DSC LC-151 Manual

1
INSTALLATION INSTRUCTIONS
&
USER MANUAL
P/N: 7131720 ver.B
LC-151
Dual-Tech Motion Sensor
(Single PIR & Microw ave)
w ith adjustable Pet Immunity

2
1 General...................................................................................................................................... 3
2 Features .................................................................................................................................... 3
3 Assembly description................................................................................................................. 4
4 Detection Pattern....................................................................................................................... 5
5 Selecting mounting location....................................................................................................... 7
6 Detector Installation................................................................................................................... 8
7 Terminal Block Connections.................................................................................................... 10
7.1 Wire Size Requirements................................................................................................... 10
8 Settings & Adjustments ........................................................................................................... 11
8.1 Detection beam direction.................................................................................................. 11
8.2 Detection beam range setting .......................................................................................... 11
8.3 Sensitivity Adjustment ...................................................................................................... 11
8.4 Indications setting............................................................................................................. 12
9 Operation................................................................................................................................. 14
10 Test procedure ....................................................................................................................................... 14
11 Accessories............................................................................................................................................. 14
12 Specifications ......................................................................................................................................... 15

3
1 General
The LC-151 is a unique motion detector utilizing a single (two elements) passive infra-red
element and Microwave technology for use outdoors in harsh environments.
The LC-151 is designed for outdoor use in the most severe and climatic conditions
and may also accommodate pets with the addition of optional pet immunity lenses.
High reliability is achieved by combining both dual tech hardware with highly sophisticated
software, greatly reducing the possibility of false alarms.
The active elements are comprised of a single (two elements) PIR and advanced Microwave
detector inside a stylish, rigid plastic body.
These special optics combined with a Microwave Doppler sensor assures elimination of “false
alarms” while maintaining high security standards for the detection of human intruders into the
protected area.
The detection sensitivity and range is controlled by a potentiometer allowing fine tuning, so that
the correct detection pattern will be set for every installation.
The LC-151 is designed to protect large areas and can easily be installed on walls in order to
provide a solid protection of the area while rejects interferences from birds and small animals due
to the optional “PET MASK” optics.
2 Features
•Microwave detection based on Doppler concept.
•N.O. & N.C. relays switched at the same time.
•Installation height is calibration free from 1.8m to 2.4m (5.9 to 7.8 ft)
•Pet Immune up to 15kg (33lb) without pet immunity lens or up to 36kg (80lb) when using
supplied LC-F1-15X pet immunity lens.
•PIR sensitivity adjustment.
•MW intensity selection.
•Temperature compensation.
•Microcontroller signal processing.
•Front and back tamper protection.
•Unique waterproof and sealed plastic design.
•Detection Range: Up to 15m (49 ft)
•Detects human intruders walking or running.
•No maintenance required.
•High RFI/EMI Immunity.
•Protection from: direct sunlight, wind up to 30 m/sec (98 ft/sec), snow and rain, small animals,
removal of top cover and removal from mounting bracket.
EN

4
3 Assembly description
The LC-151 is a robust yet small detector which includes a large LED indicator that can be easily
observed from long distances to provide indication of intrusion. Using the supplied mounting
bracket, the LC-151 can be easily mounted to walls using the provided mounting screws. For
installations requiring the detection beam to be adjusted horizontally or vertically to obtain the
desired field of protection use the LC-B1-15X Outdoor Mounting Bracket pictured below. (not
included)
LC-151 Outdoor Motion Detector LC-B1-15X Outdoor Mounting Bracket
The LC-151 consists of two detection elements:
•PIR element
•Microwave element
The following drawing shows all internal elements:
Detection LED control jumper
(Factory setting: ON)
Tamper switch
Microwave Do
pp
ler
Microwave intensity control jumper
(Factory setting: ON)
Sensitivit
y
settin
g
Detection LEDS
Terminal Connection Bloc
k

5
4 Detection Pattern
The LC-151 has a 90° top view PIR and MW detection pattern with over 15m (49 ft) detection
distance (when installed at 2.4m (7.8 ft) above the ground surface).
Standard Lens
EN

6
LC-L1-15X Corridor Lens (sold separately)
The LC-151 can differentiate between pets and human bodies and alert accordingly by
utilizing microwave movement detection combined with a PIR detection beam.
An intrusion is defined by the PIR detection beam being crossed and a microwave detection
occurring, causing an alarm.
No alarm will be generated if only the PIR detection beam is crossed or if only a microwave
detection occurs.

