Edimax SB-1002W User manual

SB-1002W
Quick Installation Guide
12-2019 / v2.0

2
Contents
I. Safety Information & Reminder...........................3
II. Product Information.............................................4
II-1. Package Content..............................................................................4
II-2. System Requirement .......................................................................4
II-3. LED Indicator ...................................................................................5
II-4. Hardware Interface .........................................................................7
III. Hardware Installation ............................................8
III-1. RS485 Terminal Wire Connection...............................................10
IV. Wi-Fi Connection ................................................12
IV-1. Connect Signal Board to the Airbox (Wi-Fi Setup)......................13
V. RS485 Connection.............................................18
V-1. Connect Signal Board to the Airbox (RS485) .............................19
VI. WI-FI AP Display Mode ...................................20
VII. Firmware Upgrade .........................................21
VIII. Factory Default..............................................23
IX. Reboot The Device...........................................25

3
I. Safety Information & Reminder
For effective sensing and retrieval of environmental data, please install the
unit with the safety restrictions stated below:
-Move the Signal Board in a gental manner, no collision and strike.
-Please do not perform installation in harsh weather (such as strong winds).
-Keep away from items that will cause damages to the Signal Board (e.g.
sharp objects).
-Must be in locations close to a power supply and has good Wi-Fi internet
signal capable of connecting to the Internet 24 hours a day, 7 days a week.
-Do not let the conductive metal such as water and iron powder go into the
LED display cabinet.
-Wipe the LED screen gently with a soft cloth.
Unable to follow the above-mentioned guideline may reduce machine
lifetime.
You can find all supporting documents from the link below or via QR Code:
https://www.edimax.com/download
(Once you’ve visited the Edimax official website, please enter model no.
“SB-1002W”into the search box to search for your product.)

4
II. Product Information
II-1. Package Content
Signal Board
Quick Installation
Guide
Power Adapter
II-2. System Requirement
-Edimax AirBox air quality detector installed.
-Internet with Wi-Fi connection (802.11n).
-Computer or mobile device with web browser.

5
II-3. LED Indicator
II-4. LED Status
NOTE: All LEDs blinking when the device is on.
II-5. Color and Status
Color
PM2.5 Range
Recommend Action
Green
0 ~ 15
N/A
Yellow
16 ~ 35
N/A
Orange
36 ~ 54
Wearing a facemask to lessen
air-pollution exposure.
Red
55 ~ 150
Everyone should limit outdoor exertion.
Purple
151 ~ 250
Everyone should avoid prolonged
strenuous exercise.
Reddish
>250
Everyone should avoid all outdoor
exertion and stay inside.
Color
Status
Description
White
Flash
Resetting to factory default.
Red
Flash
Wi-Fi is not connected.
Blue
Flash
Signal board is not connected to the airbox.
Color LED Indicator (PM2.5)
Air Quality Level Color
Indicator (PM2.5)
Current PM2.5
Current Temperature
Current Humidity
Recommend Action

6
NOTE: PM2.5 range and recommend action are subject to the local air
quality regulations.

7
II-4. Hardware Interface
No.
Description
1
Default Button
2
Reboot Button
3
Power Jack
4
RS485 Terminals
5
Wall-Mount/ Hanging Hole
1
2
3
4
5

8
III.Hardware Installation
Make sure your AirBox air quality detector is installed before setting up.
Connect the power jack:
1. Unscrew the back cover screw and connect the power supply.
2. Make sure the warning rubber is pulled in the signal board.

9
3. Screw the back cover, power on signal board and check the screen for any
abnormality.
Note: Make sure the power supply is pulled underneath the RS485 and
make sure both are connected properly.

10
III-1. RS485 Terminal Wire Connection
If you would like to connect the signal board to the AirBox air quality detector
through the RS485 terminal instead of Wi-Fi, please go through the following
steps before screwing the back cover.
1. Connect the connection wires to signal board’s RS485 terminal and
screw the wires tightly.
2. Connect the other end of the wires to AirBox air quality detector’s
RS485 terminal and screw the wires tightly.
Note: The connection wires are excluded from the package.

