What isaprogrammer?
...an explanation for householders
Programmers allow you to set ‘On’ and ‘Off’ time periods.
Some models switch the central heating and domestic hot
water on and off at the same time, while others allow the
domestic hot water and heating to come on and go off at
different times.
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle.
On some programmers you must also set whether you want
the heating and hot water to run continuously, run under the
chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating pro-
gramme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These
are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched
the heating off. And, if you haveahot-water cylinder, the
water heating will not work if the cylinder thermostat detects
that the hot water has reached the correct temperature.
INSTALLATION INSTRUCTIONS
PLEASE NOTE: INSTALLATIONMUST ONLY BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR
HEATING ENGINEER.
MAKE SUREMAINS INPUT HAS A 3 AMPFUSE.
TECHNICAL DATA
LifestyleProgrammers and Timeswitchesconform to the
essential requirements of these Directives:
2014/30/EC – Electromagnetic compatibility
2014/35/EC – Low voltage
INTRODUCTION Cont...
Thereare 3 models in the Lifestyle range:
LP241Si–a24hr program, with central heating andhotwater
working independently for up to 3 heating periods each day, and
every day the same.
LP522Si – a 5/2-day program allowingfor different timings at
the weekends, withcentral heating and hot water working
independently for up to3heatingperiods each day.
LP722Si–a7-dayprogram allowing for different timings on
eachday of the week, with central heating and hot water
working independently for up to 3 heating periods each day.
If the engineer hasn’t set your timings for you, yourprogrammer
will work with a standard program that has beenset at the
factory. If this doesn’tsuit you, it’s very easy to change it –
when you’ve readthis introductory section, simply go to the
section thatcontains your programmer model.
Remember:
Make your changes usingthe SET?, YES/-, and + buttons on
the programmer, found under the bottom flap.
You can’t set ON1 as the last timing beforemidnight,but you
can set OFF3 after midnight–providing it’s notmore than 23
hours and 59 minutes after ON1.
You need to set thetimings in sequence – i.e. ON1, OFF1, ON2,
OFF2, ON3, OFF3. If youget out of sequence, the display will
flash a warning.
SWITCHING
ON 1 – start of first timed period
OFF 1 – end of first timedperiod
ON 2 – start of second timed period
OFF 2 – end of second timed period
ON 3 – start of third timed period
OFF 3 – final switch-off of the day
Theengineerhas set yourprogram and timings–you
won’tneed to do anythingelse. Just keepthis guide in a
safe place forfuturereference.
DAY-TO-DAY VARIATIONS
Sometimes you mightneed to change theway you use your
central heating or hot water temporarily – perhaps due to an
unusually cold day, or exceptional demand for hot water.
Here’s how to do it–without affecting yourprogram.
Switching on andoff
On the front of the programmer there are twoAdvance/Boost
buttons–oneforcentralheating and one for hot water. They
allow you to switchyour system either on or off, irrespective of
theprogram. So if theheating or hotwater is off, and you want
warmth or hot water now, you can either –
1. Press Advanceto switch it on (ADV will be displayed), and it will
stay on until the end of the next period. Or if the heating/hot
water is on and you don’t need it, press Advance and it will go
off until the beginning of the next ON period.
Advancewill only operate in TIMED or ONCE modes.
2. Press & Hold Boostto switch on for an extra hour ( & BST will
be displayed), thenPress again for two ( ) or three ( ) hours.
To cancel Boost, Press Boost again ( ). Or if the heating/hot
water is already on, using Boost will extend the ON time by one,
two or threehours.
LP241Si, LP522Si & LP722Si PROGRAMMERS
LP111Si & LP711Si TIMESWITCHES
Voltage230V a.c. +10% - 10% 50Hz
Programmer Rating2(1) A 230V a.c. each switch
Timeswitch Rating2(1) A 230V a.c.
