E-line ELI-ANPTZ-56-37R User manual



Welcome
Thank you for purchasing our product. If there is any question or request,
please do not hesitate to contact us.
This manual is applicable to Speed Dome.
This manual may contain several technically incorrect places or printing
errors, and the content is subject to change without notice. The updates will be
added into the new version of this manual. We will readily improve or update
the products or procedures described in the manual.

eLineTechnology.com 2
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger or
property loss.
The precaution measure is divided into “Warnings” and “Cautions”:
Warnings: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings
1. In the use of the product, you must be strict compliance with the electrical safety regulations of the
nation and region.
2. Please use the power adapter, which is provided by normal company. The standard of the power
adapter is DC12V/4A.
3. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire
hazard.
4. Please make sure that the plug is firmly connected on the power socket.
5. When the product is installed on wall or ceiling, the device shall be firmly fixed.
6. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable,
and then please contact the service center.
7. If the product does not work properly, please contact your dealer or the nearest service center. Never
attempt to disassemble the camera yourself. (We shall not assume any responsibility for problems caused
by unauthorized repair or maintenance.)
Cautions
1. Do not drop the dome or subject it to physical shock, and do not expose it to high electromagnetism
radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance
can cause equipment damage).
2. Do not place the dome in extremely hot, cold (the operating temperature shall be -30°C ~ +65°C), dusty
or damp locations, or fire or electrical shock will occur otherwise.
3. The dome cover for indoor use shall be kept from rain and moisture.
4. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is
forbidden (ignorance can cause fire danger).
Warnings Follow these safeguards
to prevent serious injur
y
or death.
Cautions Follow these precautions
to prevent potential injur
y
or material

eLineTechnology.com
3
5. Do not aim the camera at the sun or extra bright places. A blooming or smear may occur otherwise
(which is not a malfunction however), and affecting the endurance of CCD at the same time.
6. Please use the provided glove when open up the dome cover, avoid direct contact with the dome cover,
because the acidic sweat of the fingers may erode the surface coating of the dome cover.
7. Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover, not to use
alkaline detergents.

eLineTechnology.com 4
Catalog
Chapter 1 Brief Introduction......................................................................................................5
1.1 Description....................................................................................................................5
1.2 Functions ......................................................................................................................6
Chapter 2 IR Speed Dome Installation...............................................................................10
2.1 Install Preparation......................................................................................................10
2.2 Installation...................................................................................................................11
2.3 Default Setting............................................................................................................12
2.4 DIP SWITCH SETTING ............................................................................................12
2.5 Alarm Wire Diagram ..................................................................................................13
Chapter 3 Installation Description ..........................................................................................14
3.1 Bracket Dimension ....................................................................................................14
3.2 Wall Mount..................................................................................................................14
3.3 Ceiling Mount bracket Installation ...........................................................................15
3.4 Pole Mount..................................................................................................................15
3.5 Corner Mount .............................................................................................................16
Chapter 4 Operation ................................................................................................................17
4.1 POST( Power On Self Test).....................................................................................17
4.2 Basically Operation....................................................................................................17
4.3 SPECIAL FUNCTION PRESET...............................................................................18
4.4 Screen Character prompted .....................................................................................19
Chapter 5 Menu Guide ............................................................................................................20
5.1 Menu operation guide ...............................................................................................21
5.2 Main Menu and System Information .......................................................................22
5.3 FUNCTION SETTING ...............................................................................................23
Lightning and Surge Protection ..............................................................................................35
Appendix RS485 Bus-mastering knowledge....................................................................36
Appendix Simple Trouble Shooting Table .....................................................................37
Appendix III The relationship between Wire and Distance.................................................38
Appendix IV AWG sheet at Home and Abroad .................................................................39
Appendix V Address Coding Table .....................................................................................41

