Duratool D03405 User manual

Handheld Anemometer
Model: D03405
hold
set

1. Introduction
Congratulations on purchasing this pocket-sized anemometer. This innovative product provides
wind speed, wind chill, temperature, barometric and altitude information for any outdoor activity. The
operation of this product is simple and straightforward and by reading this operating manual, users
will receive the optimum benefits of all its features.
2. Inventory of contents
1) 1x Anemometer
2) 1x Tripod
3) 1 x 3V (CR2032) lithium cell
4) 1x Instruction manual
3. Features
1) Wind speed measure in mph, Km/h, m/s, ft/min or Knots
2) Wind speed in Beaufort wind scale bar graph
3) Wind chill display
4) Temperature display in degrees Fahrenheit or Celsius
5) Barometric display in hPa, inHg, mmHg
6) ABS/REL/MAX altitude display.
7) LED backlight
8) Low battery detection and display
9) Neck lanyard included
10) Tripod mounted
4. Setting up
Figure 1 Figure 2
1. First use a large coin to open the battery cover at the back of the anemometer as indicated above.
2. Checking the correct polarization, insert 1 x 3V (CR2032) lithium cell, positive (+) pole up into the
battery compartment and replace the cover as figure 1.
3. When the battery is inserted, all the segments of the LCD and backlight will light up briefly.
The anemometer can be tripod mounted as figure 2

5. Display Sections:
The display is divided into 2 sections as below figure shows:
6. Function keys:
The anemometer uses the following keys:
6.1 SET key:
In normal mode, press this key to toggle between Wind speed/Altitude modes.
In setting mode, press this key can change set item, if now set the last item, then press this
key to out of setting mode.
Press the key for 2s to enter the setting mode (default set item is wind speed unit)
Press the key for 4s to power off the unit. Press the key for 2s again to power on the unit.
6.2 LIGHT key :
In the wind speed mode, press to toggle between temperature/wind chill
In the Altitude mode, press to toggle between barometric and temperature.
Press the key for 2s to turn on the backlight for 8s.
6.3 + key:
In wind speed mode, press it to change the display current WIND (default) →maximum
WIND →Average WIND.
In wind speed mode, hold this key for 2 seconds, current/Max/Average wind speeds will be
cleared.
In the Altitude mode, press it to change the display Current Relative Altitude (default)
→Maximum Current Altitude →Absolute Altitude.
When display the Current Relative altitude, hold the key for 2 seconds, the current altitude
can be set as “0”.
When display the Maximum Relative Altitude,hold the key for 2 seconds, the Maximum
Relative Altitude will be cleared.
7. Wind Speed& Temperature vs. Altitude& Baromtric display
Pressing the “SET” key to toggle between wind speed and altitude display
7.1 Wind Speed& Temperature Display Mode
7.1.1 Wind Speed Display
There are three wind speed display modes:
Current wind speed (WIND)
Maximum wind speed (ΔWIND)
Average wind speed ((ΦWIND)
Sub display: 1.display temperature/wind chill under
wind speed mode. 2. Display barometric and
temperature under Altitude mode.
Main display: Wind speed/Altitude display modes

Press the + key to toggle between the three wind speed display modes.
Current wind speed maximum wind speed average wind speed
Current wind speed: device will measure the current speed and update every 1.5 seconds.
Maximum wind speed: During the measuring, the Maximum value of wind speed logged. It will be cleared
after a restart.
Average wind speed: The average value of recent 10 times measurements of wind speed..
Wind speed measuring range
The wind speed measuring range is 1mph(0.3m/s) ~ 67mph(30m/s), if the speed between 0.0m/s
and 0.3m/s,the wind speed will show 0m/s,and if the speed over 30m/s,the wind speed will show
“--.-“.
Note:
1. It will stop measuring wind speed once exit wind speed mode.
2. If no wind speed or no button operation within 30 minutes under wind speed mode, it power off
automatically.
3. Current, maximum and average wind speed will be cleared after power off.
7.1.2 Temperature Display
There are two temperature display modes:
Temperature
Wind Chill
Press the Light key to toggle between the two temperature display modes.
Temperature Wind Chill
Current temperature:
The anemometer measures temperature in real time and updated every 1 minute. The Temperature
measuring(and wind chill) range is -30℃-60℃. If the temperature out of range, it display “- -.-”. and
the wind chill also display “--.-”.

