to 43 °C in
cooling mode.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 6 Donnerstag, 29. Juli 2021 4:35 16

7
EN
CoolAir SP950C/SPX1200C Scope of delivery
5 Scope of delivery
6 Installation
A
6.1 Prescribed installation method
The compressor unit (fig. 11) is attached to the firm and straight rear panel of
the cab or by means of a firm fastening frame.
I
The parking cooler with rear panel evaporator unit consists of the following
components (fig. 1):
• CoolAir SP950C/SPX1200C compressor unit (1)
• CoolAir SP950I/SPX1200I rear panel evaporator unit (2) with connection
line (3)
The parking cooler with roof evaporator unit consists of the following
components (fig. 1):
• CoolAir SP950C/SPX1200C compressor unit (1)
• CoolAir SP950T/SPX1200T roof evaporator unit (4) with connection line (3)
Part designation Quantity
CoolAir compressor unit
SP950C
SPX1200C
1
Installation material 1
Installation manual 1
NOTICE! Damage hazard
The parking cooler may only be installed by qualified personnel from a
specialist company. The following information is intended for specialists who
are familiar with the guidelines and safety precautions to be applied.
NOTE
The connection line (fig. 13) can only be installed after fitting the evaporator
unit and the compressor unit.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 7 Donnerstag, 29. Juli 2021 4:35 16

EN
Installation CoolAir SP950C/SPX1200C
8
6.2 Notes on installation
!
!
A
I
You should always read this installation manual all the way through before
installing the parking cooler.
WARNING! Electrocution hazard
• Detach all connections to battery before starting installation of parking
cooler.
• Make sure that all electrical components are electrically discharged before
carrying out work on them!
CAUTION! Health hazard
Improper installation of the parking cooler can result in irreparable damage to
the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the parking cooler is not
installed according to this installation manual. That applies to malfunctions and
the safety of the air conditioning roof unit, in particular to injuries and damage
to property.
NOTICE! Damage hazard
The manufacturer only assumes liability for parts included in the scope of
delivery. The validity of the warranty expires if the system is installed together
with third-party parts.
NOTE
• The manufacturer strongly recommends the use of a vehicle-specific
fastening frame for an optimum installation procedure for the compressor
unit on the rear panel of the cab.
• After installing the unit, the specified parameters of the unit software must
be checked (refer to the installation instructions of the evaporator unit).
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 8 Donnerstag, 29. Juli 2021 4:35 16

9
EN
CoolAir SP950C/SPX1200C Installation
Youshould always observethe followingtips andinformation wheninstalling the
parking cooler:
• Please consult the manufacturer of your vehicle with regard to the following.
– is the cab's rear panel a suitable location for attaching the unit?
– is the body designed to bear the static weight and loads occasioned by
the parking cooler in a moving vehicle?
• Always check before installation of the unit whether any vehicle components
could be damaged, deformed or impaired in terms of their functionality as a
result of the installation.
• Avoid any unnecessary and frequent mechanical stress to the supply line
between the evaporator unit and the compressor unit. Damage can result in
the loss of refrigerant and impair the performance of the unit.
• The supplied assembly parts must not be modified during installation.
• The ventilation slots (grill) may not be covered (minimum distance from other
attachment parts: 10 cm).
• If a fastening frame is not used to install the system, make sure that the
installation position of the compressor unit on the rear panel is not too low.
The system could be damaged by high temperatures of the engine's waste
heat.
• The device shall be installed in accordance with national wiring regulations.
6.3 Determining the installation position
The installation position of the unit must meet the following criteria:
• All maintenance work must be easy to perform.
• Sufficient space must be available for the refrigerant line.
• The compressor unit must not be installed with a horizontal or vertical
inclination.
• The compressor unit must not be fitted near direct waste heat (engine heat
etc.).
• The refrigerant line must be long enough to connect the compressor and
evaporator units. The line must not be laid taut.
–SP950T/SPX1200T: approx. 4.2 m
–SP950I: approx. 2.3 m
–SPX1200IC: approx. 2.1 m
• The fastening surface should be as flat as possible. Use spacer sleeves for
uneven surfaces. If spacer sleeves are used, longer fastening screws with
sufficient tensile strength (not included in the assembly set) must be used.
• The freedom of movement of semi-trailers (of the outer edges of the semi-
trailer when turning or jackknifing) and other vehicle attachments must not be
restricted.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 9 Donnerstag, 29. Juli 2021 4:35 16

