Wall PIR Sensor
ECO-13
Manual
Welcome to use ECO-13 infrared motion sensor!
The product adopts good sensitivity detector and integrated circuit. It gathers automatism,
convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from
human as control-signal source and it can start the load at once when one enters detection field. It
can identify day and night automatically. It is easy to install and used widely.
SPECIFICATION:
Power Source: 220-240V/AC Detection Range: 160°
Power Frequency: 50Hz Detection Distance: 9m max(<24℃)
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.7min±2min Power Consumption: approx 0.5W
Rated Load: Max.500W Installation Height: 1-1.8m
200W Detection Moving Speed: 0.6-1.5m/s
FUNCTIONS:
Can identify day and night: The consumer can adjust working state in different ambient light.
It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can
work in the ambient light less than 3LUX when it is adjusted on the “moon” position (min).
As for the adjustment pattern, please refer to the testing pattern.
Time-Delay is added continually: When it receives the second induction signals within the
first induction period, it will compute time oncemore on the basic of the first time-delay rest.
The switch: “ON”、“OFF”、“PIR”.
Good sensitivity Poor sensitivity
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Unload the faceplate of sensor and adjust the time and LUX knob.(refer to figure 1)
Loose the screws in the connection terminal, and then connect the power to connection
terminal of sensor according to connection-wire diagram.
If you want to install it in circular hole, put the sensor into the hole and tighten the splay bolt
on both sides (refer to figure 2). If you want to install in quadrate hole, put the sensor into
the hole, fix the screw through the mounting hole (refer to figure 3).
Install back the faceplate, switch on the power and then test it.
Figure1 Figure2 Figure3
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
Set the function switch to “ON”, set “TIME”
anti-clockwise to minimum, “LUX”clockwise to
maximum.
Switch on the power, the lamp should be on.
Set the function switch to “OFF”, the lamp should be off immediately.
Set the function switch to “PIR”, at first the load and the indicator lamp don’t work. After
Warm-up 30sec, the indicator lamp turns on .Under the condition of no sense signal, the
load should stop working within 10sec±3sec and the indicator lamp would turn off.
Set “LUX” anti-clockwise to minimum, if the ambient light is more than 3LUX, the inductor
load should not work after the load stop working. If you cover the detection window with
the opaque objects (towel etc), the load would work .Under no induction signal condition,
the load should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise
the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to affect to
receive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.

Other ecosens Accessories manuals

ecosens EL-M10 User manual

ecosens

ecosens EL-M10 User manual

ecosens EL-M08 User manual

ecosens

ecosens EL-M08 User manual

ecosens ECO-03 User manual

ecosens

ecosens ECO-03 User manual

ecosens EL-M0751 User manual

ecosens

ecosens EL-M0751 User manual

ecosens ECO-11 User manual

ecosens

ecosens ECO-11 User manual

ecosens ECO-14 User manual

ecosens

ecosens ECO-14 User manual

ecosens EL-M09 User manual

ecosens

ecosens EL-M09 User manual

ecosens ECO-015 User manual

ecosens

ecosens ECO-015 User manual

Popular Accessories manuals by other brands

CraftBilt Materials The Northlander installation guide

CraftBilt Materials

CraftBilt Materials The Northlander installation guide

IFM Efector 200 OG operating instructions

IFM

IFM Efector 200 OG operating instructions

Virone DB-1 manual

Virone

Virone DB-1 manual

B&G universal interface box manual

B&G

B&G universal interface box manual

Vega VEGAFLEX 65 operating instructions

Vega

Vega VEGAFLEX 65 operating instructions

IFM OG operating instructions

IFM

IFM OG operating instructions

Modine Manufacturing ECO CGL Technical manual

Modine Manufacturing

Modine Manufacturing ECO CGL Technical manual

AND AD-4430A instruction manual

AND

AND AD-4430A instruction manual

Jabra GN1000 datasheet

Jabra

Jabra GN1000 datasheet

Prentke Romich Company Optical Headpointer Mounting instructions

Prentke Romich Company

Prentke Romich Company Optical Headpointer Mounting instructions

Lippert Components Solera owner's manual

Lippert Components

Lippert Components Solera owner's manual

Lightolier LYTESPAN CONVENIENCE OUTLET Instructions for maintenance reference

Lightolier

Lightolier LYTESPAN CONVENIENCE OUTLET Instructions for maintenance reference

SICK UC30-2 Series operating instructions

SICK

SICK UC30-2 Series operating instructions

Laird AA-230 Series Specification and user manual

Laird

Laird AA-230 Series Specification and user manual

Biral RWS Series quick start guide

Biral

Biral RWS Series quick start guide

Titan TP270B user manual

Titan

Titan TP270B user manual

MTS Systems Temposonics III Programming guide

MTS Systems

MTS Systems Temposonics III Programming guide

Tork WOS-M installation instructions

Tork

Tork WOS-M installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.