7
5 Selecting mounting location
The installation of the LC-151 requires a solid, level base for the mounting bracket and must be
located in a manner that when the detector is mounted, it is facing the center of the
desired detection zone.
It is recommended that the detector will face
a solid border limiting the detection area, such as the
building structure or fencing wall, to avoid undesired
detection range.
The protected area must be free from obstacles like walls,
fences, trees, ditches and other microwave detectors.
Choose a location most likely to intercept an intruder according to detection pattern on page 5.
Avoid the following Installation Locations:
•Facing direct sunlight.
•Facing areas subject to rapid temperature changes.
•Mounted at more than 10º from the vertical or horizontal plane.
•Facing metal doors.
•Near direct sources of heat or airflow.
•Clear all physical obstacles from the detection area
(e.g. plants, laundry, etc.)
•Clear all light reflecting surfaces from the detection area,
including puddles or other standing water.
•Avoid installation on the following types of ground:
Thick vegetation, Grass (un-mown), Water, Sand and Metal.
NOTES:
•Recommended installation height is 2.1m (6.8 ft).
•The PIR sensor detects motion crossing the beam; it is less sensitive detecting motion
towards the detector.
•The LC-151 performs best when provided with a constant and stable environment.
•In order to ensure suitable operation of the LC-151, the type of ground should be one of the
following: Asphalt concrete, Cement, Soil, Clay, Gravel or Grass (mown).
•Sensitivity adjustment may be required upon extreme temperature changes.
Extremely high temperature will reduce detection range.
Extremely low temperature will increase detection range.
Choose proper installation location to avoid resetting.
EN

8
6 Detector Installation
Important! Prior to installation, read both “Operation” and “Selecting the mounting location”
sections carefully.
1. Install the detector in such manner that the intruder is
most likely to cross the detection area from side to side.
2. The detector is to be installed at height of 1.8 to 2.4
meters (5.9 to 7.8 ft) , ideally 2.1m (6.8 ft)
3. Make sure to attach the metal bracket to a leveled
straight and firm wall, leaving 10cm (3.9 inches) from
the top and 10cm (3.9 inches) from both sides, for easy
installation and maintenance.
4. Placing the detector on perpendicular wall is
required for guarding a side window opening.
Alternately the LC-B1-15X Outdoor Mounting bracket
can be installed on the same wall, allowing the
detector beam to be rotated towards the window.
5. Open the detector unwinding the bottom screw.
6. Release the rear metal bracket by unwinding
internal bottom screw.

9
7. Release the detector body from the metal bracket by
pulling the detector up and out.
8. Attach the rear bracket to the wall using mounting
screws.
9. Insert wires through provided access hole and wiring
channels.
10. Attach the sealing sponge pad to the wire opening
from the rear side after the wires have been
connected and prior to final product affixing to the
mounted bracket.
11. Place the detector on the mounting bracket from top
side down and then lock the screw at the bottom.
12. If Pet immunity up to 15kg (33lb) is desired do not
install the LC-F1-15X mechanical pet filter.
If Pet immunity up to 36kg (80lb) is desired install the
LC-F1-15X mechanical pet filter.

10
7 Terminal Block Connections
Terminal 1 - Marked “+” (+12V) - Connect to a positive Voltage of 9.6 -16Vdc source
(usually from the control panel)
Terminal 2 - Marked “-” (GND) - Connect to the ground of the control panel.
Terminals 3 & 4 - Marked “TAMPER” - If a Tamper function is required connect these
Terminals to a normally closed 24-Hour Tamper Zone on the control panel.
If the top cover of the detector is opened or the detector is detached from installation wall, an
immediate alarm signal will be sent to the control panel.
Terminal 5 - Marked “EOL” - End of line – optional terminal for end of line resistors
connections.
Terminals 6, 7 & 8 - Marked “NC / C / NO” - These are the output relay contacts of the
detector. Connect to a zone input on the control panel. When an intruder is detected, alarm
relays (N.C. and N.O.) will switch for 1.8 sec.
7.1 Wire Size Requirements
Use #22 AWG or larger wires. Use the following table to determine required wire gauge and
length.
Wire Length [m] 205 310 510 870
Wire Length [ft.] 800 1200 2000 3400
Wire Gauge [#] 22 20 18 16

