DST RECUSORB DR-50R User manual

7KHLOOXVWUDWLRQPD\GL௺HUIURPWKHDFWXDOSURGXFW
%LOGHQRYDQNDQVNLOMDVLJIUnQGHQOHYHUHUDGHSURGXNWHQ
$QPHUNXQJ$EELOGXQJlKQOLFK
/DIRWRJUD¿DSXHGHGL௺HUUHQWGHOSURGXFWRUHDO
/¶LPDJHSHXWGL௺pUHUGXSURGXLW
'HVLFFDQWGHKXPLGL¿HU
6RUSWLRQVDYIXNWDUH
$GVRUSWLRQVOXIWHQWIHXFKWHU
'HVKXPLGL¿FDGRUGHVHFDQWH
'pVKXPLGL¿FDWHXUSDUDGVRUSWLRQ
USER’S MANUAL
'RFXPHQWYHUVLRQ
3URGXFW
EN 2-17
SE 18-33
DE 34-49
ES 50-65
FR 66-81
EN/SE/DE/ES/FR.01 19.09
DC-5
World leaders in dehumidication

2
DC-5 EN.01Seibu Giken DST
EN
(PSW\SDJH

3
DC-5 EN.01 Seibu Giken DST
EN
Contents
1. 6DIHW\..................................................................7
1.1 Aim of this document .................................................... 7
1.2 Emphasised text ...........................................................7
1.3 Intended use ................................................................. 7
1.3.1 Hazardous operating conditions ........................ 7
1.3.2 Responsibilities of the operator .......................... 7
1.3.3 Minimising hazards ............................................ 7
1.4 Safety ........................................................................... 7
1.5 Inspection of goods ......................................................7
1.6 Safety advice regarding transportation .........................7
1.7 Installation ....................................................................7
1.8 Electrical installation .....................................................8
1.9 Operation ..................................................................... 8
1.10 Maintenance .............................................................. 8
1.11 Disposal/recycling ......................................................8
2. ,QWURGXFWLRQ .......................................................9
2.1 Type plate overview ......................................................9
2.2 Serial number structure ................................................ 9
3. 3URGXFWGHVFULSWLRQ ........................................10
3.1 Product overview ........................................................10
3.2 Applications ................................................................10
3.3 Principle of operation ..................................................10
4. ,QVWDOODWLRQ ....................................................... 11
4.1 Unit installation ........................................................... 11
4.2 General Duct work installation .................................... 11
4.3 Humidistat/electronic controller installation ................ 11
4.4 Electrical connection .................................................. 11
4.4.1 Power supply.................................................... 11
4.4.2 Humidistat connections ....................................12
5. 2SHUDWLRQ .........................................................13
5.1 General operation ......................................................13
5.2 Start-up test and adjustment .......................................13
5.3 Start ............................................................................13
5.4 Stop ............................................................................13
6. 2SWLRQDFFHVVRU\ .........................................14
6.1 Connection for an humidistat ......................................14
6.2 Process air inlet spigot ................................................14
7. 7URXEOHVKRRWLQJ ..............................................15
7.1 Capacity troubleshooting ...........................................15
8. Maintenance ....................................................16
8.1 Regular service interval ..............................................16
8.2 Washing the rotor .......................................................16
9. 7HFKQLFDOGDWD ..................................................17

4
DC-5 EN.01Seibu Giken DST
EN
(PSW\SDJH

5
DC-5 EN.01 Seibu Giken DST
EN
$SSHQGL[
1. Component list
2. Dimension
3. Electrical diagram
4. Harmful chemicals and solvents for rotors
5. CE-declaration
)LJXUHV
FIGURE 1: Type plate ..........................................................................................9
FIGURE 2: Serial number structure for a single-phase unit .................................9
FIGURE 3: Serial number structure for a three-phase unit ...................................9
FIGURE 4: Product overview ............................................................................10
FIGURE 5: Principle of operation & rotor ...........................................................10
FIGURE 6: Installation of wet air out duct ...........................................................11
FIGURE 7: Humidistat positioning .....................................................................11
FIGURE 8: Control panel ...................................................................................13
FIGURE 9: Capacity troubleshooting and solution table ....................................15
FIGURE 10: Service chart .................................................................................16