Ambient temp Operating: 0º to 45ºC
Storage: -20ºC to 50ºC
Without mains powerDisplay: blank
Time: always kept
Program times: always preserved
Programming resolution 1 minute
WiringFixed wiring only, to comply with
current IEE regulations
Maintenance Must be maintained byaqualified
electrician or heating engineer
Drayton Tempus 6,7 N L 1 2 3 4
Drayton Lifestyle LP112, LP241, LP522, LP722 N L 1 2 3 4
Switchmaster 400, 600 N L 4 3 1
(no connection to terminal 4 on 600)
Switchmaster 805, 900, 900i N L 4 2 3 1
ACL MP (Towerchron) 2 1
ACL FP (Towerchron) 2 1 8 11 6 10
Tempus 3, 4, 6,7(old models),
Danfoss Randall
CP15, CP715,FP15, FP715(Mk18
) E N L 1 2 3 4
Danfoss Randall 3020P, 3060 E 7 6 4 2
Danfoss Randall 4033 (link 1-6) E 7 6 5 3 4 2
Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 1 2
Danfoss Randall 701 (link L-5 and 5-6) E N L 3 1
Danfoss Randall 702 (link L-5 and 5-6) E N L 4 2 3 1
Danfoss Randall 922, 972 (link L-2 and 2-5) E N L 1 4 3 6
Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4
SET5 (link L-2 and 2-5)
Grasslin Towerchron DP 72, QE2 N L 1 2 3 4
Honeywell ST 699/799 (link L-5 and 5-8) N L 7 4 6 3
Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4
Honeywell ST 7100 (link L-3 and 3-6) N L 7 4 8 5
Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4
H121, Tiara (link L-2 and 2-5)
Landis&Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4
252 & 270, RWB9
Myson Microtimer (link L-5 and 5-8) N L 7 4 6 3
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4
(link L-5 and N-N)
Potterton Myson* Mini Minder N L 1 2 3 4
Sunvic Select 207, SunPro 2000 N L 1 2 3 4
Sunvic SP50, SP100 (link L-3) N L 1 4 2 5
Drayton Tempus 1, 2 (new models) N L 1 2 3 4
Drayton Lifestyle
LP111, LP711, LP111Si, LP711Si
N L 1 2 3 4
Switchmaster 300 N L 4 1
ACL TC (Towerchron) 2 1 4 7
Drayton Tempus 1, 2 (old models) N L 1 2 3 4
Switchmaster 980 N L 4 1
Danfoss Randall TS15, 75 (Mk18) E N L 1 4 2 5/6
Danfoss Randall TS715, TS715Si N L 1 4 2 3
Danfoss Randall TS975 E N L 5 4 6 1,2,3
Danfoss Randall SET1, SET1E E N L 5 4 6
Danfoss Randall SET4 E N L 5 4 6
Danfoss Randall 103, 103E, 103E5, 103E7 4 5 6 3 1 2
Danfoss Randall 911, 971 E N L 5 6 4 2
Grasslin Towerchron QE1 N L 2 4
Grasslin Towerchron T2001, T2001Q E N L 7
Honeywell ST 6100A, ST 6100C N L 1 4 2
Honeywell ST 7000B
Horstmann Centaur SC1, SC7 L
Horstmann
Centaur Plus, C11, C17, C17-ZW
N L 2 4 3
Horstmann Emerald 423, Pearl Auto N L 2 4
Horstmann 517, Coronet, H11, H17 E N L 3 4
Landis&Staefa RWB3 N L 4 3
Landis&Staefa RWB30, RWB50, 100, 152, 170 N L 4 4 3
Landis&Staefa RWB7
Potterton Myson EP4000, 4001, 4002, 5002 N L 5 4 2
Sangamo M6
Smiths Centroller Mk1, Mk2 N L 3 2
Smiths Centroller 30 1 2 3/4
Smiths Centroller 300, 980 N L 4 1
Sunvic Select 107, SunProl1000 N L 1 3 2 4
Sunvic SP20, SP35 N L 3 5 4 5
Venner Vennerette N L LINE LOAD
DUAL
CHANNEL
LP241Si, LP522Si, LP722Si
SINGLE
CHANNEL
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
for heating OR hot water
LP111Si,LP711Si
Technical Helpline: 0333 7000622
Web: www.draytoncontrols.co.uk
SERVICE INTERVAL
for heating AND hot water
Installation Instructions
06490050001 ISS F
User’s Instructions
TIMESWITCHES
User’s Instructions
PROGRAMMERS
BEFOREINSTALLATION
First, make sure the mainssupply is switched off!
PROGRAMMER ONLY
The programmer must be settothetype of system it is to con-
trol. The link on the back of the unithastwo settings –Pand G.
P = a fully pumpedand controlled system–allowing
heatingand hot water to be set separately.
