1. Introduction
The Thermal Imager is handheld imaging camera used for predictive maintenance,
equipment troubleshooting, and verification. Thermal images are displayed on the LCD
and can be saved to internal memories. With Bluetooth instant share function, thermal
images can be transferred to smart phone for analyse,share and report quickly.
1.1. Key features
80x80 pixel thermal imaging system.
6400 points real temperature fast measurements
Hot,Cold,Center three temperature tracking function.
Large, easy-to-read, bright graphical TFT display
50Hz fast Thermal image frame rate
Bluetooth image instant share & save with iOS and Android smart device
Scene temperature range Lock function.
With LED flashlight function
Long running time up to 8 hours with rechargeable battery.
Smart and compact design
Rugged industrial design
Safety
1.2. safetyinfomation
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to avoid personal
injury or damage to the meter.
1.3. Cautions
Improper use can damage the meter. Please read and understand all of the
information provided in this User Guide and other included documentation before use.
Refer to the CAUTION statement label (shown below) for critical safety information.
EASTERN ENERGY CO.,LTD. (HEAD OFFICE)
40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170
Contact :
www.ete.co.th

d
e
s
c
r
e
R
T
s
a
t
o
d
s
c
h
o
a
W
U
s
o
s
y
2. Quic
k
2.1. Bas
The ther
m
e
tail later i
1.
c
reen will
e
fer to Se
c
2.
R
elative te
m
emperatu
r
a
me time
t
3.
S
o
share th
e
4.
P
iscard.
2.2. Po
w
Pr
e
c
reen (a t
h
o
ld for >
utomatical
Wi
t
W
hen batt
e
U
SB cable
(
Wi
t
o
urce or c
o
Th
e
y
mbol i
s
k
Start
G
ic step
m
al image
r
n this Gui
d
Press an
d
appear f
o
c
tion 3.2 b
e
Point the
m
perature
r
e reading
t
he hot an
d
S
hort trigg
e
e
image wi
t
P
ress“LOC
w
ering an
d
e
ss and h
o
h
ermal im
a
2 secon
ly after a
p
t
h the po
w
e
ry power i
s
(
USB port
t
h power
o
nnected
t
e
unit can
s
animated
G
uide
r
is intuiti
v
d
e):
d
hold the
o
llowed by
e
low.
unit towa
r
is repres
e
represent
d
cold poi
n
e
r to freez
t
h smart d
e
K” to Lo
c
d
chargin
g
o
ld the p
o
a
ge) will
a
ds. Note
p
rogramm
e
w
er ON, th
e
s
low, con
n
is located
OFF, the
t
o a comp
u
also be
p
on the ful
l
v
e and ea
s
Power b
u
the ther
m
r
d the ar
e
e
nted by
c
s the tem
p
n
t tempera
t
e/capture
t
e
vices. Tri
c
k current
g
the ther
m
o
wer butto
a
ppear. Th
that the
e
d period
o
e
battery
s
n
ect to an
at top of t
h
battery c
h
u
ter USB
p
p
owered u
p
l
screen
s
y to use;
u
tton for >
m
al image
e
a or obje
c
c
olor, hot
p
erature o
t
ure will di
s
t
he image
.
gger agai
n
sciene t
e
m
al imag
e
n for > 2
e unit is
n
Auto Po
w
o
f time.
s
tatus ico
n
AC sourc
e
h
e unit).
h
arging R
e
p
ort. If the
R
p
and in u
s
here are
2 second
display. I
f
c
t of inter
to cold (li
g
f the spot
s
played o
n
.
Press”O
K
n
to discar
d
e
mperatur
e
e
r
seconds
t
ow ready
w
er OFF
n
is lo
c
e
or a co
m
e
d LED i
s
R
ed LED i
s
s
e while
c
the basic
s to pow
e
f
the batt
e
est and v
g
ht to dar
k
targeted
b
n
the scre
e
K
” to save
d
the imag
e
range,
P
t
o switch
to use; to
function
s
c
ated at th
m
puter US
B
s
ON wh
e
s
off, it ind
c
harging in
steps (co
v
e
r ON. Th
e
e
ry requir
e
iew the t
h
k
, respect
b
y the Cr
o
e
n.
image or
p
e.
P
ress “LO
ON the u
n
switch O
F
s
witches
t
e top left
o
B
port usin
g
e
n connec
t
icate the
b
which ca
s
HT6
4
v
ered in
m
e
logo sta
e
s recharg
h
ermal im
a
ively). Th
e
o
sshairs,at
p
ress “SH
A
CK” agai
n
n
it. A star
t
F
F, press
t
he unit
O
o
f the dis
p
g
the sup
p
t
ed to an
b
attery is f
u
s
e the bat
4
m
ore
rtup
ing,
a
ge.
e
IR
the
A
RE”
n
to
t
-up
and
O
FF
p
lay.
p
lied
AC
u
ll.
tery