eLineTechnology.com
5
Chapter 1 Brief Introduction
1.1 Description
Speed Dome is new products model which features built-in Auto focus camera module. Inner Pan/tilt
integrated with digital decoder which support line fault diagnosis, and 3D position function. Speed dome set
up the precision sensitive and stability motor gives camera no shake in any level speed.
Speed Dome is via digital control with precis simple drive system. The function is not only realize the
presets; horizontal scanning;frame scanning;following scanning, and panoramic scanning but also realize
the manual limit position;auto flip;privacy mask;and backlight compensation. The personal privacy is given
the best protection when the speed dome works on no blind spot panoramic monitoring.
IR Speed Dome support PELCO-D;PELCO-P,TA protocol ..etc, and it can match protocol
automaticly. To convenience to user, the speed dome capability with hardware dip address and software
address. User can config the System Information; Display; Camera Settings; Presets Settings; Mode
Settings; Alarm Settings; Auxiliary Switcher Settings ..etc via the Muti-language Menu.
1. Infrared Function
Quickly cooling cast aluminum design.
CCVE and PWM design, IR LED can work steady in long time.
IDS (Intelligent Dimmer System), The IR brightness can be fixed by distance, zoom and brightness of
picture.
Individual MCU infrared control system, The muti mode and remote upgrade system can be configured
Multi-mode infrared settings, unique MCU IR control system,Remote upgrade system.
10 grade IR power and illumination can be set.
Perfect IR vision via internal switch between IR control and camera module optical filter .
IP 66 Grade,TVS 4,000V lightning protection and voltage transient protection.
3 Channel temperature control system, detect the camera and IR LED temperature.
2. System Function
Integrate Structure Design.
CGS (Cooling GAS System).
IP 66 Grade,TVS 4,000V lightning protection and voltage transient protection.
3 Channel temperature control system, detect the camera and IR LED temperature.
Multi-Axis Design.

eLineTechnology.com 6
Heat balance device built in, fog proof.
Precise motor device which sensitively and steady. The accuracy deviation >0.1, no picture shake.
Support online upgrade , reduce the service cost
Support 3D Positioning Function
Easy setting for DIP and Protocol
Friendly Graphical User Interface Menu
Support Preset / Patrol / Pattern / Linear scan / Frame
Support Title Display
Support Menu Code Protection
Low Consumption Design
3. PTZ Function
Pan: 0°~360°endless, Tilt: -5°~90° auto flip 180° to continue monitor.
255 presets, Power off Memory.
Support 4 preset cruise scanning, It can be added 32 presets in every cruise scanning.
Support pattern scanning, Recording time is from 10 min to 1000 min.
Support Proportional Pan/Tilt Zoom, rotation speed can fix automatically with lens zoom.
Built-in RTC clock, support 16 timing task, individual execute cycle can be set.
4. Built-in HD camera module
Auto IRIS and BLC
Auto/Manual white balance
Auto/Manual Focus
Auto brightness control
1.2 Functions
Multi-lingual OSD Menu: The dome provides multi-lingual OSD menu for display of system
information and setting of dome parameters.
Self-adaptive to Multiple Protocols:The dome is compatible with PELCO-D, PELCO-P, TA,HIK
and DH, etc., and is capable of being self-adaptive to these protocols without need of selecting
protocol by DIP switch settings.
Control:The pan/tilt movement and zoom actions of dome can be controlled by the control keyboard,
DVR, matrix, etc.
Limit Stops:The dome can be programmed to move within the limit stops (left/right, up/down) which
are configurable by the control keyboard, DVR or client application software.
Auto Scan:The dome provides 5 scanning modes: pan scanning, tilt scanning, frame scanning,
random scanning and panorama scanning. The scanning speed can be set by OSD menu from level

eLineTechnology.com
7
1 to 40, with the corresponding speed ranging from 1°/second to 40°/second.
Presets:Each of the user-definable presets can be programmed to use pan, tilt, camera settings and
other settings. When preset is called, the dome will automatically move to the defined position. User
is allowed to add, modify, delete and call each preset.
Label Display:The on-screen label of the preset title, azimuth/elevation, zoom and other operations
can be programmed by menu and displayed on the monitor.
Auto Flip:In manual tracking mode, when a target object goes directly beneath the dome, the dome
will automatically rotate 180 degrees in horizontal direction to maintain continuity of tracking. When
the dome rotates (flips), the camera starts moving upward as long as you continue to hold the
joystick in the down position. This function can be realized by image center flip depending on
different camera models. The feature can be enabled/disabled through the menu.
Privacy Mask:The privacy mask allows a user to program user-defined areas that cannot be viewed
by the operator of the dome system. A masked area will move with pan and tilt functions and
automatically adjust in size as the lens zooms telephoto and wide.
3D Intelligent Positioning:The speed dome can be controlled with the 2 buttons and scroll of
mouse can be used under protocols with devices and client software. Click on a certain area and the
device will move to the scene with corresponding point as the center. When a rectangular area is
selected by left-clicking the mouse, device will move to its center and enlarge it. With right-clicking,
the lens will zoom in, and the scroll can easily make the lens zooming, and mouse operation
automatically incorporates zooming effect.
Proportional Pan/Tilt:Proportional pan/tilt automatically reduces or increases the pan and tilt
speeds in proportion to the amount of zoom. At telephoto zoom settings, the pan and tilt speeds will
be slower for a given amount of joystick deflection than at wide zoom settings. This keeps the image
from moving too fast on the monitor when there is a large amount of zoom.
Auto Focus:The auto focus enables the camera to focus automatically to maintain clear video
images. In manual mode, it can controlled by "Near" and "Far". When the PTZ moving or lens
zooming, the manual mode will back to Auto fucus mode
IR Cut Filter:The IR cut filter can be set to Auto, Day and Night. In auto mode, the camera is
capable of automatically switching Black & White mode (Night) and Color mode (Day) with regard to
environment lightening conditions. In manual switch mode, user can increase sensitivity in low light
conditions by switching to Black & White mode, while the Color mode is preferred in normal lighting
conditions.
Low Light Electronic Shutter:The shutter speed will automatically slow down in low illumination
conditions to maintain clear video images by extending the exposure time. The feature can be

