Doorentryonline K301A User manual

VANDAL RESISTANT
BACK-LIT WEATHERPROOF
ACCESS CONTROL KEYPAD
K301A
User Manual (MK-II)
FOR ELECTRIC LOCK, INTER-LOCK
AND SECURITY SYSTEM INSTALLATIONS
Doorentryonline Ltd

TABLE OF CONTENTS
INTRODUCTION
FEATURES
OPTIONAL DEVICES FOR SYSTEM EXPANSION
SPECIFICATIONS
INSTALLATION
Precautions
CONNECTION TERMINALS
OTHER FACILITIES
On-Board LED Indicators
Pacifier Tone & The LED Signals
Jumper for Back-Lit Selection
PREPARATION FOR PROGRAMMING
A) Criteria for Codes
B) Security Level of The Operation Media
PROGRAMMING AND OPERATION
Power Up The Keypad
Set Keypad into Programming Mode with Master Code
Direct Access to Programming Mode with The “DAP” Code – 2 8 2 8
System Refreshing with “Refreshing Code” --- 9 9 9 9
The Default Values after Refreshing
Master Code
Super User Code
Operation and Functions of The Super User Code
User Codes For Output 1 & 2
Examples – Programming And Operation
Visitor Codes (For Output 1 Only)
Duress Codes (For Outputs 1 & 2 )
Operation And Function of The Duress Code
Output Modes & Timing for Output 1 and 2
System Real-Time-Clock
Start & Stop Times For Daily Inhibition of Output 1
Personal Safety And System Lock-Out
User Code Entry Mode - Auto or Manual
Pacifier Tones On-Off Selection
Output Operation Announcer
Status LED Flashing On-Off during Standby
Door Forced Open Warning & Timing
Door Propped-Up Warning & The Delay Time
Intelligent Egress Button – An Unique Feature of A Contemporary Keypad
Where And Why “Going Out” Needs Attention
Egress Delay , Warning And Alarm
························································································································· 5
·································································································································· 5
····································································· 5
······················································································································· 6
··························································································································· 7
································································································································ 7
·································································································· 8-10
··················································································································· 11
·········································································································· 11
······························································································· 11
···································································································· 11
······················································································ 12
················································································································· 12
················································································· 12
····················································································· 13-42
·············································································································· 13
···························································· 13
··········································· 14
······························································ 14
·························································································· 15
····························································································································· 16
······················································································································· 16
··························································· 17-18
···································································································· 19
············································································ 20-21
······················································································ 22-23
····················································································· 24-25
········································································ 25
·············································································· 26
············································································································ 27
····························································· 28-29
······················································································ 30
··················································································· 31
································································································· 31
··································································································· 32
·············································································· 32
······················································································· 33
············································································33
·······························34
······························································· 34-35
······················································································ 36-37
Doorentryonline Ltd

TABLE OF CONTENTS
Operation Modes
Close The Programming Mode
Programming - General Users
Programming Summary Chart
Application Examples
Stand alone Door Lock
Inter Lock System Using Two Keypads
························································································································· 38
···································································································· 38
39
····························································································· 40-41
·········································································································· 42-43
············································································································· 42
···················································································· 43
·······································································································
Doorentryonline Ltd

INTRODUCTION
FEATURES
K301A is a self-contained two output relay, vandal resistant and weatherproof keypad. It has been
designed for full feature stand alone access control applications
The keypad is ideally for door strike and alarm arm-disarm controls. It is also a programmable
industrial timer (from 1 second to over 24 hours) for automatic operator system.
K301A (Standard Version):
Output Relay 1 – 5A Rating N.C. & N.O. Contacts for Door Lock Actuation Control
Output Relay 2 – 1A Rating N.C. & N.O. Contacts for Auxiliary Device Control
A member of the Tri-Tech series keypads compatible with the optional controllers & reader keypads
for system expansion
Loaded with the K301A MK-II operation software
Built-in with all the logics for stand alone, split-decoded and multi-station operations
Controls “Going in” with User Codes and “Going out” with feature programmable egress button
Independent control for the two output relays with programming timer
Total 1,100 User Codes for controlling of the two outputs
Indoor or outdoor installation with IP-66 all weather ingress protection
Stainless steel faceplate combines with die-casting metal back-lit key buttons
Vandal resistant die-casting metal housing for surface or gooseneck mounting
Package Contents
• One K301A Keypad
• One Pack of Mounting Screws
• One Centre Pin Torx Screw Wrench
• One User Manual
5
Doorentryonline Ltd

