manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dwyer Instruments
  6. •
  7. Data Logger
  8. •
  9. Dwyer Instruments DW-USB Series Operating instructions

Dwyer Instruments DW-USB Series Operating instructions

eries DW-U B Compact U B Data Logger
pecifications and Operating Instructions
Bulletin E-90-CDW
The eries DW-U B Compact U B Data Logger allow users to
monitor temperature, humidity, dew point, voltage, current, or carbon
monoxide. The user can select the sampling rate, start time, high/low
alarm settings, and temperature unit parameters with the free
downloadable Windows®-based application. Stored data is downloaded
by plugging the module into a PC’s USB port. Alarm status and low
battery is indicated via built-in flashing ED’s. When the protective cap
is fitted, the data logger resists moisture to IP67 standards.
PECIFICATION
Range:
DW-USB-1: -31 to 176°F (-35 to 80°C);
DW-USB-2: -31 to 176°F (-35 to 80°C), 0 to 100% RH;
DW-USB-2-HA: -31 to 176°F (-35 to 80°C), 0 to 100% RH;
DW-USB-3: 0 to 30 VDC;
DW-USB-4: 4 to 20 mA;
DW-USB-5: 0 to 1000 ppm;
DW-USB-5- R: 0 to 300 ppm;
DW-USB-6: J-type: -202 to 1652°F (-130 to 900°C); K-type: -328 to
2372°F (-200 to 1300°C); T-type: -328 to 662°F (-200 to 350°C).
Accuracy:
DW-USB-1: ±2°F (±1°C);
DW-USB-2: ±1°F (±0.5°C), 3% RH;
DW-USB-2-HA: ±0.6°F (±0.3°C), 2% RH;
DW-USB-3: ±1%;
DW-USB-4: ±1%;
DW-USB-5: ±6%;
DW-USB-5- R: ±4%;
DW-USB-6: ±1.5°F (±1°C).
Resolution:
DW-USB-1: 1°F (0.5°C);
DW-USB-2: 1°F (0.5°C), 0.5% RH;
DW-USB-2-HA: 1°F (0.5°C), 0.5% RH;
DW-USB-3: 50 mVDC;
DW-USB-4: 0.05 mA;
DW-USB-5: 0.5 ppm;
DW-USB-5- R: 0.5 ppm;
DW-USB-6: 0.9°F (0.5°C).
Memory ize: 16,382 temperature; 16,382 each temperature and RH;
32,764 readings for voltage, current, and thermocouple; and 32,510 for
carbon monoxide.
ampling Mode: Stop on memory full.
ampling Rate: Selectable from 10 sec to 12 hrs (DW-USB-1, DW-
USB-2, DW-USB-2-HA), 1 sec to 12 hrs (DW-USB-3, DW-USB-4, DW-
USB-5, DW-USB-5- R:) and 10 sec to 5 min (DW-USB-6).
Computer Requirements: Windows®98, Windows® 2000, Windows®
XP, Windows NT®, Windows®7 or Windows Vista® 32-bit or 64-bit
operating systems.
Power Requirements: 3.6V lithium battery.
Housing: ABS plastic blend.
Alarms: Programmable high/low.
Interface: USB port.
Weight: 1.5 oz (43 g).
Agency Approvals: CE, RoHS.
(Single flash)
(Parpadeo simple)
(Double flash)
(Parpadeo doble)
(Single flash)
(Parpadeo simple)
(Double flash)
(Parpadeo doble)
(Single/Double flash every 10 sec)
(Parpadeo doble/simple cada 10 seg)
(Single flash every 60 sec)
(Parpadeo simple cada 60 seg)
ogging, no alarm on channel.
Registrando, sin alarma.
Delayed start.
El Registrado está preparado.
ogging, low alarm on channel.
Alarma baja.
ogging, high alarm on channel.
Alarma alta.
Memory full.
Memoria llena.
ow battery.
Batería baja.
DW-U B-1: Features an orange problem condition ED and green/red ED for
alarm status.
LED FLA HING MODE
Y
X
MODEL DW-USB-X
LED
CO SENSOR CAP
TERMINAL BLOCK CAP VENTED
CLIP STANDARD
CLIP
4-51/64
[121.73]
Ø1-3/32
[27.76]
MODEL DW-USB-CASE
1-3/64
[26.59]
1-1/16
[26.99]
(Single flash)
(Parpadeo simple)
(Double flash)
(Parpadeo doble)
(Triple flash)
(Parpadeo triple)
(Single flash)
(Parpadeo simple)
(Double flash)
(Parpadeo doble)
(Triple flash)
(Parpadeo triple)
ogging, no alarm on channel.
Registrando, sin alarma.
Delayed start.
El Registrado está preparado.
Memory full, no alarm on last stored value.
Registrador lleno, sin alarma en el canal.
ogging, low alarm on channel.
Registrando, alarma baja en el canal.
ogging, high alarm on channel.
Registrando, alarma alta en el canal.
ogger full, alarm on channel.
Registrador lleno, alarma en el canal.
DW-U B-2, DW-U B-2-HA: Features 2 clearly marked bi-colored EDs, one
for temperature and one for RH.
Windows®, Windows NT®, and Windows Vista®
are registered trademarks of Microsoft Corporation.