EN
Installation CoolAir SP950C/SPX1200C
10
6.4 Installing the compressor unit
A
I
Overview: fig. 2
➤Dismantle the outer housing.
SP950C: To do this, remove the four hexagon bolts on the fan (fig. 31)
and the eight hexagon socket head bolts (fig. 32).
When taking off the outer housing, release the plug connection of the fan
connection cable.
SPX1200C: To do this, remove the six torx screws (fig. 41).
➤Decide on the position of the compressor unit.
Use the fastening holes of the compressor unit as a template.
➤Use a felt pen to mark the positions selected for the holes.
➤Drill fastening holes (Ø 9 mm) at the marked positions.
I
➤Push the four M8 x 40 mm bolts (fig. 510) with the four washers outer
diameter Ø 40 mm (fig. 59) from the inside through the rear wall.
➤From the outside, push the four washers (fig. 58) on the protruding bolts.
➤Fasten the bolts and washers using the narrow M8 nuts (fig. 57).
➤Push the washers (fig. 66) on the protruding M8 bolts.
For rear walls with an offset, use the supplied spacer sleeves (fig. 65) to
compensate.
Adjust the length.
➤Put the compressor unit on the protruding M8 bolts.
➤Fasten with the M8 washers (fig. 64) and the M8 self-locking nuts
(fig. 63).
NOTICE! Damage hazard
Due to its weight, the compressor unit must have contact with at least two
fastening points of the fastening surface. Do not use spacer sleeves for all four
fastening points.
NOTE
To install the compressor unit using a vehicle-specific fastening frame, please
observe the instructions included in the frame's scope of delivery. The
following work steps describe the installation of the compressor unit without
vehicle-specific fastening frame.
NOTE
Apply anti-oxidant compound to all drilled through-holes to prevent rust
formation.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 10 Donnerstag, 29. Juli 2021 4:35 16

11
EN
CoolAir SP950C/SPX1200C Installation
I
6.5 Connecting the compressor unit to the evaporator
unit
A
➤Install the connection line for the compressor unit and insert it in the
compressor unit.
I
➤Connect the rear coupling halves (thick refrigerant line) (fig. 7) with each
other and tighten them hand-tight ¼ revolution with an open-ended
spanner.
➤Connect the front coupling halves (thin refrigerant line) (fig. 8) with each
other and tighten them hand-tight ¼ revolution with an open-ended
spanner.
➤SP950C only: Install the protective cover underneath the coupling and
secure it with the lid supplied.
➤SP950C only: Fasten the thick refrigerant line with the supplied pipe clip,
the M6 x 16 mm hexagon head bolt, the M6 washer and the M6 self-locking
nuts (fig. 9).
➤SPX1200C only: Assemble the refrigerant line as shown (fig. 0).
NOTE
The panelling can only be fitted once the refrigerant lines and the cables
(chapter “Connecting the compressor unit to the evaporator unit” on page 11)
have been connected.
NOTICE! Damage hazard
Before fastening the connection couplings, make sure that the sealing and
thread faces are absolutely clean. Any contamination will result in a malfunction
of the air conditioner.
NOTE
Make sure that the coupling half with the thin capillary tube is not twisted or
kinked.
When tightening the coupling halves, it is essential that you use a second open-
ended spanner to hold the other part.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 11 Donnerstag, 29. Juli 2021 4:35 16

