Features:
• Multi-Functional 2-Way Cabinet
• 500 W, 8 Ohms
• 90° x 50° Coverage Pattern
• 97 dB Sensitivity, 130 dB Maximum SPL
• Crossover with HF Protection
• SMX2120 LF Transducer
• DH3 Compression Driver
• Pole Mount for Tripod Use
• M8 Threaded Points
• Mounting Points to attach optional Mounting
Bracket
Technische Informationen
Engineering Data Sheet
C 12.2
12“ / 1.25“
2-Way Fullrange Cabinet
Wir weisen ausdrücklich darauf hin, dass bei
gehängten Lautsprecherboxen die einschlägigen
Sicherheitsbestimmungen zu beachten sind. Es
muss unbedingt qualifizierte Fachberatung in
Anspruch genommen werden!
We expressly point out that the relevant safety
regulations must be observed for “flying”
loudspeaker systems. It is imperative that quali-
fied expert advice is sought.
C 12.2
Order No. F01U165091
Cabinet Fullrange
Configuration Passive 2-Way
Nominal impedance 8 Ohms
Minimum Impedance 5.7 Ohms
Rated Power RMS 500 W
Peak Power 2000 W
Sound pressure level
SPL 1 W / 1 m 97 dB
Max. SPL 1 m (calculated
with peak power)
130 dB
Frequency Range (-10 dB) 60 Hz to 20 kHz
Nominal Coverage Angle
(Horizontal x Vertical)
90° x 50°
X-Over Frequency 1650 Hz
LF Transducer SMX2120, 12‘‘ (305 mm) Driver
HF Transducer DH3, 1.25‘‘ (32 mm) Diaphragm
Compression Driver
Connectors 2x Neutrik Speakon NL4
Full-Range 1+ / 1-
Wired through 2+ / 2-
Dimensions (W x H x D) 387 mm x 550 mm x 374 mm
(15.2“ x 21.7“ x 14.7“)
Net Weight 20.7 kg (45.6 lbs)
Shipping Weight 23.3 kg (51.4 lbs)
Enclosure material MDF with D-PUR PLUS
Grille Steel, Black Finish with Acoustic Gauze
Suspension 3x M8 Threaded Points - 1x on Each Side
and 1x on the Rear of Enclosure
Warranty 5 years
Optional Accessories
DC-MBC12-UMH F01U169670
TMA Tilt Angle for UMH F01U118977
RMA Rotatable Mounting kit F01U118976
TC-02 Truss clamp F01U100657
EBK-M8 Eye Bolt Kit F01U166797
Spare Parts
LF Transducer F01U134308
HF Transducer F01U103119

Beschreibung Description
Die C 12.2 ist eine kompakte, trapezförmige 12“ / 2-Weg Fullrange Box mit einer sehr
hohen Belastbarkeit von 500 W Continuous / 2000 W Peak und einem Wirkungsgrad von
97 dB 1W / 1m. Im Tieftonbereich kommt ein SMX 2120 Woofer zum Einsatz, im Hoch-
tonbereich arbeitet ein DH3 Compression-Treiber in ein 90° x 50° Constant Directivity
Horn für den Frequenzbereich oberhalb 1650 Hz. Flugpunkte für Eyebolts erlauben ver-
tikale oder horizontale Aufhängung. Zusätzlich ist optional ein Montagebügel (DC-
MBC12-UMH) erhältlich, der kompatibel zum DYNACORD PI-Easy Montagesystem ist
und eine Ausrichtung in bis zu drei Ebenen erlaubt. Zur Erweiterung der Tiefbass-Perfor-
mance wird ein parallel geschalteter Sub 1.15 Subwoofer empfohlen. Diese Kombination
ist auch ideal für ein Aktiv-2-Weg System zusammen mit den Controllern DSP 260 oder
DSP 600 und Endstufen der SL-Serie geeignet.
The C 12.2 is a compact, trapezoidal 12” / two-way full-range cabinet offering very high
power handling (500 W continuous / 2000 W peak) and sensitivity of 97 dB 1W / 1m.
The low frequencies are transduced by an SMX 2120 woofer, whilst in the high frequency
range, a DH3 compression driver in a 90° x 50° constant directivity horn handles every-
thing above 1650 Hz. Flying points for eyebolts allow the cabinets to be flown vertically
or horizontally. Available as an option is the DC-MBC12-UMH mounting bracket, which is
compatible with the DYNACORD PI-Easy mounting system and supports up to three levels
of orientation. To extend the low bass performance, a Sub 1.15 subwoofer connected in
parallel is recommended. This combination is also ideal for an active two-way system
together with the DSP 260 or DSP 600 controllers and power amplifiers from the SL
series.
Illustration 1: Dimensions

Illustration 2: Frequency Response
20 100 1k 10k 20k
60
65
70
75
80
85
90
95
100
105
110
f / Hz
SPL / dB
Frequency Response, 1/6 Oct.
20 100 1k 10k 20k
1
2
5
10
20
50
100
200
f / Hz
|Z| / Ω
Impedance, 1/6 Oct.
20 100 1k 10k 20k
10
20
30
40
60
80
100
200
360
f / Hz
φ/ deg
−6dB Beamwidth, 1/1 Oct.
horizontal
vertical
20 100 1k 10k 20k
0
5
10
15
20
25
DI / dB
Directivity Index DI, Directivity Factor Q, 1/1 Oct.
1
2
5
10
20
50
100
200
Q
f / Hz

Illustration 3: Block diagram
Illustration 4: Horizontal Directivity
Horizontal Directivity, 3dB/Div, 30dB Radius, 1/1 Oct.
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
63 Hz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
125 Hz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
250 Hz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
500 Hz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
1 kHz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
2 kHz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
4 kHz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
8 kHz
0°
30°
60°
90°
120°
150°±180°−150°
−120°
−90°
−60°
−30°
16 kHz

Rigging
Illustration 5: Vertical Directivity
Vertical Directivity, 3dB/Div, 30dB Radius, 1/1 Oct.
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
63 Hz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
125 Hz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
250 Hz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
500 Hz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
1 kHz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
2 kHz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
4 kHz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
8 kHz
0°
30°
60°
90°
120°
150°
±180°
−150°
−120°−90°−60°
−30°
16 kHz
Illustration 6: Remove the M8 Screws from
the Loudspeaker, then install the Washers
and Eyebolts (EBK-M8 Eye Bolt Kit) to the
Loudspeaker
Illustration 7:Eyebolts shown
oriented in the plane of pull
(CORRECT)
Illustration 8: Eyebolts not
oriented in the plane of pull
(INCORRECT)
Washer has
to be used

12000 Portland Avenue South, Burnsville, MN 55337, USA Europe, Africa, and Middle East only. For customer orders, contact Customer Service at:
Phone: +1 952/844-4051, Fax: +1 952/884-0043 +49 9421-706 0 Fax: +49 9421-706 265
Asia & Pacific only. For customer orders, contact Customer Service at:
www.dynacord.com +65 6571 2534 Fax: +65 6571 2699
For technical assistance, contact Technical Support at: +49 9421-706 0
© Bosch Communications Systems 09/2010
Part Number F01U163336 Vs 01 Specifications subject to change without notice.
CAUTION: Eyebolts must be fully seated and orient in the plane of pull as shown. Always use washers
under the eyebolt to distribute the load on the enclosure.
Illustration 9: Vertical orientation Illustration 10: Optional Accessories
RMA
MBC12-UMH
TMA
Table of contents
Other Dynacord Enclosure manuals