Honeywell VISTA CA-FP-100F User manual

Fingerprint T&A
Access Control System
CA-FP-100F
CA-FP-100FS
User Guide
Version
:
::
:
1.0
Date
:
::
:
Feb, 2012
© 2012 Honeywell International Inc. All rights reserved.

Content Introduced
Content Introduced
This document describes Honeywell VISTA Serials Access
Control System installation user guide & wiring instruction.
About this Guide
The Honeywell VISTA Serials Access Control System
User guide is designed to provide information to install
the CA-FP-100F & CA-FP-100FS serial Access Control
System, for operation and configuration, please refer to
the corresponding user’s manual.
Not all function these guides introduce available in
combination, all is option.
About your machine function, please consult our
company technical personnel or the sales personnel.
☆
Information in this document is subject to change without notice.

Content Introduced
Contents
1 Before Installing.......................................................................... 1
1.1 Notice about installing...................................................... 1
2 System Configuration................................................................. 4
2.1 The illustration of system construction ............................ 4
2.2 The sketch map of communication.................................. 5
3.Installation .................................................................................. 6
3.1 Fixing mounting plate....................................................... 6
3.2 Connect with peripheral equipment ................................. 7
3.2.1 Door Sensor........................................................... 9
3.2.2 Release Button ...................................................... 9
3.2.3 Alarm...................................................................... 9
3.2.4 Conntion with lock ............................................... 10
3.2.5 Ethernet connection............................................. 16
3.2.6 Connection with RS232....................................... 18
3.2.7 Connection with RS485....................................... 19
3.2.8 Wiegand output.................................................... 21
3.2.9 Power connection ................................................ 22
3.2.10 Connect with external Wiegand reader ............. 22
3.3 Fixing Access Control System ....................................... 23
4. Fastening Access Control System .......................................... 24
5. Others...................................................................................... 25
5.1 Reset.............................................................................. 25
5.2 Anti-dismantle button ..................................................... 25
5.3 Cable doorbell................................................................ 26

Fingerprint T&A Access Control System User Guide
- -1
1 Before Installing
1.1 Notice about installing
Access Control System is a mass-produced product. It strictly
tested comply with the standard of China, U.S.A, and EU. This
file contains important information. It is better for you to read it
carefully prior to use. If you ignore it, the incorrect installation may
cause the unit damage. Although we could do our best to offer
you service, the neglect to the file could cause unwanted cost for
you.
1. Before installation, please make sure the power is cut off,
because it is very dangerous if the power is on. The short circuit of
power cable may cause the core parts damage.
2. All exposed part of connection wire end cannot be exceeded
5mm to prevent the bared wire accidental connection which leads
to machine break down. And also suggest using different color
cable to connect.
3. In the place where the static is strong or in winter, please
connect the grounding firstly, in order to prevent the instant mass
static damage the machine.
4. Connect power supply with device in the last for the wiring
connection. If you find any unusual thing occur, please firstly cut
off the power, then go to examine. Keep in mind: wiring operation

Fingerprint T&A Access Control System User Guide
- -2
under power on will lead to machine sudden damage; we are not
liable for damages and trouble due to such operation.
5. The height to mount device is about 1.4-1.5 meter
6. After installation, please take off protection film on the fingerprint
sensor to get best recognize result.
7. After installation finish, when go to test the exit-door button,
please keep a personal in the outside, because sometimes the
accidental issue can bring on you are not able to go outside.
8. Our equipment offer an automatically function, please after the
installing finish. Run the auto-test function to confirm the installation
finish.
9.We recommend using above the 12V/3A direct-current supply
for Honeywell VISTA series access control device, electricity lock
better to powered by 12VDC, and no more than 1.5 A electric
current At this time, the electric current of supply should be
above1A than lock power. If the parameter of lock power
surpasses this scope, please connect technical personnel. If the
power had not met above requests, it possibly causes to be
unable normally to drive the electricity lock, even damage the
device.
10. Before device to be connected please read and always follow
"Quick connect Guide" closely. Because the wrong wiring will
cause the core block and sensor to burn out, insult in device to
break down, at this cause Honeywell is not liable for any damages
and trouble.

Fingerprint T&A Access Control System User Guide
- -3
11. If the space between power adapters and device is too long,
please do not use the twisted-pair or other type ferrules for the
power wire. When the power wire is choused, you should consider
attenuation of voltage, which has passed long distance transfer.
12. Please use specialized RS485 cable and the RS232/485
converter with power to hookup the network, the bus structure
apply to connect with each device. When a long cable is used to
transfer signal, it is need to connect a matching resistance to
receiver, and its value is 120Ώ.
13. Other more details items; please see also the user manual, the
operating instructions and the appendix and so on.