Wind Chill
The anemometer calculates automatically wind chill, which can provide useful information for
preparing outdoor activities in cold weather. “Wind chill” provides an indication of how cold it feels
given the combined effects of the actual air temperature and the wind speed. Wind chill temperature
is only defined for temperatures at or below 50 °F(10 °C) and wind speeds above 4.8 kilometers per
hour. Wind chill temperature will be the same as current temperature above 50 °F(10 °C).
7.2 Altitude& Baromtric display
7.2.1 Altitude Display
There are three altitude display modes:
Relative Altitude
Maximum Altitude
Absolute Altitude
Press the + key to toggle among the three altitude display modes.
Relative Altitude Maximum Relative Altitude Absolute Altitude
Absolute Altitude
With the increasing of altitude, the barometric will be decreasing accordingly. The anemometer will
calculate the altitude of current position relative to the horizon, based on the changing of barometric
value.
Relative Altitude
The altitude at the spot when the anemometer is powered on will be set as “0”.
Note: The altitude (both ABS and REL Altitudes) will show” --.-”if the barometric is out of the range
600-1100hPa.
7.2.2 Barometric Display
Press the Light key to toggle between barometric and temperature display modes.
Barometric Temperature

Barometric
When user select the barometric display, the anemometer will measure and update the barometric
every 3 seconds in the first 3 minutes. After 3 minutes, the updating interval becomes 1 minute. And
the ABS/REL altitude will be calculated based on barometric values.
Note: The barometric will show” --.-” if the barometric is out of the range 600-1100hPa.
Note:If no button operation within 24 hours under altitude mode, it power off automatically.
8. SET Mode
Press and hold the “SET” key for 2 seconds to enter the setting mode.
(1) The wind speed unit will display and flash. Press “+” key to cycle among m/s, Km/h, mph, Knots
and ft/min. Press “SET” key to confirm and advance to the next step.
(2) The temperature unit will begin flashing. Press “+” key to cycle between °C and °F. Press “SET”
key to confirm and advance to the next step.
(3) The barometric unit will begin flashing. Press “+” key to cycle among hPa, inHg, mmHg. Press
“SET” key to confirm and advance to the next step.
(4) The altitude unit will begin flashing. Press “+” key to cycle between m, feet. Press “SET” key to
confirm and advance to the next step.
Set Wind speed unit Set temperature unit Set barometric unit
Set altitude unit
Long press the “SET” key to exit the Setting mode and enter to measuring mode. Press and hold the
“SET” key for 4 seconds can enter the Power Off status,
Note:If no key operation in 15s, the unit will return to the normal mode automatically.
9. Other features
9.1 Beaufort wind scale (bft)
The Beaufort scale is displayed in bar graph (0-12). This is a system for estimating wind force
without the use of instruments based on the visible effects of the wind on the physical environment.

