Pegasus PP-6750V Series Quick start guide

1
Intelligent Time Attendance Recorder & Access Controller
Access Control/Time & Attendance / Lift Access Control System/ Security
PP-6750V Series
Operational Manual
Ver.15.1
1508
W-04-6750V/E

2
Table of contents
S
y
stem Introduction 1
General Features 1
S
p
ecification 3
LCD instruction 4
Panel Descri
p
tion 6
Bottom View 6
Wirin
g
Connectors and PIN assi
g
nment 7
Exam
p
le of Wirin
g
8
Controller and Rela
y
Box Wirin
g
Exam
p
le 10
Macro instruction 13
Brief s
y
stem
p
ro
g
rammin
g
15
Chan
g
e the master PIN 15
Function code instruction 15
F0: Delete all
p
ersonal ma
p
15
F1:Access b
y
ke
y
in user ID throu
g
h master PIN 15
F2:Set weekda
y,
hour
,
minute 16
F3:Calendar
y
ear
,
month and date settin
g
16
F4: Parameters & Modes 16
Grou
p
0.S
y
stem Initiation 30
Grou
p
1.In
p
ut Commands 31
Grou
p
2.Out
p
ut Commands 31
Grou
p
3.O
p
eration Modes 32
Grou
p
4.Pin Or Master Pin Settin
g
33
Grou
p
5.In
q
uir
y
Mode 33
Grou
p
6.Time Zone Mode/Add Card Mode 33
Grou
p
7.Delete Card Mode 33
Grou
p
8.S
y
stem Confi
g
urations 34

3
Group 9. Factory Configuration 35
F5 : In
q
uir
y
mode 17
A. Sin
g
le card in
q
uir
y
17
B. Inquiry with learning mode 17
C. In
q
ui
r
y
card status b
y
block mode 17
F6:Add
p
ersonal ma
p
18
A. Add card no. 18
B. Add card no. and PIN 18
C-1. Add card with learnin
g
mode 19
C-2. Learnin
g
mode from
g
rou
p
nn 19
D. Add card with block mode 19
F7: Delete
p
ersonal ma
p
20
A. Delete single card 20
B. Delete card with leanin
g
mode 20
C. Delete card with block mode: 20
D. Delete card with block mode 20
F8: Time zone/holida
y
/bell
p
ro
g
rammin
g
21
A. Personalized mode 21
A-1. Time Zone Mode/Add Card Mode 22
A-2. Grou
p
with floor settin
g
23
A-3. Personalized time zone in
q
uir
y
23
A-4. Delete time zone 23
B. Free access mode 24
B-1. Auto dut
y
mode 24
B-2. Auto mode 26
C. Holida
y
mode 27
C-1. Holida
y
in
q
uir
y
27
D. Bell alarm mode 28

4
D-1. Bell alarm in
q
uir
y
mode 28
F9: Modif
y
events counter for event retrievin
g
29
F*: In
q
uir
y
and dis
p
la
y
the stored events 29
Sim
p
le and eas
y
trouble shootin
g
37
A
pp
endix 40

5
Packing List
Before getting start, please check the 6750V package contains the
following items:
DESCRIPTION Q’TY
The system unit 1 unit
1 9 Pin connector (Blue) 1 pc
2 8 Pin connector (White) 1 pc
3 4 Pin connector (White) 1 pc
4 3 Pin connector (White) 1 pc
5 Screw 1 pc
6 Free wheeling diode 1 pc
7 Sealing rubber for
waterproof 1 pc

1
6750V is an intelligent time recording terminal designed to meet the
variant applications in time attendance and access control, lift control
& ARM/DISARM security requirements.Each terminal can be operated
independently or through PC/Internet adapter PC-T100 to fulfill the multiple
terminal system. The recording terminal includes nearly all the necessary
functions for time recording and access control.Users can use master PIN to
select the desired functions from the abundant functional list (For malfunction,
please contact with your local distributors)
The system could be started by modifying the factory defaulted templated as
by code F4 + 0850 and then save them by 0650 to back up for farther
configuration your system by 0950, if you confused your configuration.
General Features
1-A Time recording features:
1、High capacity with 8 digits card number / 6 digits staff number and 8
character English name.( Either checking or without checking personal
map )
2、16 characters x2 rows of LCD disply with 8 digits which have
year, month,day,week,time, IP,operation mode,real time mode,unlock
time, door monitoring.
3、79 duty codes, duty name defined by PC.
4、Selectable batch or real time on-line mode.
5、Key in 8 digits ID for time attendance recording.
6、Totally 192 alarm schedules (8 schedules per hour) dry contacts output
for periodic bell announce.
There are 6 versions available:
(1)K Version: 1,000 card capacity, 500 events.
(2)L Version: 2,000 card capacity, 1,000 events.
(3)M Version: 30,000 card capacity, 10,000 events.
(4)N Version: 11,000 card capacity, 32,000 events.
(5)P Version: 11,000 card capacity, 8,000 events.
(6)X Version: 32,000 card capacity, 32,000 events.
Versions could be getting thru the equipped RS-485 interface.
System introduction