11
8 Settings & Adjustments
8.1 Detection beam direction
The LC-151 detection beam direction is fixed. As a result, it is recommended to
face the intrusion area with the detector.
8.2 Detection beam range setting
The detection range may be set by tilting the detector while installed using the LC-B1-15X
Outdoor Mounting Bracket. The range may vary between 5 and 15m (16ft to 49ft).
8.3 Sensitivity Adjustment
The calibration of detector sensitivity is performed by a single sensitivity potentiometer and
a Microwave intensity jumper. Changing the PIR sensitivity and microwave intensity affects
immunity to environmental noises and allows the detector to operate without nuisance
alarms in noisier environments. The microwave intensity jumper is marked with "H" (high)
and "L" (low) settings. The sensitivity potentiometer is marked with "-" to "+". Position "-" is
the minimum sensitivity and position "+" is the maximum sensitivity. The PIR sensitivity and
microwave intensity must be adjusted according to environmental conditions as follows:
Sensitivity
Potentiometer MW intensity
setting
EN

12
Environment type Potentiometer position MW jumper position
Low risk At position 5 H
Risk Between positions
3 and 4
H
High risk Between positions
4 and 5
L
Very high risk Between positions
3 and 4
L
Noisy area Between positions
2 and 3
L
Extremely Noisy area At position 1 L
Note: Adjust sensitivity according to environmental conditions!
•Low risk: very stable environment without interference from parking garages, parking
space, playgrounds, football fields, service roads, etc.
•Risk: Stable environment with some trees, bushes, flowerpots, planters, etc.
•High risk: Unstable environment with different types of vegetation and grass and
puddles.
•Very high risk: Unstable environment with winds and small pets, rats, mice, birds.
•Noisy area: Unstable environment with vegetation and water sources like swimming
pool, lake, canal, weeds as well as small pets like cats and rabbits.
•Extremely Noisy area: Very unstable environment subjected to wind, snow, rain, with
vegetation, water and large pets like dogs.
For Example:
If the detector is used in a space which contains several bushes and a swimming pool the
environmental conditions should be considered a "Noisy Area"
8.4 Indications setting
The LC-151 has 3 LEDs that each points at different indication:
1. Green LED indicates PIR detection.
2. Yellow LED indicates Microwave detection.
3. Red LED – Indicates an alarm (logic AND of both Mircowave and PIR).

13
When the LED jumper is in the "ON" position the LEDs will be active. When the LED jumper
is in the "OFF" position, the LEDs will not activate.
•Place the top cover to the base and close it using the bottom screw.
•Place the top visor in place.
Detection
LEDs
LEDs
Control jumper
(Factory setting: ON)
EN

14
9 Operation
Note! Connect the LC-151 to a positive Voltage output of 9.6 -16Vdc source.
Use only a listed power limited source.
The detector shall be provided with minimum of 4 hours of standby power from either a
listed compatible control unit or power supply.
The detector begins a 30 second warm up period once connected to power.
If the LEDs are enabled, they will sequentially flash from left to right for the duration of the 30
seconds warm up period.
Once the warm up period is complete, the detector is ready for use.
10 Test procedure
Walk Test
IMPORTANT NOTE: Once installed, the unit should be thoroughly tested to verify proper
operation and coverage. After installation, the unit should be tested annually by the
installer. The end user should be instructed on how to perform a weekly walk test.
Make sure LEDs control is set to “ON”
Ensure the detector has completed the 30 second warm up period before walk testing.
Make sure that the protected area is cleared of all people.
Create motion in the entire area where coverage is desired by walking perpendicular to the
detection pattern.
Look at the LEDs whenever motion is detected - all LEDs are turned ON.
Allow 5 sec. between each test for the detector to stabilize.
Walk across the entire area where coverage is desired. Should the coverage be incomplete,
readjust sensitivity or relocate the detector.
Once coverage is as desired the LEDs should be disabled.
11 Accessories
Device Part Number
Outdoor Mounting bracket LC-B1-15X
PIR Corridor/Long Range Lens LC-L1-15X
36kg (80lb) PET Filter LC-F1-15X