EN
Installation CoolAir SP950C/SPX1200C
12
Observe the following instructions when installing the supply lines:
• Also observe the installation instructions for the evaporator unit.
• The maximum cable length between the evaporator and compressor unit is:
–SP950T/SPX1200T: approx. 4.2 m
–SP950I: approx. 2.3 m
–SPX1200IC: approx. 2.1 m
• Avoid any narrow radii when routing and bending supply lines. Use a suitable
round object with a shim as a bending aid. A radius which is too narrow will
kink the refrigerant line, and this will prevent the auxiliary air conditioning unit
from operating.
➤Shorten any supply line which is not needed by bending a curve.
➤SP950C only: Insert the plug of the cable (power cable) into the mating
plug of the compressor unit (fig. a).
➤SPX1200C only: Assemble the connection cable and corrugated piping as
shown (fig. 0and fig. b).
➤SP950C only: Insert the plug connection of the fan cable back together.
➤Place the outer housing onto the compressor unit.
➤SP950C only: Fasten the outer housing with the eight hexagon socket
screws (fig. c2).
➤SP950C only: Fasten the fan with the four hexagon bolts (fig. c1).
➤SPX1200C only: Fasten the outer housing with the six torx screws (fig. 0).
➤Apply sealant (fig. e1) to prevent any water from getting between the rear
wall of the truck and the clip.
I
➤Use the supplied holders to fasten the connection line to the rear panel of the
truck (fig. e).
➤Insert corrugated piping in the holder provided (fig. e2).
➤Put on the lid (fig. e4).
NOTE
If you want to avoid damaging the rear wall of the truck (drilling a hole), you can
also apply the clip using a suitable adhesive.
Observe the instructions provided by the adhesive manufacturer.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 12 Donnerstag, 29. Juli 2021 4:35 16

13
EN
CoolAir SP950C/SPX1200C Disposal
7Disposal
➤Place the packaging material in the appropriate recycling waste bins,
wherever possible.
MIf you wish to finally dispose of the product, ask your local recycling center or
specialist dealer for details about how to do this in accordance with the appli-
cable disposal regulations.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 13 Donnerstag, 29. Juli 2021 4:35 16

DE
Erläuterung der Symbole CoolAir SP950C/SPX1200C
14
Lesen und befolgen Sie bitte alle Anweisungen, Richtlinien und Warnhinweise in diesem Produkthandbuch sorgfältig, um sicherzustellen, dass Sie das Produkt
ordnungsgemäß installieren und stets ordnungsgemäß betreiben und warten. Diese Anleitung MUSS bei dem Produkt verbleiben.
Durch die Verwendung des Produktes bestätigen Sie hiermit, dass Sie alle Anweisungen, Richtlinien und Warnhinweise sorgfältig gelesen haben und dass Sie
die hierin dargelegten Bestimmungen verstanden haben und ihnen zustimmen. Sie erklären sich damit einverstanden, dieses Produkt nur für den angegebenen
Verwendungszweck und gemäß den Anweisungen, Richtlinien und Warnhinweisen dieses Produkthandbuchs sowie gemäß allen geltenden Gesetzen und Vor-
schriften zu verwenden. Eine Nichtbeachtung der hierin enthaltenen Anweisungen und Warnhinweise kann zu einer Verletzung Ihrer selbst und anderer Perso-
nen, zu Schäden an Ihrem Produkt oder zu Schäden an anderem Eigentum in der Umgebung führen. Dieses Produkthandbuch, einschließlich der Anweisungen,
Richtlinien und Warnhinweise, sowie die zugehörige Dokumentation können Änderungen und Aktualisierungen unterliegen. Aktuelle Produktinformationen fin-
den Sie unter documents.dometic.com, dometic.com.
Inhalt
1 Erläuterung der Symbole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Verwendung des Geräts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
2.2 Umgang mit elektrischen Leitungen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3 Konventionen in dieser Anleitung . . . . . . . . . . . . . . . . . . . . . . . . 16
3.1 Allgemeine Informationen zur Montageanleitung . . . . . . . . . . . . . . . . . .16
3.2 Zielgruppe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4 Bestimmungsgemäßer Gebrauch. . . . . . . . . . . . . . . . . . . . . . . . . 16
5 Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.1 Vorgeschriebenes Montageverfahren. . . . . . . . . . . . . . . . . . . . . . . . . . . .18
6.2 Hinweise zur Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
6.3 Einbaulage bestimmen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.4 Kompressoreinheit montieren . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.5 Kompressoreinheit an die Verdampfereinheit anschließen . . . . . . . . . . 22
7 Entsorgung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1 Erläuterung der Symbole
!
!
A
WARNUNG!
Sicherheitshinweis auf eine Gefahrensituation, die zum Tod oder zu
schwerer Verletzung führen kann, wenn sie nicht vermieden wird.
VORSICHT!
Sicherheitshinweis auf eine Gefahrensituation, die zu einer leichten oder
mittelschweren Verletzung führen kann, wenn sie nicht vermieden wird.
ACHTUNG!
Hinweis auf eine Situation, die zu Sachschäden führen kann, wenn sie nicht
vermieden wird.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 14 Donnerstag, 29. Juli 2021 4:35 16

