DSM Delvotest Fast Go Max User manual

User Manual
Delvotest® Fast Go Max
DSM
Alexander Fleminglaan 1 2613 AX Delft,
The Netherlands

-1 -
Contents
Introduction........................................................................................ 2
1. The Use of User Manual...........................................................................................3
2. Please Be Well-informed before Using the Product ..............................................4
Product Description .......................................................................... 8
1. Characteristics of Product ......................................................................................8
2. Product Components and Installation Methods ....................................................9
2.1.
Product Components ...............................................................................................................9
2.2.
Installation Methods.............................................................................................................. 10
3. Running Delvotest® Fast Go Max........................................................................ 12
3.1.
Instrument Registration........................................................................................................ 12
3.2.
Supervisor Registration ........................................................................................................ 13
3.3.
Log In ........................................................................................................................................... 14
3.4.
Main Menu................................................................................................................................. 15
3.5.
Test Mode .................................................................................................................................. 16
3.6.
Test Results................................................................................................................................ 19
3.7.
Manager...................................................................................................................................... 22
3.8.
Instrument Check.................................................................................................................... 28
3.9.
Thermal Printer......................................................................................................................... 30
4. Product Specification and After-sales Service ....................................................32
4.1.
Product Specification............................................................................................................. 32
4.2.
Troubleshooting and Maintenance................................................................................. 33
4.3.
Product After-sales Service................................................................................................. 33

-2 -
Introduction
Thank you for purchasing Delvotest®Fast Go Max.
In order to prevent damage or loss of property, please read instructions and safety
guidelines in this user manual and be well-informed before using this reader.
Always have this user manual at hand in case of need.
(Effective version: 1.0.10 build 20180112)
▶Copyright© all rights reserved.
▶
Delvotest® Fast Go Max
is a trademark of DSM.

-3 -
1. The Use of User Manual
Labels and symbols shown below are used throughout the user manual.
Label
Description
To indicate the direct current (DC).
CE mark –To indicate that this product is appropriate for the standard
of EU.
To indicate instruction manual.
The catalog number of this product.
The serial number of this product.
To indicate the manufacturer.
Biohazard –To indicate that biological substances may damage your
health.
Warning –To indicate that a user should read and consult accompanying
instruction.
Authorized representative in the European Community.
To indicate suitability of all in-vitro medical diagnostic equipment for
entering Europe market.
To indicate that this product should be stored within a certain
temperature range.
To indicate the date of manufacture.

-4 -
2. Please Be Well-informed before Using the Product
Precautions on Installation and Storage
(1) Appoint an administrator and let the administrator install and run this system.
An administrator should be medical professional, researcher or skilled operator with
responsibilities. If the administrator is a non-medical professional, the person is required
to keep confidentiality.
(2) Installation Method
①Check the rated voltage and connection of the power cord.
②Check the connection between the cable and the connector.
③Press power button to turn on the system.
- After the power is on, check the Power LED to see if it is working properly.
- If the system does not turn on, check the condition of the connector.
④To run the program and functions of this reader, follow test procedures guided in
this user manual. (Refer to Test Method)
(3) Cautions during Installation
①Install this product in a place where voltage, frequency and electric power
consumption are supplied appropriately.
- Use the adapter provided.
- The product may be damaged, in the case of an overvoltage or low voltage.
②Check the ground connection for grounding-type bipolar outlet.
③Be careful of reader malfunction, if there is a possible inflow of electromagnetic
waves.
④Avoid operating this reader nearby other equipment generating short waves or
CAUTION: Please read this user manual carefully and follow instructions for
installation.

-5 -
microwaves. This condition may affect the result.
⑤Check Location of Installation.
Install the reader in a place with humidity less than 90%.
Install the reader in a well-ventilated place with minimal dust.
Avoid any place where physical and chemical effect is possible.
Avoid direct sunlight.
Install the reader on a flat surface.
If room temperature is too high, an error may arise.
(Optimal operating temperature: 10~40℃)
The use of this reader with explosive, inflammable or putrefactive substances
is prohibited.
The use of this reader in a place with radiation, a magnetic field or a vacuum
is prohibited.
The use of this reader in a place with extreme electric noise is prohibited.
The Calibrator may be discolored under direct sunlight. It is recommended that
the calibrator is stored in a dark place.
Be careful not to extremely tilt or drop the reader during transfer.
Notice
This product optically analyzes the reaction between specific pathogenic organism and
reagent in the diagnostic process of specimen, and quantifies degree of the reaction
This system is for quantitative analysis of lateral flow immunochromatographic devices. The
system can be operated by a person of a non-medical field, but the result should be
interpreted and analyzed by medical professionals.
You can buy supplies like the calibrator and test devices from your supplier. Supplies should
be tested for adaptability with the system before it is actually used for the test. Information
about applicable supplies is available by contacting DSM.

