Malfunction/Status Display
ERR-02 = Motor Hall Fault/Motor Short Circuit
ERR-03 = Controller Failure
ERR-04 = Turn ON Fault
EER-06 = No Motor Signal
ERR-08 = Low Battery Alarm
Access to advanced parameters settings:
Press į and POWER buttons simultaneously for 4
seconds to access advanced parameter settings.
You can change the values of the predefined
settings with the + and – buttons. You will need to
scroll through (ODO), (TRIP), (AVG),
(DISTANCE) and (TIME) before entering into the
advanced parameters.
Settings are shown below (press į button to toggle between the parameters)
d1 (Wheel Diameter) = 14” – 30” and 700
cc (Quantity of Magnets) = 1 – 12 (Default 1)
00.0 (Units of Measurement) = km/h or mile/h
06.0 km/h (Walk Mode) = ON or OFF
Sd (Speed Limit) = 15 – 45 (Note, maximum speed limit must be ON for this setting)
A (Power Ampere Adjustment) = 6 – 32 (Default 25)
ɾɿ (Mode - EUR or JAP) = EUR
25.0 km/h (Maximum Speed Limit) = ON or OFF
Short-press POWER button to save current
value.
To return to normal operating, wait for 4 seconds.