eLineTechnology.com 8
enabled/disabled by the menu.
Backlight Compensation (BLC):If a bright backlight is present, the subjects in the picture may
appear dark or as a silhouette. Backlight compensation (BLC) enhances objects in the center of the
picture. The dome uses the center of the picture to adjust the iris. If there is a bright light source
outside of this area, it will wash out to white. The camera will adjust the iris so that the object in the
sensitive area is properly exposed.
White Balance (WB):This feature automatically processes the viewed image to retain color balance
over a color temperature range. The default setting for white balance is AUTO.
Support 4 preset cruise scanning: It can be added 32 presets in every cruise scanning
Pattern: A pattern is a memorized, repeating series of pan, tilt, zoom, and preset functions that can
be recalled with a command from a controller or automatically by a configured function (alarm, park,
time task, or power-up). By default the focus and iris are in auto status during the pattern is being
memorized.
Power Loss Position: The dome supports the power loss position capability with the predefined
dwell time. It allows the dome to resume its previous position after power is restored.
Patrol: The high speed dome provides up to 8 patrols. In each patrol, user is allowed to specify the
scanning track by a group of user-defined presets, with the scanning speed between two presets
and the dwell time at the preset separately programmable.
Alarm Response Action: The speed dome supports 4 alarm inputs which can be set to NO
(normally open), NC (normally closed). Upon having received the alarm input signal, the dome will
automatically activate a user-defined action, which can be programmed to patrol, pattern or preset
call up.
AUX Output: An auxiliary output is a configurable signal from the dome back box that can trigger
another device to operate. The dome provides 1 auxiliary outputs: AUX1. The auxiliary output type
can be set to NO or NC by menu. And the alarm dwell time is configurable as well.
Timing Tasking: The speed action can be preset in some period, in including: preset 1-8, pattern
1-8, cruise 1-8, Pan scanning...etc.
Zone Function: It including Zone function operation, Zone name setting, Zone action,Zone Setting,
and Zone delete. Zone action: When the camera stop in some zone without any command for more
than 4 min, the Pan&Scan will be enabled in this zone.
Code Protection: Right code must be input for following speed dome configuration
Compass Function: It is display the specific location. The zero azimuth is regarded as North in
general rule.

eLineTechnology.com
9
Following is the Diagram:
Display N NE E SE S SW W NW
Means North North
East
East East
South
South West
South
West West
North
485 Fault Detect: The speed dome will display the fault case when there is some fault between
control side and receiver side. For example: The fault of camera, motor,communication and IR etc.
will display on screen with some special characters.
Software protocol: The protocol can be configurated via speed dome menu.

eLineTechnology.com 10
Chapter 2 IR Speed Dome Installation
2.1 Install Preparation
1. Basic Requirement
Before the installation, please read following caution information:
1) Installation and maintenance should be carried out by professional personnel as per relative
regulations. All electrical work must obey the latest electrical regulations, fire regulations and
relevant regulations. Check whether the accessories of the unit are complete according to
packing list and confirm whether the place and method of installation is in accord with required, if
not, please contact your supplier. Please use this product in required environment.
2) Indoor IR intelligent high-speed dome only designs for house supply. It can’t be installed exposed
to rain or in very humid place.
3) After re-installation or repair, you need to measure the resistance between the circuit and shell to
check whether the insulation is good, and ensure there is no short-circuit between the circuit and
shell.
4) Confirm there is enough place to contain the product and its structure components. Confirm the
ceiling, wall and bracket for installation can take the total weight of the product and its structure
components, and materials used to support the weight can sustain four times the weight of the
product.
5) Please refer to following table of work environment:
2. Preparation of wire
1) Choose the right wire according distance.
Minimum requirement of Coaxial Cable: 75Ωimpedance; full Copper Core; and 95% Braided
copper network shielding
National Mode International Mode Max Distance(M/ft)
RG59/U RG59/U 229m(750ft)
5C-2V RG6/U 305m(1000ft)
7C-2V RG11/U 457m(1500ft)
Temperature -40~60
Atmospheric
Pressure
86~106KPa
Humidity <90%RH Power DC12V/4A