-6 -
①Use this reader on a flat surface avoiding direct light.
②To prevent electric shock, check if the power supply is connected to the ground.
③Use supplies only from DSM to prevent product damage.
④Be careful not to block the air passage on the back of the reader.
⑤Be careful not to get burnt from the heat produced by the reader due to long-term
use.
⑥Do not use this reader in a place with shock and vibration.
⑦To prevent contamination of the reader, wait until all samples are absorbed into
the RDT (Rapid Diagnostic Test) device before you insert the device in the system.
⑧While you are operating the reader with the object of testing, prevent any vibrations
that affect the system.
⑨If there is any vibration affecting the system during the test, abort the process and
restart the test from the beginning.
⑩Do not open the tray during the test. If the device is exposed to the outside during
the test, abort the process and restart the test.
⑪When the test is completed, exit the program and turn off the system. If you turn
off the system before the program normally ends, it could affect the program and
unexpected errors could be generated.
⑫Be careful not to contaminate the reader when taking the device out of the reader.
Notice on Copyrights
①All rights are reserved by DSM.
②This user manual cannot be copied without permission. If it is used without
authorization, the user has to take legal responsibilities.
CAUTION: If you need an accurate result or have an important test to be done,
wait about 30 minutes after turning the system on and do the
calibration before the test (Refer to 3.2 Instrument Check).

-7 -
③We are not responsible for the damage occurred by not using appointed
standardized parts or using other software, which is not provided in the product
package.
④Specifications of this product can be changed due to company’s action for
improving convenience and product performance.
⑤You may not be compensated if it is not mentioned by manufacturer.
⑥Any problem occurred by not using equipment from the manufacturer cannot be
compensated.
⑦We are not responsible for any damage of the product caused by not following
cautions and warnings in this user manual.

-8 -
Product Description
1. Characteristics of Product
Delvotest® Fast Go Max
, gives you quantitative assessment by capturing and analyzing
images of lateral flow immunochromatography. When the Rapid Diagnostic Test (RDT)
device is inserted into the tray, an internal camera captures and saves the image, and data
is automatically collected to be converted to a graphical analysis. Accurate and reliable
rapid diagnosis is possible since this product provides quantitative analysis through highly
sensitive image analysis based on LED and the high quality image sensor. Convenient
management of patient information is also possible by saving and transporting patient
information through a USB port. And the system provides printing function using built-in
thermal printer and network printer, you can print out test result through this function.
Intuitive user interface using touch pad controller with 10”color LCD makes it easy to
access and use.
Main Features
✓Quantitative analysis of various applications for POCT
✓Remote access for support
✓1D Barcode support
Convenient Features
✓Data management
✓Data printing
✓User management
✓Patient record management

-9 -
2. Product Components and Installation Methods
2.1. Product Components
Components provided in the product package are as following.
[Figure 2.1] Product Components
Product and parts composition of
Delvotest® Fast Go Max.
▷AC/DC Adapter (12V, 5A output)
▷Power Cable
▷Touch Pen
▷Calibrator: for QC purpose only
▷User manual
※ If you have any questions or missing components, please contact DSM customer
services

-10 -
2.2. Installation Methods
CAUTION: Install this system on a flat surface. Be cautious with connection
of AC/DC adapter.
▶Product Connection
(ⅰ) Connect AC/DC adapter to the Delvotest® Fast Go Max.
(ⅱ) Connect power cable to AC/DC adapter.
(ⅲ) Put the plug in the 100-240V socket.
▶Powering On / Off
[Figure 2.2] Rear Panel
The power button is located on the top panel of the Delvotest® Fast Go Max.
After approximately one second of pressing and holding the power button, the DSM log
o appears and begins the program. Although it is advisable to use the power button on
the program to exit the reader, if the reader has a problem, push and hold the power bu
tton for more than 4 seconds to force the reader to power down.