SPECIFICATIONS
6
Operating Voltage:
12V-24V AC/DC, Auto adjusting
Operating Current:
20mA (quiescent) to 90mA@12VDC
10mA (quiescent) to 45mA@24VDC
Storage and Operation Temperature:
-20 C to +70 C
Storage and Operation Humidity:
5-95% relative humidity non-condensing
Working Environment & Ingress Protection:
All weather, IP-66
Number of Users:
Output 1 – 1,000 (User Codes) + 50 Duress Codes
Output 2 – 100 (User Codes) + 10 Duress Codes
Number of Visitor Codes:
50, programmable for one time or with time limit
Timings for Code Entry:
10 seconds waiting for next digit entry
The Timers:
1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1 & 2
Egress Button:
Programmable for Instant, Delay with Warning
Momentary or Holding Contact for Exit Delay
Input Sensing Terminals:
a) Door position, b) Egress, c) O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a) Duress, b) Key Active, c) Inter-lock
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
125(H) X 79(W) X 46/54(D)mm
Weight:
510g net
Housing:
Die-Cast Aluminum, Powder-paint coating
Faceplate Material:
1.5mm stainless steel
Doorentryonline Ltd

INSTALLATION
ASSEMBLY
Do not apply power to the system while it is in installation.
Check carefully all the wirings are correct before applying power to the system for testing.
In previous experience, most of the damages caused in the installation are accidental touching of the
components on circuit board with the wires carrying power. Please be patient to study the manual to
become familiar with the specifications of the system before starting the installations.
7
PRECAUTIONS
Doorentryonline Ltd

CONNECTION TERMINALS
1 - 2 : 12 - 24V AC/DC (Power Input Terminal)
Connect to 12-24V AC or DC power supply. The (-) supply and (-) GND (terminals 2
& 12) are the common grounding points of the keypad system. No selection jumper
is required for the full input voltage range. Connect DC power with the (+) and (-)
polarity indicated; and there is no polarity discrimination for AC power input.
3 - 4 - 5 : OUTPUT 1 (Output Relay 1)
5 Amp relay dry contact controlled by the Group 1 User Codes, recommended for
door strike. Terminal 3 is Normally Closed (N.C.), terminal 5 is Normally Open (N.O.)
and terminal 4 is the common point of the two contacts. Use N.C. output for Fail-safe
locking device; and N.O. output for Fail-secure locking device. The relay is
programmable for Start/Stop (toggle) mode or Momentary timing mode. See
programming Location 51 for the details.
6 - 7 - 8: OUTPUT 2 (Output Relay 2)
1 Amp relay dry contact with N.C. and N.O. outputs. Terminal 6 is the N.C.(Normally
Closed). terminal 8 is N.O. (Normally Open) and terminal 7 is the common point of
the two contacts, which is prepared for actuating auxiliary device controlled by the
keypad; or external door chime actuation controlled by the bell button. The
maximum rating of the relay contacts is 24 VDC/1A.
K301A - Standard Version
The Output relay 2 in K301A is controlled by the Group 2 User Codes. It is
programmable for Start/Stop (toggle) mode or Momentary Timer mode. See
programming Location 52 for the details.
8
BACK-LIT JUMPER
CONNECTION
TERMINALS
Doorentryonline Ltd

9: EG IN ( Egress Input)
A Normally Open (N.O.) input terminal referring to (-) ground. With the help of connecting a normally
open button to activate Output 1 for door opening like using Codes.
Egress button is usually put inside the house near the door. More than one egress buttons can be
connected in parallel to this terminal. Leave this terminal open if not used.
See Programming Locations 90 for more information about the Egress Button with programmable
features.
10: KEY ACT O/P (Keypad Active Output)
An NPN transistor open collector output with maximum power rating of 24VDC/100mA sink. It is
equivalent to an N.O. (Normally Open) terminal referring to ground. It can be used to drive small
power device, such as a relay or a low power control point for other equipment.
11: DU OUT (Duress Output)
An NPN transistor open collector output with maximum power rating of 24VDC/100mA sink. It is
equivalent to an N.O. (Normally Open) terminal switching to (-) ground after the Duress Code is
entered. Use it to trigger an alarm zone of a security system, or turn on a buzzer to notify a guard.
12: (-) GND (Common Ground)
A grounding point of the keypad that is common to terminal 2.
13: DOOR SENS N.C. (Door Position Sensing Input -- Normally Close)
A Normally Closed (N.C.) sensing point referring to (-) ground, with the help of a normally closed
magnetic contact monitors the open or close status of the door. It initiates the following functions for
the system. Connect it with jumper to (-) Ground if not used.
a) Door Auto Re-lock
The system immediately re-locks the door after it is re-closed before the end of the programmed time
for output 1. It prevents unwanted “tailgate” entry.
b) Door Forced Open Warning
The keypad generates “door forced open” warning instantly once the door is forced to open without
a valid user Code or egress button. The warning lasts as long as the time programmed (1-999 sec).
It can be stopped with an User Code for output 1 at anytime. See programming Location 80 for the
details.
c) Door Propped-up Warning
The keypad generates propped-up warning beeps while the door is left open longer than the
allowable time programmed. The warning will last as long as the door is open until re-closed. See
programming Location 81 for the details.
d) Inter-lock Control
The inter-lock control output always goes to (-) while the door is open, which gives signal to disable
the partner keypad in an inter-lock system. See the Inter-lock terminal 15 description for more
information.
9
Doorentryonline Ltd

