Maximum (FULL) Airflow L v l: When only the top orange light is illuminated it indicates that
the VS
®
is operating at the maximum airflow level. epending on the house size there may be
a significant jump in the airflow from 7½ orange lights to when only the top orange light is
illuminated. Use for short periods of time only. See below for more information.
Summ r Mod : The orange lights will continue to be illuminated when the VS
®
is operating in
SUMMER mode and is temporarily switched off due to the roof space air temperature exceeding
19ºC (see Summer Setting below).
Wint r Mod : There will be no change to the number of orange lights illuminated when the
airflow automatically increases to the ‘heat recovery’ setting due to the roof space air
temperature exceeding 19ºC when your VS
®
is operating in WINTER mode (see Winter Setting
below).
PRE-SET CALIBRATED AIRFLOW LEVEL
Your DVS
®
is calibrat d and pr -s t, bas d on th siz and charact ristics of your hom , to op rat
at our r comm nd d airflow l v l to b st control your cond nsation.
The pre-set airflow level is indicated by 4 orange lights on the AIRFLOW panel.
How to Incr as or D cr as th Airflow from your DVS
®
You can easily adjust the airflow from your VS
®
by pressing the MORE or LESS arrows on the AIRFLOW
touch pad:
Press the MORE arrow to increase the airflow.
Press the LESS arrow to decrease the airflow.
Each press of the MORE or LESS arrow is equivalent to a ‘half’ increase or decrease in the orange lights
illuminated on the Indicator Bar. Therefore, two pushes of an arrow are required to fully turn on or
turn off one full orange light.
NOTE that while the airflow level is indicated b the number of lit orange lights, because of the wa each
DVS
®
is calibrated, six illuminated lights are not necessaril twice the airflow indicated b three lights.
For further examples and suggestions as to when and why you might wish to alter the airflow settings,
please refer to the General Operating Guidelines and Principles for All VS
®
Models.
How to Manually Turn Your DVS
®
OFF
Repeatedly press the LESS arrow until a red light appears at the bottom of the Indicator Bar.
Your VS
®
will remain switched OFF.
To turn your VS
®
ON again press the MORE arrow once. Your VS
®
will return to its pre-set
AIRFLOW level (4 lights). You may now adjust the AIRFLOW up or down by pressing the MORE or
LESS arrows.
How to Op rat Your DVS
®
on FULL (Maximum) AIRFLOW
Press the MORE arrow repeatedly until a single orange light appears at the top of the Indicator
Bar.
To return your VS
®
to its pre-set AIRFLOW level (4 lights), press the LESS arrow once. You may
now adjust the AIRFLOW up or down by pressing the MORE or LESS arrows.
Operating at FULL airflow is not necessary for condensation control and should only be used
occasionally for maximum heat recovery on a warm or sunny day, or to more rapidly clear smoke
or smells from the house.