What is a programmable room
thermostat?
...an explanati n f r h useh lders
A programmable room thermostat is both a programmer
and a room thermostat A programmer allows you to set
‘On’ and ‘Off ’ time periods to suit your own lifestyle A room
thermostat works by sensing the air temperature, switching
on the heating when the air temperature falls below the
thermostat setting, and switching it off once this set
temperature has been reached
So, a programmable room thermostat lets you choose what
times you want the heating to be on, and what temperature
it should reach while it is on It will allow you to select
different temperatures in your home at different times of the
day (and days of the week) to meet your particular needs
Turning a programmable room thermostat to a higher
setting will not make the room heat up any faster How
quickly the room heats up depends on the design of the
heating system, for example, the size of boiler and radiators
Neither does the setting affect how quickly the room cools
down Turning a programmable room thermostat to a lower
setting will result in the room being controlled at a lower
temperature, and saves energy
The way to set and use your programmable room
thermostat is to find the lowest temperature settings that
you are comfortable with at the different times you have
chosen, and then leave it alone to do its job The best way to
do this is to set low temperatures first, say 18C, and then
turn them up by one degree each day until you are
comfortable with the temperatures You won’t have to adjust
the thermostat further Any adjustments above these settings
will waste energy and cost you more money
If your heating system is a boiler with radiators, there will
usually be only one programmable room thermostat to
control the whole house But you can have different
temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators If you don’t
have TRVs, you should choose a temperature that is
reasonable for the whole house If you do have TRVs, you can
choose a slightly higher setting to make sure that even the
coldest room is comfortable, then prevent any overheating in
other rooms by adjusting the TRVs
The time on the programmer must be correct Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time
You may be able to temporarily adjust the heating
programme, for example, ‘Override’, ‘Advance’ or ‘Boost’
These are explained in the manufacturer’s instructions
Programmable room thermostats need a free flow of air to
sense the temperature, so they must not be covered by
curtains or blocked by furniture Nearby electric fires,
televisions, wall or table lamps may prevent the thermostat
from working properly
Technical Data
Model 22084 22088
P wer supply 2 X AA 1.5V 230V AC 50Hz
alkaline batteries
Battery life 3 years typical –
Switch rating
Heating (switch N.O.) 16(2)A 230 Vac
Switch type SPDT (v ltage free c ntacts)
Min. rec mmended current 10mA @24Vac (inductive)
Ambient temperature Operating 0°C t 50°C
St rage – 20°C t 85°C
Ambient humidity Operating 25% t 85%
(n n c ndensing) St rage 15% t 95%
Temperature range 0°C t 32°C
Accuracy (between 7°C & 32°C) 0.5°C
Timing res luti n 1 minute
Temperature res luti n 0.1°C
Rated impulse v ltage 2.5KV
Ball pressure test 75°C
P lluti n situati n Degree 2
Pr tecti n level IP30
Wiring: Designed f r fixed wiring nly,
t c mply with IEE wiring regulati ns
Dimensi ns
Installer Options.
If y u wish t change any f the Installer Opti ns as sh wn
bel w, enter the Installer Opti n Menu fr m Aut m de by
pressing < and + simultane usly f r 5 sec nds.
Pressing < and + again f r 5 sec nds will exit the Menu and
return t Aut m de.
Once the Installer Opti ns screen has been selected (Fig 8), the
< and > butt ns all w y u t scr ll thr ugh the Menu (sh wn
bel w). The + and - all w y u t change values. Once a value
has been changed pressing > bef re exiting the Menu will save
the new setting. (Fig 9 sh ws Opti n 1 OFF).
Access protection lock.
The access pr tecti n l ck all ws the installer t l ck the
Digistat+2 s that the user cann t make any adjustments.
The default is OFF m de all wing the users t adjust the
Digistat+2 (see User Guide).
T L ck the Digistat+2 settings enter the Installer Opti ns Menu
(Refer t Installer Opti n 1) and select On and press > t accept.
Once the Installer Opti ns Menu is exited all butt ns will be
l cked.
T switch ff the Pr tecti n L ck enter the Installer Menu and
change t OFF. Press > t accept.
Once the Installer Menu is exited all butt ns will be free t adjust.
Freeze protection.
Freeze pr tecti n will switch n the heating if the r m
temperature falls t 5ºC and will then c ntr l the temperature at
7ºC even if the Digistat+2 is in OFF m de.
The freeze pr tecti n default is ON.