2
1-B. Access control features: (Main application)
1. System parameters and personal access map can be down loaded by PC
or manually programmed through keypad.
2. The personal access map is consisted of card ID, staff number and staff
name, PIN and Time Zone Status, expiry date and
Anti-passback.Operation modes : (1) card only (2) card + PIN (3)Door
PIN only and duress feature (4)Card no +PIN and duress feature(5)Free
access (6) Automatic operation mode by time zones
NOTE: The staff name is used under F4=9601, 3400 cards capacity only.
3. Individual personal access map can be added/deleted and checked by
on-lined PC or through manually in single / block range card number or
by direct reading card in learning mode.
4. Selectable immediate or batched serial output for event printing
5. With complete door release, status monitoring and intruded alarm
periord & error trials.

3
Dimensions :137mm(L) x 85mm(W) x 29mm(H)
Weight :340g± 5%
Power supply :DC 12V±10%, 80mA~100mA(not include power
requirement for lock & alarm)
Transmission rate :Default 9,600 bps N,8,1(2,400bps/4,800bps)
(19,200bps/38,400bps<selectable>)
Operating temperature :-20 ~ 70℃℃
Operating humidity :10%~90%
Keypad :3 x 4 keypad for system programming,
pass word entry or duty code selection.
Password :Programmable 4 digits PIN for each person
Serial interface :RS-485/RS-232(Optional)
Serial output
:1. For connection with serial printer.
*2. To drive DDR (digital door relay) for safety
control model.
3. Lifts controller. common door codes
Events/card capacity
:(1) K Version: 1,000 card capacity, 500 events.
(2) L Version: 2,000 card capacity, 1,000 events.
(3) M Version: 30,000 card capacity, 10,000 events.
(4) N Version: 11,000 card capacity, 32,000 events.
(5) P Version: 11,000 card capacity, 8,000 events.
(6) X Series: 32,000 card capacity, 32,000 events.
Other capacity combination requested by order
Card standard
:125KHz ASK EM / 125KHz FSK HID / 13.56MHz
Mifare (ISO 14443A , ISO 14443B, ISO 15693) /
13.56MHz Felica (ISO 18092 UID) / Q type / NFC /
Bluetooth
※Support customized card.
External Reader With one or optional two port for external Wiegand (26/34
bits definable by command) &
ABA input(by order)
Mifare® is a registered trademark of Philips Electronics N.V.
FeliCa is a trademark of Sony Corporation.
HID is a registered trademark of HID Global Corp.
Specification

4
Normal Display: After plug-in power, LCD displays as below:
Y Y / M M / D D
hh:m m XXX. +NNNNN
Y Y/ M M / D D: The calendar year, month and date (Year/ Month/ Day)
h h:mm:System clock, Hour & Minute (hh=00~23;mm=00~59)
X X X:weekday Monday to Sunday
NNNNN:The transaction records stored in the buffer.
When display shows “FULL”, which means the butter is full. Please download the
records by PC or press Master PIN and then press”9”,key-in “000000” to erase the
events.
Parameter display: key-in “9”, LCD displays as below:
Aaa Wt tt 96
AD R . W A T . D O R . BPS
Aaa : Polling address by F4=88aa (00~99)
WAT :Real time on-line waiting time by F4=890t (0~9), “0” for
baten mode by F4=99nn
DOR :Door released time by F4=21tt(00~99)
BPS :Buad Rate 96=9600 48=4800 24=2400 19=19200
N Wt tt N-N
REP . M O T . D P T . T - A
REP:Door Monitoring Status time for check repeat reads in unit of
second
N=t Check repeating card with t minutes
N=0 Norepeatingcardcheck
MOT: Door monitoring time by code F4=230t
LCD instruction
First display Parameter value
Parameter name
Second display Parameter value
Parameter name