2.3. The
(1).Curre
n
(2). Batte
r
(3). Hot t
e
(4). Cold
t
(5). Cent
r
(6). Cold
t
(7). Hotte
(8)Image
(9). Cent
r
(10). ”OK
”
(11).”LO
C
(12).Curr
e
(13).Sce
n
(14).Pale
t
(15).Sce
n
(16).Tim
e
2.4. Co
n
Bec
a
P
p
s
b
O
a
d
U
s
t
I
T
S
o
IR Therm
n
t Emiisivi
t
r
y indicato
e
mperatur
e
t
emperatu
r
r
e crosshai
t
emperatu
r
mperature
freezed ic
o
r
e tempera
”
button
C
K” button
e
nt tempe
r
n
e Low Te
m
t
te scale
n
e High Te
e
clock
n
trol Butt
o
a
me famill
i
P
OWER/
B
p
ower ON
s
cene te
m
b
utton wh
e
O
K/MEN
U
a
nd to sa
v
d
isplay ab
o
U
P and
D
s
elect a
m
t
he smart
I
mage Re
v
T
RIGGER
/
S
hort pre
s
o
pen the
L
al Imagin
g
t
y setting
r
e
point rea
r
e point re
a
r
r
e crossh
a
crosshai
r
o
n
ture point
r
ature unit
m
perature
mperature
o
ns and T
r
i
ar with th
e
B
ACK/LO
C
or OFF;
S
m
perature
r
e
n this opt
i
U
BUTTO
N
v
e an im
a
o
ve the b
u
D
OWN N
A
m
enu item
device.
P
v
iew mode
/
LED Fla
s
s
s again t
o
L
ED flashli
g
g
Display
ding
a
ding
a
i
r
reading
r
igger
e
operatio
n
C
K BUTT
O
S
hort pres
s
r
ange(a s
o
i
on is avail
N
Short pr
e
a
ge when
u
tton when
A
VIGATIO
N
setting.
W
P
ress and
.
s
hlightSh
o
o
discard i
m
g
ht,Long
p
n
of the co
n
O
N Press
s
to exit a
o
ft “ ” b
able).
e
ss to ac
c
prompted
this optio
n
N
ARRO
W
W
hen freez
e
hold the
D
o
rt press
w
m
age and
p
ress agai
n
n
trol butto
n
and hold
menu scr
e
utton will
c
ess the
S
(a soft “
S
n
is availa
b
W
BUTTO
N
e
aimage,
P
D
OWN ar
r
w
ill take
a
return to
n
will close
n
s and trig
> 2 seco
e
en. Also
appear o
n
S
ettings M
e
S
AVE” bu
t
b
le).
N
S Scroll
P
ress“UP”
r
ow for 4
a
snapsho
live imag
e
the LED
f
ger as de
s
nds to cy
used to lo
n
the disp
l
e
nu, to c
o
tton will
a
the Settin
will shar
e
seconds
t
t of the
c
e
mode. L
o
f
lashlight.
HT6
4
s
cribed be
l
cle the m
e
ck the cur
ay above
o
nfirm an
e
a
ppear on
gs Menu
e
the imag
e
t
o access
c
urrent im
a
o
ng press
4
l
ow:
e
ter
rent
the
e
dit,
the
and
e
to
the
a
ge.
will
EASTERN ENERGY CO.,LTD. (HEAD OFFICE)
40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170
Contact :
www.ete.co.th

