EasyPro MWF36 User manual

1
MWF36
Instructions for Operation • Safety • Warranty
Thank you for purchasing the Starburst Mini Pond Fountain. This fountain is powered by
an asynchronous mag drive pump that is designed for continuous duty. Since the motor
is oil-free, it's safe for plants, sh and wildlife. The fountain oat contains six built-in
super bright LED lights that provide a brilliant night time display. To use this product
safely and to maximum benet, be sure to read and follow these instructions. Keep a
copy of the instructions for reference.
Box Contents
Safety & Electrical Connections
1. Always disconnect the electrical supply before handling, maintaining,
repairing or installing any pond equipment.
2. Keep out of the reach of children.
3.
Always make sure you know the correct amps and voltage required before installing.
4. Use dedicated power outlet only. Sharing the outlet with other equipment may
cause overheating and re.
1 Asynchronous
Mag Drive Pump
with 30' Cord
1 Fountain Float
with 6 Built-In
LED Lights and 30'
Cord
1 Transformer 3 Stainless
Thumb Bolts
2 Mooring/Anchor
Ropes
STARBURST
MINI POND FOUNTAIN

2
5. Always connect to a Ground Fault Circuit (GFCI) to prevent electrical shock. Never
submerge connecting power cable plug in water.
6. Never let the pump run without water as this will damage the impeller,
overheat and possibly burn out the pump. This pump must stay
submerged entirely when operating. Running pump low on water will
cause overheating, premature failure and will void warranty.
7.
Do not use this product in bathrooms or swimming pools. For use with fresh water only.
8. Do not use in water over 95° F (35°C).
9.
All electrical work must be performed by a qualied technician. Always follow the
National Electrical Code (NEC) or the Canadian Electrical Code as well as all local,
state and provincial codes. Code questions should be directed to your local electrical
inspector. Failure to follow electrical codes and OSHA safety standards may result
in personal injury or equipment damage. Failure to follow manufacturer’s installation
instructions may result in electrical shock, re hazard, personal injury or death, damaged
equipment, provide unsatisfactory performance and may void manufacturer’s warranty.
10. Do not carry or lift the pump by the power cord.
11. Never use an extension cord or tamper with power cord. Power cord should not
become bent, twisted, abraded or cut. A damaged cable may cause electric
leakage, shock or re. The power cord cannot be replaced, and unit should be
replaced if cord becomes damaged.
12. Do not remove the pump housing during
operation of the pump.
Assembly and General Installation
1. Slide the fountain oat down over the top of
the pump until it sits securely.
2. Secure the oat by inserting the three thumb
bolts into every other hole. Finger tighten the
bolts until the tops of the bolts are ush with
the inner rim of the oat. Do not overtighten.
3.
Connect the light's power cord to the
transformer.
4.
Connect the mooring/anchor ropes to the oat.
5. Place the fountain in your pond and secure
with the mooring/anchor rope.
6. Plug the pump and light cords into a
GFCI outlet. (See Safety and Electrical
Connections on page 1 for important
instructions about power connections.)
7. Set the timer for the lights if desired.
Thumb Bolts
Inner Rim
of Float Step 2
Step 3
Step 1

3
Operation
The Starburst Fountain has two operation modes to choose from, depending on your
preference:
Continuous Mode: displays a xed spray pattern
Gradient Mode: displays a disappearing and reappearing spray.
To change between the two modes, simply unplug the fountain and plug it back in. When
rst powered on, the fountain defaults to the Continuous Mode.
Service & Maintenance
Disconnect all power supplies before inspection or service to avoid possible
electrical shock.
1. Regularly inspect and clean the pump housing to ensure that it is clear of debris or
algae which can reduce the ow.
2. Be sure the pump housing is closed and properly latched to prevent debris from
entering the pump.
3. Check the water level daily to ensure the pump remains fully submerged.
4.
If the pump is left in water but not operating regularly, test run it at least once a week.
5. Once per season the unit should be cleaned of any
debris build-up or mineral deposits on the impeller
assembly and housing. Areas with hard water may
require more frequent cleaning. To access the impeller:
A. Remove the zip tie securing the bottom screen.
B. Gently twist the bottom screen from the pump.
C. Inspect the impeller and chamber.
D. Clean using water and a damp cloth or sponge.
A vinegar mixture may help remove hard deposits
6. If the impeller is damaged, replace with a new impeller.
7.
Be sure the pump housing is closed and properly latched
before returning to the pond. A zip tie is recommended to
secure the unit.
8. Winterization/Storage: When the pump is out of use for
extended time - wash and dry it then store indoors in a
non-freezing location. It is essential to prevent any risk
of the pump freezing.
Step 5B

