1.ProductDescription
1.1AboutSimpleAddressableSystem
Thesimpleaddressablebroadcasthostisatypeofsimpleaddressablepublicbroadcastsystemthat
integratesaddressablecontrolhost,pre-amplifying functionandfinalstagepoweramplifier,andalso
combinesterminaldecoderoraddressablespeaker.
ADR6435 isthecontrolhostofthesystem,whichiscapableofcontrolling100 zones.Thehost
employsBUSwiring pattern, andapairofpowerwireisconnectedtoeveryzone.Thewiring isvery
simpleand thezonearrangementandadjustmentrequirenochangeofline.Thezonepaginghas
optionsforindividualzone,all zonesand partialzone,andthepagingisprovidedwith
pre-conversationringingalert.
ThesimpleaddressablesystemcomposedbytheequipmentcanbecontrolledbyPC,whichcan
carryouttimingprogrammingcontrolforthissystem.
Theequipmentisprovidedwithfourlineinputportsusedforlinkingaudiofacilitiesofexternal
equipmenttobroadcastmusicprogramsforzones.Inaddition,theequipmentisalsoprovidedwith
remotepaging extensioninterface forconnectionwithremotepager.
Thesystemcomposedbytheequipmentmeetstherequirementsofthebroadcastofschools,
factories, gardens,officebuildings, shoppingmalls, stationsanddocks.
1.2FunctionFeatures
lSimpleaddressablepublicbroadcastsystem
lAddressablecontrolhostcancontrol100 zones
lSystemcomposedbytheequipmentadoptsBUSwiring,and zonearrangementandadjustment
requiresnochangeofline.
lBuilt-inpre-amplifyingfunction,andprovidedwithonemicrophoneinterfaceforconvenient
paging.
lPagerhaspre-conversationringingalert, withringingvolumeadjustable.
lBuilt-inpoweramplificationfunction,providedwith100Vconstantvoltageoutputinterface.
lTheequipmentisalsoprovidedwithfourlineinputport,onelineoutputportand onepaging
extensionport.
lProvidedwithPCextensionport, thesystemcanbecontrolledbyPC.
lProvidedwithPCcontrolsoftware, providing timingcontrolforzones
lThesystemuseshighreliablecontrolprotocolfromhosttoterminal,and supports
plug-and-play”oftheterminal.
lEnergy-savingterminalispoweredbythehostandrequiresnolocal-power.

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
3
2.BriefDescriptionofProduct
2.1DescriptionofFrontPanel
1 Powerswitch 2 powerindicator 3Resume
4 All On 5 All Off 6 Aux volume
7 MICVolume 8 MICin 9 Outputlevel
10 Rangeselect 11 Indirectselect 12 Chime
2.2DescriptionofRearPanel
1Chimevolume2Aux. Audioinput3Aux. Audiooutput
4Paginginput5PCinputjack6AC220VPowerjack
7AC220Vfuse8coolingblowerfan9Control output COM
10 Control output 100Vjack
1
9
10
11
12
2
3
4
5
6
7
8
1 2 3 4 5 7
6 8
10
9

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
4
3ExampleofSystemConnection
TAPE
Theacousticbanddecoder
TUNER RECORDER CDPLAY
Paging
Selector
TAPE TUNER RECORDER CDPLAY
Paging
Selector
DEC
DEC
Speaker
Speaker
DEC
Speaker