5
DPT : LCD message display time by F4=250t, useful for F*
T-A :Time zone control – Free access mode
Y - Enable function
N -Disable function
*Note: The system could be operated in proper order only when the address
code is correctly programmed through 88nn. If the reader address is
not correctly programmed, the display of address will show some
other ASCII characters as “xxx“ above the ADR.which can’t save the
event; therefore you should program again.
Third display
R.rrrrr: The read counter of buffer
W.wwwww: The write counter of buffer
Version:CPU version
Note: Accoring to actual version.
R.r r r r r W.w w w w w
Version P 695 NI

6
Bottom View
Panel Description

7
Wiring Connectors and PIN assignment
A. J2-9P
Blue (For power input and access functions)
*Note:
Please connect the blue wire to GND if the Door Monitoring function is
unnecessary.
Please connect the purple wire to GND if the Security Sensor function is
unnecessary.

8
Example of how to wiring

9

10
※R-27-YK10T1/125/250V is line filter to avoid signal interference.
If elevator controller※doesn’t work; please turn off “Bypass switch”
of non-controlled button.
To connect 2 or 3 of 24 floor controllers to achevie 64 floors access※
of set up.
※Please refere appendix for floor controller of relate operation manner.

11
2750/3750/85/6750V PG-OUTMOD-8 Relay Box
9 Pin Blue Connector J5-7PinBlueConnector
Color Signal Name Color SignalName
No1.Red +12V No1.Red +12V
No2.Black GND No2.Black GND
No3.Brown No3.Orange No Connection
No4.Orange No4.Purple Serial Printer Input
No5.Yellow No5.Black No Connection
No6.Green No6.Gray No Connection
No7.Blue No7.Gray NoConnection
No8.Purple
No9.Gray Serial Printer Output
2750/3750/85/6750V PG-OUTMOD-24A Relay Box
9 Pin Blue Connector J5-9 Pin Blue Connector
Color SignalName Color SignalName
No1.Red +12V No1.Red +12V
No2.Black GND No2.Black GND
No3.Brown No3.Brown NoConnection
No4.Orange No4.Orange Serial Printer Input
No5.Yellow No5.Yellow No Connection
No6.Green No6.Gree No Connection
No7.Blue No7. Blue No. Connection
No8.Purple No.8Purple
No9.GraySerialPrinterOutput No.9Gray
System Initialize (default password 246890)
Please set the F4 = 0016 / F4 = 0018 / F4 = 0019 / F4 = 0 072 to prevent the
time zone data occupy memory and further caused the card number can not be
enrolled.
The system initialization means the system parameters are defaulted by
F4=0850(off-line mode) or F4=0750(on-line mode). Then the user could
modify some parameters based on it. After each modification to individual
requirement, the user may backup them by code F4=0650. Once the
parameters are destroyed, the code F4=0950 could be applied to restore it.
Controller and Relay Box Wiring Example

12
All the function code under F4 is disabled, except the timer for 21tt, 22…..
1. Door monitoring::Disable the door monitor function ( F4=1100 )
2. Presonal map compare:Not compare ( F4=1500 )
3. Door release time :close one second(F4=2101)
4. Door open mode:card only mode(F4=3200)
5. Anti-pass back mode : Disable (F4=3900)
6. Check repeat card : Disable(F4=8300)
7. Printer output function:Disable ( F4=8600 )
8. When event buffer full:Not recycle ( F4=8700 )
9. Computer connect mode:real time mode ( F4=8903 )-F4=0750
batch mode ( F4=8900 )-F4=0850
10. Card display format:Comparing card number 5th, 6th, 7th digits
( F4=9704 )
Operating instruction
The manager could program the controller by pressing “0” and master PIN
(default password as “246890”.The password could be modified by F4=4609)
to enter into the PROGRAM mode.
Summary of fuctions code please refer to ndex on the system introduction.
F0
【0】: Delete all personal map
F1
【1】: Key in user ID for access by master PIN
F2
【2】: Set weekday, hour, minute
F3【3】: Program Calendar year, month and date
F4【4】:
Parameter modes & Modes
F5【5】: Inquiry Personal access map
F6【6】: Add personal map
F7【7】: Delete personal map
F8【8】: Time zone/holiday/bell programming & Inquiry
F9【9】: Modify events counter for event retrieving
F10【*】:Display or print out recorded
Note:The programming procedures could be escaped by pressing ”#” by key.

