dymax Accu-Cal 50 User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Dymax Accu-Cal 50 at our website: Click HERE

Dymax ACCU-CAL™ 50 User Guide
UV Radiometer
Instructions for Safe Use
Setup and Operation
Maintenance
Ordering Spare Parts and Accessories
ACCU-CAL™ 50 for Flood Lamps (PN 39561) ACCU-CAL™ 50 for Spot Lamps (PN 39560)

2
Dymax ACCU-CAL™ 50 Radiometer User Guide
About Dymax
UV/Visible light-curable adhesives. Systems for light curing, fluid dispensing, and fluid packaging.
Dymax manufactures industrial adhesives, light-curable adhesives, epoxy resins, cyanoacrylates, and activator-cured adhesives.
We also manufacture a complete line of manual fluid dispensing systems, automatic fluid dispensing systems, and light-curing systems.
Light-curing systems include LED light sources, spot, flood, and conveyor systems designed for compatibility and high performance
with Dymax adhesives.
Dymax adhesives and light-curing systems optimize the speed of automated assembly, allow for 100% in-line inspection, and increase
throughput. System designs enable stand-alone configuration or integration into your existing assembly line.
Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the
intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in the Dymax
standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to insure that desired
performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation by offering equipment trial
rental and leasing programs to assist in such testing and evaluations. Data sheets are available for valve controllers or pressure pots upon
request.

3
Dymax ACCU-CAL™ 50 Radiometer User Guide
Contents
Introduction ................................................................................................................................4
Safety ..........................................................................................................................................4
General Safety................................................................................................................................................4
Safety .............................................................................................................................................................5
Sécurité ..........................................................................................................................................................5
Sicherheitshinweise .......................................................................................................................................5
Product Overview ........................................................................................................................6
Description of the ACCU-CAL™ 50 Radiometer .............................................................................................6
Installation ..................................................................................................................................6
Unpacking and Inspecting Your Shipment .....................................................................................................6
Parts Included in the Spot Configuration .......................................................................................................6
Parts Included in the Flood Configuration .....................................................................................................6
Operation ....................................................................................................................................7
Maintenance ...............................................................................................................................9
Spare Parts and Accessories .........................................................................................................9
Spare Parts .....................................................................................................................................................9
Specifications.............................................................................................................................10
Warranty ...................................................................................................................................10

4
Dymax ACCU-CAL™ 50 Radiometer User Guide
Introduction
The enclosed ACCU-CAL™ 50 UV Radiometer was developed and manufactured by the Dymax team, driven by
a desire to best serve your needs. Before shipping, your ACCU-CAL™ 50 Radiometer was calibrated and tested
against standard UV light sources to ensure accurate performance.
The operation of this radiometer in conjunction with a UV light-curing system will maximize safety and user-
friendly performance and provide optimum yield of your technological process.
Therefore, we encourage you to read, understand, and follow all safety and operating instructions and
recommendations compiled in this and other related manuals prior to setting up and operating this
instrument and any associated UV light-curing systems.
If you encounter a problem or have any questions, please contact our Technical or Customer Support
Departments at 860-482-1010. Trained Dymax professionals are standing by to serve you.
Par conséquent, nous vous encouragez a lire, comprend, et suivre tout sécurité et instructions d’opération et
conseillations rédiger dans cette et autre manuels etablir un lien avant de mettre en place et de faire marcher
cette nouveau système de lampe de tache ou cettes composants individuel.
Si vous rencontrez un problème, avait n’importe de questions, ou si vous voudrez de nous aider avec tes
suggestions ou conseillations, s’il vous plait contacte notre departements technique ou service client à 860-
482-1010. Dymax formé professionals attendre a vous servir.
Safety
General Safety
WARNING! This symbol alerts you to the possibility of serious injury or death if you do not
follow the instructions.
CAUTION! Always wear protective goggles or face shield when working near the front of any
unit which emits UV light! The rear of some units also emit stray UV light.
WARNING! Always observe safety requirements!
PRÉ-CAUTION! Toujours faisez de l’usage des lunettes de protection ou protéger de visage
marche près du devant d’élément!
PRÉ-CAUTION! Risque de décharge électrique quand le couvert est enlever!
ACHTUNG! Tragen Sie immer eine Sicherheitsbrille oder einen Gesichtsschutz, wenn Sie nahe
an der UV Lichtquelle arbeiten. Die Rückseite des Gerätes emittiert gestreutes UV Licht!
WARNHINWEIS! Bitte beachten Sie immer die Sicherheitshinweise!