6
DC-5 EN.01Seibu Giken DST
EN
(PSW\SDJH

7
DC-5 EN.01 Seibu Giken DST
EN
1 SAFETY
1.1 AIM OF THIS DOCUMENT
This document accompanies delivery and is therefore an integral part of the
equipment. It describes the machine’s design and configuration at the time of
delivery.
In the interest of safety, please study this document before installing or operating
the equipment.
Instructions relating to safety, handling, operation and maintenance must be
followed.
Non-compliance can result in serious personal injury or damage to the machinery
and may invalidate manufacturers’ liabilities and warranties.
This document includes guidance for:
• Installers
• Operators
• 0DLQWHQDQFHVWDႇ
Please retain this document throughout the lifetime of the equipment.
1.2 EMPHASISED TEXT
Caution! Indicates hazards that could result in damage to the equipment.
:DUQLQJ Indicates ³SRWHQWLDOO\´ hazardous situations that could result
in damage to the equipment, serious personal injury or death.
'DQJHU Indicates ³LPPLQHQWO\´ hazardous situations that could result
in damage to the equipment, serious personal injury or death.
Attention! Indicates important information or instructions that require
special attention.
1.3 INTENDED USE
7KLVHTXLSPHQWLVVSHFL¿FDOO\GHVLJQHGIRUDWPRVSKHULFDLUGU\LQJ,WLVXQVXLWDEOH
for any other use. For further advice please contact a DST representative.
8QOHVVVSHFL¿FDOO\VWDWHGLQWKLVPDQXDOWKHIROORZLQJDSSOLFDWLRQVDUHSURKLELWHG
• conditioning of gases (other than air)
• conditioning of air contaminated with chemicals or aggressive elements
• FRQGLWLRQLQJRIDLUFRQWDLQLQJÀDPPDEOHRUH[SORVLYHHOHPHQWV
• in rooms or air systems having a potentially explosive atmosphere
(ATEX)
• conditioning of air at elevated pressures
• DLUHQWHULQJWKHURWRUWKDWKDVQRWEHHQSURSHUO\¿OWHUHGZLWKDWOHDVW
G4 class
• compounds in the air that will possibly deteriorate the silica gel rotor -
see appendix for detailed information
1.3.1 HAZARDOUS OPERATING CONDITIONS
Operation of the system is deemed to be hazardous if it is:
• not operated inside or is not protected within a weatherproof enclosure.
• not operated within the permitted operating parameters (see technical
VSHFL¿FDWLRQV
• operated outside the scope of ‘normal’ use (see intended use)
1.3.2 RESPONSIBILITIES OF THE OPERATOR
It is the responsibility of the operator of the system to ensure that all personnel
engaged in the installation, operation, maintenance and service of the equipment
have read and understood the relevant sections of this manual.
For your own safety, wear the appropriate personal protective equipment (PPE).
1.3.3 MINIMISING HAZARDS
To ensure that risk to personnel is minimised:
• Ensure that all activities relating to this equipment are carried out by
TXDOL¿HGDQGDXWKRULVHGVWDႇRQO\
• Identify and prevent potential safety hazards in the environment.
To ensure a failure-free operation:
• Keep this manual ready to hand with the unit.
• Use the machine as intended only.
• Only use the machine if it is fully functional.
• Check the condition of the machine before using.
• &KHFNWKHPDFKLQHIRURSHUDWLRQDOHႈFLHQF\DWUHJXODULQWHUYDOV
• Carry out maintenance and testing at prescribed intervals.
1.4 SAFETY
This equipment conforms to the relevant European regulations and directives and
is designed and manufactured to be safe and reliable in operation.
The continued safety and reliability of the supplied equipment is entirely dependent
on its correct handling, installation, operation and maintenance.
1.5 INSPECTION OF GOODS
Check for transportation damage! Use this product only if you assess it as being
undamaged and faultless. Any damage must be recorded by the forwarder at
the time of delivery and reported to the supplier of the equipment at the earliest
opportunity.
Please check the equipment carefully for damage upon receipt and after removal
of all packaging.
1.6 SAFETY ADVICE REGARDING TRANSPORTATION
:DUQLQJ2QO\XVHWHVWHGDQGFHUWL¿HGOLIWLQJHTXLSPHQWWRRႉRDGDQG
position the unit.
:DUQLQJ If a forklift is used to move the unit, please ensure the load is
evenly balanced.
1.7 INSTALLATION
Attention! Installation, testing, commissioning and maintenance must
EHFDUULHGRXWE\DTXDOL¿HGSHUVRQRUXQGHUWKHVXSHUYLVLRQRIDTXDOL¿HG
person. Wherever possible, all mechanical work must be carried out with
WKHHOHFWULFDOVXSSO\VZLWFKHGRႇ
$TXDOL¿HGSHUVRQPHFKDQLFDOLVGH¿QHGLQWKLVPDQXDODV
• DPHFKDQLFDOWHFKQLFLDQRUHQJLQHHUTXDOL¿HGWRVHUYLFHDQGPDLQWDLQ
air conditioning plant and associated systems who
• has completed the appropriate health and safety training
• has read and is familiar with the contents of this manual
• is professionally competent to commission and service this type of
equipment.
Caution! The air dryer is designed for internal installation. For external use
it will require a weatherproof enclosure.
Caution! The air dryer must be installed on a horizontal plane.
Attention! The air ducts must be vibration-free and sizable enough to
prevent pressure build-up when conveying the incoming and outgoing air
from the unit.
Attention! The incoming and outgoing outlets on the machine are not
designed to bear any weight from the air ducts system.