EasyPro Pond Products Limited Warranty
EasyPro Pond Products (“EasyPro”) warrants to the purchaser that this product (“Product”) will be free from any
mechanical or material defects for a period of one year from the date of purchase. G
askets, impellers and bulbs are
considered wearable items and are not covered under this limited warranty
This warranty only covers properly installed and maintained Products sold by authorized EasyPro Sellers who are
subject to and follow EasyPro’s quality control standards. Please note that because EasyPro is unable to control the
quality of Products sold by unauthorized sellers, unless otherwise prohibited by law, this warranty does not cover
Products purchased from unauthorized sellers.
This warranty does not cover normal wear and tear, nor any deterioration suered through overloading, improper
use, negligence, improper installation, acts of God or accident. Similarly, any modication made by the purchaser to
the Product will cause the warranty to be null and void. This warranty does not cover any cost associated with the
installation or removal of the Product subject to a warranty claim.
All returned items will be inspected to determine cause of failure before a warranty claim is approved.
The exclusive remedies provided hereunder shall, upon EasyPro’s inspection and option, be either repair or
replacement of the Product or parts covered under this warranty.
Making a Claim:
A Return Authorization (“RA”) number must rst be obtained by calling EasyPro at 800-448-3873 or
via email at [email protected]. It is the purchaser’s responsibility to pay the return shipping charges. Be sure to
include the RA number, original receipt (in the form of an invoice or sales receipt), your name, your return address and
your phone number inside of the package. No warranty claims will be honored without the original receipt that shows that
your purchase was made from an Authorized EasyPro Seller. Ensure the product is properly packaged and insured for the
replacement value. Damage due to improper packaging is the responsibility of the sender.
ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OF FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY LIMITED IN DURATION TO THE DURATION OF THE WARRANTY AS DESCRIBED ABOVE.
Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to
you.
EasyPro shall not be held liable for any damages caused by defective components or materials of this Product; or for
loss incurred because of the interruption of service; or any consequential/incidental damages and expenses arising
from the production, sale, use or misuse of this Product. Some States do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
EasyPro shall not be held liable for any loss of sh, plants or any other livestock as a result of any failure or defect of
this Product. This warranty gives you specic legal rights, and you may also have other rights that vary from State to
State.
800-448-3873 • Grant, Michigan
www.easypro.com • [email protected]
9332 • 6/21
Troubleshooting
Before taking any troubleshooting action, disconnect pump from the power
supply.
Does not start
• Make sure power cord is plugged in
• Check outlet GFCI or house circuit breaker
• Improper power supply
Pump is running, no/low spray
• Check pump housing or piping for obstructions
• Check pump housing or impeller for clogs
• Check if impeller is broken or stuck
• Water level is too low with pump sucking air
GFCI breaker tripping
• Power cord may be damaged and getting wet. The cord is not replaceable, so a new unit
will be required.
• Nuisance trip due to improper grounding
• Overloaded circuit
Pump stops
• Ensure pump is clear of obstructions
• Check that the impeller is in good condition. Replace if needed.
• Check power supply
Table of contents
Other EasyPro Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Bernini
Bernini Fleur de Lis Decor Top instruction manual

Sunnydaze Decor
Sunnydaze Decor LZH-155 quick start guide

FOUNTAINS.COM
FOUNTAINS.COM FT-118 Assembly instructions

YARDART
YARDART Platia FT-34 quick start guide

CLIMAQUA
CLIMAQUA VIDA 11 Set instructions

Halsey Taylor
Halsey Taylor 4592 FTN owner's manual

Campania International
Campania International Pina Assembly instructions

Murdock
Murdock A172-UG-D1-BFS Series Installation & maintenance instructions

Teal
Teal Handeman Xtra Installation and operating instructions

Jeco
Jeco FCL061 quick start guide

Northcote Pottery
Northcote Pottery Water Magic 2810226 Assembly and care instructions

Halsey Taylor
Halsey Taylor 4591 owner's manual