Welcome to use EL-M10 Microwave Sensor!
The product is a new saving-energy switch; it adopts microwave sensor mould with high-
frequency electro-magnetic wave (5.8GHz), integrated circuit. It gathers automatism,
convenience, safety, saving-energy and practicality functions. The wide detection field is
consisting of detectors. It works by receiving humanmotion. When one enters the detection field,
it can start the load at once and identify automatically day and night. Its installation is very
convenient and its using is very wide. Detection is possible through doors, panes of glass or thin
walls.
SPECIFICATION:
Power Sourcing: 220-240V/AC Power Frequency: 50/60Hz
HF System: 5.8GHz CW radar, ISM band Detection Range: 360°
Ambient Light: <3-2000LUX (adjustable) Installing Height: 1.5~3.5m
Rated Load: 2000W (incandescent lamp) Transmission Power: <10mW
100W (energy-saving lamp) Time-Delay: min.:10sec±3sec
Power Consumption: approx 0.9W Max.: 15min±3min
Detection Distance: 1-8m (radius) (<24℃) adjustable Detection Motion Speed:0.6~1.5m/s
FUNCTION:
Can identify day and night: It can work in the daytime and at night when it is adjusted to the
“sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on
the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
SENS adjustable: It can be adjusted according to using location; low sensitivity with 2m for
detection distance; High sensitivity with 16m, it fits for largeroom.
Time-Delay is added continually: When it receives the second induction signals after the
first induction, it will compute time once more on the basic of the first time-delay rest.
Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum
time is 10sec±3sec. The maximum is 12min±1min.
NOTE: the high-frequency output of this sensor is
<10Mw- that is just one 100th of the transmission
power of a mobile phone or the output of a microwave
oven.
INSTALLATIION: (see the diagram)
Switch off the power.
Fix the bottom on the selected position with the inflated screw through the screw holes at
the side of the sensor.
Connecting the power and the load to sensor as per the connection-wire sketch diagram.
Switch on the power and testit.
Connection illumination
Connect L, N with power;
Connect N, A with load.
TEST:
Turn the LUX knob clockwise on the
maximum. Turn the TIME knob anti-
clockwise on the minimum, Turn the
SENS knob clockwise on themaximum.
When you switch on the power, the light
will be on at once, and 5-30 seconds
later will be off automatically. Then if the light receives induction signal, it can work
normally.
After 5-10sec of the first detection, the light could work again. If there is no induction signal,
the load should be stopped working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTES
:
Electrician or experienced human can install it.
The unrest objects can’t be regarded as the installation basis-face.
In front of the detection window there shouldn’t be hinder or unrest objects affecting
detection.
Avoid installing it near air temperature alteration zones for example: air condition, central
heating, etc.
For your safety.Please don’t open the case if you find hitch afterinstallation.
In order to avoid the unexpected damage of product, please add a safe device of 6A when
installing Microwave sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don’t work:
a. Check the power and theload.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on aftersensing, please check if the working light
corresponds to the ambientlight.
d. Please check if the working voltage corresponds to the powersource.
The sensitivity is poor:
a. Please check if in front of the detection window there is hinder that has effect on
receiving the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detectionfields.
d. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detectionfields.
b. If the time delay is set to thelongest.
c. If the power corresponds to theinstruction.
d. If the air temperature changes near the sensor, air condition or central heating etc.

Other ecosens Accessories manuals

ecosens ECO-13 User manual

ecosens

ecosens ECO-13 User manual

ecosens EL-M09 User manual

ecosens

ecosens EL-M09 User manual

ecosens ECO-11 User manual

ecosens

ecosens ECO-11 User manual

ecosens ECO-015 User manual

ecosens

ecosens ECO-015 User manual

ecosens ECO-03 User manual

ecosens

ecosens ECO-03 User manual

ecosens EL-M0751 User manual

ecosens

ecosens EL-M0751 User manual

ecosens EL-M08 User manual

ecosens

ecosens EL-M08 User manual

ecosens ECO-14 User manual

ecosens

ecosens ECO-14 User manual

Popular Accessories manuals by other brands

PASCO PS-3220 reference guide

PASCO

PASCO PS-3220 reference guide

PCB Piezotronics 137B29B manual

PCB Piezotronics

PCB Piezotronics 137B29B manual

NEOS Smart Leak Sensor Kit quick start

NEOS

NEOS Smart Leak Sensor Kit quick start

Syrinix PIPEMINDER S product manual

Syrinix

Syrinix PIPEMINDER S product manual

Shure N78s user manual

Shure

Shure N78s user manual

Manitowoc K00384 installation instructions

Manitowoc

Manitowoc K00384 installation instructions

Steren TIM-255 instruction manual

Steren

Steren TIM-255 instruction manual

TSI Instruments 8691-2 installation instructions

TSI Instruments

TSI Instruments 8691-2 installation instructions

Royal Catering RCGK-208C user manual

Royal Catering

Royal Catering RCGK-208C user manual

Meari Bell 15S quick guide

Meari

Meari Bell 15S quick guide

Häfele 568.26.340 manual

Häfele

Häfele 568.26.340 manual

Focusrite Scarlett 6i6 user guide

Focusrite

Focusrite Scarlett 6i6 user guide

Campbell CS506 instruction manual

Campbell

Campbell CS506 instruction manual

Silver Cross Linear Chassis manual

Silver Cross

Silver Cross Linear Chassis manual

NUVE EN 032 user manual

NUVE

NUVE EN 032 user manual

Hytronik HC005S/BT Installation and instruction manual

Hytronik

Hytronik HC005S/BT Installation and instruction manual

EdgeStar CBR1502SG owner's manual

EdgeStar

EdgeStar CBR1502SG owner's manual

Waterpik Ultra Dental Water Jet manual

Waterpik

Waterpik Ultra Dental Water Jet manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.