G=agravity-fed hot water system – which does not allow
independentsetting of heating without hot water, though
hot water can be controlled alone.
USING AN EXISTING WALL-PLATE
Loosen the securingscrews on the old programmer and
unplug it. Check thatthere’s 70mm clearancetothe right of
the wall-plate,and25mmaboveit. Check the chart on the
nextpagetocompareterminals and if necessary, change the
wiring of the wall-plate to suit. Nowplug the Lifestyle unitinto
the wall-plateandtighten thesecuring screws.
Checkthe 3A fuse, andswitch on the mains.
FITTINGANEW WALL-PLATE
The ideal location is 1.4m above floor level, with reasonable
lighting, goodaccess, no condensation, no extremes of
temperature,andasupporting surface that fully covers the
back of the unit.
Position with 70mm clearancetotheright, 25mm above, and
sufficient room to accessthesecuring screws underneath.
Fix,withterminals at the top, either direct toaflat wall using wall
plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mount-
ing single conduit boxtype UA1 (BS4662) using M3.5 x 14 bolts.
DO NOTUSEASURFACE MOUNTING BOX.
TIMESWITCHTERMINALCOMPARISONS
Earth
Neutral
Live
Common
On
Off
Spare
MAKE MODEL
PROGRAMMER TERMINALCOMPARISONS
Current Models
Earth
Neutral
Live
Ch1 on
Chl2 on
Ch3 on
Ch4 on
MAKE MODEL
Discontinued/Competitors’ Models
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
WIRINGTHETIMESWITCH
Make the wiringconnections as
above. Note that the output
contactsare voltage-free, so
powerneeds to be put on to
Terminal 1 either by linkingfrom
Terminal L or from a separate
supply with a 3A fuse.
WIRINGTHEPROGRAMMER
Arrowed numbers relate to
the junction box.
Consult boiler handbook
for details of pump
overrun wiring.
Connection Charts
Wiring Colour Codes
GR Grey
Y Yellow
BK Black
BL Blue
BR Brown
RD Red
WWhite
OR Orange
YG Yellow/Green
C Common
H Callfor Heat
SSatisfied
N Neutral
E Earth
LLive
*Thermostat Key
USINGADRAYTON SIMP-L-FIT, ALTHOUGH NOT
NECESSARY, WILL MAKE THIS INSTALLATION EASIER.
SWITCHINGSTANDARD PROGRAM
MON-FRI SAT-SUN
ON 1 – start of first timed period6.30am 7.00am
OFF 1 – end of first timedperiod8.30am 9.00am
ON 2 – start of second timed period* 12.00pm 12.00pm
OFF 2 – end of second timed period* 12.00pm 12.00pm
ON 3 – start of third timed period 4.30pm 4.00pm
OFF 3 – final switch-off of the day 10.30pm 11.00pm
Lifestyle
DUAL
CHANNEL
LP241Si,LP522Si,LP722Si
SINGLE
CHANNEL
for heating OR hot water
LP111Si,LP711Si
Technical Helpline: 0333 7000622
Web: www.draytoncontrols.co.uk
for heating AND hot water
User’s Instructions
06490050001 ISS F
THELP711Si 7-DAY ELECTRONIC TIMESWITCHCont...
Changing the timings
Press the SET? button and you’ll see ‘SETPROG?’.
Set all weekdays
Firstyou set the times that are going to be the same for each
weekday, then you can select each day individually and make
any further adjustments. If you want eachday to be quite
different, go straight to ‘Set each day’.
Press the YES button, and the display will ask ‘SETMONtoFRI
PROG?’.
Press YESandyou’ll see ON1, the start of yourfirstheating peri-
od. Adjust it in 1-minute steps usingthe–and + buttons.
If the–and + buttons are held down,the time changes in
10-minute steps.
Press SET?, and you’ll see OFF1, the end of your firstheating
period. Adjustthis in the same way, press SET?, then repeat
theprocedure for ON2, OFF2, ON3andOFF3.
Set eachday
If, after you’ve set OFF3 you want to fine-tune one or more
weekdays, press SET? until you find thefirst day you want to
adjust – then go throughtheprocedure, altering any time you
wish.Press SET? to move on to the next day. When you’ve
finished, press SET? until you see ‘SET SAT SUNPROG?’.
If you don’t want to alter any individual days, keeppressing
SET? until yousee ‘SET SAT SUNPROG?’.