Fingerprint T&A Access Control System User Guide
- -4
2 System Configuration
2.1 The illustration of system construction

Fingerprint T&A Access Control System User Guide
- -5
2.2
The sketch map of communication
1, Access Control System directly connects with PC through
RS232 or TCP/IP
2, Access Control System connects with PC through RS485
network
3, Access Control System connects with PC through TCP/IP
network
.

Fingerprint T&A Access Control System User Guide
- -6
3. Installation
3.1 Fixing mounting plate
①
Take out a Access Control System
,
dismantle the screw
between machine body and mounting plate until it is out, see
figure (1).
②
Carefully take up the bottom of mounting plate, see figure (2),
push it up, see figure (3), then take away the mounting plate.
③
Determine the position of mounting plate on the wall. The
Access Control System should be mounted on the external wall of
the door approximately 1400mm from the ground to the unit
bottom. After the position is determined, you could drill a hole
(18mm*20mm) for cable out, see below figure shadowed part.
④
Make the hole of mounting plate meet the drilled hole on the
wall, Use the screw to fix it on the wall, (for the details please see
following figure)
⑤
after installation, please make sure the mounting plate is
reliable, fasten, not loosed.

Fingerprint T&A Access Control System User Guide
- -7
3.2 Connect with peripheral equipment
Caution: Do not to connect peripheral equipment before the
power of the device is cut down, otherwise it is possible to
damage the device badly.
Please follow instruction to connect peripheral equipment
1) Door sensor connection
(
sensor, GND
)
2) Exit-button connection
(
Button GND
)
3) Alarm connection
(
Alarm+, Alarm-
)
4) Door lock connection
(
NC, COM, NO
)
5) Ethernet connection
(
RJ45-1, RJ45-2, RJ45-3,RJ45-4
)
6) RS232 connection
(
232RX, 232TX, GND
)
7) RS485 connection
(
485A,485B
)
8) Wiegand output connection
(
WD0,WD1,GND
)
9) Cable Bell (
Bell+, Bell-)
10) Power connection (
GND, +12V)
Cable socket

Fingerprint T&A Access Control System User Guide
- -8
The definition of socket without Wiegand input
The definition of socket with Wiegand input
RJ45-1
RJ45-2
RJ45-3
RJ45-6
WD0
WD1
GND
232RX
232 TX
GND
485 A
485 B
Alarm
-
Alarm +
NC
COM
NO
Button
GND
Sensor
Bell+
Bell-
GND
+12V
BEEP
GLED
RLED
WD1
WD0
GND
+12V
Jump

Fingerprint T&A Access Control System User Guide
- -9
3.2.1 Door Sensor
The door sensor is used to detect the door open-close status,
Access Control System can monitor if the door has been
unauthorized open through the door sensor, at this time it can
output a alarm signal, moreover, Access Control System can
trigger prompt warning if after surpassing a timed period, the door
still open.
3.2.2 Release Button
The exit-button is installed for in-door operation. When the switch
of the button is close, the door will open. The distance is
approximately 1400mm from ground to exit-button bottom. Make
sure that the exit-button position is to align correct, upright and the
connection is accurate and reliable. (Unused exposed end of
cable should be cut off, and use insulating tape to wrap it.) Pay
attention to electromagnetic disturbance. (For example: The light
switch, the computer and so on)
3.2.3 Alarm
Access Control System alarm output is a switch signal
,
it is able to
connect with simple alarm by serial circuit, it also apply to top
grade alarm and monitor system as a trigger signal( this machine
alarm function only support 12 VDC Warner)

Fingerprint T&A Access Control System User Guide
- -10
3.2.4 Connection with lock
The way of installing door lock depends on the type of lock and
local condition. Internal resistor, which comes from long distance
transfer, should be taken into consideration when selecting the
cable of electric power. The door lock should be installed reliable
and stable. Ensure the wiring is correct. For the strike lock and
electromagnetic lock, you should pay attention to positive and
negative terminal connection. The unused bare end of wire should
be cut off and use insulating tape to wrap it. The delay time of
strike lock is adjustable according to different conditions.
Normally close (NC), under normal state the equipment keeps up
closed, if force the equipment open, the circuit cut off, brings out
the state change.
Normally Open (NO), under normally state the circuit is cut off, if
force the equipment open, the circuit will be closed, and produce a