2.5. Me
a
Po
Pu
share the
To
To
the store
d
Warning
:
3.0
Discr
2.6. Fro
n
1. T
F
2.
M
3. U
4. L
a
5. P
O
2.7. Bac
6.LED
7.I
R
8.
T
2.8. Top
9. Bat
t
10. U
S
a
sure,Sav
e
int the the
r
ll the trigg
e
image..
review an
delete im
a
d
images
a
:
All image
iptions
n
t descri
p
F
T Color
D
M
ENU-OK
b
P-Down a
r
a
nyard ac
c
O
WER-B
A
k descrip
t
Flash Lig
h
R
Imaging
T
rigge
r
descripti
o
t
ery Charg
S
B Battery
e
, Delete,
a
r
mal imag
e
e
r to captu
image, ei
t
a
ges form
a
s describ
e
s are dele
t
p
tions
D
isplay
b
utton
r
row butto
n
c
ess
A
CK butto
n
t
ions
h
t
len
o
ns
ing LED i
n
charging
i
a
nd Revi
e
er
toward
t
re the ima
t
her acces
s
the intern
a
e
d in Secti
o
t
ed when
t
n
s
n
n
dicato
r
i
nterface
e
w IR Ima
g
t
he object
o
ge.press“
S
s
the Setti
n
a
l memory
,
o
n 6 Setti
t
he interna
g
es
o
r area of
S
AVE” to
s
n
gs Menu
(
,
access t
h
ngs Men
u
l memory
interest.
s
ave imag
e
(
see Secti
h
e Setting
s
u
.
is erased.
e
. Press “
S
on 6).
s
Menu an
d
HT6
4
S
HARE” to
d
delete
4

2.9. Dis
p
p
lay Icon
a
:Battery
e
a
nd Indic
a
Temp
e
Max t
e
Minim
Freez
i
12 tim
IRON
e
mpty
a
tor Desc
r
e
rature un
e
mperatur
e
um tempe
r
i
ng image
e format
Color pal
e
: Bat
t
r
iption
its
e
readings
r
ature rea
d
icon
e
tte
t
ery Full
d
ings
: Battery
c
Cen
t
Hot
c
Cold
Unlo
c
Loc
k
Blue
t
c
harging
t
re crossh
a
c
rosshai
r
crosshai
r
ck icon
k
icon
t
ooth icon
HT6
4
a
i
r
4
EASTERN ENERGY CO.,LTD. (HEAD OFFICE)
40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170
Contact :
www.ete.co.th

3. Oper
t
3.1. Swi
t
Pre
s
charged,
t
image wil
l
show a r
e
does not
s
for inform
3.2. Loc
k
Th
e
pro
b
tha
n
tem
p
Pic 5-2 lo
c
1. P
o
2. S
the temp
e
3. S
h
t
ion
t
ch ON th
e
s
s and hol
d
t
he meter
w
l
show unt
e
al time IR
s
witch ON
ation rega
k
/Unlock
s
e
unit is r
e
b
lem,It ca
n
n
lock te
m
p
erature l
o
c
k mode
o
int the u
n
hort pres
s
e
rature re
a
h
ort press
e
thermal
d
for > 2 s
e
w
ill displa
y
il the shut
t
thermal i
m
, please r
e
rding batt
e
s
cene te
m
e
al 80x80
n
locks the
m
perature
o
wer than
t
n
it at an ob
j
s
the “
a
dings will
t
the “
imager
e
conds to
s
y
the start-
t
er resets
t
m
age alon
g
e
fer to Sec
e
ry chargi
n
Pic
m
perature
pixels the
current s
c
,the corr
e
t
he lock te
m
j
ect or an
a
” to lo
c
t
urn grey.
” button
s
witch the
up screen
t
he image.
g
with an I
R
tion 3.2P
o
n
g.
5-1 start l
level-spa
n
rmal imag
c
ene tem
p
e
sponding
m
perature
pic5-3 unl
o
a
rea of int
e
c
k the sce
n
again ,it
w
unit ON. I
f
as shown
After the
s
R
Temper
a
o
wering a
n
ogo
n
er, for bet
p
erature r
a
color is
range,the
o
ck mode
e
rest.
n
e tempe
r
w
ill unlock t
h
f
the unit i
s
below. T
h
s
tartup pe
r
a
ture readi
n
d chargin
g
ter get th
e
a
nge, if th
e
white;if
correspo
n
r
ature ran
g
h
e scene
t
s
sufficient
h
e initial di
s
r
iod, the u
n
ng. If the
m
g
thetherm
e
object te
e
temperat
the curr
e
n
ding colo
r
g
e; the ba
c
t
emperatu
r
HT6
4
ly
s
played
n
it will
m
eter
al image
r
,
mperatur
e
ure highe
r
e
nt scen
e
r
is black.
c
k color o
f
r
e range.
4
e
r
e
f

