Duratech Link Touch User manual

DLT10-RGB/TW
Manual

2
Table of contents
Technical specifications
Box contents
About the Link Touch
Installation instructions
Control functions: pool lights
Control functions: heat pump & pool cover
Advanced control functions: pool lights
Display: Status icons
Safety information
First use
How to use the Settings Menu
Connecting to ...
Cover operation settings
Beep settings
Temperature units display setting
Aux setting
Factory reset
Caring for the Link Touch
Troubleshooting
Resetting the Link Touch
Environment / disposal of old equipment
Service & warranty
Regulatory compliance
Page 3
Page 4
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10-11
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 19
Page 20
Page 22
Page 22
Page 22

3
Technical specifications
General specifications
Input Voltage: 5 V DC 0.5A
Interface: LoRa 868 MHz
USB-C
Ambient Air Temperature: 0°C to +40°C
Humidity 10% to 90% RH - non condensing
Ingress protection rate: IP20
IEC Protection Class: Class II
Size (in mm): 89,5 (Height)
186,5 (Width)
17,5 (Depth)
Weight: 298 g

4
Box contents
About the Link Touch
The Link Touch is the remote of your pool control system. By using the Link
Touch, you can control the lights, the heat pump and cover of your swim-
ming pool. The Link Touch includes an integrated Li-Ion battery which can
be charged automatically when mounted onto the wall mount.
The Link Touch connects wirelessly with a compatible Link Driver PLP-REM
and with DURA-V, DURA-Vi and DURAPRO heat pumps. Please check our
website for latest information regarding compatibility with heat pumps
The Link Touch can operate in dierent modes:
-
-
-
-
When the Link Touch is inserted in the wall mount, it will charge till full
battery.
When Link Touch is removed from the Wall mount, it will work instantly
when touched.
When the Link Touch is removed from the Wall Mount and it is not
touched for 15 seconds, it will turn into “Standby mode”. In this case the
display will be o. As soon as the touch panel is touched by the user, the
display will turn on again.
When the battery is empty, the Link Touch will no longer function. To turn
on the Link Touch again, it needs to be inserted into the powered wall
mount. In this case the display will be active again and the Link Touch will
start communicating with the external devices.

5
Installation instructions
1.5m
The Link Touch is powered using the included AC power adapter and USB
power cord
1. Plug the USB power cord into the power adapter
2. Plug the other end of the USB power cord into the USB connector
of the wall mount.
3. Plug the power adapter in a power outlet.
4. Mount the Link Touch onto the wall mount.

6
ON/OFF Lights:
Press to switch all Lights ON/OFF
Colour wheel:
Slide to change colour of Pool Lights
(only DLT10-RGB)
Colour program:
Press for previous colour program.
Colour program:
Press for next colour program.
Colour temp.:
Slide to the right to adjust the pool light
from “warmwhite” to “cool white”
Dimming level:
Slide to the right to increase
the brightness of the Pool Lights
Control functions: pool lights

7
Pool water Temp. UP:
Press to increase desired temperature
Pool cover OPEN:
Press and hold to open the pool cover.
When finger is removed from button
the cover will stop immediately
Pool cover CLOSE:
Press and hold to close the pool cover.
When finger is removed from the button,
the cover will stop immediately
ON/OFF heat pump:
Press to switch pool heat pump
ON/OFF
Pool water Temp. DOWN:
Press to decrease desired
temperature
NOTE:
Depending on AUX MODE, in settings
COVER OPEN/CLOSE or FUNC A/B
Control functions: heat pump & pool cover

8
ON/OFF Lights:
Press and hold for 1 second ON/OFF to see the
current settings
Activate the settings menu (*),
then use left arrow key to select the
desired setting.
Activate the settings menu (*),
then use right arrow key to select the
desired setting
(*) Touch the display for 3 seconds to
go in to the settings menu.
Advanced control functions: pool lights

9
Battery:
Signal:
Heat pump:
Pool lights:
Relays A and B:
Pool cover:
Battery capacity
Link Touch is communicating werelessly
Pool heat pump is on
Pool lights are connected
Relays A and B are connected
Pool cover is opening/closing
Pool Heat pump is on and heating
Pool lights are on
There is an error with relays A and B
There is an error with the pool cover
Pool heat pump has an error
There is an error with the pool lights
Battery is charging
No battery detected
Display: Status icons

10
Safety information
Intended use
This device has been developed as a remote control for swimming pool
accessories. The Link Touch should be used only for this purpose, as
described in this user guide.
Precautions for Setup
-
-
-
-
-
-
-
-
-
Precautions for Operation
-
-
-
-
-
The Link Touch can only be mounted indoor. Do not mount outdoors.
The power adapter is designed for 100 - 240V, 50/60 Hz. Verify if the
power outlet voltage is within this range before plugging in your power
adapter
Install the device close to an accessible power outlet. Make sure the
power/USB cable can be easily disconnected from the power outlet at
all times
Protect the power/USB cable and the power adapter from being strained
pinched or bucked
Place the Power/USB cable out of walkways to prevent tripping over the
cable.
Use only the power adapter provided with the Link Touch. Use of an
incorrect power adapter may cause overheating or fire.
Do not bend or place a heavy object on the power/USB cable as it could
damage the cable and result in risk of electric shock or fire
Do not use the power/USB cable if damage or frayed
Be sure to hold only the connector end of the power/USB cable when
disconnecting. Repeated pulling on the cable will damage the cable.
Protect the Link Touch from moisture and do not operate if power/USB
cable or plug are defective.
Never touch a power plug with wet hands.
Do not place anything on top of the Link Touch
Never spill liquid of any kind on the Link Touch
Do not drop or hit the Link Touch

11
Safety information
First use
Do NOT drop
the Link Touch
Fully charge the Link Touch
before using the device
The Link Touch is
NOT water proof
The Link Touch is
NOT dust proof
Precautions for Cleaning, Transport and Storage
-
-
Use a soft, damp cloth to clean the exterior of the Link Touch
Do not use cleaning tissues or chemical substances which might
damage the surface.
This Link Touch contains no user serviceable parts. Do not attempt to
service the Link touch yourself. Repair service should be performed by a
authorised technician.