15
DE
CoolAir SP950C/SPX1200C Sicherheitshinweise
I
2 Sicherheitshinweise
2.1 Verwendung des Geräts
• Die Bewegungsfreiheit von Aufliegern (die äußeren Kanten des Aufliegers
beim Einlenken oder Einknicken) und anderen Fahrzeuganbauten darf nicht
eingeschränkt werden.
• Benutzen Sie die Dachklimaanlage nur für den vom Hersteller angegebenen
Verwendungszweck und führen Sie keine Änderungen oder Umbauten am
Gerät durch.
• Wenn die Dachklimaanlage sichtbare Beschädigungen aufweist, darf Sie
nicht in Betrieb genommen werden.
• Die Dachklimaanlage muss so sicher montiert werden, dass sie nicht umstür-
zen oder herabfallen kann.
• Die Installation, Wartung und etwaige Reparatur dürfen nur durch einen
Fachbetrieb erfolgen, der mit den damit verbundenen Gefahren bzw. ein-
schlägigen Vorschriften vertraut ist!
• Setzen Sie die Dachklimaanlage nicht in der Nähe von entflammbaren Flüs-
sigkeiten und Gasen ein.
• Betreiben Sie die Dachklimaanlage nicht bei Außentemperaturen unter 0 °C.
• Im Falle von Feuer lösen Sie nicht den oberen Deckel der Dachklimaanlage.
Verwenden Sie stattdessen zugelassene Löschmittel. Verwenden Sie kein
Wasser zum Löschen.
• Lösen Sie bei Arbeiten (Reinigung, Wartung usw.) an der Dachklimaanlage
alle Verbindungen zur Stromversorgung.
2.2 Umgang mit elektrischen Leitungen
• Müssen Leitungen durch scharfkantige Wände geführt werden, so verwen-
den Sie Leerrohre bzw. Leitungsdurchführungen.
• Verlegen Sie keine losen oder scharf abgeknickten Leitungen an elektrisch
leitenden Materialien (Metall).
• Ziehen Sie nicht an den Leitungen.
• Befestigen und verlegen Sie Leitungen so, dass keine Stolpergefahr entsteht
und eine Beschädigung des Kabels ausgeschlossen ist.
HINWEIS
Ergänzende Informationen zur Bedienung des Produktes.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 15 Donnerstag, 29. Juli 2021 4:35 16