HT64
3.3. Screening mode for surface temperature measurement
The unit canwork in screening mode for surface temperature measurement.
1.Switch “Screening mode” option on in “Measure” menus(see § 6.4).
2.Set the Alarm temperature to appropriate value.
3.Set the Temperature compensation to appropriate value.
4.Switch “Center Spot” or “Temp. Max” on for surface temperature measurement.
5.If surface temperature is higher than the set alarm threshold it will be shown in red color
in the lower part of the display
3.4. Capture/Save Images using the Internal memory
The unit can store 20 images on internal memory. The saved images can be
transferred to iOS,android and PC device throughBlueTooth.
1. Point the unit at an object or an area of interest.
2. Short press the trigger to capture the image; the image will freeze.
3. If don’t want to save the current image, Short press the trigger again,the image
will unfreeze.
4. Press“SAVE” to save the image
5. If the image is stored successfully on the internal memory, the image will
unfreeze.
6. To erase/format internal memory please refer to Section 6 Settings Menu.
3.5. Share images using BlueTooth
3.5.1. Instant share
For quick analyse and report the thermal images,Theunit has Bluetooth
instant share function, corresponding there are threesoftwares for iOS,Android.
1. Enable the Bluetooth on the thermal imager
2. Run Apps on smart devices, connect unit with smart device or PC(Detailed
referece to Section 6.8 Settings Menu).
3.Point the unit at an object or an area of interest.
4. Short press the trigger to capture the image; the image will freeze. And the “hold”
icon will display.
5. If don’t want the current image, Short press the trigger again,the image will
unfreeze.

6.
P
7.
I
unfreeze.
8.
S
3.5.2. Tr
a
1.
E
2.
R
3.
T
review an
4.
P
5.
P
6.
S
3.6. Rev
Us
e
1.
T
2.
P
P
ress“SH
A
I
f the imag
S
ave,anal
y
a
nsfer the
E
nable th
e
R
un Apps
T
o access
d delete i
m
P
ress Trig
g
P
ress“SH
A
S
ave,anal
y
iew/Delet
e
e
the Revi
T
o access
P
ress the
b
A
RE” to tr
a
e is transf
e
y
se,share
o
Pic
5
saved i
m
e
Bluetoot
h
on smart
d
the Imag
e
m
ages.
g
er to sha
r
A
RE” to tr
a
y
se,share
o
e
Images
ew Mode
t
the Settin
g
b
ack butto
a
nsfe
r
the i
e
red succ
e
o
r report t
h
Pic5
_
5_
5Receiv
e
m
ages
h
on the u
n
d
evices, c
o
e
Review
m
r
e the curr
e
a
nsfe
r
the i
o
r report t
h
t
o view or
d
g
s Menu (
S
n to exit t
h
mage
e
ssfully to
h
e thermal
_
4Hold the
e
,analyse
a
n
it
o
nnectunit
m
ode, acc
e
e
nt pictur
e
mage
h
e thermal
d
elete sto
r
S
ection 6
-
h
e image r
e
t
he smart
d
images o
n
image
a
nd save
t
with sma
r
e
ss the Se
t
e
.
images o
n
r
ed image
s
-
10) to rev
e
view mo
d
d
evices, t
h
n
smart d
e
t
he image
r
t device o
t
tings Men
n
smart d
e
s
.
iew and d
e
d
e
h
e image
w
e
vices.
r PC.
u (Sectio
n
e
vices.
e
lete imag
e
HT6
4
w
ill
n
6-10) to
e
s.
4