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.877.766.5412
(Single flash)
(Parpadeo simple)
(Double flash)
(Parpadeo doble)
(Single flash)
(Parpadeo simple)
Double flash)
(Parpadeo doble)
(Single flash)
(Parpadeo simple)
ogging, no alarm on channel.
Registrando, sin alarma.
ogging, no alarm on channel,
low battery.
Registrando, sin alarma, batería
baja.
Delayed start.
Inicio demorado.
Memory full, no alarm on last
stored value.
Registrador lleno, sin alarma en
el canal.
ogging, low alarm on channel.
Registrando, alarma baja en el
canal.
ogging, low alarm on channel,
low battery.
Registrando, alarma baja,
batería baja.
ogging, high alarm on channel,
low battery.
Registrando, alarma alta en el
canal.
ogging, high alarm on channel,
low battery.
Registrando, alarma alta en el
canal, batería baja.
DW-U B-3, DW-U B-4, DW-U B-5, DW-U B-5-LR, and DW-U B-6: Features
a red and green ED.
every 10 seconds
cada 10 segundos
every 20 seconds
cada 20 segundos
every 30 seconds
cada 30 segundos
every 20 seconds
cada 20 segundos
every 10 seconds
cada 10 segundos
every 20 seconds
cada 20 segundos
every 10 seconds
cada 10 segundos
every 20 seconds
cada 20 segundos
Memory full, alarm on last stored value.
Memoria llena, alarma en el canal.
BATTERY IN TALLATION
Before using the data logger, you will need to insert the 3.6 V 1/2 AA
battery provided, following the instructions below.
OFTWARE IN TALLATION
This software must be installed prior to the USB Driver. Please follow the
instructions below then refer to the USB Driver Installation based on the
Windows®operating system you are using.
1. Visit our website www.dwyer-inst.com/DW-USBSoftware and click
on the download link. If the download folder doesn’t open directly,
go to your computer’s “Downloads” folder and double-click on the
“Easy ogUSBV610_Dwyer” folder.
2. Double-click on “setup” then follow the on screen instructions to
complete the Configuration Software Installation.
3. An Easy og USB icon will now be placed on your desktop.
U B DRIVER IN TALLATION
Windows®XP/Windows Vista®/Windows®7 Operating ystems:
You must install the Configuration Software as instructed in the previous
section before going through these steps.
1. Insert the USB data logger directly into a USB port on the computer.
Installation screens should automatically appear.
2. Follow the on screen instructions to complete the Configuration
Software Installation. If a compatibility error window appears, click
˝Continue Anyway˝. Note: This will not cause any adverse
changes/effects on your computer.
3. You can now begin using our data logger by double clicking on the
Easy og USB icon on your computers desktop.
Windows®98/Windows®2000 Operating ystems:
You must install the Configuration Software as instructed in the
previous section before going through these steps.
1. Insert the USB data logger directly into a USB port on the computer.
Installation screens should automatically appear.
2. Follow the on screen instructions to complete the USB Driver
Installation.
3. You can now begin using our data logger by double clicking on the
Easy og USB icon on your computers desktop.
Carbon Monoxide afety Notice
The DW-USB-6 is not a suitable substitute for a domestic or
industrial carbon monoxide detector/alarm.
MAINTENANCE
Upon final installation of the Compact DW-USB Data ogger, no routine
maintenance is required. eaving the logger plugged into your computer
for an extended period of time will considerably lower its battery life. The
Series DW-USB is not field serviceable and should be returned if repair
is needed (field repair should not be attempted and may void warranty).
Be sure to include a brief description of the problem plus any relevant
application notes. Contact customer service to receive a Return Goods
Authorization number before shipping.
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.877.766.5412