12
How to use the Settings Menu
3
SEC
Tap
Tap
Tap
Touch the display on the Link Touch
for 3 seconds to go into the settings
menu.
Use arrow keys to select the desired
setting.
Touch the display once to confirm
the setting.

13
Select “Pair Start”-mode from the
settings menu.
Touch the screen once to put the Link
Touch in pairing mode.
Connecting to ...
This “Pairing”-mode will allow the Link Touch to establish a wireless con-
nection with other devices such as :
- PLP-REM, PLP-REM-300, PLP-REM-450, linking per functionality
(lights, cover)
- The heat pump
Note : In case the PLP-REM-450 is already linked with cover and lights and
heat pump , it will distribute the links to the Link Touch automatically.
Option 1:
Make sure the Link Touch is in close proximity (<2m) with the device which
you would like to pair with wirelessly. Select “Pair Start” on the Link
Touch. Power on the device.
The device will be in pairing mode for about 2 minutes after switched on.
The Link Touch will now be pairing with the device.
Option 2: (only in combination with PLP-REM-450)
Connect the Link Touch with the PLP-REM-450 using the USB cable. Select
“Pair start” on the Link Touch. The Link Touch will now be pairing with the
PLP-REM-450 and all linked devices (lights, cover and heat pump ) to it.

14
Cover operation settings
Go to “AUX SETTING” in the settings
menu.
Touch the screen and select “COVER”
Go to “DEADMANSWITCH” in the
settings. Touch the screen to select
“DEADMANSWITCH ENABLED”
There are 2 modes:
Deadman switch operation enabled:
The cover operation will run when pressing and holding the finger
on the button and will stop when releasing the finger from the button
Deadman switch operation disabled:
The cover operation will run with a single touch of the button
and will stop when touching the button again.
Warning :
Always make sure that when operating the cover with the remote device,
that the pool is always in sight of the operator, to make sure the path for the
cover is clear and nobody gets injured.
Note that Propulsions Systems cannot be held responsible for any
damage or injury during the operation of the cover.

15
Buzzer settings
Go to “BUZZER” in the settings menu.
Touch the screen to select the re-
quired operation mode. (note that
default setting is set to “BUZZER
ENABLED”.
The buzzer sound can be set to ON or OFF. If set to ON, then the buzzer
will sound each time as confirmation for touching any of the active areas
of the Link Touch. The beep will also sound when the Propulsion System’s
cover is in operation. In case of a third party cover, the beeping sound will
not be active
Warning :
It is advised to set the buzzer setting to “ON”, in order to have an audio
feedback during the operation of the cover.

16
Temperature units display setting
Go to “TEMPERATURE °C/°F” in the
settings menu.
Touch the screen to select the re-
quired units. (note that default setting
is set to “°C”.
The temperature units on the display can be set to Celsius or Fahrenheit

17
Aux setting
NOTE:
Repeat for “AUX MODE B”
Go to “AUX SETTING” in the settings
menu.
Touch the screen to select “AUX SET-
TING AUXILIARY”.
Go to “AUX MODE A” in the settings
menu.
Touch the screen to select the re-
quired mode “TOGGLE or “PULSE”.
This setting will allow the installer to change the cover function to an
ON/OFF function for a dierent device.
The “AuxSetting” can be set to enable or disable.
If disabled, then the Link Touch is considered to control a cover system.
If “AuxSetting” is enabled, then the Link Touch will control a dierent
device with the cover buttons and the buttons will act as an “ON” and
“OFF” button.

18
Factory reset
Go to “FACTORY RESET” in the set-
tings menu.
Touch the screen to reset the Link
Touch to factory settings
You can reset the Link Touch to the factory default settings.
Resetting the Link Touch reverts all settings to the factory default set-
tings. Any settings, including wireless connections, that have
been changed are lost.
The factory reset can be found in the setting menu.

19
Caring for the Link Touch
Troubleshooting
The Link Touch requires very little maintenance
-
-
This section includes information about what to do if you encounter
a problem with your Link Touch. If you need further assistance,
please contact your installer or distributor or go to the support
section of the Propulsion Systems website at
www.duratech.be/duracare
You may occasionally need to clean the exterior of the housing.
To clean the exterior of the Link Touch, wipe the exterior with
a soft, damp cloth.
NOTE: Do not use cleaning tissues or chemical substances
which might damage the surface
Don’t place the Link Touch in direct sunlight
Battery too hot
Heat pump error
Pool light error
Aux error
Cover error
remove from heat source or take out of sunlight
consult manual of heat pump for trouble shooting
consult manual of Pool light for trouble shooting
consult manual of auxiliary connected device for
trouble shooting
consult manual of cover for trouble shooting

20
Resetting the Link Touch
You can reset (=reboot) the Link Touch without loosing the preered set-
tings.
To reset the Link touch:
Press the “Reset” button on the back of the Link Touch, using a paperclip.
RESET
Table of contents
Other Duratech Remote Control manuals