Set weekend
Press YESand alter ON1, OFF1, ON2, OFF2, ON3 and OFF3
times in the same way.
Set eachday
If, after you’ve set OFF3 for both SAT & SUN, youwant to fine-
tune Saturday or Sunday, press SET? until you find the firstday
you want to adjust – then go through the procedure, alteringany
time you wish.Press SET? to move on to the next day. When
you press SET? after setting yourhot water for Sundays, the pro-
grammer will go back to normal operation.
If you don’t want to alter either day, keep pressing SET?
until theprogrammer goes back to normal operation.
If theengineerhas set your program and timings–you
won’tneed to do anythingelse. Just keepthis guide in a
safe place forfuturereference.
INTRODUCTION
Lifestyle Programmers will automaticallyswitch your central
heating and hot water on and off at times that suit you.
Depending on yoursystem, central heating and hot water
caneither both come on and off at thesame time, or work
independently. Thelight on thefront of theprogrammer
shows when eachoneison.
PROG?
SAT
SATSUN
PROG?
MON
PROG?
MON TUE WED THU FRI
INTRODUCTION
Lifestyle Timeswitches will automatically control yoursystem
by switching it on and off at times that suit you. The light on the
front of the timeswitchshows when it’s on.
LP111Si–a24hr program, up to 3 heatingperiods
eachday, andeveryday the same.
LP711Si–a7-dayprogram, allowingfordifferent
timings on eachday of the week, up to 3 heating periods
eachday.
If theengineer hasn’tsetyour timingsfor you,your timeswitch
willworkwith a standardprogram that has beenset at the
factory. If this doesn’t suityou, it’s veryeasy to change it –
when you’veread this introductorysection,simply turn to
the pageforyour timeswitch model.
Remember:
Make your changes using the SET?, YES/-, and + buttons
You can’tsetON1 as the lasttimingbeforemidnight, but you
cansetOFF3after midnight–providing it’s not more than 23
hours and 59 minutes afterON1.
You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
OFF2, ON3,OFF3.Ifyouget out of sequence, the display will
flash a warning.
SWITCHING
ON 1 – start of first timedperiod
OFF 1 –end of first timedperiod
ON 2 – start of second timed period
OFF 2 –end of secondtimedperiod
ON 3 – start of third timed period
OFF 3 –finalswitch-off of theday
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
SERVICE INTERVAL
Lifestyle
Installer note: After installation, tear along perforations indicated and retain this section - only leave
the User instructions with the end user
Installer note: After installation, tear along perforations indicated and retain this section - only leave
the User instructions with the end user
LP711Si –a7-dayprogram, allowingfordifferent timings on
each day of the week, up to 3 heatingperiods each day.
Want to leaveatiming as it is? Just press SET? and move on
to thenext one.
If you need to reset your timings to the standard program and
start again,press ‘SET’ and ‘+’ together to go back to the
pre-set program.
Your systemwill comeonfor up to 3 heating periods every
24hrs.ON1starts the firstone,OFF1finishes it, andsoon.
Notice that ON2andOFF2aresettothesame time.*This
meansyour systemwon’trespond, but if youwant to activate
that middleperiod or change any othertimings–readon.
Thestandard program
WhenyoupressSET?aftersetting OFF3, the timeswitch will
return to normaloperation.
If theengineer has set yourprogram and timings–you won’t
need to do anythingelse. Just keep this guide inasafe place
forfuturereference.
Sometimes you might need to change theway you use your
system temporarily – perhaps due to an exceptionally cold day.
Here’s how to do it–without affectingthe timings in your
program.
Switching on and off
On the front of the timeswitch there is an Advance/Boostbutton.
It allowsyou to switchyour system either on or off, irrespective of
the program. So if the heating is off, and you wantwarmthnow,
youcaneither –
1. Press Advanceto switch it on (ADV will be displayed), and it will
stay on until the end of the nextperiod. Or if the heating is on and
youdon’t needit,press Advanceanditwill go off untilthe
beginning of the nextONperiod.
Advancewillonly operate in TIMED or ONCEmodes.
2. Press&HoldBoostto switch on for an extrahour ( & BST will
be displayed), then Pressagain fortwo ( ) or three ( ) hours.
To cancelBoost, PressBoost again ( ). Or if the heating is
alreadyon, usingBoostwill extend the ON time by one,two or
threehours.