14: O/P 1 INHIBIT N.O. (Output 1 Inhibit Control Input – Normally Open)
A Normally Open (N.O.) sensing input point for controlling the Output 1, with this terminal connecting
to (-) ground, the Egress Button, the group of User PINs for Output 1 are all disabled.It is
prepared mainly for the cross wire connection with the “Inter-lock O/P” point of the partner keypad in
an Inter-lock system.
NOTE: The inhibit function does not govern the Duress Codes and the Super User Codes. They are
always valid
15: INTER-LOCK O/P (Inter-lock Control Output)
An NPN transistor open collector output with maximum power rating of 24VDC/100mA sink. It is OFF
at normal condition and it switches to (-) ground immediately for the first 5 seconds after keying in a
valid User Code to operate Output 1, then, it will keep tying to (-) ground during the Door Position
Sensor is open circuit due to door opening. Use this output point to make cross wire connection with
the partner keypad’s “O/P 1 Inhibit” point in an Inter-lock system to prevent both doors can be opened
at the same time.
An Inter-lock System:
An inter-lock system is a two-door system that always allows only one of the doors to open during the
operation. While one of the doors is opened, the other door keeps close until the open door is re-closed.
It prevents the unauthorized people dashing into a protected area while the doors are in use.
An inter-lock system needs two keypads and two door position sensing switches for the two doors.
16 - 17: TAMPER N.C. (Tamper Switch Normally Closed Contact)
A normally closed dry contact while the keypad is secured on its box. It is open while keypad is
separated from the box. Connect this N.C. terminal to the 24 hour protection zone of an alarm system
if necessary.
18: DATA I/O PORT (Data Communication Bus)
Data I/O port is prepared for setting up a data bus for the connection of the auxiliary reader-keypads
and the split-decoder in system expansion. See the examples in “Application Expansions” section for the
details.
10
Doorentryonline Ltd

ON-BOARD LED INDICATORS
RED / GREEN (Right) ---
AMBER (Centre) ---------
RED (Left) ----------
PACIFIER TONES & THE LED SIGNALS
The buzzer and the amber LED indicator give following tones and signals respectively for system
status:
It lights up in Green for Output 1 activation; Red for Output 1 inhibited
and flashing during inhibition paused.
It flashes in Standby. It shows the system status in synchronization
with the beep tones. The standby flashing can be OFF with
programming. See Location 73 for the details.
It lights up in Red for output 2 activation.
STATUS TONES * AMBER LED
1) In Programming Mode ----- ON
2) Successful Key Entry 1 Beep 1 Flash
3) Successful Code Entry 2 Beeps 2 Flashes
4) Unsuccessful Code Entry 5 Beeps 5 Flashes
5) Power Up Delay Continuous Beeps Continuous Flashes
6) Output Relay Activation ** 1 Second Long Beep
7) In Standby *** ----- 1 Flash in 1 Second Interval
8) System Refreshing
9) Code Already Stored in System
----- Fast Flashes for 2.5 Minutes
1 Long Beep
-----
-----
Continuous 3 Fast Beeps
/5 secs -----
Continuous 1 Beep/5 secs
11) Real -time-clock stopped after
power failure
10) Keypad link-up with Decoder Failed -----
NOTE:
*
* *
* * *
JUMPER FOR BACK-LIT SELECTION
1) Full Back-lit ---
2) Auto Back-lit ---
3) OFF ---
All Pacifier Tones can be ON or OFF through the programming option at Location 71
The Output Relay Activation beep can be selected through the programming option at
Location 72
The Standby flashing can be ON or OFF through the programming option at Location 73
The keypad gives dim backlit in standby. It
turns to full backlit when a key button is
pressed, then back to dim backlit 10
seconds after the last key button is
pressed.
The backlit is OFF in standby. It turns to
full backlit when a key button is pressed,
then back to OFF 10 seconds after the last
key button is pressed.
Back-lit function disabled.
11
OTHER FACILITIES
BACK-LIT
JUMPER
·······································································································
Doorentryonline Ltd