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
5
4.OperationDescriptions
4.1ZoneControlOperations
Thesimpleaddressablesystemcomposedbythisequipmentisprovidedwith100 zones,andthe
systemcontrolsthezonesviacontrolkeysforthezonesonthepanel.
Underdefault statusafterpower-on,thestatusindicatorlampofselectionkeyof 1~20”zonesison,
and thesystemisunderstatusofthelastshutdown.Inthiscase,thefirstzoneto20th zonecanbe
directlycontrolledbykey +1-+20”(gentlypress thezonekeyonce,iftheindicatorlampison,it
indicatesthezoneis switched-on”;gentlypressthezonekeywhentheindicatorlampison can
maketheindicatorlampgooff,andit indicatestheshutdownofthezone).Forcontrolofzones
whosenumberisabove20, pleasepress zoneselectionkeyfirst,andthenthekeyfor +1~+20”.
Controlscopefortheselectionkeyofthefivezonesareasfollows:
lZonescopeselectionkey 1~20”isusedforcontrollingthefirstto20thzones.
lZonescopeselectionkey" 21~40 " isusedforcontrollingthe21stto40thzones.
lZonescopeselectionkey" 41~60 " isusedforcontrollingthe41stto60thzones.
lZonescopeselectionkey" 61~80 " isusedforcontrollingthe61stto80thzones.
lZonescopeselectionkey" 81~100" isusedforcontrollingthe81stto100thzones.
Key ALLON”isusedforswitchingonall thezones(100 zones).Afterswitching onall thezones,
incaseofaneedtoswitchoffaparticularorcertainzones,pleaseselecttherelatedscopeofthe
zonewithzonescopeselectionkey, andthenshutoffall zonesnotrequiredwithzonecontrolkey.
Key“ALLON”isusedforswitchingoff all thezones(100 zones).Similarly, afterswitchingoff all
thezones, incaseofaneedtoswitchoncertainzones, theaboveproceduresalsoapply.
Pressingkey RESUME”makesthesystemin"resuming" status,andthesystemreadsandexecutes
thezonestatusstoredinthememory.Undernormaloperationstatusoftheequipment,prolonged
ON”statusoftheindicatorlamp relativeto RESUME”iscalledresumingstatus. Under resuming
status, thepresentstatusofall zonescanbeautomaticallystoredtothememoryoftheequipment.
4.2PlayingBackground MusicforZones
Connectaudiofacilitiesforanyofthefoursoundinputinterfacesoftheequipmentandpoweronthe
audiofacility,thenthesystemwill allocatetheaudioautomaticallytothe100 terminals.(Note:the
10 zonesonlyusesoneaudio). Among thefouraudioinputinterfaces, AUX1 haspriorityfunction.If
therearesimultaneoussignalinputforAUX1and anyoneamongAUX2, AUX3and AUX4, then
theinputsignalofAUX1 interface canautomaticallysuppress theinputsignalofotherlines.
4.3VolumeControl
Knobs AUX1VOL,AUX2VOL,AUX3VOLandAUX4VOL”on thepaneloftheequipmentare

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
6
usedtocontrolthevolumeoftheinputchannelsrespectively.Knob MICVOL”isusedtocontrol
thevolumeofmicrophone.Clockwiseturningrepresentsvolumeincrease,whileanticlockwise
turningrepresentsvolumedecrease.
Volumeofthe100 zonesisintegratedlycontrolledbytheknobonthepaneloftheequipment,i.e..
theequipmentisnotprovidedwithseparatecontrolforsimultaneousvolumeincreaseordecreasefor
the100 zones.
4.4Pagingand PriorityFunctions
Pagingincludesremotepagingandpagingofmicrophoneconnectedtotheequipment.Thecontrol
ofzonesbytheremotepagerenjoyspriorityoveraddressablehostand PCcontrolsoftware.When
thezonesareswitchedupon on theremotepagerforpaging,thefivezonescopeselectionkeyson
thepaneloftheequipmentcanbeusedtoviewtheoperationstatusofzonesduringthepaging.Any
operationoverthezonesbyaddressablehostandPCcontrolsoftwareotherthantheoperationby
remotepagerwillbeinvalid.
Whentheremotepagerisconductingpagingoperationforaparticularzone,ifthezoneisswitched
onontheremotepager,thenall thezonesforbackground musicwill beswitchedoff,thenthepaged
zonewill beswitchedon.Afterthepaging,usekey ALLOFF”onthepagertoswitchoffall the
zonesorthepowerofremotepager, and all thezoneswillresumed tothepre-pagingoperationstatus.
Whenthepagerisconductingpagingforall thezones,gentlypress ALLON”keyontheremote
pagertoswitchonall thezones.Inthiscase,theequipmentwill switchoff thezoneplaying
backgroundmusicfirst,thenswitchon all thezones.Afterthepaging,gentlypress key ALLOFF”
onthepagertoresumethestatusofplayingbackgroundmusicofthezones.
Thesystemcanalsoperformpagingoverthezonesbythemicrophoneconnectedtotheequipment.
Priortothepaging,gentlypressthekeyforringingalert”onthepaneltoobtaintheringingtone.
Ringingvolumecanbeadjustedbytheringingvolumeadjustmentknob(1)on thepanelofthe
equipment.Adjustthemicrophonevolumetotheoptimalposition (untilnohowlisavailableforthe
microphone), andthencarryoutpaging forthezones.
WhenthesystemisplayingtheaudioinputbyAUX1interface,pagingoverzonescanalsobe
performedbymicrophone.InputsignalofAUX1interface and ringingsignalarethesamepriority
signal,and theoutputterminalcantransmit three signals,any ofwhichcancovertheaudiosignal
inputbyAUX2, AUX3 andAUX4.
NoteforOperation:
1. Whenthehostisoff, atleast10 minutesisrequiredforre-energization.
2. Whenwithdrawingfromtheremotepaging(bypressingkey ALLOFF”oftheremotepager),
pleasepoweroff themicrophoneofremotepageratthesametime,otherwise,thesurrounding
soundscanstill reachthezonesswitchedon aftertheresumingviathemicrophoneofpager.

