Drive Medical Airial Voyager MQ5300 User manual

™
NSTRU
READ ALL INSTRUCTIONS BEFORE USELEA TODAS LAS INSTRUCCIONES ANTES DE USAR SU EQUIPO•
LISEZ TOUTES LES INSTRUCTIONS AVANT L’UTILISATION•
!
!
!ATTENTION: La loi fédérale (États-Unis) exige que cet appareil soit vendu par, ou à la
demande d’un médecin.
PRECAUCIÓN: Las leyes federales (EE.UU.) restringen la venta de este dispositivo sólo
por orden de un médico.
CAUTION: Federal (US) law restricts this device to sale by or on the order of a physician.
Portable Nebulizer
Nebulizador Portátil
Portable Nebulizer
MQ5300
MQ5500
MQ5501

2
INDEX
Page 2
Page 3
Page 3
Page 4
Page 6
Page 7
1. Introduction
2. -------------------------------------------------------
-------------------------------------------------------
--------------------------------------------------
-----------------------------------------------------------------
-----------------------------------------------------------------------
------------------------------------------------------------------
3.
4.
5.
6. Specications
Page 8
-----------------------------------------------------------------------
7. Warranty
Cleaning
Operating Your Nebulizer
Important Safeguards
Product Identication
INTRODUCTION
INSTRUCTIONS
Thank you for purchasing the Airial Voyager™ Portable Nebulizer. It is a
compact medical device designed to eciently deliver physician prescribed
medication to the bronchial lung passages. With proper care and use, it will
provide you with many years of reliable treatment.
This product is developed for the successful treatment of asthma, allergies
and other respiratory disorders. It creates a stream of air that travels through
a clear tube to the nebulizer. When air enters the nebulizer, it will convert the
prescribed medication into aerosol mist for easy inhalation.
Your Portable Nebulizer should be used under the direction of a licensed
physician and/or a respiratory therapist. We encourage you to thoroughly
read this guidebook to learn about the features of this product. Any use of
this product other than its intended use is not recommended.
1.
™
Portable Nebulizer

PRODUCT IDENTIFICATION
Note: Read all instructions carefully before use.
The following basic precautions are needed when using an electrical product:
Caution: Failure to read and observe all precautions could result in personal
injury or equipment damage.
Product cautions:
To avoid electrical shock: Keep the unit away from water. Do not immerse
the power cord or the unit in liquid. Do not use while bathing. Do not reach
for a unit that has fallen into water – immediately unplug the unit.
Never operate the unit if it has any damaged parts (including power cord),
or if it has been dropped or submersed in water. Promptly send it to a
service center for examination and repair.
1.
2.
The unit should not be used where ammable gas, oxygen, or aerosol
spray products are being used.
3.
Disconnect the unit from the electrical outlet before cleaning, lling and
after each use.
4.
Only use manufacturer recommended attachments.
5.
3
2.
IMPORTANT SAFEGUARDS
3.
Model #
MQ5500 Airial Voyager™ Portable Nebulizer with Rechargeable NiMH Battery
MQ5501 Airial Voyager™ Portable Nebulizer without Battery
Description
MQ5300 Airial Voyager™ Portable Nebulizer with Rechargeable Lithium Battery