3.
T
and refor
m
4.
C
or smart
d
3.7. Len
s
T
Fo
c
7.5
I
F
b
I
F
D
o
Exa
m
34u
m
3
D
D
D
t
e
T
t
e
t
h
T
o delete
a
m
at the S
D
C
onnect t
h
d
evices.
s
and Im
a
T
his table l
c
al Length
mm
F
O
V
(Inst
a
b
e detecte
d
F
OV = ( P
i
D
:S
theoretica
l
o
f the The
r
m
ple: If T
h
m
. Horizo
n
3
4um/7.5
m
D
:S
theoretica
l
D
:S
measure =
D
:S
measure
(
e
mperatu
r
T
ypically,
e
mperatu
r
h
at deter
m
a
ll images
,
D
card.
h
e DT-870
Y
a
ger Field
ists the h
o
Ho
r
21
°
a
ntaneous
d
or seen
a
i
xel Size )
/
l
( = 1/ IF
O
r
mal Imag
e
h
ermal Im
a
n
tal FOV i
s
m
m = 4.53
m
l
( = 1/ IF
O
D:S
theoreti
c
= 1/IFO
V
r
e measur
e
D:S
measure
r
e measur
e
m
ined by t
h
,
please a
c
Y
through
of View
o
rizontalF
O
r
izontal F
O
°
Field of
V
a
t a set di
s
/
( Lens f
o
O
V
theoretical
)
e
r detector
a
ger uses
s
17°, Ve
r
m
rad;
O
V
theoretical
)
c
al
/3 = 74:1
V
measure
) i
s
e
.
is 2 to 3
e
ment are
a
h
e calculat
e
c
cess the
S
Bluetooth,
O
V, vertica
l
O
V V
e
21
V
iew) is th
e
s
tance, th
e
o
cal lengt
h
)
is the cal
c
array and
9mm len
s
r
tical FOV
= 220:1
s
the spo
t
times sm
a
a
of the t
a
e
d theoreti
S
ettings M
e
and trans
f
l
FOV and
e
rtical FO
V
°
e
smallest
e
unit is ra
d
h
);
c
ulated sp
lens focal
s
, becaus
e
is 17°, th
t
size ne
e
a
ller than
a
rget need
cal D:S.
e
nu as de
s
f
er the sav
e
IFOV for l
V
IF
O
4.
5
detail wit
h
d
. The for
m
ot size ba
s
length.
e
the Pixe
e IFOV is
e
ded to
p
D:S
theoreti
c
to be 2 t
o
s
cribed in
S
e
d image
t
ens.
O
V
5
3mrad
h
in the FO
V
m
ula is this
s
ed on th
e
e
l Size of
d
p
rovide a
n
c
al
, which
m
o
3 times l
a
HT6
4
S
ection 6
t
o the PC
V
that ca
n
:
e
pixel siz
e
d
etector i
s
n
accurat
e
m
eans th
e
a
rger tha
n
4
n
e
s
e
e
n

HT64
4. SettingsMenus
4.1. Using Settings Menus
Press OK button to open the Settings Menus,as show below.
Press UP / DOWN button to select menu item or change the value of current
focus item.
Press OK button to enter the submenu or set focus on the current
sellecteditem.PressESC button to return to the previous menu.
If want to exit settings menus, can press HOLD button or press ESC button
in root menu.
4.2. Settings details
4.2.1. Palette mode
Thermal imager has five kinds of palette,such as: .\
Press OK button to select on of display color palettes.
4.3. Temp Unit
Press OK button to set focus on this option and the color of option value will change
to blcak .Infocus state, use the RIGHT / MENU button to toggle℃,℉ and K, use
ESC / OK button to exit focus state and the color of option value will change to blcak
.
4.4. Measure
Press OK button to enter measure menu.Two selections are available: Temp.Max
and Temp.Min.Press OK button to set cur select item on or off.
Screening mode:This option enables thermal imager measure surface
temperature.
Alarm temperature:In screening mode, if surface temperature is higher than
alarm temperature, then buzzer alarm will be triggered.

