DR FUJI QL/DMS.PRO6-A User manual

GERMANY
Li-ion
technical standard:Q/91510108629517429X·6—2019
contact us:1-800-526-0278
4399 ingot street,fremont,ca,94538,united states
facebook.com/drfujiusa
insatgram: drfujicyberstudio,drfujifitness
www.drfuji.com
DEEP MUSCLE MASSAGER
QL/DMS.PRO6-A
INSTRUCTIONS

Portable Deep Muscle Massage Instrument is a device for deep muscle and
fascia relaxation. It is suitable for physical massage after exercise. It can reduce
muscle stiffness and pain, alleviate muscle fatigue and accelerate blood circulation
to achieve the purpose of improving the health of body soft tissue.
Marks Introduction and Purpose
purpose
· Physical massage after exercise
Environmental conditions
Normal working conditions
Temperature:
Relative humidity:
Barometric pressure:
5℃~40℃;
≤90%;
70kPa~106kPa;
Charger:IN:100-240V~ 50/60Hz 0.6A
OUT:26V 1A
instrument:Rated voltage:22.2V
Battery capacity:2500mAh
·
·
·
·
·
01
Influence of
environment and energy
· Because the electromagnetic field produced by massage motor is relatively
small, it will not affect the electronic equipment and human body in general!
If the main engine (including lithium batteries) and accessories of this instrument
reach the service life, please do not discard them at will. Otherwise, electronic
waste will pollute the environment. Please make corresponding treatment
according to the relevant regulations of local environmental protection
department for the treatment of such electronic waste.
·
Li-ion
Direct current
Alternating current
WEEE Recovery Identification
Please read the instructions carefully.
Identification of reclamation and utilization of
lithium batteries
DEEP MUSCLE MASSAGER

Techinical parameter
· Product Name:PORTABLE DEEP MUSCLE MASSAGER
· Product Model:QL/DMS.PRO6-A
· Structure:It mainly consists of control part, massage head and lithium battery;
· The vertical vibration frequency ≤ 60 Hz;
· Amplitude:10mm
· Rated power:25W;
· The instrument has output control function switch;
· Massage head can be replaced as needed;
· Running mode: intermittent loading.
02 03
Safety notes
The following contents must be known before use, otherwise it may
cause damage or danger!
About the User Population and Location
About Instrument Operation
· For use only by healthy adults other than the elderly;
Use the product only in the soft tissue of the body without pain or discomfort;
Do not use on the head or any hard or bony part of the body;
Silting may occur either under moderate pressure or under pressure. Check the
massage area regularly and stop using it once there are signs of pain or
discomfort;
It can be used on the dry and clean skin surface of body parts, and gently press
and move on the skin;
Do not use near the skeleton with less muscle coverage, such as tibia, acrotarsium,
the back of hand;
Do not use in or around sensitive areas such as eyes, teeth, breast augmentation,
reproductive organs, prostheses, etc;
Do not use the product at any possible fracture site;
If the pain is persistent, stop using it immediately and consult your doctor;
This product is not a medical device. It is not recommended for medical use and
is not intended for medical use in hospitals;
This product is not a medical device and is not recommended for medical use. It
is not intended for medical use in hospitals;
· Vibrating head which can produce the best effect should be used;
·
·
·
·
·
·
·
·
·
·
· Check the power connection of the main engine and adapter before use. If there
is any damage, the manufacturer or its designated professionals must replace it
in order to avoid danger;
Main structure of machine
Small metal
flat head
Metal cylindrical
head (large)
Removable and replaceable titanium alloy massage head
Battery Indicator
Start/Stop/Gear
Handle/Removable
Battery
Left:
Handle unlock
right:
Handle lock
Gear indicator
Power switch
DC charging port
bottom
Metal cylindrical
head (small)
DEEP MUSCLE MASSAGERDEEP MUSCLE MASSAGER