eLineTechnology.com
11
2)Following is recommend Max distance for 12VDC. Please refer the Appendix 3 Wire
Gauge&Transmission Distance
Cable Diameter Max Distance(M/ft)
0.75mm26m(20ft)
1mm29m(30ft)
1.5mm212m(40ft)
2mm215m(50ft)
3. Please keep the product package well
Please keep the product package well, You can send the speed dome to factory with that package if there
is any problem need to service.
2.2 Installation
1. Speed Dome Installation
Different Bracket install way please refer to chapter 2 and chapter 3
1) Take out the cable from the speed dome.Remove the connected cover from speed dome, and put
the wire though the bracket. Connect the bracket and cover with 3 pcs screws, and fix it to
wall.( As pic 2.2.1) (Caution: The bracket must be with waterproof fodder together)
2) Open the Dip Switch Cap with screw driver. Configure the protocol,Baud rate, and Speed Dome
address. ( As pic 2.2.2). Please refer the chapter 2.4" Dip Switch Setting"
3) Remove the protect gummed tape (As pic 2.2.3), check the situation of seal ring on top of speed
dome.
4) Connect the safe rope of speed dome to the bracket, then hook up speed dome to the connected
cover( As pic 2.2.4). You should plugged the cable into right pin by reference by cable mark(As
pic 2.2.5).
5) Fix the speed dome with the screws.
2.2.1 2.2.2 2.2.3

eLineTechnology.com 12
2.2.4 2.2.5 2.2.6
2.3 Default Setting
Protocol: Auto Match
Address: No.1
Baud rate: 2400-N-8-1
120Ωohmic resistance:
2.4 DIP SWITCH SETTING
Before install the speed dome, please configure the protocol, baud rate, and speed dome address.
The Dip switch is on side of speed dome( Analog speed dome As pic 2.4.7) or in the connected cover( IP
speed dome as pic 2.4.8)
2.4.7 Diagram of Analog Speed Dip Switch Pic 2.4.8 Diagram of IP Speed Dome Dip Switch
SW1 Configure speed dome protocol , baud rate and 120Ωohmic resistance; SW2 configure speed
dome communicated address.
SW1 Protocol&Baud Rate Switch SW2 Speed Dome Address
E.g. Some parts of Dip for Protocol&Baud Rate
Auto Match PELCO-D&2400BPS PELCO-P&9600BPS

eLineTechnology.com
13
1) Protocol Rule
Protocol SW1-1 SW1-2 SW1-3
Auto Match/PELCO-D OFF OFF OFF
TA OFF OFF ON
PELCO-P ON OFF OFF
Save …… …… ……
2) Baud Rate Rules
Baud Rate SW1-4 SW1-5
Auto Match/1200BPS OFF OFF
2400BPS ON OFF
4800BPS OFF ON
9600BPS ON ON
3) 120Ωohmic resistance Configuration
SW1 is the 120Ωohmic resistance of RS485. Please configure it as the 《Appendix 2 RS485 BUS
Connection》.
4) Communicated Address Configuration
SW2 configure the Speed Dome address. The speed dome address is binary system, No.8 is MSB,
No.2 is the LSB. PELCO-D/TA please refer as Appendix 5 <Table of Address Code> .
2.5 Alarm Wire Diagram
Speed Dome support 4 channel alarm output and 2 channel input; Following is the diagram.
Port Name Description
COM1 Alarm Output Channel , 1 Common Port
NO1 Alarm NO Output Channel 1
COM2 Alarm Output Channel 2 Common Port
NO2 Alarm NO Output Channel 2
GND Alarm Output GND
IN 4 Alarm Input Channel 4
IN 3 Alarm Input Channel 3
IN 2 Alarm Input Channel 2
IN 1 Alarm Input Channel 1
GND Alarm Input GND

eLineTechnology.com 14
Chapter 3 Installation Description
3.1 Bracket Dimension
Wall Mount Dimension Ceiling Mount Dimension
PoleMountDimension CornerMountDimension
3.2 Wall Mount
1)Accessories Installation
WallMountBracket Washer&ScrewCap