T switch ff the Freeze pr tecti n m de enter the Installer
Opti ns Menu (Refer t Installer Opti ns 2) and change t OFF.
Press > t accept.
Low and High Limit set points.
The user temperature set p ints defaults are High 32ºC and L w
7ºC, t change these limits enter the Installer Opti ns Menu
(Refer t Installer Opti ns 3 & 4).
Intelligent Delayed Start (Energy saving feature).
The Intelligent Delayed Start is an energy saving feature which
aut matically reduces the warm up time f r the heating system.
As the weather bec mes milder, Intelligent Start will delay the
heating start times s that fuel is n t wasted bringing the r m
up t temperature earlier than necessary.
N te: Intelligent Delayed Start nly applies in Aut m de.
Intelligent Delayed Start default is in OFF m de.
T switch n Intelligent Delayed Start enter the Installer Opti ns
Menu (Refer t Installer Opti ns 5).
N te the Intelligent Delayed start pti n is n t suitable f r
Hydr nic underfl r applicati n.
Ensure Installer pti n 5 is set t Off bef re final c mmissi ning
f r Hydr nic underfl r applicati n.
Valve protection.
In s me hydr nic heating systems there may be a requirement t
pr tect the valve by perating it nce a day, f r a given peri d
with ut bringing n the heating system.
If valve pr tecti n is selected the valve will be perated f r a
peri d as sh wn in Valve pr tecti n time (mins).
Valve pr tecti n time every day at 10.00am.
Valve pr tecti n default is OFF.
T enable the valve pr tecti n m de enter the Installer Opti ns
Menu (Refer t Installer Opti n 6)
Valve protection time (mins).
Valve pr tecti n time can be set between 1 and 5 minutes
(default 3 minutes)
T change this nce a day n time enter the Installer Opti ns
Menu (Refer t Installer Opti n 7).
Installer
Options What is it Select between Default
1 Access pr tecti n l ck On Off Off
2 Freeze pr tecti n On Off On
3 L w limit set p int ºC 7 High limit 7
4 High limit set p int ºC L w limit 32 32
5 Delayed start
(Energy saving feature) On Off Off
6 Valve pr tecti n On Off Off
7 Valve pr tecti n time (Mins) 1 5 3
8 Sens r fault functi n On Off Off
9 Applicati n type 1 0 0
Sensor fault function.
When the display sh ws an err r c de (E1) r (E2) this indicates
a sens r fault and the heating system will remain Off.
(E1) = internal sens r and (E2) = external sens r.
If (E1) is sh wn the Digistat+2 sh uld be replaced.
If (E2) is sh wn, first check the external sens r terminal bl ck
c nnecti ns bef re replacing the Digistat+2.
Sens r fault functi n all ws y u t temp rally set the Digistat+2
t cycle the heating system 30% On and 70% Off until y u have
replaced the pr duct.
This can be d ne by entering the installer Opti n Menu (Opti n
8) and selecting On. Press > t accept.
T reset t default Off, entering the installer Opti n Menu
(Opti n 8) and selecting Off. Press > t accept.
Application type.
Model 22084
(Battery) can be used f r radiat r r Hydr nic underfl r
applicati ns.
In installer Opti n select:
0 = Radiat r.
1 = Hydr nic underfl r.
Default 0 = Radiat r.
Model 22088
(Mains) can als be used f r electric heat applicati ns.
0 = Radiat r and electric heat.
1 = Hydr nic underfl r.
T change applicati n enter the installer Opti n Menu and refer
t Opti n 9.
Drayton – Digistat+2 24 Hour Programmable Room
Thermostat
Pr grams are the same every day (M nday t Sunday).
TEAR HERE TEAR HERE
(Fig 8) (Fig 9)
When y u get t the event y u wish t change press + r - t
change the required time, then Press > t accept. Use + r - t
select the required temperature, then > t accept. Digistat+2 will
n w sh w the next time/temperature event. T exit press < r >
until y u return t Aut m de.
How to change User Options.
If y u wish t change any user pti ns 1 t 8 sh wn in table 1 they
can be accessed fr m Aut r Man by pressing < and >
simultane usly f r 3 sec nds. Once y u have accessed the user
setting Menu (Fig 13) press > t scr ll thr ugh selectable pti ns
1 t 8. The settings f r each pti n can be changed by pressing +
r - as required. Press > t accept the change and m ve t the
next pti n. T exit press < and > simultae usly f r 3 sec nds.