15
12 Specifications
•Specifications are subject to change without prior notice.
FCC COMPLIANCE STATEMENT
FCC ID: F5309LC151
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance with
the specifications in Subpart "B" of Part 15 of FCC Rules, which are designed
to provide reasonable protection against such interference in any residential
installation. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to television or
radio reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
· Re-orient the receiving antenna
· Relocate the alarm control with respect to the receiver
· Move the alarm control away from the receiver
· Connect the alarm control into a different outlet so that alarm control and
receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find the
following booklet prepared by the FCC helpful: "How to Identify and Resolve
Radio/Television Interference Problems". This booklet is available from the
U.S. Government Printing Office, Washington, D.C. 20402, Stock #
004-000-00345-4.
INDUSTRY CANADA COMPLIANCE STATEMENT
IC:160A-LC151
The term ‘IC:’ before the radio certification number only signifies that Industry
Canada technical specifications were met.
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
RTTE Compliance Statement:
Detection Method PIR AND MW
Microwave Frequency X-band (9.9GHz / 10.525GHz / 10.687GHz)
Power Input 9.6 to 16Vdc
Current Draw Active: 24mA (±5%); Standby: 21mA (±5%)
Temp Compensation Dual slope temperature compensation
Alarm Period 2 sec (±0.5sec)
Alarm Outputs Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm
Tamper Switch(s)
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit’s base or if base is removed from wall
Warm up Period 30sec (± 5sec)
LED Indicator
Green LED for PIR detection
Yellow LED for Microwave detection
Red LED for alarm condition
All LEDs are ON during ALARM
RF Immunity 10 V/m plus 80% AM from 80 MHz to 2GHz
ElectroStatic Immunity 6kV contact, 8kV air
Transient Immunity 1kV
Operation Temp -35ºC ~ +55ºC (-31°F ~ +131°F)
Dimensions 160 mm x 70 mm x 45 mm (6.3" x 2.7" x 1.7")
Weight 210gr. (0.45 lb)
European directives
RTTE directive:1999/5/EC
EMC directive: 2004/108/EC
Low Voltage directive: 2006/95/EC
RoHS directive: 2002/95/EC
European standards requirements:
EN300 440-2; EN301 489-1; EN50130-4 +A1 +A2; EN61000-6-3+A11
EN60950-1
EN50131-1 / EN50131-2-4 / EN50130-5
USA & Canada
47CFR part 15, subpart C, section 15.245; 47CFR part 15, subpart B
RSS210; ICES-003
Protection Degree IEC 60529: IP 65
EN

16
Limited Warranty
Digital Security Controls warrants that for a period of 12 months from the date of purchase, the
product shall be free of defects in materials and workmanship under normal use and that in
fulfillment of any breach of such warranty, Digital Security Controls shall, at its option, repair or
replace the defective equipment upon return of the equipment to its repair depot. This warranty
applies only to defects in parts and workmanship and not to damage incurred in shipping or
handling, or damage due to causes beyond the control of Digital Security Controls such as
lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse,
alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and
all other warranties, whether expressed or implied and of all other obligations or liabilities on the
part of Digital Security Controls. Digital Security Controls neither assumes responsibility for, nor
authorizes any other person purporting to act on its behalf to modify or to change this warranty,
nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls be liable for any direct, indirect or consequential
damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in
connection with the purchase, installation or operation or failure of this product.
Motion detectors can only detect motion within the designated areas as shown in their respective
installation instructions. They cannot discriminate between intruders and intended occupants.
Motion detectors do not provide volumetric area protection. They have multiple beams of
detection and motion can only be detected in unobstructed areas covered by these beams. They
cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions,
glass doors or windows. Any type of tampering whether intentional or unintentional such as
masking, painting, or spraying of any material on the lenses, mirrors, windows or any other part
of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their
effectiveness can be reduced when the ambient temperature rises near or above body
temperature or if there are intentional or unintentional sources of heat in or near the detection
area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces,
sunlight, steam vents, lighting and so on.
Warning: Digital Security Controls recommends that the entire system be completely
tested on a regular basis. However, despite frequent testing, and due to, but not limited
to, criminal tampering or electrical disruption, it is possible for this product to fail to
perform as expected.
Important Information: Changes or modifications not expressly approved by Digital Security
Controls could void the user’s authority to operate this equipment.

17
INSTRUCTIONS D'INSTALLATION
&
MANUEL DE L'UTILISATEUR
LC-151
Détecteur de mouvement à
double technologie (Élément
simple infrarouge passible et
micro-onde)
F
R

18
13 Généralités .......................................................................................................................... 19
14 Caractéristiques................................................................................................................... 19
15 Description de l'assemblage ................................................................................................ 20
16 Configuration de détection................................................................................................... 21
17 Choisir l'emplacement de l'installation ................................................................................. 23
18 Installation du détecteur....................................................................................................... 24
19 Connexions au bloc de branchement................................................................................... 26
19.1 Exigences en matière de dimension des fils .................................................................... 26
20 Paramètres et réglages........................................................................................................ 27
20.1 Direction du faisceau de détection ................................................................................... 27
20.2 Réglage de la sensibilité .................................................................................................. 27
20.3 Indications du réglage ...................................................................................................... 29
21 Fonctionnement ................................................................................................................... 30
22 Méthode d'essai................................................................................................................... 30
23 Accessoires ......................................................................................................................... 30
24 Caractéristiques................................................................................................................... 31