eLineTechnology.com
15
2)Mount Step
3.3 Ceiling Mount bracket Installation
1)Accessories Installation
Ceiling Mount Bracket ( length Optional) Washer&Screw Cap
2)Mount Step
3.4 Pole Mount
1)Accessories Mount
Wall Mount bracket Pole Mount bracket Fastener Washer,Screws&crew Cap

eLineTechnology.com 16
2)Mount Step
3.5 Corner Mount
1)Accessories Mount
WallMountbracket Corner Mount bracket Washer,Screws&crew Cap
2)Mount Step

eLineTechnology.com
17
Chapter 4 Operation
4.1 POST( Power On Self Test)
The Speed Dome Power on, execute the self test. The steps: System preheat( If it is necessary),
camera test,Pan test, Tilt test. The Self Test display as pic 5.1.1, it is takes 40 sec.
Note: If the speed dome address is unavailable, the address display the software address, otherwise
it will display the address which configured by Dip Switch, The operation of speed dome software address,
please referenced by chapter5.3.6. The communication bar show the information of communication
speed , date bits, stop bits etc. E.g."2400.N,8.1" means the communication speed is 2400Bps, None
Check, 8 bits, 1 stop bits.
Pic 5.1.1 Splash Screen
4.2 Basically Operation
Following is the integrated operation with the Keyboard,DVR, and software etc.It is normally
operation. Please referenced by User Manual
Pan/Tilt: Control the joystick of Keyboard to expected direction, or enable KEY of UP , DOWN,LEFT,
RIGHT .
ZOOM Control: Control the Key of TELT and WIDE from Keyboard and DVR to enable camera
ZOOM IN and ZOOM OUT.
FOCUS: Control the Key of FAR and NEAR from Keyboard and DVR to enable camera FOCUS.In
the AUTO mode, the camera will FOCUS Automatically. The manual FOCUS mode will back to
AUTO FOUCS MODE if the speed dome is operated by manual.
IRIS: Control the Key of OPEN and CLOSE from Keyboard and DVR to enable camera IRIS Control.
The Manual IRIS mode will back to Auto Mode if there is manual operation for Speed Dome.

eLineTechnology.com 18
PRESET: The Speed Dome support 255 presets. The setting and operation, please reference by
Chapter 5.3.
4.3 SPECIAL FUNCTION PRESET
Call Preset Function Call Preset Function
33 Auto Flip 93 Limited Direction of
UP,DOWN,LEFT,RIGH
T Setting
34 Back to Zero Point 94 Remote Reboot
35 Preset Scannin
g
1 95 Call Menu
36 Preset Scannin
g
2 96 Sto
p
Preset Scannin
g
37 Preset Scannin
g
3 97 Random Preset
38 Preset Scannin
g
4 98 Frame Scannin
g
39 Da
y
Mode 99 Pan Scannin
g
40 Ni
g
ht Mode 100 Tilt Scannin
g
41 Pattern Scannin
g
1 101 Panoramic Scannin
g
42 Pattern Scannin
g
2 102 Preset Scannin
g
5
43 Pattern Scannin
g
3 103 Preset Scannin
g
6
44 Pattern Scannin
g
4 104 Preset Scannin
g
7
92 Limit Direction Settin
g
105 Preset Scannin
g
8
5.3.1 Grade 1 Special Function Preset
Call following preset can enable relevant function. E.g. Call Preset 99 can enable Pan Scanning.
Grade 1 Grade 2 Specification of Special Preset Function
49
1 Grade 1 of IR Sensitivity (Highest)
2 Grade 2 of IR Sensitivity
3 Grade 3 of IR Sensitivity
4 Grade 4 of IR Sensitivity
5 Grade 6 of IR Sensitivity
6 Grade 6 of IR Sensitivity ( Lowest)
7 IR LED ON
8 IR LED OFF
9 AUTO IR LED ON/OFF
50 AUTO SWITCH HIGH AND LOW IR
56 INITIALIZE IR SYSTEM
57 LOW IR BEAM MODE
58 ALL IR LED ON
59 HIGH IR BEAM MODE
131 INITIALIZE WHOLE SPEED DOME
40 SPEED LIMIT IN 40 DEGREE/SEC
70 SPEED LIMIT IN 70 DEGREE/SEC
150 SPEED LIMIT IN 150 DEGREE/SEC
250 SPEED LIMIT IN 250 DEGREE/SEC
Table of contents