04 05
Installation
Installation environment
Installation method
Equipment must be installed in the following environments:
Open the packing box and check whether the main engine and accessories are in
good condition. If there is any defect, please inform your supplier immediately;
Connect the battery to the host, and select the appropriate massage head to
connect with the host.
·
·
·
·
·
·
·
Temperature:5℃~40℃;
Relative humidity:≤90%;
Barometric pressure:70kPa~106kPa;
Charger:IN:100-240V ~50/60Hz 0.6A
OUT:26V 1A
instrument:Rated voltage:22.2V
Battery capacity:2500mAh
Test
After installing the battery and massage head, turn on the power switch and press the
“Start/Stop/Gear” button to observe whether the device is operating normally.
·
·
Equipment and accessories should be in good condition;
Operate the equipment according to the instructions and check the functions. If
the equipment can run normally, the product will pass the acceptance test.
Acceptance
·
·
·
·
·
·
·
·
·
·
·
· Do not put batteries in water or wet them!
· It is forbidden to charge the battery under the condition of fire source or extreme heat.
Do not use or store batteries near heat sources such as fires or heaters! If the battery
leaks or smells, it should be removed immediately from the vicinity of the open fire;
· Please use a special charger;
· Do not put batteries into fire or heat them;
· It is forbidden to short circuit the positive and negative poles of batteries with
wires or other metal objects. It is forbidden to transport or store batteries with
necklaces, hairpins or other metal objects;
· Do not use nails or other sharp objects to pierce the battery shell. Do not hammer
or pedal the battery!
· Do not hit or throw batteries!
· It is prohibited to decompose batteries in any way!
· Do not place batteries in microwave ovens or pressure vessels!
· If the battery emits odor, heat, distortion, discoloration or any other abnormal
phenomena, it should not be used; if the battery is in use or charging, it should be
immediately removed from the instrument or charger and stopped using!
·
·
·
·
·
Do not place any object in the ventilation hole of the product;
Do not immerse in water or let water enter the ventilation holes of the product;
Do not fall or improperly use;
Before each use, we should carefully check the operation status of the main engine,
batteries, chargers and so on to ensure that they can meet the normal use;
Do not change or modify the product in any way;
Never let the product run or charge in an unattended state;
The special charger provided by the manufacturer must be used for charging. It is
strictly forbidden to use other power supply equipment to charge the product;
It is forbidden to start the equipment during charging;
It is forbidden to plug the battery after the power switch is turned on;
It is forbidden to put equipment into fire;
Don't use it for more than one hour continuously. Let the equipment stop for 30
minutes before reusing.
About Batteries
About Charging
Before the first use, charge for about three hours and fill up the battery. When
charging, the device can be connected or disconnected;
When charging, the DC end of the special adapter is connected to the charging port
of the battery;
The battery icon on the battery flickers regularly, and the digital display of the
battery power indicates that the battery is being charged;
When the battery icon on the battery stops flickering and remains on, the digital
display shows that 100% of the battery is full;
Batteries can be charged at any time and at any level of electricity;
·
·
·
When the power is less than 20%, the power indicator digital tube flickers, please
charge it in time;
It is not recommended that the battery power be completely depleted to 20% level;
The average running time of the equipment is three hours, depending on the frequency
of vibration and the applied pressure during use.
DEEP MUSCLE MASSAGERDEEP MUSCLE MASSAGER