ON-BOARD LED INDICATORS
RED / GREEN (Right) ---
AMBER (Centre) ---------
RED (Left) ----------
PACIFIER TONES & THE LED SIGNALS
The buzzer and the amber LED indicator give following tones and signals respectively for system
status:
NOTE:
*
* *
* * *
JUMPER FOR BACK-LIT SELECTION
1) Full Back-lit ---
2) Auto Back-lit ---
3) OFF ---
12
PREPARATION FOR PROGRAMMING
A) CRITERIA FOR CODES
Prime Codes
a) User Codes
b) Master Code
c) Super User Code
d) Visitor Codes
All these codes MUST be unique. It is not allowed to repeat a prime code for second function.
All the codes in this system can be 4-8 digits for Manual Entry Mode. The codes must be in the same
digit length with the Master Codes for Auto Entry Mode. See Location 70 for the details.
NOTE:
The keypad will reject repeated use of prime code in programming and give one long beep
indication.
Example:
User
13579
24680
1234
3456
Output 1
Output 1
Output 1
Output 1
004
003
002
001
10
10
10
10
Tracy
5678 Output 200120Bill
Tom
May
John
Name Location User ID Code Remark
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
--
1,000
B) LIST OF USER INFORMATION
The keypad can accommodate up to 1,000 users for door control and 100 users for auxiliary control.
To avoid confusion and for programming convenience, it is suggested to make a list recording of the
user information. It helps the owner to program the user codes smoothly and to trace them
afterwards in the future. Here is a suggested format of the list.
List of Users (See page 19-21 for reference)
Doorentryonline Ltd

13
SET KEYPAD IN PROGRAMMING MODE WITH MASTER CODE
It is always necessary to set the keypad in programming mode for feature programming
The keypad is in normal operation after power-up delay. Set it in programming mode with Master
Code and validate it with
MASTER CODE VALIDATION
NOTE:
a) For the owner’s convenience in programming at the first time, a Master Code 0 0 0 0 has been
put into the keypad before exit-factory. It is NOT a default code. For security reason, owner
should program a personal Master Code to replace it after the keypad is owned.
b) The Mains LED (amber) is ON after the keypad confirms it in programming mode with 2 beeps.
d) DO NOT turn off power while the keypad is in programming mode. Otherwise, it may cause error
to the data in memory.
PROGRAMMING & OPERATION
POWER-UP THE KEYPAD
The keypad gives power-up delay of 1 minute after power has been applied. It is the time frame
designed for setting the keypad to programming mode with DAP code. See the details of “DAP
CODE – 2 8 2 8” below.
1) The keypad gives continuous beeps for 1 minute after power-up.
2) The power-up delay can be stopped instantly with if the delay beep is found annoying
and setting the keypad to programming mode with DAP code is not required.
3) The keypad will set itself to Normal Operation Mode automatically after the 1 minute power-up
delay expired or it is stopped with .
12 #
POWER-UP DELAY STOP VALIDATION
12#
12#
Doorentryonline Ltd

14
5) To program a new Master Code to replace the old one. See “Record A Master Code”stated at
“Location 01” for the details.
NOTE:
The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is
not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat
procedures 1-4.
SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9
The keypad can be refreshed by cleaning all the programmed old data and set it back to default
values except the Master Code.
REFRESHING CODE VALIDATION
NOTE:
a)
b)
c)
Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are
necessary.
DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad
into programming mode with DAP code:
1)
2)
3)
4)
Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives
continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP
code.
Press the Egress Button (the button connecting accross EG IN, (Terminal 9) and (-)GND,
(Terminal 15) once to enable the keypad for accepting DAP code. The power-up beep stops after
the Egress Button is pressed.
Key in the DAP code and validate it with (or ). The Status LED is
ON and the keypad is in programming mode like using Master Code. It is ready to accept new
programming data as long as you like until exit programming mode.
..
PRESS ONCE
EGRESS BUTTON DAP CODE VALIDATION
Doorentryonline Ltd