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
7
4.PrecautionsforOperation
4.1PrecautionsforSafetyOperation
lPleasedo notinsertthepowersupplyplug oftheequipmentintothepowernetworkbefore
connectingproperlythesystemcircuitry.
lItshouldbeensuredthatthevoltagesuppliedtotheequipmentbecompletelymeeting the
voltagerequirementsoftheequipment,otherwise,theremayexisttheriskofburningthe
equipment.
lDangervoltageisinsidetheequipment,andthevoltageishighenoughtoresultinthe
personnelelectricshock.Pleasedonotopenthehousingwithoutauthorization topreventthe
riskofelectricshock.
lWhenthepowerswitchoftheequipmentisat"OFF"status,themachineisnotdisconnected
completelywiththepowernetwork.Foryoursafety,pleasepull outthepowercordfromthe
socketwhentheequipmentisnottobeused.
lPleasedo notplace theequipmentatalocationtoocoldortoohot.
lEnsureagoodventilationandagood workingconditionfortheequipmenttopreventheating
intheworkinghours, otherwise, themachinemaybedamagedduetotoo highatemperature.
lThemasterpowerswitchshouldbeturnedoff atacloudydayanddampweatherorwhenthe
equipmentisnottobeusedforalongtime.
lItisrequiredtopull outthepowerplugtoensurethattheequipmentiscompletely
disengagedfromthepowernetworkwhenit istodis-assembleorre-assembleanypartofthe
equipmentortodisconnectorconnectplug ofanyelectricapparatusofequipmentormaking
otherconnection.
lWhentheequipmenthasafailure,itisnotallowedforthenon-professionalpersonnelto
openthehousing toundertaketherepairwithoutauthorization topreventaccidentor
aggravating thedamagedconditionoftheequipment.
lDonotplace anychemicalsubjectwithcorrosivityneartheequipmentoronthetopof
equipment.
4.2PrecautionsforAfter-salesService
lThecompanywillprovidefreeofchargeguaranteeservice (includingprovisionof
replacementpartfree ofcharge)foroneyeardatingfromthedayofpurchaseforany quality
probleminthenormalrangeofapplication,providedthattheinstallationandapplicationare
inconformitytothestipulationsgivenintheOperationManual.
lAtanytimefortherepairguarantee,theconsumershouldpresenttheCardofGuaranteeand
thesalesinvoice asaproof.
lThefollowingconditionsdonotbelongtothescopeforfree ofchargeservice:
(1)Productdamageduetomistakeninstallation, application orhandling;
(2)Productdamageduetoabnormalcondition(suchasoverpowervoltageorambient
humidity, etc. );
(3)Productdamageduetoforcemajeuresuchascalamityoraccident;
(4)Thenumberonproductbodyhasbeenconverted, alteredorremoved;

* FireFighting/PublicBroadcastSystem SimpleAddressableBroadcastSystem
* AddressableControlHost
8
(5)Theproducthasonce beenrepairedormodifiedbypersonnelnotauthorizedbyour
company;
lPleasekeeptheOperation ManualandCardofGuarantee carefully.
lAstothesubjectsorprecautionsnotmentionedinthemanual,pleasecontactthedistributor
orvisit thewebpageofourcompany://www.dsppa. comwhennecessary.
lPleasecontacttheservice personnelofthecompany(orthedistributor) ifthereisanyfailure
phenomenaduringtheperiodofgrantee,andthecompanyshall nottaketheresponsibilityto
repairfree ofchargeifthedamageisduetodis-assemblingbyyourselforfromtherepairby
thetechnicalpersonnelnotfromthecompany.
6.PerformanceSpecifications
1 Speakeroutput 100V
2Ratedoutput 350W
3Frequencyresponse 50Hz-16KHz(-3dB)
4Totalharmonicdistortion ≤0.5%
5S/Nratio(Aweighted) ≥80dB
Minimumpoweremf(AUX)200mV
6 Minimumpoweremf(MIC)3mV
7Lineoutput 1V
8Mutingfunction MIC、CHIME、AUX1 overridesotherinputsignals.
9Protection ACfuse ×1, overload,shortcircuit, temperature。
10
PowerSupplyRequirements AC 220 V/ 50 Hz
11
NetWeight 15.25kg
12
Gross Weight 17.3kg
13
Dimensions 430×320×125mm
Specificationsaresubjecttochangewithoutnotice.
GuangzhouDSPPAAudio Co., Ltd.
ADR6435-V1.0
Table of contents
Other DSPPA Amplifier manuals

DSPPA
DSPPA MAG6806 User manual

DSPPA
DSPPA MP6906 User manual

DSPPA
DSPPA Mini60 User manual

DSPPA
DSPPA MP 1500 User manual

DSPPA
DSPPA MP9006 User manual

DSPPA
DSPPA Alfatron ALF-250W-UB User manual

DSPPA
DSPPA MK6906 User manual

DSPPA
DSPPA MAG1306II User manual

DSPPA
DSPPA MP2708 User manual

DSPPA
DSPPA DMA6250U User manual