8
DC-5 EN.01Seibu Giken DST
EN
Attention! The wet air outlet duct must be insulated to prevent condensate
and ice build-up in cold conditions.
Caution! Due to concentrated water content in the wet air outlet duct,
LQFLGHQWDOFRQGHQVDWHPD\ÀRZEDFNLQWRWKHPDFKLQHDQGGDPDJHWKH
HTXLSPHQW,IWKHGXFWQHHGVWREHLQVWDOOHGDERYHWKHZHWDLURXWOHW¿[D
condensate drain at the lowest point of the duct, ensuring the condensate
drain does not ice up in winter.
Caution! Under no circumstances should the unit be exposed to a reverse
DLUÀRZWKURXJKWKHV\VWHP
1.8 ELECTRICAL INSTALLATION
Attention! Wherever possible, all electrical work must be carried out with
WKHHOHFWULFVXSSO\VZLWFKHGRႇ,WLVUHFRPPHQGHGWKDWHOHFWULFDOLVRODWRUV
EHORFNHGLQWKHRႇSRVLWLRQ$OOHOHFWULFDOZRUNPXVWEHFDUULHGRXWE\D
TXDOL¿HGSHUVRQRUXQGHUWKHVXSHUYLVLRQRIDTXDOL¿HGSHUVRQ
$TXDOL¿HGSHUVRQHOHFWULFLDQLVGH¿QHGLQWKLVPDQXDODV
• DQHOHFWULFDOWHFKQLFLDQRUHQJLQHHUTXDOL¿HGWRVHUYLFHDQGPDLQWDLQDLU
conditioning plants
• has completed the appropriate health and safety training
• has read and is familiar with the contents of this manual.
'DQJHU If working on the unit’s isolation switch, ensure that the plug is
unplugged from the electrical grid to prevent accidental resetting.
'DQJHU Electrical connections are to be made in accordance with local
regulations.
Attention! Check that the incoming electrical supply conforms to the
electrical wiring diagram and the manufacturer’s type plate attached to
the unit.
Caution! Parameters used in the electrical protection and alarm circuits
PXVWQRWEHPRGL¿HGRUDGMXVWHG)DFWRU\GHIDXOWSDUDPHWHUVDUHVKRZQ
in the electrical wiring diagrams, technical data or parameter list.
:DUQLQJ This equipment will contain high voltage electrical components!
1.9 OPERATION
Caution! On no account should the unit be operated without air filters
installed!
Caution! Do not expose the unit to an ambient temperature that exceeds
50 °C/122 °F (e.g inside a plant room) for a long period of time. This may
damage the internal components!
Caution! Do not process air at a temperature higher than 40°C/104°F. This
may damage the internal components!
'DQJHU'RQRWDOORZWKHGLUHFWLRQRIUHJHQHUDWLRQRUSURFHVVDLUÀRZWREH
reversed during operation or non-operation. Install a one-way damper or
other preventive measures if necessary!
1.10 MAINTENANCE
Caution! Defective electrical components and defective wiring must be
replaced immediately. The equipment must not be operated until the defect
has been repaired and the unit has been retested.
Attention! Advise all operating and maintenance personnel of the
automatic restart function if applicable.
Attention! Pay attention to accessibility requirements for maintenance and
service purposes.
Caution! The operation of all electrical safety devices is to be checked at
commissioning and during service/maintenance. Under no circumstances
are these devices to be deactivated (e.g., during adjustment or bridging).
Caution! Do not expose the unit to water jets during the washing-down
procedure!
Caution! Do not wash the rotor!
:DUQLQJ Allow the fans to come to a complete stop and the unit to be
isolated from the electrical supply before removing any panels!
:DUQLQJ The unit is equipped with a heating element. Do not touch the
equipment whilst it is hot. Allow the unit to cool for at least 15 minutes before
any service or maintenance is performed.
1.11 DISPOSAL/RECYCLING
When the unit is no longer in use, dismantle the unit and recycle the components
according to local regulations. Contact a DST representative if you have any
questions.