DE
Konventionen in dieser Anleitung CoolAir SP950C/SPX1200C
16
• Der elektrische Anschluss darf nur von einem Fachbetrieb durchgeführt wer-
den.
• Sichern Sie den Anschluss an das Fahrzeugnetz mit 25 A ab.
• Verlegen Sie niemals die Spannungsversorgungsleitungen (Batteriekabel) in
räumlicher Nähe zu Signal- oder Steuerleitungen.
3 Konventionen in dieser Anleitung
3.1 Allgemeine Informationen zur Montageanleitung
Diese Montageanleitung enthält die wesentlichen Informationen und Anleitun-
gen für die Montage der Standklimaanlage. Die enthaltenen Informationen rich-
ten sich an den Montagebetrieb der Standklimaanlage.
Folgende Hinweise helfen Ihnen bei der korrekten Anwendung der
Montageanleitung:
• Die Montageanleitung ist Teil des Lieferumfangs und ist sorgfältig aufzube-
wahren.
• Die Montageanleitung gibt Ihnen wichtige Hinweise für die Montage und
dient gleichzeitig in Reparaturfällen als Nachschlagewerk.
• Bei Nichtbeachtung dieser Montageanleitung haftet der Hersteller nicht.
Jegliche Ansprüche sind für diesen Fall ausgeschlossen.
3.2 Zielgruppe
Installations- und Konfigurationsinformationen in dieser Anleitung richten sich an
Facharbeiter in Installationsbetrieben die mit den anzuwendenden Richtlinien
und Sicherheitsvorkehrungen beim Einbau von Lkw-Zubehörteilen vertraut sind.
4 Bestimmungsgemäßer Gebrauch
Die CoolAir Standklimaanlage dient dazu, das Fahrerhaus eines Lkw mit gekühl-
ter und entfeuchteter Luft zu klimatisieren. Der Einsatz während der Fahrt ist
möglich.
Die Kompressoreinheit CoolAir SP950C/SPX1200C ist nur in Verbindung mit
einer Dachverdampfereinheit CoolAir SP950T/SPX1200T oder einer Rück-
wandverdampfereinheit CoolAir SP950I/SPX1200IC funktionsfähig. Beide
Komponenten zusammen bilden die Standklimaanlage CoolAir SP950/
SPX1200.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 16 Donnerstag, 29. Juli 2021 4:35 16

17
DE
CoolAir SP950C/SPX1200C Bestimmungsgemäßer Gebrauch
A
I
Die CoolAir Standklimaanlage wird Ihnen in einem montagefähigen Zustand
geliefert. Der Hersteller empfiehlt ausdrücklich die Verwendung eines fahr-
zeugspezifischen Befestigungsrahmens zur optimalen Montage der Kompresso-
reinheit an die Fahrerhausrückwand.
Dieses Produkt ist nur für den angegebenen Verwendungszweck und die
Anwendung gemäß dieser Anleitung geeignet.
Dieses Handbuch enthält Informationen, die für die ordnungsgemäße Installa-
tion und den ordnungsgemäßen Betrieb des Produkts erforderlich sind. Installa-
tionsfehler und/oder ein nicht ordnungsgemäßer Betrieb oder nicht
ordnungsgemäße Wartung haben eine unzureichende Leistung und u. U. einen
Ausfall des Geräts zur Folge.
Der Hersteller übernimmt keine Haftung für Verletzungen oder Schäden am Pro-
dukt, die durch Folgendes entstehen:
• Unsachgemäße Montage oder falscher Anschluss, einschließlich Überspan-
nung
• Unsachgemäße Wartung oder Verwendung von anderen als den vom Her-
steller gelieferten Original-Ersatzteilen
• Veränderungen am Produkt ohne ausdrückliche Genehmigung des Herstel-
lers
• Verwendung für andere als die in der Anleitung beschriebenen Zwecke
Dometic behält sich das Recht vor, das Erscheinungsbild des Produkts und des-
sen technische Daten zu ändern.
ACHTUNG! Beschädigungsgefahr
• Die CoolAir Standklimaanlage ist nicht für die Montage in Land- und Bau-
maschinen oder ähnlichen Arbeitsgeräten geeignet. Bei zu starker Vibra-
tions- und Staubeinwirkung ist eine ordnungsgemäße Funktion nicht
gewährleistet.
• Der Betrieb der Standklimaanlage mit Spannungswerten, die von den
angegebenen Werten abweichen, führt zur Beschädigung des Gerätes.
HINWEIS
Die Standklimaanlage ist für eine Umgebungstemperatur nicht über 43 °C im
Kühlbetrieb ausgelegt.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 17 Donnerstag, 29. Juli 2021 4:35 16