15
LOCATION PARAMETERS DEFAULT FUNCTIONS & VALUES
0 1 Master Code 0 0 0 0 Factory Set, Not a default value *
0 4 Common User Code 2 Nil ----- User Program Required
1 0 User Codes for O/P 1 Nil ----- User Program Required
2 0 User Codes for O/P 2 Nil ----- User Program Required
4 0 Visitor Codes Nil ----- User Program Required
4 1 Duress Code for O/P 1 Nil ----- User Program Required
4 2 Duress Code for O/P 2 Nil ----- User Program Required
5 1 O/P Mode of The O/P 1 Time = 5 Sec, Momentary
5 2 O/P Mode of The O/P 2 Time = 5 Sec, Momentary
5 6 Start & Stop Time Nil ----- User Program Required
5 5 System Real-Time-Clock Nil ----- User Program Required
9 4 Operation Modes Code = 0,Keypad Mode
6 0 Personal Safety & Lock-out Code = 1, 10 False Code Lock-out 60 Sec
7 0 User Code Entry Mode Code = 2, Manual Entry Mode
7 1
7 2 O/P Operation Announcer
7 3 Status LED Standby Flashing ON-
OFF
Code = 1, Flashing Enabled
8 0 Door Forced Open Warning & Timing Code = 0, Warning Disabled
8 1 Door Propped-up Warning & Delay Code = 0, Warning Disabled
9 0 Egress Delay & Warning Code 1 = 0, Instant, No Delay
Code 2 = 1, Momentary Contact without Warning
Code = 1, Pacifier Tone ON
Code = 1 Sec, Notification Beep ON
Pacifier Tones ON-OFF Selection
THE DEFAULT VALUES AFTER REFRESHING
NOTE:
The DAP Code 2 8 2 8 and the Refreshing Code 9 9 9 9 are fixed in the operating system program.
It can not be changed in any ways.
Doorentryonline Ltd

16
4 to 8 Digits
01 #
MASTER CODE (Location 01)
LOCATION MASTER CODE VALIDATION
(1) LOCATION
Key in Location
(2) MASTER CODE
(3) VALIDATION
Master Code is the authorization code for setting the system to programming mode. It is NOT
an User Code operating the output relays.
The Master Code can be 4 to 8 digits.
When a new master code is keyed in and confirmed, the old master code is replaced.
The master code is also the Link-up Code between the keypad and the optional decoder in
Split-decoded operation.
(2)(1) (3)
Press key once. Two-beeps confirms the entry.
Example:
Set a Master Code “2 2 3 3” ----
01
SUPER USER CODE (Location 02)
The Super User Code has TWO functions. It is prepared to operate the three outputs and make
operation of inhibit enable / disable to those outputs.
(1) LOCATION
Key in Location
(2) SUPER USER CODE
The Super User Code can be 4 to 8 digits.
When a new Super User Code is keyed in and confirmed, the old one is replaced.
(3) VALIDATION
Pressing key to confirm code entry.
#
Example:
a) Set a Super User Code “2 5 8 0” ----
b) Deleted a Super User Code from memory: Key in the Location number and #. ----
4 to 8 Digits
02 #
(1) (2) (3)
LOCATION SUPER USER CODE VALIDATION
02
Doorentryonline Ltd

OPERATION AND FUNCTIONS OF THE SUPER USER CODE
1) Operate Output 1 and 2
The operation of the Super User Code is just like a normal User Code. Simply key-in the Code
with a specific output number for the desired Output. The Super User Code can also be used to
reset an operating output timer instantly.
---------- Output 1 Activates or Resets
---------- Output 2 Activates or Resets
Optional Functions Controlled by Super User Code for Output 1
Apart from controlling of the two outputs 1 and 2; the Super User Code can also be used to
enable the optional functions controlling Output 1 for user convenience or security enhancement.
Super User Code and Egress Button are excluded from any system inhibition and lockup
functions; they are valid for door open at anytime for safety.
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked
for a period of time to allow door opening without User Code for entry / exit convenience. This
function Starts / Stops in toggle with the following code entry.
---------- The Door is Un-locked, Start / Stop in Toggle
NOTE :
3) Pause The Scheduled Daily Inhibition for Output 1 (Temporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop
times. It can be stopped temporarily if required; such as the staff work overtime after office
hours going into the inhibition period. This function Starts / Stops in toggle with the following
code entry. It can be done before or during the inhibition period.
---------- Door Lock Operation Resumes, Start / Stop in Toggle
NOTE :
• The “INHIBIT” LED (Red) is ON in inhibition and turns to Flashing while pause is into effect.
• See Programming Locations 55 & 56 for more information Daily Inhibition.
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
The door is un-locked while the function is enabled. The “Output 1” LED (Green) turns ON.
Do not forget to stop this function after use because the door is un-locked. Also, the system
refuses the optional functions (3) & (4) while Override function comes into effect.
This feature is good for all the “Fail-safe electric locks”.
“Fail-secure electric lock” requires power to keep in un-locked condition. It takes high current all the
time while the function comes into effect and may cause damage to it. This function is not
recommended for Fail-secure electric lock.
17
Doorentryonline Ltd