9
DC-5 EN.01 Seibu Giken DST
EN
2 INTRODUCTION
2.1 TYPE PLATE OVERVIEW
7KHPDQXIDFWXUHGXQLWLVLGHQWL¿HGE\DW\SHSODWH7KHW\SHSODWHLVSRVLWLRQHGRQIURQWRUWKHULJKWVLGHRIWKHXQLW7KHGHWDLOVRQWKHW\SHSODWHDUHVHWRXWDVIROORZV
1. Model designation
2. Serial number
3. Electrical supply information
4. Regeneration heater power
RECUSORB DR-50R
Nr DR-50R.0000XXX
Electric heater P nom 4 kW
3 x 400V ~ 50Hz
P motors 0.23kW
P tot 4.3 kW
I tot 10 A
Seibu Giken DST AB
Avestagatan 33
16353 SPÅNGA, Sweden
),*85( 7\SHSODWH
2.2 SERIAL NUMBER STRUCTURE
7KHVHULDOQXPEHUSULQWHGRQWKHW\SHSODWHLVFRPSRVHGRIFRGHVWRHQDEOHDIDVWLGHQWL¿FDWLRQRIWKHXQLW8QLWVPDQXIDFWXUHGSUHXVHDPRGL¿HGVHULDOQXPEHUVWUXFWXUH
which does not match the current structure.
Nr DR-50bb.000cddd
),*85( 6HULDOQXPEHUVWUXFWXUHIRUDVLQJOHSKDVHXQLW
Nr DR-50abb.000cddd
),*85( 6HULDOQXPEHUVWUXFWXUHIRUDWKUHHSKDVHXQLW
1. Model designation
2. Regeneration heater (a) - the type of heater the unit is equipped with.
R = Resistive (electric)
G = Ga s
S = Steam
HW = Hot water
WW = Warm water
D = Diesel
O = Oi l
3. Special unit (EE) - code to indicate a special manufactured unit
SP = Special
1RWH The absence of SP indicates a standard manufactured unit; e.g. DR-50RSP is a special manufactured unit, and DR-50R is a standard manufactured unit.
4. Serial number (c) - to indicate whether the unit belongs to a special or standard manufactured series
0 = Standard manufactured series
7 = Special manufactured series
5. Serial number (ddd) - serial number of the manufactured unit (ddd)
001, 002, 003, 004...

10
DC-5 EN.01Seibu Giken DST
EN
3 PRODUCT DESCRIPTION
3.1 PRODUCT OVERVIEW
2
1
7
4
3
65
1. 3URFHVV¿OWHU
2. Process air in
3. Control panel
4. Wet air out
5. Regeneration air in
6. Dry air out
7. 5HJHQHUDWLRQ¿OWHU
),*85( 3URGXFWRYHUYLHZ
9DULDWLRQRILQVWDOODWLRQDQGFRPSRQHQWVPD\YDU\
3.2 APPLICATIONS
DST desiccant-type dehumidifiers are normally used where dry air is essential to the various manufacturing processes used in chemical, pharmaceutical, food or
confectionery industries, or where a dry environment is required for the storing and handling of moisture-sensitive products and raw materials.
7KHZHOOSURYHQDLUGU\LQJWHFKQRORJ\XVLQJWKHDGVRUSWLRQSULQFLSOHSURYLGHVJUHDWÀH[LELOLW\LQVROYLQJKXPLGLW\SUREOHPV,WRႇHUVWKHXVHULQGHSHQGHQWKXPLGLW\FRQWURO
GRZQWRGHZSRLQWVIDUORZHUWKDQWKHHႇHFWLYHRSHUDWLQJUDQJHRIUHIULJHUDWLRQGHKXPLGL¿HUV
3.3 PRINCIPLE OF OPERATION
,WZRUNVRQDFRQWLQXRXVSURFHVVZLWKWZRDLUVWUHDPVRIGLႇHUHQWÀRZUDWHVQRUPDOO\KDYLQJDÀRZUDWLRRIDSSUR[LPDWHO\7KHJUHDWHUÀRZSURFHVVDLU is dried as it
SDVVHVWKURXJKWKHGHKXPLGL¿HUZKLOHWKHVPDOOHUÀRZregeneration air, is used to heat the rotor material to evaporate the adsorbed moisture vapour from the desiccant. The
moisture which is removed from the process air, is transferred over to the other sector as the rotor turns slowly.
Hot air with low
relative humidity
Warm air with
high humidty
1. Wet air outlet
2. Regeneration sector
3. Regeneration heater
4. Regeneration air fan
5. Regeneration air in
6. Dry air outlet
7. Rotor motor
8. Process sector
9. Rotor
10. Process air fan
11. Process air inlet
11
1
4
7
10
6
35
9
2
8
Humid air Dry air
Water molecules
Silica gel micropores
adsorb the water molecules
CONSORBLVDFRQWLQXRXVGHKXPLGL¿HUDEOHWRUHDFKYHU\ORZGHZSRLQWV7KHURWRULVGLYLGHGE\VHDOVLQWRWZRVHSDUDWHDLUVHFWRUVSURFHVVDQGUHJHQHUDWLRQ7KHSURFHVV
DLULVGULHGE\DGVRUSWLRQLQWKHSURFHVVVHFWRU7KHUHJHQHUDWLRQDLULV¿UVWKHDWHGE\WKHUHJHQHUDWLRQKHDWHUEHIRUHLWÀRZVLQWRWKHUHJHQHUDWLRQVHFWRUZKHUHLWHYDSRUDWHV
WKHDGVRUEHGPRLVWXUHYDSRXUDQGGULYHVLWRXWRIWKHURWRU
),*85( 3ULQFLSOHRIRSHUDWLRQURWRU