Fingerprint T&A Access Control System User Guide
- -11
state change.
Power Ground
(
((
(
GND
)
))
)
,
Current loop ground
Input terminal of door sensor
(
((
(
Sensor
,
,,
,
GND
)
))
)
the input port of
door sensor accepts the signal which come from normally
closed contact to detect the door opening and closing state, when
the door is in closed, the contact keep in closed state, if the door is
opened by someone , the circuit break, thus bring out state
change. If unauthorized user opens this door or opening time is
too long, the controller will send alarm
Input terminal of release door button
(
((
(
Button
,
,,
,
GND
)
))
)
The input
port of release door button accepts the signal which come from
normally opened contact to indicate that somebody want to go
out, the input equipment such as “ action detector”, “ press
sensitivity floor board” or exit-door button all serve as source to
send signal
,
if nobody send out request to want to go out, the input
keep disconnection , if somebody want to go out, they trigger
release door button, the circuit is closed. Produce state change,
the controller responded to the request, unlock and permit door
serve as passage mode.
Note
:
1
)
the process of performance to unlock door is control by relay,

Fingerprint T&A Access Control System User Guide
- -12
when you install door lock, there are two thing you must think
about, -- safety and security , in other words, do you want which
result that is if lose control of this door, the door is still in
safety—“lost control but safety” or if lose control of this door, the
door still is security--- “ lost control but security”
2
)
When the Access Control System connected with Electric lock,
to prevent the self-inductance EMF to affect the access control
system, you need to parallel one FR107 diode (do not reverse the
polarity) . Please use the equipped diode in the package.
“Lost control but safety” is that the power supply cut off (maybe
the power supply is cut or the controller lose control of itself, the
door will be open automatically, and permit everybody freely to
pass in and out, the door is not ability to be closed until the system
power on, these type of doors are installed in the protective area
which ensure everybody is able to pass in and out. One
representative application of “ lost control but safety” is to use
electromagnetism lock, under normal power supply, the door is
controlled by the controller, once the power supply break off, the
electromagnetism lock will lose magnetism and does not take
effect, the door become a passage mode
“Lost control but security” is that the power supply cut off, the
door will be locked automatically, do not permit external personal
to come in, but permit internal personal go out, the door is not to
be unlocked until the system power supply is in gear. Make sure

Fingerprint T&A Access Control System User Guide
- -13
that the door of “lost control but security” will be installed in the
area, which needs to be protected through fair and foul. One
representative application of “ lost control but security” is to use
electrical lock, if the power supply break off, the external personal
is not able to open the door, but the internal person can open the
by manual operation.
In the following three cases, we recommend that fingerprint
machine and lock be powered separately.
1) The working voltage of the lock is DC12V, but the current
difference of the fingerprint machine and the lock doesn’t exceed
1A.
2) The lock voltage is not DC12V.
3) The distance between lock and fingerprint machine is too far.

Fingerprint T&A Access Control System User Guide
- -14
1
、
NC lock connection
(
Access Control System and lock power by
one adapter together , Jump 2,3 pin closed
)
.
2
、
NO lock connection
(
Access control System and lock powered
by one adapter together , Jump 2.3 pin closed
)
.
Lock
Lock

Fingerprint T&A Access Control System User Guide
- -15
3
、
the output relay signal by Access control System, NC lock
connection
(
Access Control System and lock powered by
independent adapters jump 1,2 closed
)
4
、
the output relay signal by Access control System, NO lock
connection ( Access Control System and lock powered by
independent adapte
r
Lock
Lock
Lock Power
Lock Power

Fingerprint T&A Access Control System User Guide
- -16
3.2.5 Ethernet connection
1
)
Access Control System connects with PC through cross cable
2
)
Access Control System connects with PC through network and
HUB to create a local network

Fingerprint T&A Access Control System User Guide
- -17
3) RJ45 plug wiring diagrams for Ethernet
a) RJ45 plug standard
b) Ethernet 10/100Base—T Crossover Cable
mostly apply to HUB and Switch
,
or directly connect two Ethernet
terminals(not through HUB), fully support 10Base-T and
100Base-TX.
Plug1 Pin Pin Plug 2
TX+ 1 <——> 3 RX+
TX- 2 <——> 6 RX-
RX+ 3 <——> 1 TX+
RX- 6 <——> 2 TX-
This manual suits for next models
1
Table of contents
Other Honeywell IP Access Controllers manuals

Honeywell
Honeywell NetAXS-123 User manual

Honeywell
Honeywell PRO22IC User manual

Honeywell
Honeywell NetAXS-123 Troubleshooting guide

Honeywell
Honeywell MPA2C3 User manual

Honeywell
Honeywell IdentIPoint User manual

Honeywell
Honeywell Tema-Voyager Compact User manual

Honeywell
Honeywell MPA1C1 User manual

Honeywell
Honeywell IDENT-KEY 3 Instruction manual

Honeywell
Honeywell MPA2 Troubleshooting guide

Honeywell
Honeywell OmniAssure Touch Mullion User manual