T
w
C
c
T
h
T
l
4.5. Emi
s
Pre
s
incr
e
avai
4.6. Lan
g
Pre
s
Chi
n
and
T
emperat
u
w
ill be co
m
C
enter S
p
c
enter sp
o
T
emp.Ma
x
h
ighest t
e
T
emp.Mi
n
l
owest te
s
sivity
s
s OK butt
e
ase or d
e
lable rang
e
g
uage
s
s OK bu
t
n
ese, Trad
use OK b
u
u
re com
p
m
pensat
e
p
ot:This o
o
t.
x
:This op
e
mperatur
n
:This op
t
mperatur
e
on to set
f
e
crease e
m
e
is 0.01 t
o
t
ton toto
e
itional Chi
u
tton to se
t
p
ensation
:
e
d.
ption ena
tion ena
b
e point.
t
ion ena
b
e
point.
f
ocus on t
h
m
issivity's
o
0.99 in 0
e
nter lang
u
nese and
t
selected
:
In scree
n
bles ther
m
b
les ther
m
b
les ther
m
h
is option.
value,use
E
.01 steps.
u
age men
u
English.U
s
language
t
n
ing mod
e
m
al imag
e
m
al imag
e
m
al imag
e
In focus s
t
E
SC / OK
u
.Threeop
t
s
e UP /D
O
t
o be valid
e
, ther s
u
e
r detect
t
e
r autom
e
r autom
a
t
ate, use
U
button to
t
ions are
O
WN butto
.
u
rface te
m
t
hertemp
e
atically
d
a
tically
d
U
P /DOW
N
exit focus
available:
n to selec
t
HT6
4
m
peratur
e
e
rature o
f
d
etect th
e
d
etect th
e
N
button t
o
state.Th
e
Simplifie
d
t
languag
e
4
e
f
e
e
o
e
d
e

4.7. Set
u
Pre
s
Brig
h
B
B
U
f
A
/
s
4.8. Blu
e
1)
T
u
p
s
s OK b
u
h
tness an
d
B
luetoot
h
B
rightne
s
U
P /DOW
N
f
ocus sta
t
A
uto Off:
P
/
DOWN b
u
s
leep mo
d
e
tooth Co
T
urn on th
u
tton to
e
d
Auto Off.
h
:UseOK
b
s
s:PressO
N
button
t
t
e.The av
a
P
ressOK
b
u
tton to
c
d
e.
nnect
e Bluetoot
e
nter set
u
b
utton to
s
K button
t
o chang
e
a
ilable bri
g
b
utton to
c
hoose th
e
h function
u
pmenu.T
h
s
et blueto
o
to set fo
c
e
LCD's b
r
g
htness's
set focu
s
e
time p
e
on the ins
t
h
ree opti
o
o
th powe
r
c
us on th
i
r
ightness,
range is
1
s
on this
o
e
riod afte
r
t
rument.
o
ns are
a
r
on or of
f
i
s option.
use ESC
1
00% to 1
o
ption.In
f
r
which t
h
a
vailable:
f
.
In focus
s
/ OK but
t
0% in 10
%
f
ocus stat
e
h
e meter
e
HT6
4
Bluetooth,
s
tate, us
e
t
on to exi
t
%
steps.
e
, use U
P
e
nters th
e
4
e
t
P
e

HT64
2) Turn on the bluetooth of smartphone,press the icon “Thermoview+” and enter into the
home interface, Then press Connect Device icon on the Home interface,bluetooth
device name will appear.
3) Touch the device name listed in bluetoothsheet, it will be transmitted
to laser distance meter measuring interface after connection.
The detail information about Thermview+,please refer to MeterBox Pro APP help
file.
Thermview+ for Android :
Please search in Google Play with keyword”Thermview+”,download and run.
Thermview+ for iOS:
Please search in Apple store with keyword” Thermview+”,download and run.