11
DC-5 EN.01 Seibu Giken DST
EN
4 INSTALLATION
4.1 UNIT INSTALLATION
)ROORZWKHGLUHFWLRQUHJDUGLQJLQVWDOODWLRQRIVLQJOHSKDVHGHKXPLGL¿HUV
1RWHUse the installation guidelines as a reference only.
4.2 GENERAL DUCT WORK INSTALLATION
7KHJXLGHOLQHVDUHWRDVVLVWWKHLQVWDOOHUVDQGRSHUDWRUVWRDGMXVWWKHGXFWGHKXPLGL¿HULQVWDOODWLRQ&RQVXOWD'67UHSUHVHQWDWLYHRUORFDOPHFKDQLFDOLQVWDOODWLRQFRPSDQ\
for more information.
• $YRLGUHFLUFXODWLRQIURPWKHVHSDUDWHDLUÀRZVGLUHFWHQWHULQJDQGH[LWLQJDLUÀRZDZD\IURPHDFKRWKHU
• &KHFNLIWKHGU\DLULVZHOOGLVWULEXWHGLQWKHGHKXPLGL¿HGDUHD
• 7KHUHJHQHUDWLRQDLULQDQGZHWDLURXWKDVWREHFRQQHFWHGWRWKHRXWVLGHRIWKHGHKXPLGL¿HGDUHDSUHIHUDEOHRXWGRRU
• 7RLQFUHDVHWKHOLIHWLPHRIWKH¿OWHULWLVUHFRPPHQGHGWDNLQJDLUIURPDKLJKHUOHYHOZKHUHGXVWDQGRWKHUSDUWLFOHVDUHNHSWDWPLQLPXP
• Install dry air out duct/channel at a high level.
• 7RPD[LPL]HWKHGU\LQJFDSDFLW\IUHHEORZLQJRQGU\DLURXWZLWKRXWDLUÀRZUHGXFWLRQLVUHFRPPHQGHG
• $OORZZHWDLUWRGLVSHUVHIUHHO\ZKHQH[LWLQJWKHGXFW
• ,WLVUHFRPPHQGHGWRLQVXODWHWKHZHWDLUGXFW
• 7KHZHWDLUGXFWPXVWEHLQVWDOOHGDWDVORSLQJRXWZDUGVDQJOHGXHWRULVNRIFRQGHQVDWLRQLQVLGHWKHGXFWZRUN7KHVHWXSZLOODOVRSUHYHQWFRQGHQVDWLRQÀRZLQJEDFN
LQWRWKHGHKXPLGL¿HU
• ,IWKHGXFWQHHGVWREHLQVWDOOHGKLJKHUWKDQWKHZHWDLURXWOHW¿[DFRQGHQVDWHGUDLQDWWKHORZHVWSRLQWRIWKHGXFW
• 'RQRWFRQQHFWWKHDLURXWOHWWRDYHQWLODWLRQV\VWHPZKLFKFDQFUHDWHSUHVVXUHWKDWZLOOUHVXOWLQUHYHUVHDLUÀRZWKURXJKWKHGHKXPLGL¿HU
1$IRU'57
1$IRU)DQG$4
$6ORSHRXWZDUGV
%/RZHVWSRLQW
C) Insulation
'1HW
E) Wet air
),*85( ,QVWDOODWLRQRIZHWDLURXWGXFW
4.3 HUMIDISTAT/ELECTRONIC CONTROLLER INSTALLATION
Install the humidistat/electronic controller away from the dry air out path to avoid false readings.
;
:
),*85( +XPLGLVWDWSRVLWLRQLQJ
4.4 ELECTRICAL CONNECTION
Electrical components should be connected to the supply according to the local regulations and requirements.
4.4.1 POWER SUPPLY
The single-phase cable is to be directly connected to the power grid with earthing capability.
See electrical diagram for a electrical voltage and operation frequency.