DE
Lieferumfang CoolAir SP950C/SPX1200C
18
5 Lieferumfang
6 Installation
A
6.1 Vorgeschriebenes Montageverfahren
Die Kompressoreinheit (Abb. 11) wird an der stabilen und geraden Fahrer-
hausrückwand oder unter Verwendung eines stabilen Befestigungsrahmens
angebracht.
I
Die Standklimaanlage mit Rückwandverdampfereinheit besteht aus den folgen-
den Komponenten (Abb. 1):
• Kompressoreinheit CoolAir SP950C/SPX1200C (1)
• Rückwandverdampfereinheit CoolAir SP950I/SPX1200I (2) mit Verbin-
dungsleitung (3)
Die Standklimaanlage mit Dachverdampfereinheit besteht aus den folgenden
Komponenten (Abb. 1):
• Kompressoreinheit CoolAir SP950C/SPX1200C (1)
• Dachverdampfereinheit CoolAir SP950T/SPX1200T (4) mit Verbindungs-
leitung (3)
Teilebezeichnung Anzahl
CoolAir Kompressoreinheit
SP950C
SPX1200C
1
Montagematerial 1
Montageanleitung 1
ACHTUNG! Beschädigungsgefahr
Die Montage der Standklimaanlage darf ausschließlich von entsprechend aus-
gebildeten Fachbetrieben durchgeführt werden. Die nachfolgenden Informa-
tionen richten sich an Fachkräfte die mit den anzuwendenen Richtlinien und
Sicherheitsvorkehrungen vertraut sind.
HINWEIS
Die Verbindungsleitung (Abb. 13) kann erst nach Montage der Verdampfer-
einheit und der Kompressoreinheit montiert werden.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 18 Donnerstag, 29. Juli 2021 4:35 16

19
DE
CoolAir SP950C/SPX1200C Installation
6.2 Hinweise zur Installation
!
!
A
I
Lesen Sie unbedingt vor der Montage der Standklimaanlage diese Montage-
anleitung vollständig durch.
Beachten Sie unbedingt folgende Tipps und Hinweise bei der Montage der
Standklimaanlage:
• Informieren Sie sich bei Ihrem Fahrzeughersteller:
– Ist die Fahrerhausrückwand für das Anbringen der Anlage geeignet?
– Ist der Aufbau für das statische Gewicht und die Belastungen durch die
Standklimaanlage bei sich bewegendem Fahrzeug ausgelegt?
• Prüfen Sie vor der Installation der Anlage, ob durch den Einbau Fahrzeug-
komponenten beschädigt, verformt oder in ihrer Funktion beeinträchtigt
werden könnten.
• Vermeiden Sie unnötige und häufige mechanische Beanspruchungen der
Versorgungsleitung zwischen Verdampfer- und Kompressoreinheit. Beschä-
digungen können zu Kältemittelverlust und zu einer Beeinträchtigung der
Anlagenleistung führen.
WARNUNG! Gefahr durch Stromschlag
• Lösen Sie vor Beginn der Montage der Standklimaanlage alle Verbindun-
gen zur Batterie.
• Stellen Sie vor Arbeiten an elektrisch betriebenen Komponenten sicher,
dass keine Spannung mehr anliegt!
VORSICHT! Gesundheitsgefahr
Eine falsche Montage der Standklimaanlage kann zu irreparablen Schäden am
Gerät führen und die Sicherheit des Benutzers beeinträchtigen.
Wenn die Standklimaanlage nicht gemäß dieser Montageanleitung montiert
wird, übernimmt der Hersteller keinerlei Haftung. Nicht für Betriebsstörungen
und für die Sicherheit der Standklimaanlage, insbesondere nicht für Personen-
und/oder Sachschäden.
ACHTUNG! Beschädigungsgefahr
Der Hersteller übernimmt ausschließlich Haftung für im Lieferumfang enthal-
tene Teile. Beim Einbau der Anlage zusammen mit produktfremden Teilen ent-
fällt die Gewährleistungsgarantie.
HINWEIS
• Der Hersteller empfiehlt ausdrücklich die Verwendung eines fahrzeug-
spezifischen Befestigungsrahmens zur optimalen Montage der
Kompressoreinheit an die Fahrerhausrückwand.
• Nach der Installation der Anlage müssen die vorgegebenen Parameter der
Anlagen-Software überprüft werden (siehe Installationsanleitung der zuge-
hörigen Verdampfereinheit).
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 19 Donnerstag, 29. Juli 2021 4:35 16

