dtm EasyRX 868 User manual

GENERALINFORMATION
EasyRX 868 radio card is designed for EASY gate controllers. EasyRX 868 radio receiver card is compatible with
DTM868MHztransmitters.
TECHNICAL DATA
4designedfor EASY gatecontrollers;
4easyremote registering withoutneed to usereceiver button;
4verifyingnumber of registeredremotes;
4IRScoding system;
4superheterodynereceiver,frequency 868 MHz;
4memoryup to 200remotesDTM868MHz series;
4powersupply via gatecontroller connector;
4workingtemperature-20°C/ +55°C;
4dimensions 55 40 13.[mm]: x x
RADIO CARD FOR EASY GATE CONTROLLER
EasyRX 868
installatio n manual v. 1.0
Fig.1 EasyRX 868 view.
channel A button
antenna connector
card connector
channel B button
channel C button
channel A LED
channel B LED
channel C LED
1. Installation
Start with antenna connection. Next
plug EASYRX card into RADIO-marked connector located on
the control board (4 pins). To EASY232 controller plug
EASYRX868 card in the direction of regulatory potentiometers.
To EASY231 controller plug EASYRX868 card in the direction of
low-voltageconnectors.
2. Programming
2.1. Remote registering
Receiver has three identically programmed A, B and C
channels analogue to OPEN A, OPEN B and OPEN C inputs in
gatecontroller.
Toregister any buttonto first channel:
4pushand hold channelAbutton;
4while holding channel A button press choosen remote
button;
4channelALED blink- registering completed;
4releasechannelA button.
To register to second B and third C channel proceed in the same
wayas for firstchannel using correctbuttons.
Caution!
4registering another button does not erase previously
registered button;
4attempt of registering into memory 201 transmitter will
fail. LED will not blink.
2.2. Easy remote registering
Easy remote registering function allows registering
newremotes without accessto receiverbutton.
Previouslyregistered remote isneeded.
a) press and hold for 15 seconds previously registered
remotebutton, relase button;
b) in no more than 3 seconds press and hold new
remotebutton for 15seconds;
c) new remote is registerd with the same active button
asinthe previouslyregistered remote.
Caution!
Failure in registering may be caused by low batteries, radio interferences or full memory of the receiver.
2.2.1. Easy remote registering function LOCK / UNLOCK
To protect receiver against unauthorized attempts of registering remote (important in access protected user zones)
easyremote registering functionmust be locked.
To lock/unlock easy remote registering function press simultaneously A and B buttons on the card. Then release one
button. LEDs A and B will light up alternately every 4 seconds. To lock/unlock easy remote registering release second button
when:
4LEDA- easyremote registering lock;
4LEDB - easyremote registering unlock.
Fig.2 Installing EasyRX 868 card into EASY gate controller.
Fig.3 Remote button programming.
Fig.4 Easy remote registering.
PRESS ANY BUTTON OF
"OLD" REMOTE FOR 15
SECONDS
BREAK TIME
MAX 3 SECONDS
TIME
11 2
PRESS ANY BUTTON OF
"NEW" REMOTE FOR 15
SECONDS
2
11
+PRESS ANY BUTTON
OF "NEW" REMOTE
PRESS AND HOLD
A, B or C BUTTON
spółka z ograniczonąodpowiedzialnościąspółka komandytowa
2.3.Single remote removing form receiver memory
While holding receiver button press active button on the
remote.If valid removalLED fade.
Caution!
Holding receiver button for more than 15 seconds will erase
memory
2.4. Changing buttons registration to channel
4remove remote from memory (see section 2.3.)
4register remote according to section 2.1. or 2.2.
2.5.All remotes removing
To remove all remotes from receiver memory press and
hold receiverA and B buttons for 15 seconds. Release button when
LEDfade.
Memory format unlock easy remote registering
function.
2.6. Verifying number of registered remotes
To verify number of registered remotes prior registering
orremovingremote isrequired.
After registering or removing remote hold receiver button for 5
more seconds. LED will blink showing number of registered
remotes. First number of tens (from 0 to 20 long pulses) then
numberof units (from0 to 9short pulses).
Fig.5 Lock disabled/enabled
Fig.6 Single remote removing.
Fig.7 All remotes removing.
lock disabled 4a lock enabled
4b
13
113
2
1
1
13
3
lock disabled
lock enabled
1
2
...press remote button
while holding
A and B
button...
press and hold
min. 15 seconds
Fig.8 Pulses example showing number of registered remotes - 46.
number of tens - 4x10 number of units - 6
spółka z ograniczonąodpowiedzialnościąspółka komandytowa
WA R R A N T Y
DTM System provides operational and ready to use devices.
The producer gives 24 months warranty from the selling
date to the end customer. This time is counted according to
the producer warranty labels or serial numbers placed on
every product. Producer obliges himself to repair the device
for free if during the warranty period there are problems
which come because of his fault. Broken device should be
supplied on customer's expense to the place of purchase and
enclose clear and brief description of the breakage.The cost
of mount/dismount is covered by the user. The warranty
does not cover: batteries in the remote controls, faults
causedby improper usage, user self repairs and adaptations,
lightning strikes, voltages or short circuits in the electrical
grid.Appropriatelegalactsregulatedetailsofthe warranty.
D I S P O S A L
The intention of the WEEE Directive (Directive
2002/96/EC on waste electrical and electronic
equipment) is to reduce the amount of
hazardous substances in waste. The underlying
purpose is to promote the avoidance, recovery
and risk-free disposal of waste.
spółka z ograniczonąodpowiedzialnościąspółka komandytowa
DTM S ystem hereby
declares that the radio
receiver complies with
Directive 2014/53 / EU.
The full text of the EU
Declaration of Conformity is available at the
Internetaddress: www.dtm.pl

Popular Controllers manuals by other brands

JEON DG Series manual

JEON

JEON DG Series manual

ActronAir MGW-BACCS Operation manual

ActronAir

ActronAir MGW-BACCS Operation manual

Evco Vcolor 318 M Installer manual

Evco

Evco Vcolor 318 M Installer manual

Paragon EC7000 Series General instructions

Paragon

Paragon EC7000 Series General instructions

HKC ET Series Installation, operation & maintenance manual

HKC

HKC ET Series Installation, operation & maintenance manual

Seada G4K Pro Quick start manual

Seada

Seada G4K Pro Quick start manual

Alcatel OneTouch RC20 user guide

Alcatel

Alcatel OneTouch RC20 user guide

WIKA CPC8000 operating instructions

WIKA

WIKA CPC8000 operating instructions

GEM 9428000ZG05YS08C1A01015 operating instructions

GEM

GEM 9428000ZG05YS08C1A01015 operating instructions

Johnson Controls G861 Series Technical bulletin

Johnson Controls

Johnson Controls G861 Series Technical bulletin

Parker Aries AR-04CE Quick reference guide

Parker

Parker Aries AR-04CE Quick reference guide

Balcrank 3330-142 Operation, installation, maintenance and repair guide

Balcrank

Balcrank 3330-142 Operation, installation, maintenance and repair guide

Full Gauge Controls MT-514e manual

Full Gauge Controls

Full Gauge Controls MT-514e manual

Linak TD4 user manual

Linak

Linak TD4 user manual

STA-RITE SR6000S Installation & operation guide

STA-RITE

STA-RITE SR6000S Installation & operation guide

Muxall Pro BBQ Controller V3 manual

Muxall

Muxall Pro BBQ Controller V3 manual

Meridian 861 Instructions For Fitting

Meridian

Meridian 861 Instructions For Fitting

Stevens SOLO Quick start instructions

Stevens

Stevens SOLO Quick start instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.