Place cone inside
and ll medication.
4. OPERATING YOUR NEBULIZER
4
Operating Cautions:
Storage Cautions:
Cleaning Cautions:
1.
1.
Note: Prior to initial operation, the nebulizer should be thoroughly cleaned.
Only connect this product to an appropriate voltage outlet for your model.
2. Do not run this product unattended.
3. Never operate the Airial Voyager™ Portable Nebulizer if it has a damaged
cord, plug, or battery or if it has been dropped into water. If for any reason
this unit does not work properly, promptly return it to an authorized service
center for repair.
4. If any abnormalities occur, discontinue use immediately until the unit has
been examined and repaired.
5. Always unplug the product immediately after use.
6. Never block the air openings of the main unit or place it where the air
openings may be obstructed.
7. This product should always be operated under close adult supervision.
Do not store the unit under direct sunlight, high temperature or humidity.
2. Keep the unit out of reach of small children.
3. Always keep the unit unplugged while not in use.
1. Do not immerse the unit in water. It may damage the unit.
1. Place your Airial Voyager™ Portable Nebulizer on a at and stable surface. Be
sure that you can easily reach the controls when you are seated.
2. Gently twist the top part of the nebulizer cup counter-clockwise to disassemble
the nebulizer cup.
3. Fill the bottom section of the nebulizer
cup with the medication prescribed by
your physician. Be sure that the cone is
put inside the bottom section.
4. Gently twist the top part clockwise to
reassemble the nebulizer cup. Be sure
the two sections t well.
5. Attach one end of air tube to the base of the nebulizer cup.
6. Attach mouthpiece or mask per your choice to the top section of nebulizer cup.
7. Your nebulizer operates by using one of two power choices: the AC Adapter
or the Battery pack.
2. Disconnect the unit from the electrical outlet before cleaning.
3. Clean all necessary parts after each use as instructed in this guidebook.

5
Using the AC adapter:
1. Remove the battery-pack if attached. With the unit on its side and the Open/Lock
button facing up, press and hold the Open/Lock button and slide the battery
toward you to disengage. Release the Open/Lock button.
2. Replace with the rubber skid resistant base. Be sure to line up the AC port and
the space on the rubber skid resistant base.
3. Insert the adapter plug into the unit’s AC port.
4. Plug the adapter into a standard AC outlet.
5. Press power switch to begin your prescribed treatment.
1. First, remove the skid resistant rubber base.
2. Install the battery pack to the bottom of the unit. With the unit on its side and
the Open/Lock button facing up, press and hold the Open/Lock button and
slide the battery away from you to engage. Release the Open/Lock button.
3. Place the rubber skid resistant base into your carry case for storage and later
use.
4. Press power switch to begin your prescribed treatment.
Note:A red battery light shows that the battery is being charged. If the light
changes from red to green during charging, it indicates the battery is fully
charged. Once the battery is fully charged, unplug the adapter from the
battery.
Using the battery pack:
Your Portable Compressor Nebulizer can operate with the use of a rechargeable
battery when AC power is not available. The life of the battery is approximately 2
years. However, battery life will vary depending on usage, storage, and charging
conditions.
Charging the battery pack:
To charge the battery, plug the adapter into the AC Port on the Battery.
Charging Time: 2 - 4 Hours

5. CLEANING
Rinsing (after each treatment)
6
Cleaning Procedure:
(After the last treatment of the day.)
1. Prepare a solution of one part white vinegar with three parts distilled water.
2. Submerge the nebulizer cup, mouthpiece, and/or mask in the vinegar and
water solution for (30) thirty minutes.
3. After soaking the nebulizer cup and components for thirty minutes in the
prepared solution, completely rinse them under hot tap water.
4. Allow to air dry.
5. Reassemble the nebulizer cup and store the parts in a cool, dry, clean, sealed
container.
1. Wipe daily with a damp cloth.
2. Never use powdered cleaners or soap pads, which may damage the nish.
1. Disconnect the air tube, nebulizer cup, mouthpiece and mask.
2. Gently twist the nebulizer cup to open it.
3. Rinse the nebulizer cup, mouthpiece and mask with water.
4. Dry them with clean soft towel or let them air dry.
5. Reassemble the nebulizer cup when completely dry and put these parts in a dry,
sealed container.
It is recommended that the nebulizer cup, mouthpiece and mask are thoroughly
cleaned with hot water after each use and cleaned with a mild detergent after
the last treatment of the day. If your physician or respiratory therapist species
a dierent cleaning procedure, follow their instructions.
Cleaning the nebulizer unit:
1. Use only Drive Medical approved lters. Do not use cotton or any other materials.
Do not wash or clean the lter. Never operate the nebulizer without a lter.
2. Changing procedure:
A. Open the lter cover.
B. Replace the used lter with a new one.
C. Close the lter cover.
Filter Replacement:
Please utilize the following steps to thoroughly clean your nebulizer after the
last treatment of the day, unless otherwise specied by your physician.