11
Wall-mount or hang your signal board on the wall and power on the signal
board.
1. The back Screw the wall-mount screws on the wall and hang the
signal board.
2. Power on the signal board and check the screen for any abnormality.
Note:
˙Place your signal board within a good Wi-Fi signal range if you are
connecting the air quality detector through Wi-Fi.
˙Mounting screws are excluded from the package.

12
IV. Wi-Fi Connection
Supported AirBox:
-AI-1001W V2 - AI-2002W
-AI-1001W V3 - AI-2003W
-AI-1001W V4 - AI-2004W
Network Diagram:

13
IV-1. Connect Signal Board to the Airbox (Wi-Fi Setup)
Please follow the steps below to connect the signal board to the airbox via
Wi-Fi:
1. Connect the device either through the mobile phone or computer to the
Wi-Fi SSID of your signal board (EdimaxSB.Setup_XX).
Please find the unique SSID of your signal board on the product label.
The last 2 digits ** of the SSID “EdimaxSB.Setup_XX”is the last two
digits of the signal board's label.
2. Open a browser, login default IP address “192.168.4.1”and follow the
steps on the next page to set up the signal board through the web page
interface.
3. Tap on “Wi-Fi Settings”. And enter a valid “Wi-Fi SSID”and “password”.
NOTE: You can either choose “Dynamic IP (DHCP)”or “Static IP”.

14
4. Click the “OK”button.
NOTE: Signal board will disconnect and restart after clicking the “OK”button.
Please refresh the page after the device reboot.
NOTE: Connection status shows connected if the device is successfully
connected.
5. Go to the “DATA SOURCE”page.

15
6. Open the drop down menu labelled “Data Source ” and select “Wi-Fi”. Click
the “OK”button.
NOTE: Signal board will be disconnected and restarted after clicking the “OK”
button. Please refresh the page after device reboot.
Please follow the steps and instructions below to connect your signal board to
the airbox.
7. Connect the airbox to the EdiGreen or EdiGreen Plus, and make sure that
the airbox Wi-Fi SSID must be the same as the signal board Wi-Fi SSID.
NOTE: You may follow the instructions given in Airbox QIG or manual to
install the airbox. Please visit our website
https://www.edimax.com/edimax/global/ to download the latest version
Airbox QIG.

16
8. Go to “DATA SOURCE”.
9. Click the “REFRESH AIRBOX LIST”button.

17
4. Select the airbox by using the dropdown menu. And enter the airbox
password.
3. Click the “OK”button.
NOTE: Please refresh the page after clicking the “OK” button. And wait
about 27~35 seconds for the setup to complete.

18
V. RS485 Connection
Supported AirBox:
-AI-2003W
-AI-2004W
Network Diagram:
NOTE: Before setting up, please check if the signal board is connected to the
airbox through RS485. You may refer to Pg. 10 for more details.

19
V-1. Connect Signal Board to the Airbox (RS485)
Please follow the steps below to connect the signal board to the airbox via
RS485,
1. Open a browser and login the default IP address “192.168.4.1”of the signal
board.
2. Go to the “DATA SOURCE”page.
3. Open the drop down menu labelled “Data Source ” and select “RS485”. And
click the “OK”button.

20
VI. WI-FI AP Display Mode
In Wi-Fi AP display mode section you can decide to show, close or close the
Wi-Fi SSID.
-Show: You can configure your signal board to show the SSID.
-Hide: You can configure your signal board to hide the SSID.
-Close: Disable Wi-Fi SSID.
NOTE: If you select “Close”in Wi-Fi AP display mode, please make sure to
remember the IP address of your signal board.
Table of contents
Popular Control Panel manuals by other brands

Bender
Bender COMTRAXX CP9 Series quick start guide

ETC
ETC Echo Control Series installation guide

Control Equipment
Control Equipment Discovery Application guide

Ness
Ness D16x C-Bus Enabled Installation & programming manual

Menvier Security
Menvier Security TS400 Installation & programming instructions

Beijer Electronics
Beijer Electronics iX Panel T60 Service maintenance manual