Beaufort scale
m/s kts mph km/h ft/min
0 0-0.2 0-1 0-1 0-1 0-58
1 0.3-1.5 1-3 1-3 1-5 59-314
2 1.6-3.3 4-6 4-7 6-11 315-668
3 3.4-5.4 7-10 8-12 12-19 669-1082
4 5.5-7.9 11-16 13-18 20-28 1083-1574
5 8.0-10.7 17-21 19-24 29-38 1575-2125
6 10.8-13.8 22-27 25-31 39-49 2126-2735
7 13.9-17.1 28-33 32-38 50-61 2736-3385
8 17.2-20.7 34-40 39-46 62-74 3386-4093
9 20.8-24.4 41-47 47-54 75-88 4094-4822
10 24.5-28.4 48-55 55-63 89-102 4823-5609
11 28.5-32.6 56-63 64-72 103-117 5610-6417
12 >63 >72 >117 >6417
9.2 Low battery display
The unit will detect the voltage of battery just after power on. In normal
mode, the unit detects low battery every 10 minute. In power off
mode do not detect it, if the battery voltage is low, the icon will
be displayed.
9.3 Power ON/OFF
Press and hold down the “SET” key for 4 seconds to switch the unit
ON or OFF. In power off mode the unit will sleep and do not detect
the wind speed and temperature data, all the history data will be
cleared too.
In Wind speed mode, the meter will automatically switch OFF when no key is pressed and the wind
speed is zero for 30 minutes to save battery life.
In Altitude display mode, the meter will automatically switch OFF when no key is pressed for 24hours
to save battery life.
10. Glossary of Terms
Term Definition
Accuracy Accuracy is defined as the ability of a measurement to match the
actual value of the quantity being measured.
Beaufort Scale The Beaufort Scale is an empirical measure for describing wind
speed based mainly on observed sea conditions (on land it is
categorized by the physical effects it has on vegetation and
structures). Its full name is the Beaufort Wind Force Scale.
>32.6

Comfort Level
Comfort level is the body’s effect based on ranges of temperature.
Range
Range is defined as the amount or extent a value can be measured.
Wind Chill
Wind chill is the felt air temperature on exposed skin due to wind. It
measures the effect of wind on air temperature. The wind chill
temperature is usually lower than the air temperature, since the air
temperature is usually lower than the human body temperature.
-29.9°C to +59°C with 0.1°C resolution
(-21.8 °F to 138.2 °F with 0.2° resolution)
(“---“displayed if outside this range)
every 1 minute
1.5m/s - 30 m/s (3.3 mph - 67mph)
600-1100hPa
-500m-3000m
1 x 3V lithium cell (CR2032)
Approximately 12 months
50 x 18 x 140 mm (2” x 0.7” x 5.5”)
11.Specifications
Recommended operating temperatures :
Temperature checking interval :
Wind speed measuring range Barometric :
Measuring range :
Altitude measuring range :
Power source :
Battery life :
Dimensions (L x W x H) :
12. Troubleshooting Guide
Problem
Solution
Wind Chill shows --.-
The wind chill is meaningless above 50 °F, and is not
displayed (out of range, or - -.-).
Impeller appears imbalanced.
It is normal for the impeller to oscillate as it comes to a
stop, and it is not imbalanced. The unit contains a very
small magnet that responds to the earth’s magnetic
fields. This does not affect the accuracy of the wind
speed readings and only apparent when slowing or
accelerating.
Vane is noisy at high speed.
This is normal for the vane to vibrate at high speed.
Do not operate above 67 mph.
Above 67 mph, the unit will display ---.
Display is dim or disappears.
The LCD display will not operate below approximately
14 °F. Use the warmth of your body or environment for
use in cold weather conditions, or Battery is dead.
Replace the battery.
1. T
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronic
Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste,
but kept separate for the treatment, recovery and recycling of the materials used. Contact your local
authority for details of recycling schemes in your area.
Made in China.
PO Box 13362 Dublin 2
PR2 9PP
Table of contents
Other Duratool Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

ACS contsys
ACS contsys DAL-311x3x0S operating instructions

Auber Instruments
Auber Instruments SYL-1813 instruction manual

Cateye
Cateye VELO WIRELESS Plus CC-VT210W quick start

CARLO GAVAZZI
CARLO GAVAZZI EM24 M1 user manual

OSCILLA
OSCILLA SM960-C Calibration manual

Powerfix Profi
Powerfix Profi 280231 Operation and safety notes