-11 -
▶Front LED Bar
Front panel LED bar color indicates reader status. During operation, the color changes to
a different color. Depending on the color, the status is as follows :
[Figure 2.3] Front LED Bar
LED color Indication
No light No power connection.
GREEN Powered on and charging. (Adapter Operating Mode)
RED Powered on and fully charged. (Adapter Operating Mode)
RED Powered on. (Battery Operating Mode)
BLUE The measurement is in progress.
▶Battery Operating Mode
The lithium polymer battery is built-in inside of system. The purpose of the battery is for
emergency back up in case of shut down of electric power system.
The maximum operation time by battery is less than 1 hour. If the electric power is shut
down by accident, please finish the operation and save data.
Front LED Bar

-12 -
3. Running Delvotest® Fast Go Max
3.1. Instrument Registration
[Figure 3.1] Instrument Registration Page
✓Instrument Registration screen will be displayed when the analyzer is first
booted. It will not be displayed after registered.
✓Serial Number, Name, and Country are required, and you do not need to enter
anything else.
✓If the registration is successful, the message that the device has registered is
displayed.
✓When the registration is successful, the current time is set with the date and
time entered in Date / Time (H: M) field.

-13 -
3.2. Supervisor Registration
[Figure 3.2] Supervisor Registration Page
✓Supervisor Registration is displayed at the first time after analyzer registered.
It is not displayed after Supervisor registered.
✓ID, Password and Confirm(PW) are mandatory fields.
✓If Supervisor Registration succeeds, it will go to Log in screen.

-14 -
3.3. Log In
[Figure 3.3] Log in Page
✓Enter the ID and PW (Password) to log in and click the Log in button to log in
with that ID and go to the Main screen.
✓If the ID is not registered or the Password is incorrect, an error message is
displayed.
✓Click the bottom left button to display the Program Information window.
[Figure 3.4] Program Information
✓When you click the power-off button , the question "Are you sure you want
to exit program and turn off the unit?" pops up, and if you click OK button, the

-15 -
program stops and the analyzer will be halted.
3.4. Main Menu
[Figure 3.5] Main Menu
Menu
Description
Test Mode
Measurement mode
Test Reports
Manage test results (Review, Export, Backup)
Manager
Manage Operators, Samples, and Test Files (Add,
Remove, Modify)
Instr. Check
Run the Instrument Check of the analyzer and result

-16 -
3.5. Test Mode
[Figure 3.6] Test Mode Page
✓Enter Sample ID, Sample Name, and then tap the prepared barcode to
automatically enter the corresponding Kit, Lot Number, and CutOff values.
✓By clicking the Button, you can search and input the sample ID already
registered in the Sample list. Select the ID you want to enter as shown in the
image below and click the Button, then the corresponding ID is
entered in the Sample ID field in the Test Information screen.
[Figure 3.7] Search Sample Page

-17 -
✓If the test file corresponding to the input barcode has not been imported, you
cannot proceed with the test.
✓Click the button to start the measurement. When the measurement is
completed, the screen will move to the result screen as shown in the image
below.
[Figure 3.8] Test Result Page
✓Click the button and the result will be output to the built-in
printer.
✓If you click the button, you can export the result as a PDF file
by E-Mail or to the USB storage.
[Figure 3.9] Share Option
✓By clicking the button, the Export E-Mail screen will be displayed
as shown below. After entering all required fields, click the button,
then you can send E-mail with an attached PDF file.

-18 -
[Figure 3.10] Export E-Mail
✓By clicking the Button, the Export as PDF screen will be displayed as
shown below. Enter the File Name, and click the button, then a
PDF file will be saved in the ResultPDF folder of the USB memory.
[Figure 3.11] Export as PDF
✓Click the button to go to the Test Information screen again to
try a new test.

-19 -
3.6. Test Results
[Figure 3.12] Test Report Page
✓You can search and manage the test results in Test Report screen.
✓When you go to the Test Report screen, all test names in the Test folder are
added to the Kit combo box.
✓In the previous versions, test results are searched based on Kit names of Test
files. In 1.0.9 version or later, they are searched based on Test names. If you
update the analyzer from the earlier versions, please click Rebuild Database
button to regenerate test results database. (The first time you enter this screen
after updating to version 1.0.9 or later, the Rebuild Database procedure will
run automatically.)
✓Enter a Sample name in the input field to search for the
Sample Name. Clicking the button will filter the results in the list.
✓After selecting the Kit name in the to search for a Test
name. Clicking the button will filter the results in the list.
✓When you click the button, the calendar page is displayed, where you
Table of contents
Other DSM Measuring Instrument manuals