12
DC-5 EN.01Seibu Giken DST
EN
4.4.2 HUMIDISTAT CONNECTIONS
7KHGHKXPLGL¿HUKDVDFRQQHFWLRQIRUDVWHSRUVWHSKXPLGLVWDW7KLVLVRSWLRQDOIRUVRPHPRGHOV
See electrical diagram for connections.
)RUPRGHOVZLWKQRVHOHFWDEOHKHDWHURXWSXW
)RUPRGHOVZLWKDWOHDVWWZRVHOHFWDEOHKHDWHURXWSXW

13
DC-5 EN.01 Seibu Giken DST
EN
5 OPERATION
5.1 GENERAL OPERATION
7KHGHKXPLGL¿HULV¿WWHGZLWKDQLQWHJUDWHGFRQWUROSDQHOZLWKSRZHUVZLWFKPRGHVZLWFKDQGLIDSSOLFDEOHDFRQQHFWLRQIRUDQH[WHUQDOKXPLGLVWDW
The mode switch has two operation modes.
• Manual (MANPRGH7KHXQLWUXQVXQWLOPDQXDOO\WXUQHGRႇ
• Automatic (AUTOPRGH7KHXQLWLVFRQWUROOHGE\DVHWSRLQW,WVWRSVWKHGHKXPLGL¿FDWLRQZKHQWKHFRQWUROVHWSRLQWKDVEHHQDFKLHYHG7KHXQLWDXWRPDWLFDOO\
UHVXPHVRSHUDWLRQZKHQWKHPHDVXUHGYDOXHLVDERYHWKHFRQWUROVHWSRLQW$KXPLGLVWDWLVUHTXLUHGWRRSHUDWHWKHXQLWLQDXWRPDWLFPRGH$GGLWLRQDOVHWWLQJVDUH
available in auto-mode.
2SWLRQ
Caution!
$XWRPDWLFFRQWUROVKRXOGQRWEHXVHGLIWKHXQLW¶VH[SHFWHGUXQQLQJF\FOHVDUHOHVVWKDQWZRPLQXWHV
5.2 67$57˨837(67$1'$'-8670(17
1. Inspect and clean the inside of the unit from foreign objects such as rags, tools, particles of metal, and such, that may pose damage to the inside of the unit.
2. If any, ensure that both air balance dampers are open and check that the air paths of the duct work are not obstructed in any way.
3. &KHFNWKDWWKH¿OWHUVDUHVHFXUHO\LQSODFH
4. Check and, if needed, reduce the electrical consumption to the recommended . See ³,QVWDOODWLRQ´ and see heater current in ³7HFKQLFDOGDWD´.
5. If applicable, check that the rating of the electrical supply fuses is correct, see wiring diagram.
5.3 START
1. Switch MAN/AUTO [3] t o ³0$1´ (AUTO-mode can only be used if a humidistat is connected).
2. Switch ON/OFF [2] to ³21´.
3. $GMXVWWKHDLUÀRZVE\WULPPLQJWKHGDPSHUVLQWKHGXFWV\VWHPVIRUGU\DLUDQGZHWDLUUHVSHFWLYHO\
5.4 STOP
1. Switch ON/OFF [2] to ³2))´.
1. Elapsed time meter
2. ON/OFF
3. MAN/AUTO
4. +XPLGLVWDWSOXJ
5. Electrical cable
2SWLRQ
1
2
4
3
5
),*85( &RQWUROSDQHO

14
DC-5 EN.01Seibu Giken DST
EN
6 OPTION & ACCESSORY
6.1 CONNECTION FOR AN HUMIDISTAT
,QVWDOOLQJDDPSKHQROFRQQHFWRUZLOOPDNHLVSRVVLEOHWRFRQQHFWDKXPLGLVWDWDQGUXQWKHXQLWRQDXWRPDWLFGHKXPLGL¿FDWLRQ
It is recommended to also select a humidistat.
6.2 PROCESS AIR INLET SPIGOT
The unit comes with a grated process air inlet cover. This part is interchangeable, and if needed, change the grated cover with a single or a dual spigot inlet attachment for
duct connection.
1RWHDual spigot attachment is available for CS-5L only.
1RWH,QVWDOOLQJDVSLJRWZLOODႇHFWWKHFDSDFLW\GHSHQGLQJRQWKHFRQGLWLRQV