06 07
Maintenance
Transportation Climate and
environmental conditions
Transportation
Storage
Usage Method
1) Battery& massage head
2)
3)
4)
Aim at the bottom slot of the device and insert the battery into it as shown in
Figure 1 below. Make sure that the battery is firmly fixed at the bottom of the
device (Fig. 2). There should be no gap between the battery and the fuselage (Fig.
3 is wrong).
When the equipment is closed, the massage head is fully inserted by pressure.
When the massage head is disassembled, it can be pulled out. (Pay attention to
safety: when installing the vibrating head, please insert it directly and pull it out.
No rotation is allowed).
To tear down the battery, one hand dials the battery lock key to the "unlock"
key, and the other hand pulls down the battery/handle.
Turn the power switch at the bottom of the battery to ON and start the
device; Switch the power card to OFF position and close the device.
When the power switch is in ON , press the " " touch key on
the panel and the gear will be switched between 0-5 gears. If the
" " touch key is pressed for 2 seconds, the output of the
instrument will stop immediately.
· The LED light will indicate the frequency level of the corresponding hit times,
the lowest in Grade 1 and the highest in grade 5.
Apply the required pressure with the preset vibration massage
frequency to massage the corresponding body parts.
Left:
Handle unlock
right:
Handle lock
Fig.1 Fig.2Fig.3
Crevice
Seamless
· Clean the equipment with a slightly wet towel and dry it with a soft cloth;
· If you do not use the equipment for a long time, please separate the battery from
the mainframe and store it in the box;
· Do not disassemble the screw or attempt to disassemble the equipment;
· In order to achieve the best use of new batteries in a short period of time,
complete charging and discharging can be carried out three or more times.
· When the equipment is not used for a long time, the battery should be charged
once a month.
·
·
·
Temperature:-40℃~+50℃;
Relative humidity:≤90%
Barometric pressure:70kPa~106kPa;
·
·
·
This product is suitable for automobiles, trains, ships, airplanes and other modes
of transportation;
During transportation, it should be fixed to prevent violent vibration, collision, roll
and fall; and be upward, careful, light and rainproof;
No more than 5 layers of massager stacked.
· Massage equipment should be stored in a well ventilated, non-corrosive gas
warehouse, 250 mm off the ground;
When massage instrument is not used for a long time, it should be packed and
stored after cleaning. It is better to take it out and recharge once a month to
prevent dampness.
· No more than 5 layers of massager stacked;
·
DEEP MUSCLE MASSAGERDEEP MUSCLE MASSAGER

08
Responsibility
Product Name
Date of
purchase
Fault
Description
Customer contact
information
Product Model
If the products produced do not meet the product standards,
our company is responsible for repairing, replacing and returning.
Our company assume corresponding responsibilities for personal
injury caused by defective products and property damage other
than defective products. However, in any one of the following cases,
our company is not liable.
Our company carries out lifelong maintenance and technical
service for products. If there is a breakdown, please contact our
technical service department (the phone number is at the bottom of
the box). The quality problems occurring during the stipulated quality
assurance period will be repaired free of charge for users. (Please refer
to the warranty card for the warranty period agreement).
· When products are put into circulation, the defects that cause damage (personal,
property) do not exist;
· There is no defect or appearance defect when the product delivers;
· Buyers and users do not read the instructions carefully, do not follow safety
precautions and warning instructions.
· Violation of the provisions on the transportation, installation, use, maintenance and
storage of products causes loss of products, persons and property.
Remarks
First, our company( ) implements a
warranty for consumers who purchase this product. The product and the accessories (non-
consumable materials) are guaranteed for one year from the date of purchase (the date of
purchase invoice).
Second, please note: Any one of the following conditions is not covered by the warranty:
1. Exceeding the validity period of the warranty;
2. Failure to use, maintain or keep in accordance with the requirements of the product use
instructions;
3. The repairer who is not responsible for the warranty causes the loss;
4. Loss caused by using accessories that do not match this product;
5. Loss caused by force majeure.
Manufactor :sichuan Qianli-beoka Medical Technology Inc.
DEEP MUSCLE MASSAGER
Table of contents
Popular Massager manuals by other brands

HoMedics
HoMedics SDN-6000ATNDY Instructions for use

Lanaform
Lanaform LA110103 instruction manual

Johnson
Johnson J-6800 Service manual

Palmero
Palmero PalmeroGun FIT manual

ULTIMATE SPEED
ULTIMATE SPEED 346416 2004 Assembly and Safety Advice

HoMedics Beauty
HoMedics Beauty Purete Plus Beauty Routine Expert instructions