19
13 Généralités
Le LC-151 est un détecteur de mouvement exceptionnel qui utilise un élément simple à infrarouge
passif et la technologie micro-onde pour utilisation à l'extérieur, dans les climats rudes.
Le LC-151 a été conçu pour une utilisation à l'extérieur dans des conditions climatiques extrêmes et,
en option, on peut y ajouter des lentilles d'immunité aux animaux domestiques.
Une fiabilité élevée est réalisée en combinant les matériels des deux technologies avec un logiciel
hautement sophistiqué, réduisant grandement le risque de fausses alarmes.
Les éléments actifs sont composés d'un élément simple infrarouge passif et d'un
détecteur micro-onde avancé dans un corps élégant en plastique rigide.
Ces dispositifs optiques spéciaux combinés avec un détecteur Doppler micro-onde à la fine pointe
assurent l'élimination des « fausses alarmes » tout en maintenant un degré élevé de sécurité pour la
détection des intrus humains dans la zone protégée.
La sensibilité et la portée de la détection sont contrôlées par un potentiomètre permettant un réglage
précis de sorte que la configuration de détection appropriée est établie pour chaque installation.
Le LC-151 a été conçu pour protéger de larges zones et il peut être installé facilement sur des murs
afin de fournir une solide zone de protection tout en rejetant les interférences des oiseaux et petits
animaux grâce au dispositif optique « PET MASK ».
14 Caractéristiques
•Détection micro-onde basée sur le concept Doppler.
•Relais J.O. & J. F. commutés au même moment.
•La hauteur de l'installation ne nécessite pas de réglage entre 1,8 m et 2,4 m
•Immunisé contre les animaux domestiques jusqu'à 15 kg (33 lb) sans lentille pour l'immunité aux
animaux domestiques ou jusqu'à 36 kg (80 lb), lorsqu'utilisé avec la lentille fournie LC-F1-15X
pour l'immunité aux animaux domestiques.
•Réglage de la sensibilité PIR.
•Sélection de l'intensité micro-onde.
•Compensation de température.
•Traitement du signal par microcontrôleur
•Protection contre le sabotage avant et arrière.
•Modèle exclusif résistant à l'eau en plastique scellé.
•Détection portée : Jusqu'à 15 m
•détecte les intrus humains qui marchent ou qui courent.
•Aucun entretien nécessaire.
•Immunité aux parasites et interférences électromagnétiques.
•Protection contre: l'ensoleillement direct, le vent jusqu'à 30 m/sec, la neige et la pluie, les petits
animaux, le retrait du couvercle de dessus et le retrait du support de montage.
F
R

20
15 Description de l'assemblage
Le LC-151 est un détecteur robuste qui comporte un grand voyant DEL pouvant être facilement
observé à distance et un indicateur sonore optionnel pour indiquer une intrusion. À l'aide du
support de montage fourni, le LC-151 peut être facilement installé sur des murs à l'aide des vis
de montage fournies. Pour les installations exigeant le réglage du faisceau de détection
horizontal ou vertical pour obtenir la zone de protection désirée, utilisez le support de montage
extérieur LC-B1-15X comme illustré ci-dessous. (Non compris)
Détecteur de mouvement extérieur LC-151 Support de montage extérieur
LC-B1-15X
Le LC-151 combine deux éléments de détection :
•Élément infrarouge passif
•Élément micro-onde
Le schéma suivant montre tous les éléments internes
Cavalier de contrôle DEL de
détection
Interrupteur
antisabotage
Antenne Do
pp
ler
Cavalier de contrôle pour régler
l'intensité micro-onde
Ré
g
la
g
e de la sensibilité
DEL de détection
Bloc de raccordement des bornes
Other manuals for LC-151
1
Table of contents
Languages:
Other DSC Accessories manuals
Popular Accessories manuals by other brands

Kemo Electronic
Kemo Electronic B192 quick start guide

FrSky
FrSky FAS100S instruction manual

ROSE DISPLAYS
ROSE DISPLAYS ANOGOTCHA ROUND WITH CABLE CLIP AND CABLE AND... manual

Leedarson
Leedarson 8B-SS-ZF-H0 user manual

Baumer
Baumer PosCon OXE7 operating instructions

Lord MicroStrain
Lord MicroStrain 3DM-CV5-15 user manual