15
DC-5 EN.01 Seibu Giken DST
EN
7 TROUBLESHOOTING
7.1 CAPACITY TROUBLESHOOTING
7KHGHKXPLGL¿HUSHUIRUPDQFHFDQEHURXJKO\FKHFNHGE\IHHOLQJWKHWHPSHUDWXUHRIWKHXQLQVXODWHGGXFWZRUNQHDUWKHXQLW
Normally with the unit working at nominal conditions (with process air at room temperature), the dry air duct should be warm (25-40°C) and the wet air duct should be warm or
hot (30-60°C). If the unit does not maintain the required condition, check table below.
PROBLEM OBSERVATION SOLUTION
7KHGHKXPLGL¿HUGRHVQRW
maintain required condition or
achieve expected performance,
despite being operated at full
power.
Dry air outlet duct is warm and wet air outlet
duct is very warm (normal operation).
Check actual moisture load against calculated design moisture load.
Check controller set point/output signal.
&KHFNDLUÀRZVDUHVHWDVVSHFL¿HGDGMXVWDVQHFHVVDU\
&KHFNDLU¿OWHUV
&KHFNGHKXPLGL¿HUFDVLQJDQGGXFWZRUNIRUDLUOHDNDJH
Check rotor alignment and condition of radial and peripheral rotor seals.
Both outlet air ducts are cold (no alarm).
&KHFNUHJHQHUDWLRQDLUÀRZDQGIDQRSHUDWLRQ
Check regeneration heater operation.
Check controller set point/output signal.
Dry air outlet duct is cold, wet air outlet duct is
hot (no alarm).
Check rotor rotation.
&KHFNSURFHVVDLUÀRZDQGIDQRSHUDWLRQ
0HDVXUHGDLUÀRZVDUHORZHUWKDQ
VSHFL¿HG In or outlets are blocked. Open dampers or remove blockage.
),*85( &DSDFLW\WURXEOHVKRRWLQJDQGVROXWLRQWDEOH

16
DC-5 EN.01Seibu Giken DST
EN
8 MAINTENANCE
8.1 REGULAR SERVICE INTERVAL
(YHU\PRQWKV (YHU\PRQWKV
Filter &OHDQWKH¿OWHUKRXVHDQGFKDQJH¿OWHU &OHDQWKH¿OWHUKRXVHDQGFKDQJH¿OWHULIQHFHVVDU\
General Inspect the dehumidifer for any internal and external physical
damage. Clean the unit internally and externally if needed.
,QVSHFWWKHGHKXPLGL¿HUIRUDQ\LQWHUQDODQGH[WHUQDOSK\VLFDOGDPDJH
Clean the unit internally and externally if needed.
Belt system Check the tension in the timing belt and, if needed, adjust it.
Fan/s and rotor motor Check rotor and fan/s for damage. Clean and, if any, retighten the screws.
Check cables for possible damages and any sign of overheating.
Rotor and, if any, seals Check if the rotor is undamaged and free from particles that
may clog the matrix. If any, clean and remove dust and other
foreign objects from the rotor.
Check seals for any damages and any wear, replace if
necessary.
Check if the rotor is undamaged and free from particles that may clog the
matrix.
If necessary, clean and remove dust and other foreign objects from the rotor.
Check seals for any damages and wear, replace if necessary.
Electrical component,
cables and terminal
Check if all cables, electrical component and terminal are secured and for
any damages or wear.
Check gauges and adjust if necessary.
Mode &KHFNWKHDYDLODEOHGHKXPLGL¿FDWLRQPRGHV212))0$1$87221
VENT, ON/OFF or both) and humidistat operation. Auto-mode in MAN/
AUTO can only be used if a humidistat is installed.
Regeneration heater Check if cables connected to the heater is undamaged.
Remove any foreign objects on top and underneath the heater.
The compartment should rest lightly on the rotor using only the springs
(applies for units without seals).
Air duct connection Check if ducts are seals, internal condensation and correct installed. Clean
the ducts if necessary.
+XPLGLVWDWLI¿WWHG Check if the humidistat is working properly and calibrate it or change if
necessary.
),*85( 6HUYLFHFKDUW
7KLVLVDJHQHUDOVHUYLFHFKDUWDQGWKHWLPHLQWHUYDOYDU\GHSHQGLQJRQWKHRSHUDWLQJFRQGLWLRQ6RPHRSWLRQVOLVWHGKHUHPD\QRWEHLQVWDOOHGRUDYDLODEOHIRUWKLVVSHFL¿FXQLW
'DQJHU
$OOSHUVRQQHOLQYROYHGZLWKLQVWDOODWLRQRSHUDWLRQDQGPDLQWHQDQFHRIWKLVXQLWVKRXOGIDPLOLDULVHWKHPVHOYHVZLWKWKHVDIHW\VHFWLRQRIWKLVPDQXDO
8.2 WASHING THE ROTOR
The D-MAX rotor has a distinct advantage over other types of desiccant rotors in that dust and grease can be washed out of the material without the need for reimpregnation
after treatment. In all normal applications however it must be emphasised that washing of the rotor should be considered as a last resort having alleviated all other possible
GHIHFWV¿UVW
Caution!
3OHDVHFRQWDFWD'67UHSUHVHQWDWLYHEHIRUHDWWHPSWLQJWRZDVKWKHURWRU

