13. Test Procedure: Make
certain that all discharge
shuto valves are fully open
(curb stops, slider valve, etc.).
Turn o power at main power
supply and panel. (Ignore all
Trouble indications, LEDs and/
or messages until the panel
is reset at the end of this
procedure.)
Use an ohmmeter set at
the 2 meg scale. Check
the continuity between the
following leads from the pump
(tests should be performed with
the pump and alarm breakers
inside the panel OFF):
•Green/yellow to red
•Green/yellow to black
•Green/yellow to brown
•Brown to yellow
All of these tests must read
an open circuit. A short at any
of these test points will cause
premature pump failure if not
corrected.
Turn on power at main power
supply only. Check voltage
from the main power supply.
The voltage must be 240 VAC
(or 120 VAC for a 120V model)
within 10 percent. Note the
voltage.
Turn on the alarm power
circuit breaker. Leave pump
breaker o.
Fill tank with water until
alarm turns on. This will be
about 30 inches from bottom
of tank. Turn o water. Turn on
pump power circuit breaker.
Pump should immediately
turn on. Within one minute the
alarm will turn o. Within three
minutes the pump will turn o.
Take a current (amperage)
reading o the black lead to the
pump. The reading should be
between 5 and 8 amps for 240
VAC service (10 to 16 amps for
120 VAC service).
Higher amperage readings
equal a higher discharge
pressure. If the amperage is
greater than 8 (16 for 120 VAC
service) check the discharge
line for a blockage. Note the
amperage.
Within the rst 1 to 3 minutes,
the alarm will turn o. Within
the following 1 to 2 minutes,
the pump will turn o (in a 24-
inch diameter tank).
Clear/Reset the alarm panel:
• Sentry and T260 panels:
Reset is not required.
• Protect Panel: Turn pump
and alarm breakers o and
back on simultaneously.
• Protect Plus Panels:
Perform a “cold start” from
the Initialize System menu.
Any user setting that were
previously chosen will not
be reset.
If any Trouble or alarm
conditions are indicated after
the panel is reset, contact your
local service provider.
Close and lock the alarm
panel.
Inspect the lid gasket and
install new gasket material as
required. Fasten lid to tank.
Call your local E/One
distributor if you experience
any problems. Please have
ready the unit serial number,
voltage, amperage read during
startup, type of application, and
a description of the problem.