DE
Installation CoolAir SP950C/SPX1200C
20
• Die mitgelieferten Montageteile dürfen bei der Montage nicht eigenmächtig
modifiziert werden.
• Die Lüftungsöffnungen (Gitter) dürfen nicht abgedeckt werden (Mindestab-
stand zu anderen Anbauteilen: 10 cm).
• Wird die Anlage nicht mit einem Befestigungsrahmen eingebaut, so achten
Sie darauf, dass die Einbaulage der Kompressoreinheit nicht zu tief an der
Rückwand gewählt wird. Durch die hohen Temperaturen der Motorab-
wärme kann die Anlage beschädigt werden.
• Die Montage des Geräts muss in Übereinstimmung mit nationalen Bestim-
mungen erfolgen.
6.3 Einbaulage bestimmen
Die Einbaulage der Einheit muss folgende Kriterien erfüllen:
• Wartungsarbeiten müssen leicht durchgeführt werden können.
• Für die Kältemittelleitung muss genügend Platz vorhanden sein.
• Die Kompressoreinheit darf nicht in Horizontal- und Vertikalrichtung geneigt
eingebaut werden.
• Die Kompressoreinheit darf nicht im Bereich von direkter Abwärme (Motor-
wärme usw.) montiert werden.
• Die Kältemittelleitung muss lang genug sein, um den Kompressor und die
Verdampfereinheiten zu verbinden. Die Leitung darf nicht auf Spannung ver-
legt werden.
–SP950T/SPX1200T: ca. 4,2 m
–SP950I: ca. 2,3 m
–SPX1200IC: ca. 2,1 m
• Die Befestigungsfläche sollte möglichst eben sein. Bei unebenen Flächen
müssen Distanzhülsen verwendet werden. Bei Verwendung von Distanzhül-
sen müssen entsprechend längere Befestigung-schrauben mit ausreichen-
der Zugfestigkeit (nicht im Montagesatz vorhanden) verwandt werden.
• Die Bewegungsfreiheit von Aufliegern (die äußeren Kanten des Aufliegers
beim Einlenken oder Einknicken) und anderen Fahrzeuganbauten darf nicht
eingeschränkt werden.
6.4 Kompressoreinheit montieren
AACHTUNG! Beschädigungsgefahr
Aufgrund des Gewichts muss die Kompressoreinheit an mindestens zwei
Befestigungspunkten der Befestigungsfläche anliegen. Verwenden Sie nicht
an allen vier Befestigungspunkten Distanzhülsen.
DometicSP950C-SPX1200C-Uni_INM_4445102819_EMEA16_202x-xx-xx.book Seite 20 Donnerstag, 29. Juli 2021 4:35 16
Other manuals for CoolAir SP950C
9
This manual suits for next models
1
Table of contents
Languages:
Other Dometic Air Compressor manuals
Popular Air Compressor manuals by other brands

Lavor
Lavor ENDURO 145 COMPRESSOR manual

Stanley
Stanley HY 227/10/5 Instruction manual for owner's use

Mattei
Mattei AC 6000 Series Instruction, use and maintenance manual

Raider
Raider RD-AC08 user manual

Craftsman
Craftsman 921.164780 owner's manual

Coltri Compressors
Coltri Compressors MCH-8/EM STANDARD Use and maintenance manual