This manual suits for next models

8

Other Dwyer Instruments Data Logger manuals

Dwyer Instruments DW-USB-1 Operating instructions

Dwyer Instruments

Dwyer Instruments DW-USB-1 Operating instructions

Dwyer Instruments DW-USB-1 Operating instructions

Dwyer Instruments

Dwyer Instruments DW-USB-1 Operating instructions

Dwyer Instruments DW-DATAPAD Operating instructions

Dwyer Instruments

Dwyer Instruments DW-DATAPAD Operating instructions

Dwyer Instruments WTDL-30 User manual

Dwyer Instruments

Dwyer Instruments WTDL-30 User manual

Dwyer Instruments DW-USB Series User manual

Dwyer Instruments

Dwyer Instruments DW-USB Series User manual

Dwyer Instruments LS1 Installation and operating instructions

Dwyer Instruments

Dwyer Instruments LS1 Installation and operating instructions

Popular Data Logger manuals by other brands

Lutron Electronics MHB-382SD manual

Lutron Electronics

Lutron Electronics MHB-382SD manual

Philips D 6450 manual

Philips

Philips D 6450 manual

Extech Instruments CO220 user manual

Extech Instruments

Extech Instruments CO220 user manual

PICO ADC-11/10 installation guide

PICO

PICO ADC-11/10 installation guide

TiTLEY Scientific CHORUS user manual

TiTLEY Scientific

TiTLEY Scientific CHORUS user manual

ABB i-bus BDB/S 1.1 product manual

ABB

ABB i-bus BDB/S 1.1 product manual

MadgeTech Titan S8 Product user guide

MadgeTech

MadgeTech Titan S8 Product user guide

Giacomini GE552Y052 user guide

Giacomini

Giacomini GE552Y052 user guide

GRAPHTEC midi LOGGER HV user manual

GRAPHTEC

GRAPHTEC midi LOGGER HV user manual

dataTaker CANgate user manual

dataTaker

dataTaker CANgate user manual

Grosvenor GT10S installation guide

Grosvenor

Grosvenor GT10S installation guide

MadgeTech MadgeNet RFRHTemp2000A Product user guide

MadgeTech

MadgeTech MadgeNet RFRHTemp2000A Product user guide

3nStar Nustar 5sx user manual

3nStar

3nStar Nustar 5sx user manual

Onset HOBO U30 GSM user guide

Onset

Onset HOBO U30 GSM user guide

Geosense GEOLOGGER G8 PLUS Advanced instruction manual

Geosense

Geosense GEOLOGGER G8 PLUS Advanced instruction manual

LogTag TRIX-8 quick start guide

LogTag

LogTag TRIX-8 quick start guide

Neptune Technology E-Coder)R900i Installation and maintenance guide

Neptune Technology

Neptune Technology E-Coder)R900i Installation and maintenance guide

Escort MU-IN-D-8-L user guide

Escort

Escort MU-IN-D-8-L user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.