17
DC-5 EN.01 Seibu Giken DST
EN
9 TECHNICAL DATA
9DOLGIRULQOHWFRQGLWLRQV&5+HTXDOWRNJP
,IQRGDWDLVVWDWHGKHUHWKHYROXPHÀRZDERYHLVJLYHQDWIUHHEORZLQJDLUÀRZ
7KHKHDWLQJRXWSXWRIWKH37&KHDWHULVFRQWUROOHGGHSHQGLQJRQWKHZHWDLUÀRZ
8QLWFRQQHFWHGWRXQLQVXODWHGGXFWV1RPLQDODLUÀRZV
7KHFXUUHQWSURYLGHGE\WKHKXPLGLVWDWFRQQHFWLRQ2QO\XVHKXPLGLVWDWVWKDWDUH
FDSDEOHRIWKLVORDGFXUUHQW
7KHFRQWHQWRIWKLVGRFXPHQWPD\EHVXEMHFWWRFKDQJHZLWKRXWSULRUQRWLFH)RU
TXHVWLRQVDQGFRPPHQWVUHJDUGLQJWKHFRQWHQWRIWKLVGRFXPHQWSOHDVHVHQGLWWR
6HLEX*LNHQ'67$%$77'RFXPHQWDWLRQ$YHVWDJDWDQ63c1*$
6:('(1
(PDLOLQIR#GVWVJFRPVXEMHFW'RFXPHQWDWLRQ
&DSDFLW\
Capacity [kg/h] 1) 0.5
1RPLQDOGU\DLUÀRZ>PK@ 120
External static pressure dry air [Pa] 2) 50
1RPLQDOZHWDLUÀRZ>PK@ 40
External static pressure wet air [Pa] 2) 30
7RWDOSRZHU(OHFWULFDO
Total motor power [kW] 0.04
Total power [kW] 1.06
Total amperage [A] 4.6
2WKHUHOHFWULFDOLQIRUPDWLRQ
Supply fuse 230V/ 50Hz [A] 10
Electric compartment protection class IP44
Humidistat connection 230V
Humidistat supply current [A] 5) 10
2WKHUWHFKQLFDOGDWD
$LU¿OWHUFODVVUHJHQHUDWLRQSURFHVV G4/G4
Weight [kg] 10
Noise level [dB(A)] 4) -

18
DC-5 SE.01Seibu Giken DST
SE
Tom sida

19
DC-5 SE.01 Seibu Giken DST
SE
Innehåll
1. 6lNHUKHW ...........................................................23
1.1 Syfte med denna dokumentation ................................23
1.2 Anvisningar i texten ....................................................23
1.3 Avsedd användning....................................................23
1.3.1 Felaktiga arbetsförhållanden ...........................23
1.3.2 Användarens ansvar ........................................ 23
1.3.3 Minskning av risker ...........................................23
1.4 Säkerhet .....................................................................23
1.5 Inspektion av godset. ..................................................23
1.6 Säkerhetsråd avseende transport ..............................23
1.7 Installation ..................................................................23
1.8 Säkerhetsråd avseende elsystem .............................24
1.9 Drift .............................................................................24
1.10 Underhåll ..................................................................24
1.11 Demontering och återvinning ...................................24
2. ,QWURGXNWLRQ .....................................................25
2.1 Typskyltöversikt..........................................................25
2.2 Serienummerstruktur .................................................25
3. 3URGXNWEHVNULYQLQJ ........................................26
3.1 Produktöversikt ..........................................................26
3.2 Användning ................................................................26
3.3 Arbetsprincip ..............................................................26
4. ,QVWDOODWLRQ .......................................................27
4.1 Generell aggregatinstallation .....................................27
4.2 Kanalinstallation .........................................................27
4.3 Hygrostat/Elektronisk fuktregulator installation .......... 27
4.4 Elektriskt matning .......................................................27
4.4.1 Strömförsörjning ..............................................27
4.4.2 Hygrostatanslutning .........................................28
5. ,GULIWWDJDQGH ....................................................29
5.1 Generell driftinformation .............................................29
5.2 Innan igångkörning .....................................................29
5.3 Start ............................................................................29
5.4 Stop ............................................................................29
6. 7LOOYDOWLOOEHK|U ..............................................30
6.1 Hygrostatuttag............................................................30
6.2 Processluft in stos.......................................................30
7. )HOV|NQLQJ .......................................................31
7.1 Kapacitetsfelsökning ..................................................31
8. 8QGHUKnOO ..........................................................32
8.1 Regelbunden serviceomgång ....................................32
8.2 Tvättning av rotor ........................................................32
9. 7HNQLVNGDWD .....................................................33