Alternatively, n t pressing any butt ns f r 2 mins will cause the
Digistat+2 t return t Aut . (Fig 13a) sh ws pti n 1 24 (24
h ur cl ck).
Only selected pti ns which have been accepted by pressing >
will be changed.
(Fig 11)
(Fig 12) (Fig 12a)
(Fig 13) (Fig 13a)
Pre-set programs for Digistat+2 24 Hour.
Program 1 (9 till 5) as shown below
M nday t Sunday
Events 1 2 3 4 5 6
Time 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 20.0 16.0 16.0 16.0 21.0 7.0
Program 2 (Home for lunch)
M nday t Sunday
Events 1 2 3 4 5 6
Time 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 21.0 16.0 21.0 16.0 21.0 10.0
Program 3 (Home worker)
M nday t Sunday
Events 1 2 3 4 5 6
Time 6:00 8:30 12:00 14:00 17:30 22:30
Temperature C 21.0 19.0 21.0 19.0 21.0 16.0
How to change the pre-set time/temperature program to my
own selection.
Press > t select the day functi n. (refer t fig 11).
This indicates that any changes made are valid f r all days f the week.
Press > t view the existing time/temperature event (1). (Fig 12)
time will flash. Press > again t view the temperature setting,
temperature will flash. Press > again t view the 2nd
time/temperature event (Fig 12a).
How to change temperature offset (Option 6).
The temperature displayed n the therm stat may n t match
that f ther temperature measuring devices in the c ntr lled
space, because f its l cati n. The displayed and set temperature
may be ffset t bring it in line with ther devices. T adjust the
temperature, enter the user pti ns, select pti n 6. The
temperature may be ffset by +/- 5 degrees by pressing the +
and – keys. Press > t accept the desired change.
How to restore the built in time temperature programs
(Option 7).
Enter user pti ns, select pti n 7 and use + and – keys t select
desired pti n. Off = current pr grams retained. On = rest re
fact ry pr gram settings. Press > t select the desired change.
Please note enabling this function will lose any user changes
to the preset programs.
How to switch the Digistat+2 and heating system off
(Option 8).
T switch the Digistat+2 and the heating system ff y u need t
enable the Off functi n. Enter user pti ns, select pti n 8 and
use + r – keys t select On t enable the Off functi n .The
therm stat and heating system will n w be Off unless the
temperature in the c ntr lled space falls bel w 7 C the fr st
pr tecti n set-p int. The LCD will display Off and r m
temperature nly and the keys will n t functi n. T switch On
the Digistat+2 enter user pti ns select pti n 8 and use + r –
keys t select Off t disable the Off functi n. The therm stat will
n w regulate the heating system in line with the currently
selected pr gram. Please n te this d es n t effect the perati n
f d mestic h t water where pr vided.
How to change from 24hr to 12hr clock (Option 1).
Enter user pti ns, select pti n 1 and use + and – keys t select
desired pti n, 12 = 12hr and 24 = 24hr. Press > t accept change.
How to change the default manual set-point temperature
(Option 2).
Enter user pti ns, select pti n 2 and use + and – keys t set
desired temperature. Press > t accept desired change.
How to change to another predefined program 1, 2 or 3
(Option 3).
Enter user pti ns, select pti n 3 and use + and – keys t
select desired pr gram 1, 2 r 3. 1 = pr gram 1, 2 = pr gram 2
and 3 = pr gram 3. Press > t accept desired change.
How to change the number of program events per day
(Option 4).
Enter user pti ns, select pti n 4 and use + and – keys t select
desired pti n. 2 = 2 time / temp events per day, 4 = 4 time /
temp events per day and 6 = 6 time / temp events per day. Press
> t accept desired change.
How to switch on/off the automatic summer / winter time
change (Option 5).
Twice a year the actual time is aut matically changed t keep it in
line with the summer / winter time change. Default setting is On.
If y u wish t disable / enable this feature enter user pti ns,
select pti n 5 and press – r + key t display Off r On as
desired. Press > t accept desired change.
User
options What is it Min Max Default
1 Change 12h r 24h cl ck 12 24 24
2 Change the manual set
p int temperature
0
C7
0C 32 0C 20
0
C
3 Change t an ther
pre-set pr gramme 1 3 1
4 Change the number f
pr gramme events per day 2, 4 r 6 6
5 Switch n/ ff aut matic
summer/winter time change On Off On
6 Change temperature ffset
0
C-5 5 0
7 Rest re pre-set pr gramme On Off Off
8 T enable Off functi n On Off Off
(Table 1)