5
Dymax ACCU-CAL™ 50 Radiometer User Guide
Safety
The ACCU-CAL™50 Radiometer is designed to be used in conjunction with Dymax UV light-curing equipment
that is properly set up, with components correctly connected, and operated in accordance with relevant
instructions.
Safety Recommendations:
When working with UV light sources, use the goggles provided, or a face shield approved for UV protection to
protect your eyes.
Long-sleeved shirts, or a lab coat, are recommended to protect the arms, and use of UV opaque gloves will
protect the hands.
Sécurité
L’équipment ètre concu pour ètre utilisé correctement constituer, avec composants brancher correctement,
et marché en conformément avec instructions important. Le plan étais developer pour render au maxime
opérateur sécurité et minimiser expositon à ultraviolette.
Recommander de sécurité:
Emploi lunettes, ou un protéger de visage pour protection de ultraviolet pour protéger vous oeux.
Chemises à manche long, ou manteau de labo, sont recommander pour protéger les bras, et utilisation de
ultraviolette gants opague vais protéger les mains.
Sicherheitshinweise
Dieses Gerät wurde so entwickelt, dass es nur vollständig, alle Komponenten korrekt miteinander verbunden,
in Übereinstimmung mit relevanten Instruktionen betrieben wird. Bei der Entwicklung wurde weiterhin
großen Wert auf die Benutzersicherheit und minimale UV Belastung gelegt.
Sicherheitshinweise:
Tragen Sie immer die mitgelieferten Sicherheitsbrille oder speziellen Gesichtsschutz, der Ihre Augen vor UV
Licht schützt.
Wir empfehlen Langarm - Hemden oder einen Laborkittel zu tragen, um die Arme zu schützen. Für die Hände
empfehlen wir UV- geblockte Handschuhe.
BITTE BEACHTEN SIE: Durch den installierten inneren Filter strahlt die BlueWave® 200 UVA und sichtbares
Licht aus. Schauen Sie deshalb niemals direkt in die Lichtquelle, wenn das Gerät angeschaltet ist.

6
Dymax ACCU-CAL™ 50 Radiometer User Guide
Product Overview
Description of the ACCU-CAL™ 50 Radiometer
The ACCU-CAL™ 50 Radiometer is a microprocessor-based measurement instrument designed to measure
UVA radiation in the range of 320-390 nm.
The ACCU-CAL™ 50 uses two AA batteries.
Environmental Considerations
Optical measurement instruments are sensitive to extremes in environmental conditions like high
temperature, humidity, and contamination. Protect the device and its detector(s) from high humidity,
high temperature, direct sunlight, and contamination.
Do not use the ACCU-CAL™ 50 immediately after moving it from a cold to a warm environment. Under
certain circumstances, condensation could develop and may cause inaccurate measurement results.
Allow the device to adjust to room temperature before use.
Do not use the ACCU-CAL™ 50 in powerful magnetic, electromagnetic, and electrostatic fields. These
disturbances may influence measurement results.
Installation
Unpacking and Inspecting Your Shipment
When your radiometer arrives, inspect the box for damage and notify the shipper of box damage immediately.
Open the box and check for equipment damage. If parts are damaged, notify the shipper and submit a claim
for the damaged parts. Contact Dymax so that new parts can be shipped to you immediately.
Check that the parts included in your order match those listed below. If parts are missing, contact your local
Dymax representative or Dymax Customer Support to resolve the problem.
Parts Included in the Spot
Configuration
ACCU-CAL 50 Radiometer
ACCU-CAL 50 Radiometer User Guide
3-mm, 5-mm, 8-mm Adapters
Lightguide Simulator (PN 38408)
Parts Included in the Flood
Configuration
ACCU-CAL 50 Radiometer
ACCU-CAL 50 Radiometer User Guide

7
Dymax ACCU-CAL™ 50 Radiometer User Guide
Figure 1. Spot Radiometer (PN39560)
Figure 2. Flood Radiometer (PN39561)
Operation
1. The ACCU-CAL™ 50 Radiometer may be used to measure UV intensity from Flood Lamps or UV
intensity from the end of a 3-mm, 5-mm, or 8-mm lightguide used with a Spot Lamp. For Flood Lamp
use, attach the Detector to the Radiometer as shown in Figure 3.
2. For Spot Lamp use, select an Adapter that matches the size of the Lightguide that is installed on the
Spot Lamp. 3-mm, 5-mm, and 8-mm Adapters are available.
NOTE: Lightguide Adapters are included in the spot version (PN 39560) of the ACCU-CAL™ 50 or
available separately.
Figure 3. Radiometer with Detector
Figure 4. Lightguide Adapters
3. Install the Lightguide Adapter on the end of the Detector using the two, 2 mm screws provided.