4.9. Tim
e
Pre
s
time
4.10. Me
m
Pre
s
Del
e
P
s
D
b
o
e
/Date
s
s OK butt
o
formate
m
ory
s
s OK butt
o
e
te Photo.
P
hoto Re
v
s
ettings
m
D
elete Ph
b
elow.Wa
o
f the me
m
o
n to ente
r
can be s
o
n to ente
r
v
iew:Pre
s
m
enus im
m
oto:After
rnning:S
e
m
ory car
d
r
timemen
u
et.The ch
r
memory
m
s
sOK but
t
m
ediately
.
Press O
K
e
lect 'YE
S
d
.
u
.In this m
anges ta
k
m
enu.Tw
o
t
on to en
t
.
K
button,
S
', will del
e
enu, yeas
,
k
e effect
a
o
options a
r
t
er imag
e
dialog bo
e
te all th
e
,
month, d
a
a
fter exitti
r
e availabl
e
e
browser
x will be
e
photos
i
a
y, hour,
m
ng settin
g
e
: Photo
R
function
,
displaye
d
i
n 'RECO
R
HT6
4
m
inute an
d
g
s menus
.
R
eview an
d
,
and eix
t
d
as sho
w
R
D' folde
r
4
d
.
d
t
w
r

4.11. Info
Pre
s
vers
4.12. Fac
t
W
d
mation
s
s OK bu
t
ion, hard
w
t
ory Set
W
hen sel
e
d
isplayed
a
t
ton to en
w
are's vers
e
ct Factor
y
a
s show b
e
ter syste
m
ion and th
e
y
Set opt
i
e
low.Sele
c
m
infomati
o
e
rmal ima
g
i
on, after
c
t 'YES' b
u
o
nmenu.T
g
er's versi
o
press OK
u
tton, syst
e
his menu
o
n.
button, t
h
e
m param
e
contains
h
edialog b
e
ter will be
HT6
4
software'
s
ox will b
e
reset.
4
s
e

HT64
5. Image Browser
5.1. In Image Browser mode. User can browse the pictures in 'RECORD' folder of
the memory card.PressUP / DOWN button to select prev or next picture.Press
any other keys to exit Image Browser mode.
1. Current displayed picture's filename..
2. Current picture's.index and total number of pictures.
3. Temperature.of center point.
4. Picture display area.
5.2. How to capture screen
When in Thermal imaging mode, use HOLD button to enter hold mode, as show
below.Then press OK button to capture screen.After saving to memorycompletly,
screen will exit hold mode.

HT64
6. Technical specifications
6.1. Technical characteristics
Field of view (FOV) / Minimum
focus distance
21°x 21°/ 0.5m
Spatial resolution (IFOV) 4.53mrad
Thermal sensitivity/NETD < 0.1°C @ +30°C (+86°F) / 100 mK
Image frequency 50Hz
Focus mode Focus free
Focal length 7.5mm
Focal Plane Array (FPA) / Spectral
range
Uncooledmicrobolometer / 8–14 µm
Object temperature range –20°C to +380°C (–4°F to +716°F)
Accuracy in Normal mode ±2°C (±3.6°F) or ±2% of reading(Environment
temperature 10℃-35℃,object temperature >0℃.
)
Accuracy in Screening mode ±0.5°C (±0.9°F) of reading(The object
temperature is between 32°C and42℃. )
Display 2’color TFT LCD screen,
Display resolution 240x320 pixels resolution
Battery Rechargeable 3.7V (1300mA) lithium ion battery
(not user-serviceable)
Battery lift >6hours,typical
Battery Charger 5V 1A USB charger(not include)
Drop Proof Designed for up to 2 meters
Connect Bluetooth BLE4.0, thermal image transfer and
data logger.
Save image format Bitmap (.bmp) with 6400 points
temperatureanalyse and emissivity
Operating Temperature 14 to 113oF (-10 to 45oC)
Storage Temperature -22 to 131oF (-30 to 55oC)
Allowable relative humidity <80%HR
Storage temperature -20° ÷ 60°C (-4°F 140°F)
Storage humidity <80%HR
EASTERN ENERGY CO.,LTD. (HEAD OFFICE)
40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170
Contact :
www.ete.co.th
Table of contents
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies U1840A Medalist sj5000 Hardware manual

Agilent Technologies
Agilent Technologies CrossLab CS user manual

Esco Medical
Esco Medical MIRI TL Series user manual

Miltenyi Biotec
Miltenyi Biotec CliniMACS Prodigy user manual

lbx
lbx HDB120 Series user manual

Heidolph
Heidolph REAX 2 operating manual