
W
gltrltftO
4.0
DY4000
Manual
&Automatic
CloseTimers
Settingthe
Manual
&Automatic
GloseTimers
TheDynalogixllhas
twoautomaticclosetimers.Thefirsttimer,MG/PB
timer,
willcountdown
afteraactivation
is
installedonterminalnumber2 (most
commonly
usedfor
pull
cordsor
pushbuttons).
MC/PB
timeralsocanbe
turnedonoroff,makingitmanual
operationorautomaticoperationsimplyby
assigningacountdown
value
tothetimer.Thesecondtimer,AC/Looptimer,
will
countdownafter
aactivationisinstalled
onterminal4 (most
commonly
usedaremotionsensorsandloops).lfthis
timer
is
setto
zero,
thedoorwill
comedownafterdoorreaches
upper
limit.
4.1 Setting
MC/PBTimer
'1.
Press
and
releaseMC/PBTimer
buttonontheDynalogixllcontroller.
The
display
will
changeto:MCDelay_Time=##.
See
figure4.1-1.
MC/PB
Timer
Figure
4.1-1:MC/PBTimer
2. UsetheUpandDownarrowbuttonsto
changethecountdowntimetothe
desiredduration.TheDynalogixllwillautomatically
saveanychangesthat
aremade.Seefioure4.1-2.
lncrease
Setting
Decrease
Setting
Figure4.1-2:
Raise/LowerManualTimers
-ffifih?i:
-Wil @ V
M!NU- '"rr* |
8
DYNACO
USA,INC, 7/e.4a&n caDaazSd/4rq ADear:fn