6. SPECIFICATIONS
7
Power
Current
Battery Pack
Particle Size
MMAD
Sound Level
Medication bowl capacity
Average Nebulization Rate
Nebulizer Pressure Range
Operating Pressure Range
Liter Flow Range
Operating Temperature Range
Operating Humidity Range
Storage Temperature Range
Storage Humidity Range
Dimension (L x W x H)
Weight
Standard Accessories
4 m
60 dBA
13ml (cc)
0.2 ml/min
30 to 36 Psi (210 to 250 KPa / 2.1 to 2.5 bar)
8 to 16 Psi (55 to 70 KPa / 0.5 to 0.7 bar)
4 ~ 8 lpm
10˚C to 40˚C (50˚F to 104˚F)
10% to 90% RH
10% to 90% RH
-25˚C to 60˚C (-13˚F to 140˚F)
5-” x 3-” x 1-” without battery pack;
5-” x 3-” x 2-” with battery pack
12.5 oz. w/o battery pack
1 Lbs. 9 oz. with battery pack
Nebulizer, Air Tube, Mouthpiece, Filters (5 PCs)
Protection against electric shock
Class II Equipment
Type BF applied parts
Mouthpiece and mask
-
-
-
Protection against harmful ingress of water
Degree of safety in the presence of ammable anesthetics or oxygen
- IPX0 (Ordinary)
- No AP/APG
(Not suitable for use in the presence of ammable anesthetics or oxygen)
Lithium Iron Phosphate Battery (MQ5300)
NiMH Battery (MQ5500)
0.5 to 10 um
12V DC Adapter
1.5 A / 0.8 A
Accessory List:
Model #
1/ea
18254 Reusable Neb Kit with Mouthpiece, “T” and 7’ Tubing 10/cs
NEB KIT 500 Disposable Neb Kit with Mouthpiece, “T” and 7’ Tubing 50/cs
NEB KIT 600 Disposable Neb Kit with Medication Cup, “T”, 7’ Tubing, and Adult Mask 50/cs
NEB KIT 700 Disposable Neb Kit with Medication Cup, “T”, 7’ Tubing, and Pediatric Mask 50/cs
12/cs
18260 JetNeb Plus, Breath Enhanced Reusable Neb Kit
Description UOM
MQ5311 Rechargeable Lithium Battery
!

7. WARRANTY
8
Your Drive Brand product is warrantied to be free of defects in materials and
workmanship for 5 years of the original consumer purchaser for the nebulizer,
and 2 years of the original consumer purchaser for the battery. This device was
built to exacting standards and carefully inspected prior to shipment. This
warranty is an expression of our condence in the materials and workmanship
of our products and our assurance to the consumer of years of dependable
service.
This warranty does not cover device failure due to owner misuse or
negligence, or normal wear and tear. The warranty does not extend to
non-durable components, such as lters, rubber accessories, and rubber grips,
which are subject to normal wear and need periodic replacement.
If you have a question about your Drive device or this warranty, please contact
an authorized Drive Dealer.
Save these instructions!

www.drivemedical.com
Drive Medical
99 Seaview Boulevard
Port Washington, NY 11040
t: (877) 224-0946
f: (516) 996-4601
This manual suits for next models
2
Table of contents
Other Drive Medical Personal Care Product manuals
Popular Personal Care Product manuals by other brands

HoMedics
HoMedics spa REFLECTIVES M-6011 Instruction manual and warranty information

Fellowes
Fellowes 80309 owner's manual

Robern
Robern RECEPTION MTR installation guide

Sound Oasis
Sound Oasis BST-400 instruction manual

ELEEELS
ELEEELS Revival Hot Stone Spa S1 instruction manual

Otto Bock
Otto Bock Genu Immobil Vario T 8066 Instructions for use