Guide
4
Flash control
Overload and overheat protecon
Starter SK studio ash has power range from 1/1 to 1/8 (4 EV), which can be adjusted through the ash
output controller 8 (see pic. 2) in 20 steps and it’s shown on the digital display 2 with numbers from 1.0 to
3.0. Up arrow buon serves to increase the power output, respecvely, the one with arrow down serves to
decrease the power output. Please noce, that aer decreasing the power output you need to re the ash
ones to discharge the capacitors to the set lower power. If you reduce the power output with one more
increment under 1.0, the digial display will show “OF” symbol and the ash will stay turn on, but it won’t
be able to re a ash.
Starter DE studio ash has fully manual control of the modeling light. To turn on or o the modeling lamp,
press the buon 3. You can steplessly control the modeling lamp in 9 steps, which will be shown on the back
panel with the symbols L1 tо L9. For this purpose hold the buon 3, unl the modeling lamp power output
indicaon shows on the back panel and start blinking (L1 до L9). Through the buons 8 adjust the power
output and when it’s done , press once the buon 3. When the ash is on and idle for more than two hours
, the modeling lamp will automacally turn o. Restart the ash to turn it back on.
During connious work with the ash (large number of ashes for a short term), an overheang may occur.
To protect the ash, don’t make more than 20 ashes in a row with higher power output (2.0 - 3.0). Aer
every 20 conguous ashes leave the ash to cool down for at least 3 min.
When working with light control accessories such as spots, which are prevenng the cooling, you have to
limit the modeling light use and the ash shouldn’t be used too intense.
If the ash is used carelessly about its temperature this may cause failure, in which case Dynaphos Ltd.
reserves the right to refuse warranty repair.