18
4) Inhibit All The User Codes for Output 1 (Disable Access Control Manually)
To enhance the security of the access control keypad, the owner can stop the keypad after office hour
or while the house is nobody inside. Once the Output 1 (for door lock control) is inhibited, all the User
Codes for it become invalid and those people holding the User Code are refused. This function Starts
/ Stops in toggle with the following code entry.
------ Door Lock Operation Inhibited, Start / Stop in Toggle
NOTE :
• The door is locked during Output 1 inhibited and the “INHIBIT” LED (Red) is ON.
• Inhibition applies to all User Codes for Output 1 only. Output 2 is not affected.
SUPER USER CODE
Doorentryonline Ltd

19
USER CODES FOR OUTPUT 1 & 2 (Locations 10 & 20)
LOCATIONS MEDIA USER ID USER CODE VALIDATION
(1) LOCATIONS (User Groups)
10 – Group 1 – 1,000 User Codes for controlling Output 1
20 – Group 2 – 100 User Codes for controlling Output 2
(2) MEDIA (Operation Media)
2– User Codes – 4-8 Digits
5– Delete User Codes from the selected User ID – Delete a user code by keying in
its ID.
0999 – Group Clearing. Clear all the User Codes of the selected User Group Location.
Clearing takes few seconds to a minute.
(3) USER ID (The IDs of The User Codes)
000 – 999 – 1,000 User IDs for the User Codes in User Group 1 (Output 1)
001 – 100 – 100 User IDs for the User Codes in User Group 2 (Output 2)
(4) USER CODE
Key in User Code into each assigned User ID.
(5) VALIDATION
Press the key once. Two-beep confirms the entry.
OR
(1) (2) (5)(4)(3)
Doorentryonline Ltd

20
(a) (b) (c) (d) (e)
EXAMPLES –PROGRAMMING AND OPERATION
1) Example 1 -- User Code for Output 1 :
i) Programming :
(a) The User Code is programmed for Output 1
(b) Record a User Code
(c) Take ID number 001 in Group 1 to store the User Code, which is one of the IDs in 000-999
(d) Key in the User Code "2 4 6 8" into the storage location
(e) Press # to store the “User Code” into memory, two-beep confirms a valid entry
ii) Operation : (while the system is back to operation mode)
(a) Key in the User Code “2 4 6 8”
(b) Confirm it with the # key. Output 1 activates
2) Example 2 -- User Code for Output 2 :
i) Programming :
(a) The User Code is programmed for Output 2
(b) Record a User Code
(c) Take ID number 001 in Group 2 to store the User Code, which is one of the IDs in 001-100
(d) Key in User Code “1 2 3 4” into the storage location
(e) Press # to confirm and store the “User Code” into memory, two-beep confirms a valid entry
ii)Operation : (while the system is back to operation mode)
(a) Key in the Private User Code “1 2 3 4”
(b) Confirm it with the # key. Output 2 activates
(a) (b) (c) (d) (e)
(a) (b)
(a) (b)
Doorentryonline Ltd

21
3) Example 3 -- Delete a User Code (for O/P 1, 2) :
i) Delete A User Code
(a) (b) (c) (d)
a) Key in the User Group that the User ID belongs to. “10” for the Group 1, “20” for the Group 2
b) Key in “5” that is the Command Code for making a deletion here
c) Key in the User ID that stored the User Code
d) Press the # key. Two-beep confirms a valid entry and the User Code in that User ID is cleared
4) Example 4 – Clear The Whole Group of Users :
Whole group of users can be cleared with the following command.
(a) (b) (c)
a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2
b) Key in the Group Deletion Command, 0 9 9 9
c) Confirm the deletion with #. All the User Codes in the Group 1 are cleared. It takes a few
seconds to a minute to complete depending on the data stored.
User ID
Doorentryonline Ltd