ELECTRICAL CONNECTION
Step 5 : Now we are ready to have the electrician wire the solvent recycler
for model SR30 connect to 220 volts / 1 phase power to the electrical
junction box 1 that is provided in the back of the unit. The 7.5 gallons
recycler requires 15 Amp service.
For model SR60 connect to 220 volts / 1 phase power to the electrical
junction box that is provided in the back of the unit. The 15 gallons
recycler requires 30 Amp service.
Then connect a ground wire 2to the back of the unit ans use the
ground wire with a clip to ground the 55 gallons drum.
For units that come with the optional used solvent ll pump you will
need to connect with an ½ air line to the pump and suggest to put a lter
regulator before the air inlet of the pump and then adjust the air pressure
on the regulator to 80 PSI.
VACUUM INSTALLATION
1. Install the ¼ push in fitting
2. Install the air regulator
3. Install the clear tube coming from the recycler.
4. Install the vacuum generator assembly on the
tank and then connect the cleat tube coming from
the bottom of the tank.
5. Install the blue tube on the 2 push in fittings.
Note : Please Review the “General Arrangement” Drawing
.
MAKE SURE ALL CODE REQUIREMENTS ARE FOLLOWED
.
You are now ready to follow the Start-up Process.