DAY-TO-DAY VARIATIONS
Over-ridingthe program
At the side of the display there
arefour operatingmodes:
OFF= continuously off.
TIMED = on for up to 3 periods a day.
ONCE= on for 1 periodaday, from the start of ON1
to the end of OFF3.
ON = continuously on.
UsetheSELECT button under the flap to change the
mode.
Thiswon’talter the timings in your program, whichyou
canreturn to by selecting TIMED.
THE LP111Si 24hr ELECTRONIC TIMESWITCH
LP111Si –a24hr program, up to 3 heatingperiods each day,
and every day the same.
Want to leaveatiming as it is? Just press SET? and move on
to thenext one.
If you need to reset your timings to the standard program
and start again,press ‘SET’ and ‘+’ together to go back to
thepre-set program.
Thestandard program
Your systemwill comeonfor up to 3 heating periods every
24hrs.ON1starts the firstone,OFF1finishes it, andsoon.
Notice that ON2andOFF2aresettothesame time.*This
meansyour systemwon’trespond, but if youwant to activate
that middleperiod or change any othertimings–readon.
SWITCHING STANDARD PROGRAM
ON 1 – start of first timedperiod 6.30am
OFF 1 –end of first timedperiod 8.30am
ON 2 – start of second timed period*12.00pm
OFF 2 –end of secondtimedperiod*12.00pm
ON 3 – start of third timed period 4.30pm
OFF 3 –finalswitch-off of theday10.30pm
Changing the timings
Press the SET?button and you’llsee‘SETPROG?’.
PROG?
Press the YES button,andyou’llseeON1, the start of yourfirst
heatingperiod. Adjust it in 1-minute steps using the–and +
buttons. If the–and + buttonsare held down, the time changes
in 10-minute steps.
Press SET?,andyou’llseeOFF1, the end of your first heating
period.Adjust this in the sameway, pressSET? then repeat the
procedure forON2,OFF2,ON3andOFF3
Over-riding the program
LP241Si –a24hr program, with central heating and hot water
workingindependently for up to 3 heatingperiods eachday,
and every day thesame.
If the timings haven’t been set for you,then yourprogrammer
will still be on the factory-set standard 24hr program, with
central heating and hot water operating together on the
same timings for every day of the week. But it’s easy to make
changes, and have heating and water workingindependently
– just follow the instructions.
Want to leaveatiming as it is? Press SET? and move on to
thenext one.
If you need to reset your timings to thestandard program
and start again,press ‘SET’ and ‘+’ together to go back to
the pre-set program.
If you don’t press anythingfortwo minutes, the programmer
automatically goesback to normal operation.
THE LP241Si 24hr ELECTRONIC PROGRAMMER
OFF= continuously off.
TIMED = on for up to 3 periods a day.
ONCE= on for 1 periodaday, from the start of ON1
to theendofOFF3.
ON = continuously on.
On each side of the display there are four operating modes –
one group for central heating, the other for hot water. You can
change modes withimmediate effect by usingthe appropriate
SELECT button.Thiswon’t alter the timings in your program,
which you can return to by selecting TIMED.
on the programmer, found under the bottom flap.
Pollution degree
Software class
Ball pressure test
temperature
Rated impulse voltage
2
2
75ºC
2.5kV
E4 6 31
Salus EP101, SP120 43
NL
Myson
Myson
N L 1 3 2 4
MEPIC
4
Mictrotimer (link L-5 and 5-8) E N L 5 6
EN L 4
23
3
3 2
N L 1 2 3 4
British Gas EMT2, UT1, UT2 N L 1 324
Drayton
Drayton
Drayton
N L 1 2 3 4
N L 1 2 3 4
N L 1 2 3 4
SM1
miGenie Wish 1
MiTimeMT711R, MiTime RF Pack1
Current Models
Discontinued/Competitors’ Models
Sangamo M5 (link 1-6) N L 1 8
N L 1 2 3 4
Salus EP200, SP220
Myson MEP2C N L 1 2 3 4
Drayton
Drayton
Drayton
British Gas
SM2
miGenie Wish 2
MiTime MT721R, MiTimeRF Pack 2 & 3
EMP2, UP1, UP2
N L 1 2 3 4
N L 1 2 3 4
N L 1 2 3 4
N L 1 2 3 4
06490050 ISS F 12/02/2016 Page 1