Programmers allow you to set ‘On’ and ‘Off’ time periods.
Some models switch the central heating and domestic hot
water on and off at the same time, while others allow the
domestic hot water and heating to come on and go off at
different times.
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle.
On some programmers you must also set whether you want
the heating and hot water to run continuously, run under the
chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating pro-
gramme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These
are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched
the heating off. And, if you haveahot-water cylinder, the
water heating will not work if the cylinder thermostat detects
that the hot water has reached the correct temperature.
INSTALLATIONMUST ONLY BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR
HEATING ENGINEER.
MAKE SUREMAINS INPUT HASA3AMPFUSE.
LifestyleProgrammers and Timeswitchesconform to the
essential requirements of these Directives:
2(1) A 230V a.c. each switch
Display: blank
Time: always kept
Program times:always preserved
Fixed wiring only, to comply with
current IEEregulations
Mustbemaintained byaqualified
electrician or heating engineer
Drayton
Tempus 6,7
NL1 2 3 4
Drayton Lifestyle LP112, LP241, LP522, LP722 NL1 2 3 4
Switchmaster 400, 600 NL 4 3 1
(no connection to terminal 4 on 600)
Switchmaster 805, 900, 900i NL4 2 3 1
ACL MP (Towerchron) 21
ACL FP (Towerchron) 2 1 8 11 6 10
Tempus 3, 4, 6,7(old models),
Danfoss Randall
CP15, CP715,FP15, FP715 (Mk18
) ENL1 2 3 4
Danfoss Randall 3020P, 3060 E76 42
Danfoss Randall 4033 (link 1-6) E 7 65 3 4 2
Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 12
Danfoss Randall 701 (link L-5 and 5-6) ENL 31
Danfoss Randall 702 (link L-5 and 5-6) ENL4 2 3 1
Danfoss Randall 922, 972 (link L-2 and 2-5) ENL1 4 3 6
Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4
SET5 (link L-2 and 2-5)
Grasslin Towerchron DP 72, QE2 NL1 2 3 4
Honeywell ST 699/799 (link L-5 and 5-8) NL7 4 6 3
Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4
Honeywell ST 7100 (link L-3 and 3-6) NL7 4 8 5
Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4
H121, Tiara (link L-2 and 2-5)
Landis&Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4
252 & 270, RWB9
Myson Microtimer (link L-5 and 5-8) NL7 4 6 3
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4
(link L-5 and N-N)
Potterton Myson* Mini Minder NL1 2 3 4
Sunvic Select 207, SunPro 2000 NL1 2 3 4
Sunvic SP50, SP100 (link L-3) NL1 4 2 5
Sunvic SP20, SP35 NL 3 5 45
Venner Vennerette N L LINE LOAD
User’s Instructions
The programmer must be set to thetype of system it is to con-
trol. The link on the back of the unithastwo settings –Pand G.
P=afully pumpedand controlled system–allowing
heatingand hot water to be set separately.
G=agravity-fed hot watersystem – which does not allow
independentsetting of heating without hotwater, though
hot water can be controlledalone.
PROGRAMMER TERMINALCOMPARISONS
Current Models
Earth
Neutral
Live
Ch1 on
Chl2 on
Ch3 on
Ch4 on
MAKE MODEL
Discontinued/Competitors’ Models
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
WIRINGTHETIMESWITCH
Make the wiringconnections as
above. Note that the output
contactsarevoltage-free, so
powerneeds to be put on to
Terminal1either by linkingfrom
Terminal L or from a separate
supply with a
INTRODUCTION
Lifestyle Timeswitches will automaticallycontrolyoursystem
by switching it on and off at times that suit you. The light on the
front of the timeswitchshows when it’s on.
LP111Si–a24hr program,upto3heatingperiods
eachday, andeveryday the same.
LP711Si–a7-dayprogram, allowingfordifferent
timings on eachday of the week,upto3heating periods
eachday.
If theengineerhasn’tsetyour timingsforyou,your timeswitch
willworkwithastandardprogram that has beenset at the
factory. If this doesn’t suityou, it’s veryeasy to changeit–
whenyou’veread this introductorysection,simply turn to
the pageforyour timeswitchmodel.
Sangamo M5 (link 1-6) NL 18
NL1 2 3 4
Salus EP200, SP220
Myson MEP2C NL1 2 3 4
Drayton
Drayton
Drayton
British Gas
SM2
miGenie Wish 2
MiTime MT721R, MiTimeRF Pack 2 & 3
EMP2, UP1, UP2
NL1 2 3 4
NL1 2 3 4
NL1 2 3 4
NL1 2 3 4