13
MacroInstruction
For “Access Control”macro instruction※
F4=0851 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0851] For PN/Q/M8/M1 format
Parameter mode:
F4=9996
F4=9803
F4=2106
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 26 bits card number.
:Door release time: 6 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=1101
F4=3402
F4=9705
:The shortest time of display.
:Enable the door monitoring.
:Enable door PIN mode.
:Compare card number by
6th , 7th , 8th digits.
F4=0852 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0852] For M0 format
Parameter mode:
F4=9996
F4=9808
F4=2106
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 34 bits card number.
:Door release time: 6 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=1101
F4=3402
F4=9704
:The shortest time of display.
:Enable the door monitoring.
:Enable door PIN mode.
:Compare card number by
5th , 6th , 7th digits.
※For “Lift Control” macro instruction
F4=0853 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0853] For PN/Q/M8/M1format
Parameter mode:
F4=9996
F4=9803
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 26 bits card number.
:Door release time: 8 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8610
F4=1100
F4=9705
:The shortest time of display.
:Enable lift control 8 floor.
:Disable the door monitoring.
:Compare card number by
6th ,7th , 8th digits.
F4=0854 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0854] For M0 format
Parameter mode:
F4=9996
F4=9808
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 34its card number.
:Door release time: 8sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8610
F4=1100
F4=9704
:The shortest time of display.
:Enable lift control 8 floor.
:Disable the door monitoring.
:Compare card number by 5th
6
th, 7th digits.

14
F4=0855 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0855] For PN/Q/M8/M1format
Parameter mode:
F4=9996
F4=9803
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 26 bits card number.
:Door release time: 8 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8623
F4=1100
F4=9705
:The shortest time of display.
:Enable lift control 24 floor.
:Disable the door monitoring.
:Compare card number by
6th, 7th , 8th digits.
F4=0856 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0856] For M0 format
Parameter mode:
F4=9996
F4=9808
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 34 bits card number.
:Door release time: 8 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8623
F4=1100
F4=9704
:The shortest time of display.
:Enable lift control 24 floor.
:Disable the door monitoring.
:Compare card number by
5th, 6th, 7th digits.
F4=0857 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0857] For PN/Q/M8/M1format
Parameter mode:
F4=9996
F4=9803
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 26 bits card number.
:Door release time: 8 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8633
F4=1100
F4=9705
:The shortest time of display.
:Enable lift control 48 floor.
:Disable the door monitoring.
:Compare card number by
6th, 7th, 8th digits.
F4=0858 Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0858] For M0 format
Parameter mode:
F4=9996
F4=9808
F4=2108
F4=1501
F4=8700
:Baud rate:9600
:Wiegand 34 bits card number.
:Door release time: 8 sec.
:Enable comparing card number.
:For F1F0 mode.
F4=2500
F4=8633
F4=1100
F4=9704
:The shortest time of display.
:Enable lift control 48 floor.
:Disable the door monitoring.
:Compare card number by
5th, 6th, 7th digits.

15
Brief system programming
Change the master PIN
Ex.Change the master PIN to 654321,than F4+4609+654321. The new
master PIN would be changed to 654321
Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*-->Enter into
programming mode
Press[4] *FUNC-->-------- Parameter mode (F4)
Press[4609] +new master
PIN[KKKKKK]
MST.PIN- KKKKKK > KKKKKK would be the
Password
Function code instruction
F0: Delete all personal map
Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*--> Enter into
programming mode
Press[0] *CLRALL>-------- Delete mode(F0)
Press [0000] END--- INSTRUCTION
Repeat the last step or press [#] to escape from the programming.
F1: Direct keying master PIN
Ex. : Administrator puts in 8 codes ID of user with the personal password for
a user when someone forgets bring his card
※The personal password is set up by F4=3300(read a card with password
model) + F6(setting personal password). Above setting can be done on the
controller or computer.
Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*--> Enter into
programming mode
Press[1] *ID No.>-------- Access mode(F1)
Press card number [12345678] *PIN--->Put in the legal card
numbers
Press personal password [9999] Put in the personal
password
Table of contents
Other Pegasus IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Alarm Lock
Alarm Lock PDL3000 series Programming instructions

Software House
Software House iSTAR Pro 2U RM Quick start installation guide

ND
ND IP 39-60 ePCR Quick installation guide

Aiphone
Aiphone AC-10S Installation & operation manual

Comunello Automation
Comunello Automation MAST SLIM Installation and user manual

FingerTec
FingerTec TA700W quick start guide