8
Dymax ACCU-CAL™ 50 Radiometer User Guide
Figure 5. Adapter Installation
4. Attach the Lightguide Adapter to the Spot Lamp Lightguide by inserting the Lightguide into the
Lightguide Adapter until it bottoms out. Tighten the set screw when the Lightguide is installed.
5. Press and release the On/Off Key on the Face Plate to turn the Radiometer on and off.
Figure 6. Attach Lightguide Adapter to Lightguide (Step 4)
Figure 7. Face Plate
6. Press and release the Light Source Key to select the light source being measured. The different light
source options are:
Flood Lamp - For use when measuring UV intensity of a flood-lamp light source.
3-mm Lightguide - For use when measuring UV intensity at the end of a 3-mm lightguide.
5-mm Lightguide - For use when measuring UV intensity at the end of a 5-mm lightguide.
8-mm Lightguide - For use when measuring UV intensity at the end of a 8-mm lightguide.
7. Press and release the Mode Key to select an operating mode. The different operating modes are:
Peak Intensity - Shows the highest UV intensity in mW/cm2seen by the detector during the
measurement.
Intensity - Shows the UV intensity in mW/cm2at the detector during the measurement.
Dose - Shows the total UV dose in mJ/cm2at the detector during the measurement.

9
Dymax ACCU-CAL™ 50 Radiometer User Guide
Maintenance
The ACCU-CAL™ 50 was designed to operate with minimum maintenance. Follow the schedule below to
assure top unit performance.
•Calibrate the instrument at least annually. Calibration service is available through Dymax Customer
Service or Dymax Product Repair.
•Change the batteries when a low battery warning is received. The ACCU-CAL™ 50 uses two AA-type
batteries. The battery compartment is on the back of the instrument.
Figure 8. Battery Compartment (Closed & Open)
•Keep the detector head’s sensing element clean and free of contaminants. The detector head may be
cleaned with a clean tissue wetted with isopropyl alcohol.
•To increase battery life, turn unit power off after use. The unit will not automatically power off.
Spare Parts and Accessories
Spare Parts
Item
Part Number
Adapter Kit –Flood to Spot Model (includes parts listed below)
39554
Lightguide Simulator
38408
8-mm Lightguide Adapter
39558
5-mm Lightguide Adapter
39557
3-mm Lightguide Adapter
39556

10
Dymax ACCU-CAL™ 50 Radiometer User Guide
Specifications
Property
Specification
Power
Two AA size batteries
Display
LCD Graphic Display 97x 32 Pixel
Display area: 0.56 in x 1.41 in (14.3 mm x 35.8 mm)
Detector Interface
9-Pin MDSM9 socket, 4 inputs
Measurement
Ranges
Four modes of operation
Auto range within each operating mode
Front Panel Control
3 buttons
Temperature
Operating: 5 to 40°C
Storage: -10 to 50° C
Size
5.71 in x 2.48 in x 1.18 in (145 mm x 63 mm x 30 mm)
Weight
0.33 lbs (150 g)

11
Dymax ACCU-CAL™ 50 Radiometer User Guide
Warranty
From date of purchase, Dymax Corporation offers a one-year warranty against defects in material and
workmanship on all system components with proof of purchase date. Unauthorized repair, modification, or
improper use of equipment may void your warranty benefits. The use of aftermarket replacement parts not
supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to
the equipment.
IMPORTANT NOTE:
DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES,
EXPRESSED OR IMPLIED, DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT
WITHOUT WRITTEN AUTHORIZATION FROM DYMAX. THOSE CORRECTIVE ACTIONS LISTED ABOVE ARE LIMITED
TO THIS AUTHORIZATION.

© 2012 Dymax Corporation. All rights reserved. All trademarks in this guide, except where noted, are the property of, or used under license by Dymax Corporation, U.S.A.
Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited
to that contained in Dymax’s standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to insure that desired performance criteria are satisfied. Dymax is willing to assist users in their
performance testing and evaluation by offering equipment trial rental and leasing programs to assist in such testing and evaluations. Data sheets are available for valve controllers or pressure pots upon request.
PN39574 MAN005 9/14/2012
Dymax Oligomers & Coatings
Dymax Asia (H.K.) Limited
Dymax UV Adhesives & Equipment (Shanghai) Co. Ltd.
+86.21.37285759 | dymaxasia@dymax.com | www.dymax.com.cn
Dymax Asia Pacific Pte. Ltd.
Dymax Engineering Adhesives Ireland Ltd.
Dymax UV Adhesives & Equipment (Shenzhen) Co. Ltd.
Dymax Korea LLC
+82.2.784.3434 | info_kr@dymax.com | www.dymax.com/kr

Artisan
Technology
Group
is
an independent supplier
of
quality pre-owned equipment
Gold-standard
solutions
Extend the life
of
your
critical industrial,
commercial, and military systems
with
our
superior service and support.
We
buy
equipment
Planning to
upgrade
your current
equipment? Have surplus equipment taking
up shelf space? We'll give it a
new
home.
Learn
more!
Visit us at artisantg.com for more info
on price quotes, drivers, technical
specifications, manuals, and documentation.
Artisan Scientific
Corporation
dba
Artisan
Technology
Group
is
not
an affiliate,
representative,
or
authorized
distributor
for
any
manufacturer
listed herein.
We're here to make your life easier.
How
can
we
help you today?
(217)
352-9330
Isales@artisantg.com Iartisantg.com